Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Characterization of single diamondlike and polymerlike nanoparticles by midinfrared nanospectroscopy

We report on the characterization of single nanoparticles produced in N{sub 2}-C{sub 2}H{sub 2} low pressure plasmas using scanning near-field infrared microscopy. We use a high power optical parametric oscillator as radiation source, which emits in the so-called fingerprint region 2500-3570 cm{sup -1}. We have probed the characteristic N-H absorption band at 3300 cm{sup -1} to characterize single nanoparticles. The observed near-field contrast allows to distinguish between diamond- and polymerlike nanoparticles. Here, the term 'diamondlike' refers to hard amorphous carbon material with abundant sp{sup 3}-coordinated C atoms. Our results demonstrate the feasibility of an infrared spectral characterization of single nanoparticles with nanometer lateral resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-Induced Superintensive Bubble Boiling

Superintensive bubble boiling (SBB) is implemented in water in the absence of degassing at the end surface of a laser fiber using 100-ns laser pulses. A thulium fiber laser with a radiation wavelength of 1.94 μm and moderate power is used as a radiation source. The generation of bubble microjets in the vicinity of the end surface of the laser fiber is studied with the aid of high-speed photography and acoustic methods. After a threshold transition to the SBB regime, the energy of acoustic emission is predominantly concentrated in an acoustic interval of 10–30 kHz. The acoustic signal is generated due to thermal cavitation. Record-high thermal fluxes of up to 0.16 MW/cm{sup 2} are reached in the SBB regime. Parameters of the resulting convective fluxes, microbubbles, and broadband acoustic oscillations are determined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Regulatory Perspective on Potential Fuel Reconfiguration and Its Implication to High Burnup Spent Fuel Storage and Transportation - 13042

The recent experiments conducted by Argonne National Laboratory on high burnup fuel cladding material property show that the ductile to brittle transition temperature of high burnup fuel cladding is dependent on: (1) cladding material, (2) irradiation conditions, and (3) drying-storage histories (stress at maximum temperature) [1]. The experiment results also show that the ductile to brittle temperature increases as the fuel burnup increases. These results indicate that the current knowledge in cladding material property is insufficient to determine the structural performance of the cladding of high burnup fuel after it has been stored in a dry cask storage system for some time. The uncertainties in material property and the elevated ductile to brittle transition temperature impose a challenge to the storage cask and transportation packaging designs because the cask designs may not be able to rely on the structural integrity of the fuel assembly for control of fissile material, radiation source, and decay heat source distributions. The fuel may reconfigure during further storage and/or the subsequent transportation conditions. In addition, the fraction of radioactive materials available for release from spent fuel under normal condition of storage and transport may also change. The spent fuel storage and/or transportation packaging vendors, spent fuel shippers, and the regulator may need to consider this possible fuel reconfiguration and its impact on the packages' ability to meet the safety requirements of Part 72 and Part 71 of Title 10 of the Code of Federal Regulations. The United States Nuclear Regulatory Commission (NRC) is working with the scientists at Oak Ridge National Laboratory (ORNL) to assess the impact of fuel reconfiguration on the safety of the dry storage systems and transportation packages. The NRC Division of Spent Fuel Storage and Transportation has formed a task force to work on the safety and regulatory concerns in relevance to high burnup fuel storage and transportation. This paper discusses the staff's preliminary considerations on the safety implication of fuel reconfiguration with respect to nuclear safety (subcriticality control), radiation shielding, containment, the performance of the thermal functions of the packages, and the retrievability of the contents from regulatory perspective. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-06: Development of a Formalism for Practical Dose Measurements in Brachytherapy in the German Standard DIN 6803

Purpose: In the steep dose gradients in the vicinity of a radiation source and due to the properties of the changing photon spectra, dose measurements in Brachytherapy usually have large uncertainties. Working group DIN 6803-3 is presently discussing recommendations for practical brachytherapy dosimetry incorporating recent theoretical developments in the description of brachytherapy radiation fields as well as new detectors and phantom materials. The goal is to prepare methods and instruments to verify dose calculation algorithms and for clinical dose verification with reduced uncertainties. Methods: After analysis of the distance dependent spectral changes of the radiation field surrounding brachytherapy sources, the energy dependent response of typical brachytherapy detectors was examined with Monte Carlo simulations. A dosimetric formalism was developed allowing the correction of their energy dependence as function of source distance for a Co-60 calibrated detector. Water equivalent phantom materials were examined with Monte Carlo calculations for their influence on brachytherapy photon spectra and for their water equivalence in terms of generating equivalent distributions of photon spectra and absorbed dose to water. Results: The energy dependence of a detector in the vicinity of a brachytherapy source can be described by defining an energy correction factor kQ for brachytherapy in the same manner as in existing dosimetry protocols which incorporates volume averaging and radiation field distortion by the detector. Solid phantom materials were identified which allow precise positioning of a detector together with small correctable deviations from absorbed dose to water. Recommendations for the selection of detectors and phantom materials are being developed for different measurements in brachytherapy. Conclusion: The introduction of kQ for brachytherapy sources may allow more systematic and comparable dose measurements. In principle, the corrections can be verified or even determined by measurement in a water phantom and comparison with dose distributions calculated using the TG43 dosimetry formalism. Project is supported by DIN Deutsches Institut fuer Normung.

60 APPLIED LIFE SCIENCES↗

Relativistic Gas Drag on Dust Grains and Implications

We study the drag force on grains moving at relativistic velocities through interstellar gas and explore its application. First, we derive a new analytical formula of the drag force at high energies and find that it is significantly reduced compared to the classical model. Second, we apply the obtained drag force to calculate the terminal velocities of interstellar grains by strong radiation sources such as supernovae and active galactic nuclei (AGNs). We find that grains can be accelerated to relativistic velocities by very luminous AGNs. We then quantify the deceleration of relativistic spacecraft proposed by the Breakthrough Starshot initiative due to gas drag on a relativistic lightsail. We find that the spacecraft’s decrease in speed is negligible because of the suppression of gas drag at relativistic velocities, suggesting that the lightsail may be open for communication during its journey to α Centauri without causing a considerable delay. Finally, we show that the damage to relativistic thin lightsails by interstellar dust is a minor effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Interstitial rotating shield brachytherapy for prostate cancer

Purpose: To present a novel needle, catheter, and radiation source system for interstitial rotating shield brachytherapy (I-RSBT) of the prostate. I-RSBT is a promising technique for reducing urethra, rectum, and bladder dose relative to conventional interstitial high-dose-rate brachytherapy (HDR-BT). Methods: A wire-mounted 62 GBq{sup 153}Gd source is proposed with an encapsulated diameter of 0.59 mm, active diameter of 0.44 mm, and active length of 10 mm. A concept model I-RSBT needle/catheter pair was constructed using concentric 50 and 75 μm thick nickel-titanium alloy (nitinol) tubes. The needle is 16-gauge (1.651 mm) in outer diameter and the catheter contains a 535 μm thick platinum shield. I-RSBT and conventional HDR-BT treatment plans for a prostate cancer patient were generated based on Monte Carlo dose calculations. In order to minimize urethral dose, urethral dose gradient volumes within 0–5 mm of the urethra surface were allowed to receive doses less than the prescribed dose of 100%. Results: The platinum shield reduced the dose rate on the shielded side of the source at 1 cm off-axis to 6.4% of the dose rate on the unshielded side. For the case considered, for the same minimum dose to the hottest 98% of the clinical target volume (D{sub 98%}), I-RSBT reduced urethral D{sub 0.1cc} below that of conventional HDR-BT by 29%, 33%, 38%, and 44% for urethral dose gradient volumes within 0, 1, 3, and 5 mm of the urethra surface, respectively. Percentages are expressed relative to the prescription dose of 100%. For the case considered, for the same urethral dose gradient volumes, rectum D{sub 1cc} was reduced by 7%, 6%, 6%, and 6%, respectively, and bladder D{sub 1cc} was reduced by 4%, 5%, 5%, and 6%, respectively. Treatment time to deliver 20 Gy with I-RSBT was 154 min with ten 62 GBq {sup 153}Gd sources. Conclusions: For the case considered, the proposed{sup 153}Gd-based I-RSBT system has the potential to lower the urethral dose relative to HDR-BT by 29%–44% if the clinician allows a urethral dose gradient volume of 0–5 mm around the urethra to receive a dose below the prescription. A multisource approach is necessary in order to deliver the proposed {sup 153}Gd-based I-RSBT technique in reasonable treatment times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-BRD-00: New Developments in Hybrid MR-Treatment: Technology

The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.

60 APPLIED LIFE SCIENCES↗

WE-D-BRD-01: New Linac Designs for MR-Guided Therapy Systems

The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.

60 APPLIED LIFE SCIENCES↗

WE-D-BRD-02: Tracking Coils for Brachy MR Guidance

The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.

60 APPLIED LIFE SCIENCES↗

WE-D-BRD-03: Novel Methods and Tools for MR Commissioning and QC

The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.

60 APPLIED LIFE SCIENCES↗

High pressure study of Ti[subscript 4]AlN[subscript 3] to 55 GPa

Using a synchrotron radiation source and a diamond anvil cell, we measured the pressure dependence of the lattice parameters of a polycrystalline Ti{sub 4}AlN{sub 3} sample up to a pressure of 55 GPa. No phase transformations were observed. As observed in Ti{sub 3}SiC{sub 2}, Ti{sub 3}Si{sub 0.5}Ge{sub 0.5}C{sub 2}, and Zr{sub 2}InC, the compressibility of Ti{sub 4}AlN{sub 3} along the c axis was larger than along the a axis which leads to a decrease in the c/a ratio with increasing pressure. The bulk modulus is 216 {+-} 2 GPa, with a pressure derivative of 3.84 {+-} 0.06.

43 PARTICLE ACCELERATORS↗

Surface acoustic wave propagation in graphene film

Surface acoustic wave (SAW) propagation in a graphene film on the surface of piezoelectric crystals was studied at the BESSY II synchrotron radiation source. Talbot effect enabled the visualization of the SAW propagation on the crystal surface with the graphene film in a real time mode, and high-resolution x-ray diffraction permitted the determination of the SAW amplitude in the graphene/piezoelectric crystal system. The influence of the SAW on the electrical properties of the graphene film was examined. It was shown that the changing of the SAW amplitude enables controlling the magnitude and direction of current in graphene film on the surface of piezoelectric crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MicroComputed Tomography: Methodology and Applications

Due to the availability of commercial laboratory systems and the emergence of user facilities at synchrotron radiation sources, studies of microcomputed tomography or microCT have increased exponentially. MicroComputed Technology provides a complete introduction to the technology, describing how to use it effectively and understand its results. The first part of the book focuses on methodology, covering experimental methods, data analysis, and visualization approaches. The second part addresses various microCT applications, including porous solids, microstructural evolution, soft tissue studies, multimode studies, and indirect analyses. The author presents a sufficient amount of fundamental material so that those new to the field can develop a relative understanding of how to design their own microCT studies. One of the first full-length references dedicated to microCT, this book provides an accessible introduction to field, supplemented with application examples and color images.

43 PARTICLE ACCELERATORS↗

Gamma Imaging and Mapping Advancements

The SRNL developed GrayQb{sup TM} gamma mapping system has been successfully deployed in field situations. Currently, to get the image from the GrayQb{sup TM} the internal Phosphor Storage Plate (PSP) used to capture radiation images must be recovered and scanned by a ScanX Scanner. Upgrades are being implemented which will enable the GrayQB{sup TM} to read the PSP using a camera and red LEDs then transmit results to a remote location. This will greatly reduce personnel interaction, increasing safety as well as eliminating the need for the ScanX. Upgrades have been based off of the MiniMax, a Los Alamos National Laboratory developed PSP reading device constructed with a Nikon DSLR and a red LED flash to obtain the images from the PSP. The electronics in the upgraded GrayQb{sup TM} need to be both functional and environmentally rugged. A PC/104 was chosen for its wider operational temperature range and its physical durability. The Sony α7 ii and the Mightex are the candidate cameras for the upgrades based on test results. PSPs were exposed to gamma radiation sources at SRS's Health Physics Instrumentation Calibration Laboratory (HPICL). PSPs were tested with both Am-241 and Cs-137. Linear intensity increased with dose verifying UV image simulations. Data collected enabled the PSP intensity to be referenced to a total dose. Further work includes design and implementation of a 3D printed housing for the new camera system. The housing will include the camera, light flash, PSP holders, tungsten dual pinhole, PC/104, dosimeter, and a battery or tethering option. Once the housing is finalized further testing at the HPICL facility is planned for early August. During this testing, the final housing design will capture both Am-241 and Cs-137 images.

3D PRINTING↗

Robotics for Nuclear Material Handling at LANL:Capabilities and Needs

Nuclear material processing operations present numerous challenges for effective automation. Confined spaces, hazardous materials and processes, particulate contamination, radiation sources, and corrosive chemical operations are but a few of the significant hazards. However, automated systems represent a significant safety advance when deployed in place of manual tasks performed by human workers. The replacement of manual operations with automated systems has been desirable for nearly 40 years, yet only recently are automated systems becoming increasingly common for nuclear materials handling applications. This paper reviews several automation systems which are deployed or about to be deployed at Los Alamos National Laboratory for nuclear material handling operations. Highlighted are the current social and technological challenges faced in deploying automated systems into hazardous material handling environments and the opportunities for future innovations.

42 ENGINEERING↗

Observation of a new electronic state of CO perturbing W{sup 1}Π(υ=1)

We observe photoabsorption of the W(1) ← X(0) band in five carbon monoxide isotopologues with a vacuum-ultraviolet Fourier-transform spectrometer and a synchrotron radiation source. We deduce transition energies, integrated cross sections, and natural linewidths of the observed rotational transitions and find a perturbation affecting these. Following a deperturbation analysis of all five isotopologues, the perturbing state is assigned to the υ = 0 level of a previously unobserved {sup 1}Π state predicted by ab initio calculations to occur with the correct symmetry and equilibrium internuclear distance. We label this new state E{sup ″} {sup 1}Π. Both of the interacting levels W(1) and E{sup ″}(0) are predissociated, leading to dramatic interference effects in their corresponding linewidths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams

Purpose: By using Monte Carlo simulations, the authors investigated the energy and angular dependence of the response of plastic scintillation detectors (PSDs) in photon beams. Methods: Three PSDs were modeled in this study: A plastic scintillator (BC-400) and a scintillating fiber (BCF-12), both attached by a plastic-core optical fiber stem, and a plastic scintillator (BC-400) attached by an air-core optical fiber stem with a silica tube coated with silver. The authors then calculated, with low statistical uncertainty, the energy and angular dependences of the PSDs' responses in a water phantom. For energy dependence, the response of the detectors is calculated as the detector dose per unit water dose. The perturbation caused by the optical fiber stem connected to the PSD to guide the optical light to a photodetector was studied in simulations using different optical fiber materials. Results: For the energy dependence of the PSDs in photon beams, the PSDs with plastic-core fiber have excellent energy independence within about 0.5% at photon energies ranging from 300 keV (monoenergetic) to 18 MV (linac beam). The PSD with an air-core optical fiber with a silica tube also has good energy independence within 1% in the same photon energy range. For the angular dependence, the relative response of all the three modeled PSDs is within 2% for all the angles in a 6 MV photon beam. This is also true in a 300 keV monoenergetic photon beam for PSDs with plastic-core fiber. For the PSD with an air-core fiber with a silica tube in the 300 keV beam, the relative response varies within 1% for most of the angles, except in the case when the fiber stem is pointing right to the radiation source in which case the PSD may over-response by more than 10%. Conclusions: At {+-}1% level, no beam energy correction is necessary for the response of all three PSDs modeled in this study in the photon energy ranges from 200 keV (monoenergetic) to 18 MV (linac beam). The PSD would be even closer to water equivalent if there is a silica tube around the sensitive volume. The angular dependence of the response of the three PSDs in a 6 MV photon beam is not of concern at 2% level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin Polarization Dynamics of Nonequilibrium Conduction Electrons in Magnetic Junctions

The dynamics of the motion of the magnetic moment averaged over an ensemble of nonequilibrium spin-injected electrons in a ferromagnetic junction is considered with allowance for the exchange interaction, as well as the interaction with an external electromagnetic field and a thermostat. The solution of this problem is important for the experimental development of compact terahertz-band radiation sources. The rate of quantum transitions of electrons with opposite spins, which determine the spin relaxation under the interaction with a thermostat, is calculated within the density matrix formalism. It is shown that two spin-relaxation modes can be implemented that correspond to low- and high-Q precession of spin-nonequilibrium injected electrons. The effect of the characteristic features of spin-flip transitions under the relaxation of the magnetic moment on the emission and absorption of photons with-energy corresponding to the energy of effective exchange splitting of spin subbands is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗