Incremental Gains in Transuranic Activity Analysis in Air Samples for Radiological Emergency Response
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
This article investigates the natural radioactivity of 26 ash samples, laboratory produced from lignite samples collected in the West Macedonia Lignite Center in Northern Greece. The activity concentrations of {sup 40}K, {sup 235}U, {sup 238}U, {sup 226}Ra, {sup 228}Ra, and 232Th were measured by spectroscopy and found four to five times higher than those in the original lignite samples. The radionuclides transfer factors depend on the characteristics of the combustion process and were found higher for {sup 232}Th, {sup 228}Ra, and 40K, because of their closer affinity with the inorganic fraction of the lignite. Compared with other results found in the published literature, the studied ash has relatively high content in radioactivity, but the resulting radiation dose from the radionuclide emissions in the West Macedonia Lignite Center do not contribute significantly to the total effective dose.
Not Available
We report on 14 February 2014, a continuous air monitor (CAM) alarm at the exit of panel 7 in the Waste Isolation Pilot Plant (WIPP) underground facility caused the mine ventilation to shift from unfiltered air over to HEPA filtration for its effluent. Subsequent measurements of the effluent at both pre- and post-HEPA filtration using representative sampling demonstrated that a release had occurred. Using modeling based on measured effluent activity, onsite dose estimates were calculated and later measured via bioassay to be less than 0,1 mSv from intakes of radioactivity. Lastly, the maximum offsite dose potential to nearby dwellings was modeled to be 1 µSv or less, which was consistent with air samples being taken at those dwellings during the release, demonstrating impressive accuracy and precision. No worker or public dose limits have been exceeded, and the release was substantially below the annual release limits for the WIPP site.
This work is a brief overview and comparison of dose rates stemming from both indoor and outdoor natural background radiation and household objects within a suburban environment in North Carolina. Combined gamma and beta dose rates were taken from indoor objects that ranged from the potassium in fruit to the americium in smoke detectors. For outdoor measurements, various height and time data samples were collected to show fluctuations in dose rate due to temperature inversion and geometric attenuation. Although each sample tested proved to have a statistically significant increase over background using Students t-test, no sample proved to be more than a minor increase in natural radiation dose. Furthermore, the relative contributions from natural radioactivity such as potassium in foods and common household items are shown to be easily distinguished from background using standard handheld instrumentation when applied in a systematic, methodological manner.
N/A
The MOBISIC project, funded by the Systematic Paris-Region cluster, is being developed in the context of local crisis (attack bombing in urban environment, in confined space such as an underground train tunnel etc.) or specific event securing (soccer world cup, political meeting etc.). It consists in conceiving, developing and experimenting a mobile, modular ('plug and play') and multi-sensors securing system. In this project, CEA LIST has suggested different solutions for nuclear risks detection and identification. It results in embedding a CZT sensor and a gamma camera in an indoor drone. This article first presents the different modifications carried out on the UAV and different sensors, and focuses then on the experimental performances. (authors)
No abstract prepared.
A particle filter algorithm is presented to estimate the position, strength, and cardinality of an unknown number of radioactive point sources in an obstacle-rich environment using count measurements. The algorithm addresses gaps in the prior literature by incorporating two novel elements. The first is a precomputation step in which local terrain and obstacle data is processed to compute attenuation kernels throughout the search area. This enables rapid estimation performance in obstacle-rich environments as measurements are gathered. The second novel feature is a dynamic particle allocation technique in which the number of particles is adjusted in real time to meet convergence goals. This feature allows the algorithm to scale more efficiently to scenarios with a larger number of sources. Furthermore, a series of computational experiments using simulated data demonstrates the algorithm’s performance in a cluttered environment with up to eight sources.
In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.
This paper presents a parallel log-domain particle filtering algorithm combined with gamma spectrum unfolding to perform localization, identification, and evaluation of multiple point sources of various isotopes in an environment with attenuating obstacles. The method uses sets of precomputed attenuation kernels that map the attenuation characteristics of the environment. These kernels are specific to the energy level of a photopeak of interest. The spectral measurements are deconvolved into count measurements of each photopeak. These count measurements are fed into a set of parallel particle filters using attenuation kernels computed for that photopeak’s energy level. The individual regularized particle filters perform all likelihood calculations in the logarithmic domain to mitigate the effects of particle degeneracy. The output of each particle filter is combined to estimate which isotopes are present as well as their positions and strengths. The performance of the algorithm is characterized in a lab-scale environment using a mobile robot equipped with a gamma ray spectrometer in the presence of up to three different radioactive isotopes simultaneously. The sources were localized to within 10 cm, and their strengths were estimated within 10% of their true values. Furthermore, the isotopes were all correctly identified, and no spurious sources were reported.
Spectroscopic anomaly detection and isotope identification algorithms are integral components in nuclear nonproliferation applications such as search operations. The task is especially challenging in the case of mobile detector systems because the observed gamma-ray background changes more than for a static detector system, and a pretrained background model can easily find itself out of domain. The result is that algorithms may exceed their intended false alarm rate or sacrifice detection sensitivity to maintain the desired false alarm rate. Non-negative matrix factorization (NMF) is a powerful tool for spectral anomaly detection and identification, but, like many similar algorithms that rely on data-driven background models, in its conventional implementation, it is unable to update in real time to account for environmental changes that affect the background spectroscopic signature. Here, we have developed a novel NMF-based algorithm that periodically updates its background model to accommodate changing environmental conditions. The adaptive NMF algorithm involves fewer assumptions about its environment, making it more generalizable than existing NMF-based methods while maintaining or exceeding detection performance on simulated and real-world datasets.
The interpretation of medical images by radiologists is primarily and fundamentally a subjective activity, but there are a number of clinical applications such as tumor imaging where quantitative imaging (QI) metrics (such as tumor growth rate) would be valuable to the patient’s care. It is predicted that the subjective interpretive environment of the past will, over the next decade, evolve toward the increased use of quantitative metrics for evaluating patient health from images. The increasing sophistication and resolution of modern tomographic scanners promote the development of meaningful quantitative end points, determined from images which are in turn produced using well-controlled imaging protocols. For the QI environment to expand, medical physicists, physicians, other researchers and equipment vendors need to work collaboratively to develop the quantitative protocols for imaging, scanner calibrations, and robust analytical software that will lead to the routine inclusion of quantitative parameters in the diagnosis and therapeutic assessment of human health. Most importantly, quantitative metrics need to be developed which have genuine impact on patient diagnosis and welfare, and only then will QI techniques become integrated into the clinical environment.
No abstract prepared.
Purpose: The RPC, established in 1968 has contributed to the development, conduct, and QA of NCI funded multi-institutional cooperative group clinical trials and institutions, primarily in the USA/Canada and 242 other countries, participating in trials. Methods: The RPC QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program included: 1) remote TLD/OSLD audit of machine output, 2) on-site dosimetry review visits, 3) credentialing for advanced technologies, and 4) review of patient treatment records. The RPC presented and published their findings to the radiation oncology community. Results: The number of institutions monitored by the RPC increased from around 1200 in the late 90s, to ∼2000 in 2013. There were over 4000 megavoltage therapy machines and ∼28,000 therapy beams in the 1991 institutions monitored by the RPC by the end of 2013. Within the 14,000 photon, electron and proton beam outputs remotely monitored with TLD/OSLD annually, between 10-20% of the institutions have one or more beams outside the RPC 5% criterion. Dosimetry site visits to photon and proton centers continue to result in 2-4 recommendations affecting key dosimetry parameters that impact patient treatment times. One in four patient treatment records reviewed by the RPC have their dose data corrected by >5% before trial groups use them for outcomes analysis. Twelve of fourteen clinically active proton centers are approved to participate in NCI funded clinical trials. The RPC published 222 peer reviewed articles since 1972. Conclusion: Findings from the RPC suggest that human errors continue to play a role in radiotherapy discrepancies and without the RPC independent QA program, the number of undetected errors and time elapsed before their discovery would have been greater. Work supported by MGH C06 CA059267 and grants CA10953, CA081647 awarded by NCI, DHHS.
Purpose: The authors investigated the changes in the pattern of energy deposition in tissue equivalent phantoms following the introduction of iodinated contrast media. Methods: The phantom consisted of a small “contrast sphere,” filled with water or iodinated contrast, located at the center of a 28 cm diameter water sphere. Monte Carlo simulations were performed using MCNP5 codes, validated by simulating irradiations with analytical solutions. Monoenergetic x-rays ranging from 35 to 150 keV were used to simulate exposures to spheres containing contrast agent with iodine concentrations ranging from 1 to 100 mg/ml. Relative values of energy imparted to the contrast sphere, as well as to the whole phantom, were calculated. Changes in patterns of energy deposition around the contrast sphere were also investigated. Results: Small contrast spheres can increase local absorbed dose by a factor of 13, but the corresponding increase in total energy absorbed was negligible (<1%). The highest localized dose increases were found to occur at incident photon energies of about 60 keV. For a concentration of about 10 mg/ml, typical of clinical practice, localized absorbed doses were generally increased by about a factor of two. At this concentration of 10 mg/ml, the maximum increase in total energy deposition in the phantom was only 6%. These simulations demonstrated that increases in contrast sphere doses were offset by corresponding dose reductions at distal and posterior locations. Conclusions: Adding iodine can result in values of localized absorbed dose increasing by more than an order of magnitude, but the total energy deposition is generally very modest (i.e., <10%). Their data show that adding iodine primarily changes the pattern of energy deposition in the irradiated region, rather than increasing patient doses per se.
No abstract prepared.
Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due to protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.