Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

The spectral energy distributions of Fermi blazars

In this paper, multiwavelength data are compiled for a sample of 1425 Fermi blazars to calculate their spectral energy distributions (SEDs). A parabolic function, log(νF{sub ν})=P{sub 1}(logν−P{sub 2}){sup 2}+P{sub 3}, is used for SED fitting. Synchrotron peak frequency (logν{sub p}), spectral curvature (P{sub 1}), peak flux (ν{sub p}F{sub ν{sub p}}), and integrated flux (νF{sub ν}) are successfully obtained for 1392 blazars (461 flat-spectrum radio quasars [FSRQs], 620 BL Lacs [BLs], and 311 blazars of uncertain type [BCUs]; 999 sources have known redshifts). Monochromatic luminosity at radio 1.4 GHz, optical R band, X-ray at 1 keV and γ-ray at 1 GeV, peak luminosity, integrated luminosity, and effective spectral indices of radio to optical (α{sub RO}) and optical to X-ray (α{sub OX}) are calculated. The “Bayesian classification” is employed to log ν{sub p} in the rest frame for 999 blazars with available redshift, and the results show that three components are enough to fit the log ν{sub p} distribution; there is no ultra-high peaked subclass. Based on the three components, the subclasses of blazars using the acronyms of Abdo et al. are classified, and some mutual correlations are also studied. Conclusions are finally drawn as follows: (1) SEDs are successfully obtained for 1392 blazars. The fitted peak frequencies are compared with common sources from available samples. (2) Blazars are classified as low synchrotron peak sources if log ν{sub p}(Hz)⩽14.0, intermediate synchrotron peak sources if 14.0< log ν{sub p}(Hz)⩽15.3, and high synchrotron peak sources if log ν{sub p}(Hz)>15.3. (3) Gamma-ray emissions are strongly correlated with radio emissions. Gamma-ray luminosity is also correlated with synchrotron peak luminosity and integrated luminosity. (4) There is an anticorrelation between peak frequency and peak luminosity within the whole blazar sample. However, there is a marginally positive correlation for high synchrotron peak BL Lacs (HBLs), and no correlations for FSRQs or low synchrotron peak BL Lacs (LBLs). (5) There are anticorrelations between the monochromatic luminosities (γ-ray and radio bands) and the peak frequency within the whole sample and BL Lacs. (6) The optical to X-ray (α{sub OX}) and radio to optical (α{sub RO}) spectral indices are strongly anticorrelated with peak frequency (log ν{sub p}) within the whole sample, but the correlations for subclasses of FSRQs, LBLs, and HBLs are different.

79 ASTRONOMY AND ASTROPHYSICS↗

A Signature in HIV-1 Envelope Leader Peptide Associated with Transition from Acute to Chronic Infection Impacts Envelope Processing and Infectivity

Mucosal transmission of the human immunodeficiency virus (HIV) results in a bottleneck in viral genetic diversity. Gnanakaran and colleagues used a computational strategy to identify signature amino acids at particular positions in Envelope that were associated either with transmitted sequences sampled very early in infection, or sequences sampled during chronic infection. Among the strongest signatures observed was an enrichment for the stable presence of histidine at position 12 at transmission and in early infection, and a recurrent loss of histidine at position 12 in chronic infection. This amino acid lies within the leader peptide of Envelope, a region of the protein that has been shown to influence envelope glycoprotein expression and virion infectivity. We show a strong association between a positively charged amino acid like histidine at position 12 in transmitted/founder viruses with more efficient trafficking of the nascent envelope polypeptide to the endoplasmic reticulum and higher steady-state glycoprotein expression compared to viruses that have a non-basic position 12 residue, a substitution that was enriched among viruses sampled from chronically infected individuals. When expressed in the context of other viral proteins, transmitted envelopes with a basic amino acid position 12 were incorporated at higher density into the virus and exhibited higher infectious titers than did non-signature envelopes. These results support the potential utility of using a computational approach to examine large viral sequence data sets for functional signatures and indicate the importance of Envelope expression levels for efficient HIV transmission.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of co-circulating pathogens and microbiome from COVID-19 infections

Co-infections or secondary infections with SARS-CoV-2 have the potential to affect disease severity and morbidity. Additionally, the potential influence of the nasal microbiome on COVID-19 illness is not well understood. In this study, we analyzed 203 residual samples, originally submitted for SARS-CoV-2 testing, for the presence of viral, bacterial, and fungal pathogens and non-pathogens using a comprehensive microarray technology, the Lawrence Livermore Microbial Detection Array (LLMDA). Eighty-seven percent of the samples were nasopharyngeal samples, and 23% of the samples were oral, nasal and oral pharyngeal swabs. We conducted bioinformatics analyses to examine differences in microbial populations of these samples, as a proxy for the nasal and oral microbiome, from SARS-CoV-2 positive and negative specimens. We found 91% concordance with the LLMDA relative to a diagnostic RT-qPCR assay for detection of SARS-CoV-2. Sixteen percent of all the samples (32/203) revealed the presence of an opportunistic bacterial or frank viral pathogen with the potential to cause co-infections. The two most detected bacteria, Streptococcus pyogenes and Streptococcus pneumoniae , were present in both SARS-CoV-2 positive and negative samples. Human metapneumovirus was the most prevalent viral pathogen in the SARS-CoV-2 negative samples. Sequence analysis of 16S rRNA was also conducted to evaluate bacterial diversity and confirm LLMDA results.

59 BASIC BIOLOGICAL SCIENCES↗

A satellite digital controller or 'play that PID tune again, Sam'

The problem discussed is to design a digital controller for a typical satellite. The controlled plant is considered to be a rigid body acting in a plane. The controller is assumed to be a digital computer which, when combined with the proposed control algorithm, can be represented as a sampled-data system. The objective is to present a design strategy and technique for selecting numerical values for the control gains (assuming position, integral, and derivative feedback) and the sample rate. The technique is based on the parameter plane method and requires that the system be amenable to z-transform analysis.

Seltzer, S. M.↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II

In this work, we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.

36 MATERIALS SCIENCE↗

Thermal measurement apparatus and methods for anisotropic thermal materials

A system for characterizing thermal properties of thermally anisotropic heterogeneous samples includes a heating element, a first temperature sensing device, a second temperature sensing device, and a computing system. The heating element is positioned at a first location within a sample and heats the sample. The first temperature sensing device outputs data indicative of temperatures of the first location to the computing device. The second temperature sensing device outputs data indicative of temperatures of the second location to the computing device. The computing device computes a thermal conductivity of the sample based upon the temperatures of the first location. The computing device further outputs an indication of a portion of the sample to which the thermal conductivity pertains based upon the second temperatures.

Reyes, Karla Rosa↗

Thermal measurement apparatus and methods for anisotropic thermal materials

A system for characterizing thermal properties of thermally anisotropic heterogeneous samples includes a heating element, a first temperature sensing device, a second temperature sensing device, and a computing system. The heating element is positioned at a first location within a sample and heats the sample. The first temperature sensing device outputs data indicative of temperatures of the first location to the computing device. The second temperature sensing device outputs data indicative of temperatures of the second location to the computing device. The computing device computes a thermal conductivity of the sample based upon the temperatures of the first location. The computing device further outputs an indication of a portion of the sample to which the thermal conductivity pertains based upon the second temperatures.

Reyes, Karla Rosa↗

Method Development for Multiplex, In-Situ, and Real-Time Detection of Herpesvirus Reactivation in Spaceflight Crews using Nanopore Sequencing

Reactivation of latent herpesviruses in crews onboard the International Space Station (ISS) is a well-established spaceflight-associated phenomenon and has been linked to overall immune stress. Beyond an indicator of an altered immune state, this stress-induced reactivation of viruses such as herpesvirus simplex virus 1 (HSV-1), Epstein-Barr virus (EBV), and Varicella-Zoster virus (VZV) may cause clinical symptoms in crew. There is currently no established protocol for in-flight monitoring, and samples are analyzed post-flight using ground-based assays. A real-time, in-flight method for herpesvirus detection followed by stress-mitigation strategies would be a significant advance. In this study, we developed a real-time assay for the multiplex detection of HSV-1, EBV, and VZV from saliva that could be implemented for in-situ monitoring of ISS crew. This method builds on previously validated spaceflight-compatible portable molecular protocols and platforms, such as the miniPCR thermal cycler and the MinION sequencer. Since a metagenomic approach is not currently permitted for crew samples (NASA policy), we employed multiplexing-ready primers directed toward targeted regions within the HSV-1, EBV, and VZV genomes. We also used primers for the human gene, Statherin (STATH), as an internal control. These primers were validated using spiked-in, positive control HSV-1, EBV, and VZV from virus-negative saliva extracted using the Zymo-Research Quick-DNA/RNA Viral MagBead Kit. The PCR Barcoding Kit was used to prepare DNA libraries that were then sequenced on the MK1C and analyzed against known reference genomes using minimap2. Following validation of this method with spiked saliva samples, suspected herpesvirus-positive clinical saliva samples were successfully tested. Prior to use onboard the ISS, this method will be deployed to an analog environment during overwintering at Palmer Station, Antarctica in 2023. This work represents the successful application of molecular technologies currently onboard the ISS for the real-time monitoring of latent herpesvirus reactivation from saliva samples. This assay, in combination with stress-reduction strategies, holds the potential to manage herpesvirus reactivation in ISS crew, thereby improving health outcomes and overall immunity.

Patrick M. Rydzak↗

Countering sensor drift in x-ray micrscopy with fast and robust optimal control

In X-ray microscopy it is imperative that the relative position between the optics stage, that carries the X-ray focusing optics, and the sample stage follow a certain trajectory while either the optics or sample stage is being scanned. Main challenges in achieving this requirement include - open loop drift, environmental disturbance, measurement noise, sensor drift, and control hardware limit. The state-of-the-art in X-ray microscopy at Advanced Photon Source (APS) at Argonne National Laboratory (ANL) features an H ∞ control architecture applied to only the optics stage or both the optics and sample stage, achieving the objectives of large tracking bandwidth over 200 Hz, good positioning resolution on the order of nanometers, rejection of environmental disturbance, attenuation of measurement noise, good Xray diffraction image resolution and increased imaging bandwidth. However, an unaddressed issue in our existing robust control design is that the sensors and the fixtures that hold the sensors drift with time due to changing air temperature in the APS beamline. Since the drift of sensor itself is not measured, it affects the relative position between the focusing optics and sample resulting into imaging artifacts and reduced image resolution. In this article, we demonstrate the rejection of the sensor drift by directly measuring the displacement of the sensor with respect to the global reference frame. Both the measured sensor displacement (i.e. sensor drift) and optics stage displacement are incorporated in the H ∞ control architecture to achieve the above mentioned objectives in addition to minimal relative displacement between the optics stage and the sample stage. This will improve the Xray image resolution and reduce image artifacts.

Robust Control↗

Genome-resolved metagenomics and metatranscriptomics of microbial communities in three meander-bound floodplain soils along the East River, Colorado.

This dataset comprises paired environmental and genomic data for soil samples collected across meander-bound floodplains G (ERMG), L (ERML) and Z (ERMZ). A total of 96 soil samples (32 per floodplain) from the ~ 10-25 cm layer were collected in September 2015, during base flow conditions. An additional 32 soil samples were collected from ERML in September 2016, including three samples from a depth just above the water table. A subset of samples (14) collected in 2016 were used for metatranscriptomics as well as metagenomics. The data package includes: 1) A spread sheet with sample names, location and depth by meander-bound floodplain. 2) Total organic carbon (TOC), total inorganic carbon (TIC), total carbon (TC = TOC + TIC), total nitrogen (TN), and the TOC to TN ratio (TOC:N) from 2015 subsamples. 3) Soil chemistry for 2016 subsamples. 4) A spread sheet with elevation, Easting, Northing, and topographic position index (TPI) for each site sampled in 2015. 5) A kml file, which can be viewed in Google Earth, with the locations of the 96 soil sampling sites along the East River Watershed Floodplain in Colorado. Metagenomics and metatranscriptomics data, as well as reconstructed genomes, are available elsewhere (see data package methods and bioRxiv preprint for links to the data). 6) Two sets of reconstructed genomes with overlapping members (see bioRxiv preprint for description and associated data). Metagenomes and metatranscriptomes are available elsewhere (see data package methods and bioRxiv preprint). To view tar.gz files, the following software can be used: https://www.gnu.org/software/tar/, https://www.7-zip.org/.

54 ENVIRONMENTAL SCIENCES↗

Estimation of Soil Radon Concentration in Al-Qateef's Date Palm Farms, Saudi Arabia

This study involves the measurement of radon concentrations in agricultural soil from two date Palm farms in Al-Qateef province using CR-39 detector. In each farm the palm trees are arranged in rows separated by the irrigation reservoirs. The first farm is about 10000 m{sup 2} and has 350 palm trees and the second farm is about 7000 m{sup 2} and has 320 palm trees. The average distance between trees is about 5.5 m. The rows are separated by an irrigation reservoir where fertilizers are added. Sixty soil samples were collected from each farm and classified in paperboard boxes. These samples were taken from different depths and positions between the trees and from the irrigation reservoir.A newly designed tag type dosimeter is used in which the alpha tracks are registered on both sides of the CR-39 detector. The tag dosimeter was calibrated against a cup type dosimeter which was calibrated at the National Radiological Protection Board (NRPB) at the U.K.The detectors were left to count for five months and then chemically treated in the standard way. Finally an optical microscope is used to count alpha tracks and the data are treated statistically.The study is set to test for significant differences in radon concentrations at different positions and depths in the barren and fertilized soils in the two farms. Measured radon concentrations ranged between 42 and 344Bq/m{sup 3}. No significant difference between the mean concentration values in soil samples taken between the trees and that taken at the depth of 50 cm from the irrigation reservoir. Significant difference was however found between radon concentrations in samples collected directly from the surface of the irrigation reservoir where fertilizers are introduced and those taken from the other two positions. The used fertilizers are found to have higher contents of uranium which is limited to the surface soil of the irrigation reservoir.

54 ENVIRONMENTAL SCIENCES↗

Structural and magnetotransport properties of the Y doped A-site deficient double layered manganites La{sub 1.2−x}□{sub 0.2}Y{sub x}Ca{sub 1.6}Mn{sub 2}O{sub 7}

We present structural, magnetic and electrical properties of the polycrystalline A-site-deficient yttrium doped double layered manganites La{sub 1.2−x}□{sub 0.2}Y{sub x}Ca{sub 1.6}Mn{sub 2}O{sub 7} (x=0.2, 0.3 and 0.4) prepared by a solid state reaction method. The samples crystallize in the tetragonal structure with the space group I4/mmm. Doping with Y decreases the cell parameters and causes a decrease of the metal-insulator transition temperature. The same evolution with doping is also seen for the deduced Curie temperature from susceptibility curves which present a clear paramagnetic-ferromagnetic transition. The significant positive intrinsic magnetoresistance, shown in all samples, reaches 85% at 122 K under 7 T for 0.3 doped sample and can be attributed to the suppression of spin fluctuations via aligning the spins under external magnetic field, while the extrinsic one is attributed to the inter-grain spin-polarized tunneling across the grain boundaries. The simulation of the resistivity curves in the entire temperature range show that the percolation model is suitable to fit our results. The applied magnetic field increases the density of states near the Fermi level, which is in accordance with the observed decrease of resistivity. - Graphical abstract: Resistivity and magnetoresistance of La{sub 1.2−x}□{sub 0.2}Y{sub x}Ca{sub 1.6}Mn{sub 2}O{sub 7} (x=0.2, 0.3, 0.4). Solid lines correspond to the fitting results. Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Extraction with Sub-sampled Line-Spread Functions

STIS long-slit medium resolution spectra reduced in CALSTIS extended-source mode with narrow extraction heights (GWIDTH=3 pixels) show photometric uncertainties of +/- 3% relative to point-source extractions. These uncertainties are introduced through interpolation in the spectral image rectification processing stage, and are correlated with the number of pixel crossings the spectral profile core encounters in the spatial direction. The line-spread-function may be determined as a function of pixel crossing- position from calibration data sub-sampled in the spatial direction. This line spread function will be applied to science data to perform optimal extractions and point- source de-blending. Wavelength and breathing effects will be studied. Viability of the method to de-convolve extended source 'blobs' will be investigated.

Collins, Nicholas R.↗

Nevada Higher Education Benefits from US Department of Energy (DOE) Environmental Management (EM) Nevada Program's Transfer of Geologic Samples - 20442

The Nevada National Security Site (NNSS), formerly the Nevada Test Site, was the location of 100 historic atmospheric and 828 historic underground nuclear tests from 1951 to 1992. Related to this historic nuclear testing, geologic and hydrologic studies of the site were conducted utilizing the skills and the expertise of the U.S. Geological Survey (USGS) and national laboratories (Los Alamos National Laboratory, Lawrence Livermore National Laboratory), who were principal in leading the development of weapons and were responsible for specific underground testing programs. The subsurface samples and technical/scientific data associated with NNSS geologic studies (past and present) are preserved and stored at the USGS Mercury Core Library and Data Center located at the NNSS. Currently, the facility stores over 2,000,000 linear feet of cores and cuttings from more than 2,600 drill holes that can be accessed for study. Most of the samples and historic geologic work was focused directly on subsurface geologic settings that relate directly to historic underground nuclear testing. Since 1992, the United States has observed a unilateral moratorium on full-scale nuclear testing, and the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program is now responsible for hydrogeologic characterization of the potential impacts to the natural groundwater systems that may have resulted from historic underground nuclear tests. As part of this effort, the EM Nevada Program Underground Test Area (UGTA) Activity has drilled and completed over 58 deep (2,000 - 7,000 ft.) characterization wells, totaling in excess of 170,000 linear feet of cuttings and core samples. Cutting samples were collected as triplicate samples for each respective depth interval, to account for potential later nondestructive/destructive analysis and to preserve samples for regulatory purposes. Recently, it was recognized by the EM Nevada Program that opportunities may exist to reduce the cost and floor space required for the storage of geologic samples at the Mercury Core Library without impacting the integrity and representative nature of the samples necessary for project execution. An initiative was sponsored by EM Nevada Program to evaluate several options: 1) disposal of a portion of cuttings and cores in a land fill setting; 2) reduction in sample volume through skeletonizing core and cuttings from wells to a representative but much smaller number of samples; and 3) solicit potential interest in the academic community where other geoscientists could freely access the samples for studies. The Nevada state university system through the Nevada Bureau of Mines and Geology responded positively to the opportunity to receive these NNSS samples from the EM Nevada Program. In June 2019, approximately 17,000 geologic samples, representing greater than 170,000 linear feet of drilling and weighing over 20,000 pounds, were shipped from the NNSS to the Great Basin Science Sample and Records Library located in Reno, Nevada. The benefits resulting from this transfer were realized by the EM Nevada Program in terms of cost and space savings for geologic sample storage at the NNSS. The transfer did not impact the EM Nevada Program mission as access to representative geologic samples for regulatory and scientific purposes was preserved. Moreover, the Nevada Bureau of Mines and Geology acquired a significant resource of subsurface geologic samples and supporting technical data to support academic and scientific studies in a complex volcanic setting in southwest Nevada. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An instrument for spatial conductivity measurements of high Tc superconducting (HTSC) materials

High T(sub c) Superconducting (HTSC) thin films are suggested for use in a number of aerospace applications such as an IR bolometer and as electromagnetic shielding. As part of its flight assurance role, the Materials Branch of the Goddard Space Flight Center has initiated development of an instrument capable of measuring variations in conductivity for flat samples using an eddy current testing device and an X-Y positioning table. This instrument was used to examine bulk HTSC samples. System changes that would enable characterization of thin film materials are discussed.

Vansant, T.↗

High Resolution Spectroscopy of Vega-like Stars: Abundances and Circumstellar Gas

Vega-like stars are main-sequence stars exhibiting excess infrared emission. In an effort to improve the information available on this class of star, 13 stars have been analyzed which have been classed as Vega-like, or have an infra-red excess attributable to dust in their circumstellar environment. In a separate paper stellar properties such as effective temperature and log g have been derived and in this poster we highlight the results of the photospheric abundance analysis also carried out during this work. King recently drew attention to the possible link between Vega-like stars and the photospheric metal-depleted class of A-stars, the Lambda Bootis stars. Since Vega-like stars are thought to have disks of dust, it might be expected that accretion of depleted gas onto the surface of these stars may cause this same phenomenon. In the 6 stars studied for depletions, none showed the extreme underabundance patterns observed in Lambda Bootis stars. However, depletions of silicon and magnesium were found in two of the sample, suggesting that these elements are in silicate dust grains in the circumstellar environment of these stars. Absorption lines attributed to circumstellar gas have been positively identified in three stars in our sample. Individual cases show evidence either of high-velocity outflowing gas, variability in the circumstellar lines observed, or evidence of circumstellar gas in excited lines of Fe II. No previous identification of circumstellar material has been made for two of the stars in question.

Dunkin, S. K.↗

Hall Effect Thruster Plume Contamination and Erosion Study

The objective of the Hall effect thruster plume contamination and erosion study was to evaluate the impact of a xenon ion plume on various samples placed in the vicinity of a Hall effect thruster for a continuous 100 hour exposure. NASA Glenn Research Center was responsible for the pre- and post-test evaluation of three sample types placed around the thruster: solar cell cover glass, RTV silicone, and Kapton(R). Mass and profilometer), were used to identify the degree of deposition and/or erosion on the solar cell cover glass, RTV silicone, and Kapton@ samples. Transmittance, reflectance, solar absorptance, and room temperature emittance were used to identify the degree of performance degradation of the solar cell cover glass samples alone. Auger spectroscopy was used to identify the chemical constituents found on the surface of the exposed solar cell cover glass samples. Chemical analysis indicated some boron nitride contamination on the samples, from boron nitride insulators used in the body of the thruster. However, erosion outweighted contamination. All samples exhibited some degree of erosion. with the most erosion occurring near the centerline of the plume and the least occurring at the +/- 90 deg positions. For the solar cell cover glass samples, erosion progressed through the antireflective coating and into the microsheet glass itself. Erosion occurred in the solar cell cover glass, RTV silicone and Kapton(R) at different rates. All optical properties changed with the degree of erosion, with solar absorptance and room temperature emittance increasing with erosion. The transmittance of some samples decreased while the reflectance of some samples increased and others decreased. All results are consistent with an energetic plume of xenon ions serving as a source for erosion.

Jaworske, Donald A.↗