Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Recent Updates to the FAUST Array

Current advances in technology have enabled dramatic improvements to the performance of multi-detector arrays within the last 10 years. FAUST is a forward array of 68 Si-CsI(Tl) detector telescopes that has been in use since 1996. To take full advantage of current technology, FAUST has undergone an overhaul installing new preamplifiers from Zepto Systems and modifications to allow for Dual-Axis Dual-Lateral position sensitive detectors to be installed. A new calibration software package has also been developed utilizing a novel linearization algorithm. The combination of these upgrades has led to isotopic identification for elements in the Z = 1-13 range and has greatly increased the angular resolution of the array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Fast Event Preprocessor and Sequencer for the Simbol-X Low Energy Detector

The Simbol-X Low Energy Detector (LED), a 128x128 pixel DEPFET (Depleted Field Effect Transistor) array, will be read out at a very high rate (8000 frames/second) and, therefore, requires a very fast on board electronics. We present an FPGA-based LED camera electronics consisting of an Event Preprocessor (EPP) for on board data preprocessing and filtering of the Simbol-X low-energy detector and a related Sequencer (SEQ) to generate the necessary signals to control the readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study

Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission, ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV, iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW < or approx. 30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simbol-X Mirror Module Thermal Shields: I - Design and X-Ray Transmission

The Simbol-X mission is designed to fly in formation flight configuration. As a consequence, the telescope has both ends open to space, and thermal shielding at telescope entrance and exit is required to maintain temperature uniformity throughout the mirrors. Both mesh and meshless solutions are presently under study for the shields. We discuss the design and the X-ray transmission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of the Simbol-X Telescope

We have developed a simulation tool for a Wolter I telescope operating in formation flight. The aim is to understand and predict the behavior of the Simbol-X instrument. As the geometry is variable, formation flight introduces new challenges and complex implications. Our code, based on Monte Carlo ray tracing, computes the full photon trajectories up to the detector plane, along with the relative drifts of the two spacecrafts. It takes into account angle and energy dependent interactions of the photons with the mirrors and applies to any grazing incidence telescope. The resulting images of simulated sources from 0.1 keV to 100 keV allow us to optimize the configuration of the instrument and to assess the performance of the Simbol-X telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Simbol-X Event Simulator

The ASI Science Data Center (ASDC) has developed an X-ray event simulator to support users (and team members) in simulation of data taken with the two cameras on board the Simbol-X X-Ray Telescope. The Simbol-X simulator is very fast and flexible, compared to ray-tracing simulator. These properties make our simulator advantageous to support the user in planning proposals and comparing real data with the theoretical expectations and for a quick detection of unexpected features. We present here the simulator outline and a few examples of simulated data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formation Flying and Deformable Instruments

Astronomers have always attempted to build very stable instruments. They fight all that can cause mechanical deformation or image motion. This has led to well established technologies (autoguide, active optics, thermal control, tip/tilt correction), as well as observing methods based on the use of controlled motion (scanning, micro scanning, shift and add, chopping and nodding). Formation flying disturbs this practice. It is neither possible to reduce the relative motion to very small amplitudes, nor to control it at will. Some impacts on Simbol-X instrument design, and operation are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging Performance Analysis of Simbol-X with Simulations

Simbol-X is an X-Ray telescope operating in formation flight. It means that its optical performances will strongly depend on the drift of the two spacecrafts and its ability to measure these drifts for image reconstruction. We built a dynamical ray tracing code to study the impact of these parameters on the optical performance of Simbol-X (see Chauvin et al., these proceedings). Using the simulation tool we have developed, we have conducted detailed analyses of the impact of different parameters on the imaging performance of the Simbol-X telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background Rejection of Charged Particles in the Simbol-X Telescope: Preliminary Study of Protons Scattering

X-ray telescopes equipped with focusing optics in high eccentric orbit, as e.g. Newton-XMM and Chandra, showed a degradation of the detector performance and an important increase of the noise due to soft protons with energy between a few tens of keV and a few MeV, that are focused on the detector through the mirror module. It should be noted that the focusing of the protons by Wolter optics was an unexpected phenomenon. In Simbol-X a magnetic diverter will be implemented to deflect protons, in order to reduce the flux of charged particles impinging upon the focal plane. Obviously the design of the diverter should take into consideration the protons distribution at the exit of the mirror module; for this reason a detailed simulation about the interaction of particles with the mirror surface is necessary. Here we will present the scattering protons models currently under consideration, suggesting a preliminary solution for the design of the magnetic diverter. We will also discuss an ad hoc experiment to study this problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Simbol-X Anticoincidence

The Simbol-X telescope will be constitued by two satellites in formation flight. One will host the mirror module and the other the detector payload. This payload will be built with two main detectors able to measure the position, energy and arrival time of each focused photon, between 0.5 and 80 keV. The high sensitivity required by Simbol-X will necessitate low noise background detectors. To achieve this goal, those detectors will be surrounded by a passive graded shield, aimed to stop the out of field of view photons, and an active anticoiencidence system to tag the passing particles. This anticoiencidence detector, whose conception, optimisation and realization are under responsibility of the APC Laboratory, Paris, is based on plastic scintillator plates associated to multi-anodes photo-multipliers via optical fibers. In this paper, we will present the present status of the anticoiencidence system and its expected performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simbol-X Telescope Scientific Calibrations: Requirements and Plans

The Simbol-X telescope characteristics and the mission scientific requirements impose a challenging calibration plan with a number of unprecedented issues. The 20 m focal length implies for the incoming X-ray beam a divergence comparable to the incidence angle of the mirror surface also for 100 m-long facilities. Moreover this is the first time that a direct focussing X-ray telescope will be calibrated on an energy band covering about three decades, and with a complex focal plane. These problems require a careful plan and organization of the measurements, together with an evaluation of the calibration needs in terms of both hardware and software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Small Oscillations on the Effective Area

We analyze the effective area of the Simbol-X mirrors as a function of the off-axis angle for small oscillations. A reduction is expected due to: 1) geometrical effects, because some of the photons miss the secondary mirror surface; 2) reflectivity effects, caused by the variation of the coating reflectivity with the incidence angle. The former are related to the length of the two mirror surfaces, and can be reduced by making the secondary mirror longer. The second ones are energy-dependent, and strongly related to the characteristics of the reflecting coating. These effects are analyzed by means of ray-tracing simulations in order to optimize the mirror and coating design, aiming to improve the effective area stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nine Years of XMM-Newton Pipeline: Experience and Feedback

The Strasbourg Astronomical Observatory is member of the Survey Science Centre (SSC) of the XMM-Newton satellite. Among other responsibilities, we provide a database access to the 2XMMi catalogue and run the part of the data processing pipeline performing the cross-correlation of EPIC sources with archival catalogs. These tasks were all developed in Strasbourg. Pipeline processing is flawlessly in operation since 1999. We describe here the work load and infrastructure setup in Strasbourg to support SSC activities. Our nine year long SSC experience could be used in the framework of the Simbol-X ground segment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simbol-X Core Science in a Context

Taking advantage of emerging technology in mirror manufacturing and spacecraft formation flying, Simbol-X will push grazing incidence imaging up to {approx}80 keV, providing an improvement of roughly three orders of magnitude in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. This will open a new window in X-ray astronomy, allowing breakthrough studies on black hole physics and census and particle acceleration mechanisms. We discuss here synergies between Simbol-X and the main multiwavelength facilities that will operate in the next decade, and present a quantitative comparison between Simbol-X and its main competitors, NuStar and Astro-H.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of {sup 10}B-Based {sup 3}He Replacement Neutron Detectors

Radiation portal monitors (RPM) are currently deployed at United States border crossings to passively inspect vehicles and persons for any emission of neutrons and/or gamma rays, which may indicate the presence of unshielded nuclear materials. The RPM module contains an organic scintillator with {sup 3}He proportional counters to detect gamma rays and thermalized neutrons, respectively. The supply of {sup 3}He is rapidly dwindling, requiring alternative detectors to provide the same function and performance. Our alternative approach is one consisting of a thinly-coated {sup 10}B flat-panel ionization chamber neutron detector that can be deployed as a direct drop-in replacement for current RPM {sup 3}He detectors. The uniqueness of our approach in providing a large-area detector is in the simplicity of construction, scalability of the unit cell detector, ease of adaptability to a variety of applications and low cost. Currently, Rapiscan Laboratories and Helicon Thin Film Systems have designed and developed an operational 100 cm{sup 2} multi-layer prototype {sup 10}BB-based ionization chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{sup 25}Na and {sup 25}Mg fragmentation on {sup 12}C at 9.23 MeV per nucleon at TRIUMF

HERACLES is a multidetector that is used to study heavy-ion collisions, with ion beams with an energy range between 8 to 15 MeV per nucleon. It has 78 detectors axially distributed around the beam axis in 6 rings allowing detection of multiple charged fragments from nuclear reactions. HERACLES has 4 different types of detectors, BC408/BaF{sub 2} phoswich, Si/CsI(Tl) telescope, BC408/BC444 phoswich and CsI(Tl) detectors. The multidetector has been run with a radioactive {sup 25}Na beam and a stable {sup 25}Mg beam at 9.23 MeV per nucleon on a carbon target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the KM3NeT photomultipliers in the Hellenic Open University

The KM3NeT neutrino research infrastructure will be a deep sea multidisciplinary observatory in the Mediterranean Sea hosting a neutrino telescope. The Physics Laboratory of the Hellenic Open University is involved in the characterization of the KM3NeT neutrino detector. The present work describes measurement techniques for the functional characteristics of the candidate KM3NeT photomultipliers. These characteristics include dark current, transit time spread, gain slope and single photoelectron characteristics, as well as delayed and after pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ATLAS Tile Calorimeter

TileCal is the Hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). The resulting electronic signals from the approximately 10000 PMTs are measured and digitised every 25 ns before being transferred to off-detector data-acquisition systems. This contribution will review in a first part the performances of the calorimeter during run 1, obtained from calibration data, and from studies of the response of particles from collisions. In a second part it will present the solutions being investigated for the ongoing and future upgrades of the calorimeter electronics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗