Ammonia Absorption Technologies Development for Air Conditioning, Heat Pumping and Refrigeration
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
No abstract prepared.
In the present study, quasi-diabatic two-phase flow pattern visualizations and measurements of elongated bubble velocity, frequency and length were performed. The tests were run for R134a and R245fa evaporating in a stainless steel tube with diameter of 2.32 mm, mass velocities ranging from 50 to 600 kg/m{sup 2} s and saturation temperatures of 22 C, 31 C and 41 C. The tube was heated by applying a direct DC current to its surface. Images from a high-speed video-camera (8000 frames/s) obtained through a transparent tube just downstream the heated sections were used to identify the following flow patterns: bubbly, elongated bubbles, churn and annular flows. The visualized flow patterns were compared against the predictions provided by Barnea et al. (1983), Felcar et al. (2007), Revellin and Thome (2007) and Ong and Thome (2009). From this comparison, it was found that the methods proposed by Felcar et al. (2007) and Ong and Thome (2009) predicted relatively well the present database. Additionally, elongated bubble velocities, frequencies and lengths were determined based on the analysis of high-speed videos. Results suggested that the elongated bubble velocity depends on mass velocity, vapor quality and saturation temperature. The bubble velocity increases with increasing mass velocity and vapor quality and decreases with increasing saturation temperature. Additionally, bubble velocity was correlated as linear functions of the two-phase superficial velocity. (author)
Net-zero energy building (NZEB) design has been gaining widespread acceptance as a major driver to reach feasible long-term goals of energy reductions in a building sector for the coming decades. Accordingly, net-zero energy targets for commercial buildings have been specified by federal and/or local government agencies in U.S. Although moving toward NZEB goals has technically feasible long-term advantages, economic issues are one of primarily concerns by building owners and designers for the application of advanced building technologies in NZEB design of their retrofit or new building construction. However, the lack of life cycle cost (LCC) data has still hindered reliable understanding of adopting NZEB design by building owners in a cost-effective manner. In response to this gap, this study conducts life-cycle cost analysis (LCCA) of NZEB design with an energy-efficient heating, ventilation, and air conditioning (HVAC) system and a solar power generation system. Here, to enable NZEB design, an air-source VRF heat pump (HP) type system is considered for energy-efficient HVAC equipment in an office building model with a grid-tied photovoltaic (PV) system. Results reveal that the LCC of NZEBs varies primarily due to a combined effect of annual site EUIs, on-site power generation, and cost-items of each location in U.S. climates. Some hot and mild climate zones in the U.S. represent that LCC values of NZEBs are considerably lower. In contrast, some other cold zones result in unattractive LCC values for NZEBs, caused by a combined effect of relatively lower potential of on-site PV electricity generation and city cost indices. Yet, with subsidized financing by the federal government for PV installation costs, LCC values of NZEBs become significantly attractive in most climate locations.
No abstract prepared.
The design and operation of an electronic cooler based on a combination of superconducting tunnel junctions is described. The cascade extraction of hot-quasiparticles, which stems from the energy gaps of two different superconductors, allows for a normal metal to be cooled down to about 100 mK starting from a bath temperature of 0.5 K. We discuss the practical implementation, potential performance, and limitations of such a device.
Laser cooling of semiconductors has been an elusive goal for many years, and while attempts to cool the narrow gap semiconductors such as GaAs are yet to succeed, recently, net cooling has been attained in a wider gap CdS. This raises the question of whether wider gap semiconductors with higher phonon energies and stronger electron-phonon coupling are better suitable for laser cooling. In this work, we develop a straightforward theory of phonon-assisted absorption and photoluminescence of semiconductors that involves more than one phonon and use to examine wide gap materials, such as GaN and CdS and compare them with GaAs. The results indicate that while strong electron-phonon coupling in both GaN and CdS definitely improves the prospects of laser cooling, large phonon energy in GaN may be a limitation, which makes CdS a better prospect for laser cooling.
A biased tunnel junction between a superconductor and a normal metal can cool the latter electrode. Based on a recently developed cooler with high power and superior performance, we have integrated it with a dielectric silicon nitride membrane, and cooled phonons from 305 mK down to 200 mK. Without perforation and covered under a thin alumina layer, the membrane is rigorously transformed into a cooling platform that is robust and versatile for multiple practical purposes. We discussed our results and possibilities to further improve the device.
Magnetocaloric and related properties of Ru and Ni substituted (MnFe){sub 2}(PSi) are presented. It is found that Ru and Ni are effective doping elements to reduce the thermal hysteresis of (MnFe){sub 2}(PSi). The origin of the thermal hysteresis is discussed on the basis of a thermodynamic model. It is shown that the elastic energy is responsible for the thermal hysteresis. We also show recent developments of the production process of Mn compounds in an industrial scale.
In this work, we show that aluminium doped with low concentrations of magnetic impurities can be used to fabricate quantum devices with intrinsic cooling capabilities. We fabricate single electron transistors made of aluminium doped with 2% Mn by using a standard multi angle evaporation technique and show that the quantity of metal used to fabricate the devices generates enough cooling power to achieve a drop of 160 mK in the electron temperature at the base temperature of our cryostat (300 mK). The cooling mechanism is based on the magneto-caloric effect from the diluted Mn moments.
Microlaser designs based on the coupling of whispering gallery modes (WGMs) with the upconversion processes which take place within lanthanide-doped nanoparticles (UCNPs) have been demonstrated and shown to have many valuable qualities, such as high Q factors and low lasing thresholds. One obstacle that these microlaser designs still face is the challenges caused by photothermal heating of the gain medium, which could be solved through the design of a radiation balanced microlaser. In this work, WGM microresonators composed of 5 µm diameter polystyrene spheres are fabricated with a layer of Yb3+-doped NaYF4 UCNPs in order to test if the anti-Stokes cooling properties of the UCNPs can cool the microresonator and its environment under laser irradiation. We find via calibrated mean fluorescence spectroscopy that the UCNPs can cool their local environment by as much as 23 °C and significantly reduce the heating of the aqueous environment surrounding the microresonator, showing promise for inclusion in a design for a radiation balanced microlaser.
United Technologies Research Center (UTRC) in collaboration with the University of Illinois Urbana Champaign (UIUC) proposed in 2009 to design, develop and demonstrate a safe, very low global warming potential (GWP) very high performance air-conditioning (VHPAC) residential system. The proposed residential ducted system was targeted to reduce system direct GWP by a factor of approximately 200, and had the potential to achieve a net 4% reduction in overall annual energy consumption of residential buildings.
This document corrects certain values and figures given in the September 2008 version of “Energy Savings Estimates of Light Emitting Diodes in Niche Lighting Applications.”
HVAC systems in the commercial building sector consume about 3.4 quads of energy annually. Of all the HVAC systems, packaged rooftop air–conditioning units (RTUs) provide cooling and heating for over 60 percent of the commercial building floorspace (about 90 billion ft2) in the U.S. and they are a significant source of energy consumption and peak demand. All HVAC systems suffer from faults that impact thermal comfort and increase energy consumption. There are several commercially available Automated Fault Detection and Diagnostic (AFDD) tools on the market that can detect and diagnose faults, and if those faults are corrected, can save significant national energy. However, there are multiple market barriers for these tools including lack of independent verification of their performance in the field in terms of their technical capabilities, ease of use and installation.
Large-scale liquid helium storage and transfer system for ground prechill of Centaur engine components
Explore the source record for details and available documents.