Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Optimizing detector geometry for trace element mapping by X-ray fluorescence

Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal application of Morrison's iterative noise removal for deconvolution. Appendices

Morrison's iterative method of noise removal, or Morrison's smoothing, is applied in a simulation to noise-added data sets of various noise levels to determine its optimum use. Morrison's smoothing is applied for noise removal alone, and for noise removal prior to deconvolution. For the latter, an accurate method is analyzed to provide confidence in the optimization. The method consists of convolving the data with an inverse filter calculated by taking the inverse discrete Fourier transform of the reciprocal of the transform of the response of the system. Various length filters are calculated for the narrow and wide Gaussian response functions used. Deconvolution of non-noisy data is performed, and the error in each deconvolution calculated. Plots are produced of error versus filter length; and from these plots the most accurate length filters determined. The statistical methodologies employed in the optimizations of Morrison's method are similar. A typical peak-type input is selected and convolved with the two response functions to produce the data sets to be analyzed. Both constant and ordinate-dependent Gaussian distributed noise is added to the data, where the noise levels of the data are characterized by their signal-to-noise ratios. The error measures employed in the optimizations are the L1 and L2 norms. Results of the optimizations for both Gaussians, both noise types, and both norms include figures of optimum iteration number and error improvement versus signal-to-noise ratio, and tables of results. The statistical variation of all quantities considered is also given.

Ioup, George E.↗

Comparison of a transmission grating spectrometer to a reflective grating spectrometer for standoff laser-induced breakdown spectroscopy measurements

We evaluate a new transmission grating spectrometer for standoff laser-induced breakdown spectroscopy (LIBS) measurements. LIBS spectra collected from standoff distances are often weak, with smaller peaks blending into the background and noise. Scattered light inside the spectrometer can also contribute to poor signal-to-background and signal-to-noise ratios for smaller emission peaks. Further, collecting standoff spectra can be difficult because most spectrometers are designed for laboratory environments and not for measurements in the field. To address these issues, a custom-designed small, lightweight transmission grating spectrometer with no moving parts was built that is well suited for standoff LIBS field measurements. The performance of the spectrometer was quantified through 10 m standoff LIBS measurements collected from aluminum alloy samples and measurements from spectra of a Hg-Ar lamp. The measurements were compared to those collected using a Czerny-Turner reflective grating spectrometer that covered a similar spectral range and used the same ICCD camera. Measurements using the transmission grating spectrometer had a 363% improved signal-to-noise ratio when measured using the 669 nm aluminum emission peak.

74 ATOMIC AND MOLECULAR PHYSICS↗

Punctured Parallel and Serial Concatenated Convolutional Codes for BPSK/QPSK Channels

As available bandwidth for communication applications becomes scarce, bandwidth-efficient modulation and coding schemes become ever important. Since their discovery in 1993, turbo codes (parallel concatenated convolutional codes) have been the center of the attention in the coding community because of their bit error rate performance near the Shannon limit. Serial concatenated convolutional codes have also been shown to be as powerful as turbo codes. In this dissertation, we introduce algorithms for designing bandwidth-efficient rate r = k/(k + 1),k = 2, 3,..., 16, parallel and rate 3/4, 7/8, and 15/16 serial concatenated convolutional codes via puncturing for BPSK/QPSK (Binary Phase Shift Keying/Quadrature Phase Shift Keying) channels. Both parallel and serial concatenated convolutional codes have initially, steep bit error rate versus signal-to-noise ratio slope (called the -"cliff region"). However, this steep slope changes to a moderate slope with increasing signal-to-noise ratio, where the slope is characterized by the weight spectrum of the code. The region after the cliff region is called the "error rate floor" which dominates the behavior of these codes in moderate to high signal-to-noise ratios. Our goal is to design high rate parallel and serial concatenated convolutional codes while minimizing the error rate floor effect. The design algorithm includes an interleaver enhancement procedure and finds the polynomial sets (only for parallel concatenated convolutional codes) and the puncturing schemes that achieve the lowest bit error rate performance around the floor for the code rates of interest.

Acikel, Omer Fatih↗

Improving topological cluster reconstruction using calorimeter cell timing in ATLAS

Clusters of topologically connected calorimeter cells around cells with large absolute signal-to-noise ratio (topo-clusters) are the basis for calorimeter signal recon struction in the ATLAS experiment. Topological cell clus tering has proven performant in LHC Runs 1 and 2. It is, however, susceptible to out-of-time pile-up of signals from soft collisions outside the 25 ns proton-bunch-crossing window associated with the event’s hard collision. To reduce this effect, a calorimeter-cell timing criterion was added to the signal-to-noise ratio requirement in the clustering algorithm. Multiple versions of this criterion were tested by reconstructing hadronic signals in simulated events and Run 2 ATLAS data. The preferred version is found to reduce the out-of-time pile-up jet multiplicity by ~50% for jet p T ~ 20 GeV and by ~80% for jet p T ≳ 50 GeV, while not disrupting the reconstruction of hadronic signals of interest, and improving the jet energy resolution by up to 5% for 20 < p T < 30 GeV. Pile-up is also suppressed for other physics objects based on topo-clusters (electrons, photons, τ-leptons), reducing the overall event size on disk by about 6% in early Run 3 pile up conditions. Offline reconstruction for Run 3 includes the timing requirement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Channel assignments and array gain bounds for the Ka-band array feed compensation system

The performance of a real-time digital combining system for use with array feeds was considered previously. The purpose of the combining operation is to recover signal to noise ratio (SNR) losses due to antenna deformations and atmospheric effects. Previously, arbitrary signal powers and noise variances were assumed, but no attempt was made to match the receiver channels to the available signal powers. It is shown that for any signal power and noise variance distribution, a best channel assignment exists that maximizes the combined SNR in the limit of vanishingly small combining losses. This limit can be approached in practice by observing sufficiently many samples. Specific signal power and noise variance distributions are considered, and it is shown that even relatively noisy channels can be used effectively to recover SNR losses resulting from signals diverted out of a high-quality channel by antenna deformations.

Vilnrotter, V. A.↗

BIAS-FREE SHEAR ESTIMATION USING ARTIFICIAL NEURAL NETWORKS

Bias due to imperfect shear calibration is the biggest obstacle when constraints on cosmological parameters are to be extracted from large area weak lensing surveys such as Pan-STARRS-3{pi}, DES, or future satellite missions like EUCLID. We demonstrate that bias present in existing shear measurement pipelines (e.g., KSB) can be almost entirely removed by means of neural networks. In this way, bias correction can depend on the properties of the individual galaxy instead of being a single global value. We present a procedure to train neural networks for shear estimation and apply this to subsets of simulated GREAT08 RealNoise data. We also show that circularization of the point-spread function (PSF) before measuring the shear reduces the scatter related to the PSF anisotropy correction and thus leads to improved measurements, particularly on low and medium signal-to-noise data. Our results are competitive with the best performers in the GREAT08 competition, especially for the medium and higher signal-to-noise sets. Expressed in terms of the quality parameter defined by GREAT08, we achieve a Q{approx} 40, 140, and 1300 without and 50, 200, and 1300 with circularization for low, medium, and high signal-to-noise data sets, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

CODING METHODS FOR USE WITH LOW POWER LASER GENERATED ULTRASOUND

We describe how the application of maximum-length sequence (m-sequence) coding can be used to improve the measured signal-to-noise ratio of ultrasonic waves generated by a low power laser diode. Lamb waves were generated in thin metallic plates using a pulsed excitation. To improve the signal-to-noise ratio of the detected signal, various signal processing methods have been evaluated, with m-sequences described here. We also show how the spectral content of the ultrasonic wave can be controlled by using a modified m-sequence approach.

36 MATERIALS SCIENCE↗

Search for gamma-ray events in the BATSE data base

We find large location errors and error radii in the locations of channel 1 Cygnus X-1 events. These errors and their associated uncertainties are a result of low signal-to-noise ratios (a few sigma) in the two brightest detectors for each event. The untriggered events suffer from similarly low signal-to-noise ratios, and their location errors are expected to be at least as large as those found for Cygnus X-1 with a given signal-to-noise ratio. The statistical error radii are consistent with those found for Cygnus X-1 and with the published estimates. We therefore expect approximately 20 - 30 deg location errors for the untriggered events. Hence, many of the untriggered events occurring within a few months of the triggered activity from SGR 1900 plus 14 are indeed consistent with the SGR source location, although Cygnus X-1 is also a good candidate.

Lewin, Walter↗

Analyzing the cosmic variance limit of remote dipole measurements of the cosmic microwave background using the large-scale kinetic Sunyaev Zel'dovich effect

Due to cosmic variance we cannot learn any more about large-scale inhomogeneities from the primary cosmic microwave background (CMB) alone. More information on large scales is essential for resolving large angular scale anomalies in the CMB. Here we consider cross correlating the large-scale kinetic Sunyaev Zel'dovich (kSZ) effect and probes of large-scale structure, a technique known as kSZ tomography. The statistically anisotropic component of the cross correlation encodes the CMB dipole as seen by free electrons throughout the observable Universe, providing information about long wavelength inhomogeneities. We compute the large angular scale power asymmetry, constructing the appropriate transfer functions, and estimate the cosmic variance limited signal to noise for a variety of redshift bin configurations. The signal to noise is significant over a large range of power multipoles and numbers of bins. We present a simple mode counting argument indicating that kSZ tomography can be used to estimate more modes than the primary CMB on comparable scales. A basic forecast indicates that a first detection could be made with next-generation CMB experiments and galaxy surveys. This paper motivates a more systematic investigation of how close to the cosmic variance limit it will be possible to get with future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing of Performance of Optical Fibers Under Irradiation in Intense Radiation Fields, When Subjected to Very High Temperatures

The primary objective of this project is to measure and model the performance of optical fibers in intense radiation fields when subjected to very high temperatures. This research will pave the way for fiber optic and optically based sensors under conditions expected in future high-temperature gas-cooled reactors. Sensor life and signal-to-noise ratios are susceptible to attenuation of the light signal due to scattering and absorbance in the fibers. This project will provide an experimental and theoretical study of the darkening of optical fibers in high-radiation and high-temperature environments. Although optical fibers have been studied for moderate radiation fluence and flux levels, the results of irradiation at very high temperatures have not been published for extended in-core exposures. Several previous multi-scale modeling efforts have studied irradiation effects on the mechanical properties of materials. However, model-based prediction of irradiation-induced changes in silica's optical transport properties has only recently started to receive attention due to possible applications as optical transmission components in fusion reactors. Nearly all damage-modeling studies have been performed in the molecular-dynamics domain, limited to very short times and small systems. Extended-time modeling, however, is crucial to predicting the long-term effects of irradiation at high temperatures, since the experimental testing may not encompass the displacement rate that the fibers will encounter if they are deployed in the VHTR. The project team will pursue such extended-time modeling, including the effects of the ambient and recrystallization. The process will be based on kinetic MC modeling using the concept of amorphous material consisting of building blocks of defect-pairs or clusters, which has been successfully applied to kinetic modeling in amorphized and recrystallized silicon. Using this procedure, the team will model compensation for rate effects, and the interplay of rate effects with the effects of annealing, to accurately predict the fibers' reliability and expected lifetime

36 MATERIALS SCIENCE↗

Data Transmission Signal Design and Analysis

The error performances of several digital signaling methods are determined as a function of a specified signal-to-noise ratio. Results are obtained for Gaussian noise and impulse noise. Performance of a receiver for differentially encoded biphase signaling is obtained by extending the results of differential phase shift keying. The analysis presented obtains a closed-form answer through the use of some simplifying assumptions. The results give an insight into the analysis problem, however, the actual error performance may show a degradation because of the assumptions made in the analysis. Bipolar signaling decision-threshold selection is investigated. The optimum threshold depends on the signal-to-noise ratio and requires the use of an adaptive receiver.

Moore, J. D.↗

New Method for Calibration for Hyperspectral Pushbroom Imaging Systems

A new, easy-to-implement approach for achieving highly accurate spectral and radiometric calibration of array-based, hyperspectral pushbroom imagers is presented in this paper. The equivalence of the plane of the exit port of an integrating sphere to a Lambertian surface is utilized to provide a field-filling radiance source for the imager. Several different continuous wave lasers of various wavelengths and a quartz-tungsten-halogen lamp internally illuminate the sphere. The imager is positioned to "stare" into the port, and the resultant data cube is analyzed to determine wavelength calibrations, spectral widths of channels, radiometric characteristics, and signal-to-noise ratio, as well as an estimate of signal-to-noise performance in the field. The "smile" (geometric distortion of spectra) of the system can be quickly ascertained using this method. As the price and availability of solid state laser sources improve, this technique could gain wide acceptance.

Ryan, Robert↗

Readout of Large Capacitance SiPMs by Weak Coupling to Charge Sensitive Amplifier

Large area and large capacitance silicon photomultiplier (SiPM) arrays are employed to collect scintillation light in noble liquid time projection chambers (TPC) such as DarkSide, nEXO, MEGII, protoDUNE and DUNE. Light readout using ASICs designed for operation in noble liquids is a solution for large meter-scale photon detectors. However, conventional readout requires a high voltage decoupling capacitor larger than SiPM capacitance (in the range of tens of nF) to achieve full charge transfer to the preamplifier. Here, we demonstrate a readout concept by weakly coupling (via a capacitor lower by an order of magnitude than SiPM capacitance) to a charge sensitive amplifier, LArASIC in this case, without any loss in the signal to noise ratio (S/N). The single-photoelectron detection, signal-to-noise ratio, timing resolution, and coincidence detection are experimentally characterized.

47 OTHER INSTRUMENTATION↗

A DECADE of dwarfs: first detection of weak lensing around spectroscopically confirmed low-mass galaxies

We present the first detection of weak gravitational lensing around spectroscopically confirmed dwarf galaxies, using the large overlap between DESI DR1 spectroscopic data and DECADE/DES weak lensing catalogs. A clean dwarf galaxy sample with well-defined redshift and stellar mass cuts enables excess surface mass density measurements in two stellar mass bins ($\log \rm{M}_*=[8.2, 9.2]~M_\odot$ and $\log \rm{M}_*=[9.2, 10.2]~M_\odot$), with signal-to-noise ratios of $5.6$ and $12.4$ respectively. This signal-to-noise drops to $4.5$ and $9.2$ respectively for measurements without applying individual inverse probability (IIP) weights, which mitigates fiber incompleteness from DESI's targeting. The measurements are robust against variations in stellar mass estimates, photometric shredding, and lensing calibration systematics. Using a simulation-based modeling framework with stellar mass function priors, we constrain the stellar mass-halo mass relation and find a satellite fraction of $\simeq 0.3$, which is higher than previous photometric studies but $1.5σ$ lower than $Λ$CDM predictions. We find that IIP weights have a significant impact on lensing measurements and can change the inferred $f_{\rm{sat}}$ by a factor of two, highlighting the need for accurate fiber incompleteness corrections for dwarf galaxy samples. Our results open a new observational window into the galaxy-halo connection at low masses, showing that future massively multiplexed spectroscopic observations and weak lensing data will enable stringent tests of galaxy formation models and $Λ$CDM predictions.

To, Chun-Hao [Chicago U., Astron. Astrophys. Ctr.;↗

A review of multiple amplitude-phase digital signals

This paper reviews the data rate, error rate, and signal-to-noise ratio relationship for various uncoded M-ary digital amplitude modulation (AM), phase modulation (PM), and combined AM-PM systems. These signal systems have the common virtue that expanding the number of possible signals to be transmitted increases the data rate but not the bandwidth. A general treatment of the error rate of M-ary digital AM-PM permits development of a simple yet accurate expression which approximates the increase in average signal-to-noise ratio (over that of binary phase shift keying) required for constant error performance. This equation provides insight into why arrays differ in their signal-to-noise ratio requirements.

Smith, J. G.↗

Hypothesis tests for the detection of constant speed radiation moving sources

Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examination of time series through randomly broken windows

The effect of irregular interruption of data collection (the breaking of the window function) on the spectrum determination of a time series is investigated. It is assumed that there is a uniform probability p that each interval of length tau, of the total interval of length T = tau, yields no data. For the linear case (Fourier transform) it is found that the noise to signal ratio has a (one sigma) value less than epsilon if N exceeds p(-1) (1-p) epsilon (-2). For the quadratic case, the same requirement is met by the less restrictive requirement that N exceed p(-1) (1-p) epsilon (-1). It appears that, if four observatories spaced around the Earth were to operate for 25 days, each for six hours a day (N = 100), and if the probability of cloud cover at any site on any day is 20% (p = 0.8), the r.m.s. noise to signal ratio is 0.25% for frequencies displaced from a sharp strong signal by 15 micro Hz. The noise to signal ratio drops off rapidly if the frequency offset exceeds 15 micro Hz.

Sturrock, P. A.↗