Measurement of the Fast Neutron Response for {sup 4}He Scintillation Detectors Using a Coincidence Scattering Method

Previous work has measured the neutron response of pressurized {sup 4}He scintillation detectors, however these studies only examine the response as a function of incident neutron energy. Since the detection mechanism in {sup 4}He detectors is elastic scattering, and the interacting neutron will only deposit a fraction of its incident kinetic energy in the detector gas, an examination of the response of the detector output to deposited energy is necessary to transform these detectors into instruments for neutron spectrometry. Using a combined time-of-flight (TOF) and coincidence scattering method, this paper further characterizes the {sup 4}He light response to fast neutrons by examining the scintillation light yield as a function of deposited energy, measuring the light response up to 5 MeV. These {sup 4}He detectors are simple in design, and are manufactured by Arktis Radiation Detectors in several sizes. The specific model used in this experiment had an active volume 20 cm long with an inner diameter of 4.4 cm, giving a total active volume of 304 cm{sup 3}. The key components include the active volume, filled with 150 bar of helium-4 gas, and photomultiplier tubes (PMTs) mounted at either end of the active volume. The detector body is made of stainless steel. The detector response was experimentally measured using a two-detector coincidence arrangement with a {sup 252}Cf source. Two {sup 4}He detectors were vertically mounted, and the source was placed at a horizontal distance from the center of the bottom detector, forming a right angle. By requiring coincidence between the two detectors, it was confirmed that each neutron interacting in the second (top) detector must first have undergone a scattering interaction in the first (bottom) detector, and the time-of-flight (TOF) technique could then be used to determine the energy of the neutron as it traveled between the two detectors by the difference in time between the two detector events. More importantly, with the scattering angle known, the amount of energy deposited by the neutron in the bottom detector (ER) was also calculated using kinematic scattering equations. This deposited recoil energy was then compared to the corresponding light output for each event to form a deposited energy scintillation light response matrix. Similarly, the system's insensitivity to gammas and its ability to reject gammas by pulse shape discrimination (PSD) are often cited as an important advantage, although a detailed analysis of these capabilities has not yet been performed. This work therefore quantified these parameters in order to further characterize these detectors for future mixed radiation field measurements. Gamma sources were measured spanning a range of gamma-ray energies from 0.122 MeV to 1.332 MeV, including {sup 57}Co, {sup 137}Cs, {sup 54}Mn, and {sup 60}Co. Each source was counted by the {sup 4}He detector and the background subtracted. Taking the ratio of the number of events detected during the experimental source measurement to the number of gammas predicted by MCNPX to pass through the detector volume yields the detector's intrinsic gamma efficiency. The difference between this fraction and unity is therefore a measure of the detector's ability to ignore interfering gamma rays, defined as its inherent gamma rejection rate. The ability of post-processing PSD algorithms to further reduce the number of gammas is also investigated and quantified. Finally, it has been noted that the scintillation signal from a single neutron event can be separated in time into two components: the fast component is a sharp peak that exists on the order of nanoseconds; the slow component is a series of smaller pulses, stretched out over four microseconds. Whereas previous research has exclusively focused on the energy information contained in the slow component, this work demonstrates that the fast component is also sensitive to neutron energy, and the entire scintillation signal can therefore be used. In conclusion, the relationship of fast neutron {sup 4}He scintillation detectors to deposited neutron energy was explored, and will be combined with previous works that measured the scintillation response to incident neutron energy in order to develop a neutron spectrometer. Similarly, the ability of these {sup 4}He detectors to reject interfering gamma rays was also quantified, and so will enable this spectrometer to be deployed in mixed radiation field measurements. Finally, while previous works with these detectors have focused on an analysis of the slow scintillation component, it was demonstrated in this work that the fast component also contains significant energy information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tangential Radiotherapy Without Axillary Surgery in Early-Stage Breast Cancer: Results of a Prospective Trial

Purpose: To determine the risk of regional-nodal recurrence in patients with early-stage, invasive breast cancer, with clinically negative axillary nodes, who were treated with breast-conserving surgery, 'high tangential' breast radiotherapy, and hormonal therapy, without axillary surgery or the use of a separate nodal radiation field. Methods and Materials: Between September 1998 and November 2003, 74 patients who were {>=}55 years of age with Stage I-II clinically node-negative, hormone-receptor-positive breast cancer underwent tumor excision to negative margins without axillary surgery as a part of a multi-institutional prospective study. Postoperatively, all underwent high-tangential, whole-breast radiotherapy with a boost to the tumor bed, followed by 5 years of hormonal therapy. Results: For the 74 patients enrolled, the median age was 74.5 years, and the median pathologic tumor size was 1.2 cm. Lymphatic vessel invasion was present in 5 patients (7%). At a median follow-up of 52 months, no regional-nodal failures or ipsilateral breast recurrences had been identified (95% confidence interval, 0-4%). Eight patients died, one of metastatic disease and seven of other causes. Conclusion: In this select group of mainly older patients with early-stage hormone-responsive breast cancer and clinically negative axillary nodes, treatment with high-tangential breast radiotherapy and hormonal therapy, without axillary surgery, yielded a low regional recurrence rate. Such patients might be spared more extensive axillary treatment (axillary surgery, including sentinel node biopsy, or a separate nodal radiation field), with its associated time, expense, and morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of the Scientific Understanding of Radioactive Waste at the U.S. DOE Hanford Site

This paper reviews the origin and chemical and rheological complexity of radioactive waste at the U.S. Department of Energy’s Hanford Site. The waste, stored in underground tanks, was generated via three distinct processes over decades of plutonium extraction operations. Although close records were kept of original waste disposition, tank-to-tank transfers and conditions that impede equilibrium complicate our understanding of the chemistry, phase composition, and rheology of the waste. Tank waste slurries comprise particles and aggregates from nano to micron scales, with varying densities, morphologies, heterogeneous compositions, and complicated responses to flow regimes and process conditions. Further, remnant or changing radiation fields may affect the stability and rheology of the waste. These conditions pose challenges for transport through conduits or pipes to treatment plants for vitrification. Additionally, recalcitrant boehmite degrades glass quality and must be reduced prior to vitrification, but dissolves much more slowly than predicted given surface normalized rates. Existing empirical models based on ex situ experiments and observations lack true predictive capabilities. Recent advances in in situ microscopy, aberration corrected TEM, theoretical modeling across scales, and experimental methods for probing the physics and chemistry at mineral-fluid and mineral-mineral interfaces are being implemented to build robustly predictive physics-based models.

Environmental Molecular Sciences Laboratory↗

A Fresh Look at Coupled-Oscillator Spatial Power Combining

Quasi-optical oscillators were proposed a little more than ten years ago as a means of developing the power levels needed for applications at millimeter frequencies using large numbers of individual semiconductor devices each of which produces only a modest amount of power [J.W. Mink, IEEE Trans. MTT., vol. 34, p. 273, 19861. An operating system was demonstrated soon after [Z.B. Popovic et. al, Int. J. Infrared and Millimeter Waves, v. 9, p. 647, 1988] in the form of a so-called grid oscillator. This device constituted a rectangular array of oscillating devices that are mutually coupled so that they oscillator coherently. The interconnecting lines in one direction serve as radiators so that the oscillators radiate directly, and the radiated fields add. Subsequently, coupled oscillators using resonant transmission line lengths was demonstrated by Mortazawi and Itoh [IEEE Trans. MTT., vol. 38, p. 86,1990). In recent work, coupled-oscillator power combiners have received less attention, with amplifier/combiners receiving more attention. Specific weaknesses of spatial-combining oscillators have motivated this transition. Namely, the oscillators employ low-Q resonators (resulting in low signal quality) and no clear means of modulation has been identified until recently. In this presentation, we review coupled-oscillator combiners in broad terms, indicating the features that make particular systems viable. We indicate how these features can be reconciled to functional requirements for system applications. Comparisons are drawn between two approaches to obtain mutual coupling: One employs low-Q oscillator circuits at each site, with concomitantly high propensity for the oscillators to couple. The other approach employs moderate-Q oscillators at each site with the concomitant requirement to tune the oscillators so that they share a range of frequencies over which they can couple and lock. In either case, precise frequency control and modulation can be achieved through locking to an external frequency source that ensures high quality signals. A recent development in coupled-oscillator arrays provides a means for beam-steering the radiation field of coupled oscillators through de-tuning of the edge elements in the array. This detuning introduces a progressive phase shift across the oscillator array. This 0 suggests architectures that can replace the functionality of a phased array without the cost 0 incurred by phase shifters. A comprehensive theory of the phase interactions among devices in such arrays is under development [e.g., Pogorzelski, York, and Maccarini, 1998 AP-S International Symposium, Atlanta, GA. June, 19981.

Pearson, L.W.↗

THE SPECTRUM OF ISOTROPIC DIFFUSE GAMMA-RAY EMISSION BETWEEN 100 MeV AND 820 GeV

The γ-ray sky can be decomposed into individually detected sources, diffuse emission attributed to the interactions of Galactic cosmic rays with gas and radiation fields, and a residual all-sky emission component commonly called the isotropic diffuse γ-ray background (IGRB). The IGRB comprises all extragalactic emissions too faint or too diffuse to be resolved in a given survey, as well as any residual Galactic foregrounds that are approximately isotropic. The first IGRB measurement with the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope (Fermi) used 10 months of sky-survey data and considered an energy range between 200 MeV and 100 GeV. Improvements in event selection and characterization of cosmic-ray backgrounds, better understanding of the diffuse Galactic emission (DGE), and a longer data accumulation of 50 months allow for a refinement and extension of the IGRB measurement with the LAT, now covering the energy range from 100 MeV to 820 GeV. The IGRB spectrum shows a significant high-energy cutoff feature and can be well described over nearly four decades in energy by a power law with exponential cutoff having a spectral index of 2.32 ± 0.02 and a break energy of (279 ± 52) GeV using our baseline DGE model. The total intensity attributed to the IGRB is (7.2 ± 0.6) × 10{sup –6} cm{sup –2} s{sup –1} sr{sup –1} above 100 MeV, with an additional +15%/–30% systematic uncertainty due to the Galactic diffuse foregrounds.

79 ASTRONOMY AND ASTROPHYSICS↗

THE X-FACTOR IN GALAXIES. I. DEPENDENCE ON ENVIRONMENT AND SCALE

Characterizing the conversion factor between CO emission and column density of molecular hydrogen, X{sub CO}, is crucial in studying the gaseous content of galaxies, its evolution, and relation to star formation. In most cases the conversion factor is assumed to be close to that of giant molecular clouds (GMCs) in the Milky Way, except possibly for mergers and star-bursting galaxies. However, there are physical grounds to expect that it should also depend on the gas metallicity, surface density, and strength of the interstellar radiation field. The X{sub CO} factor may also depend on the scale on which CO emission is averaged due to effects of limited resolution. We study the dependence of X{sub CO} on gas properties and averaging scale using a model that is based on a combination of results of sub-parsec scale magnetohydrodynamic simulations and on the gas distribution from self-consistent cosmological simulations of galaxy formation. Our model predicts X{sub CO} Almost-Equal-To (2-4) Multiplication-Sign 10{sup 20} K{sup -1} cm{sup -2} km{sup -1} s, consistent with the Galactic value, for interstellar medium conditions typical for the Milky Way. For such conditions the predicted X{sub CO} varies by only a factor of two for gas surface densities in the range {Sigma}{sub H{sub 2}}{approx}50-500 M{sub sun}pc{sup -2}. However, the model also predicts that more generally on the scale of GMCs, X{sub CO} is a strong function of metallicity and depends on the column density and the interstellar UV flux. We show explicitly that neglecting these dependencies in observational estimates can strongly bias the inferred distribution of H{sub 2} column densities of molecular clouds to have a narrower and offset range compared to the true distribution. We find that when averaged on {approx}kiloparsec scales the X-factor depends only weakly on radiation field and column density, but is still a strong function of metallicity. The predicted metallicity dependence can be approximated as X{sub CO}{proportional_to}Z{sup -{gamma}} with {gamma} Almost-Equal-To 0.5-0.8.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-488: Comparison of the TG-51 and TG-51 Addendum Calibration Protocols

Purpose: To quantify differences between the TG51 and TG51 addendum calibration protocols. Methods: Beam energies of 6X, 6XSRS, 10X, 15X, 23X, 6XFFF, and 10XFFF were calibrated following both the TG51 and TG51 addendum protocols using both a Farmer and a scanning ionization chamber with traceable absorbed dose-to-water calibrations. For the TG51 addendum procedure, the collimating jaws were positioned to define a 10×10cm{sup 2} radiation field, a lead foil was only used for kQ measurements of FFF energies, and a volume-averaging correction was applied based on crossline and inline dose profiles. For the TG51 procedure, the collimating jaws were set to 10×10cm{sup 2} according to the digital readout, and a lead foil was used for kQ measurements of energies greater than 10MV. Results: For beam energies with a flattening filter, absorbed dose-to-water determined by the two protocols differed by 0.1%–0.3%. For FFF beam energies, differences between the protocols were up to 0.2% and 0.8% for the scanning and Farmer ionization chambers, respectively. Differences between the protocols were due to kQ determination, volume-averaging correction, and measurement of raw ionization. Differences in kQ values between the two protocols were up to 0.4% and 0.2% for the scanning and Farmer ionization chambers, respectively. Volume-averaging corrections were less than 0.1% for the scanning ionization chamber, and up to 0.4% and 0.6% for the Farmer ionization chamber in beams with a flattening filter and FFF beams, respectively. Raw ionization measurements differed up to 0.3%±0.07% due to differences in jaw settings. Conclusion: The TG51 and TG51 addendum calibration protocols differed less than 0.3% for the scanning ionization chamber. For the Farmer chamber in FFF energies, volume-averaging corrections of up to 0.6% contributed to calibration differences of up to 0.8%. Failure to verify the radiation field size can produce calibration differences of up to 0.3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MID-INFRARED SPECTROSCOPY OF TWO LENSED STAR-FORMING GALAXIES

We present low-resolution, rest-frame {approx}5-12 {mu}m Spitzer/IRS spectra of two lensed z {approx} 2 UV-bright star-forming galaxies, SDSS J120602.09+514229.5 and SDSS J090122.37+181432.3. Using the magnification boost from lensing, we are able to study the physical properties of these objects in greater detail than is possible for unlensed systems. In both targets, we detect strong polycyclic aromatic hydrocarbon (PAH) emission at 6.2, 7.7, and 11.3 {mu}m, indicating the presence of vigorous star formation. For J1206, we find a steeply rising continuum and significant [S IV] emission, suggesting that a moderately hard radiation field is powering continuum emission from small dust grains. The strength of the [S IV] emission also implies a sub-solar metallicity of {approx}0.5 Z{sub sun}, confirming published rest-frame optical measurements. In J0901, the PAH lines have large rest-frame equivalent widths (>1 {mu}m) and the continuum rises slowly with wavelength, suggesting that any active galactic nucleus (AGN) contribution to L{sub IR} is insignificant, in contrast to the implications of optical emission-line diagnostics. Using [O III] line flux as a proxy for AGN strength, we estimate that the AGN in J0901 provides only a small fraction of its mid-infrared continuum flux. By combining the detection of [Ar II] with an upper limit on [Ar III] emission, we infer a metallicity of {approx}>1.3 Z{sub sun}. This work highlights the importance of combining rest-frame optical and mid-IR spectroscopy in order to understand the detailed properties of star-forming galaxies at high redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Upgrades of Diagnostic Techniques and Technologies for JET next D-T Campaigns

JET next D-T campaign is presently scheduled for the year 2017. The main scientific objectives include the assessment of the isotopic effects on various plasma aspects: mainly on confinement, on the threshold to access the H mode and on ELM behaviour. From a technical point of view, the total yield of the entire D-T phase is expected to be 1.7 1021 neutrons, about a factor of six higher than the previous main D-T campaign on JET, DTE1. Therefore the radiation field will be quite relevant for next step devices, since the neutron flux at the first wall (∼10{sup 16} n/cm{sup 2}s), for example, will be comparable to the one in ITER behind the blanket. From a point of view of diagnostics developments, for many years JET diagnostics have been upgraded in order to provide adequate support for the scientific exploitation of a D-T campaign. The main efforts have concentrated on improving three main aspects of JET measuring capability: 1) the quality of the measurements of the electron and ion fluids to support the plasma physics programme 2) the diagnostic for the fusion products 3) diagnostic technologies for ITER. In terms of general diagnostic capability, compared to the previous DTE1, JET diagnostics have a much better spatial and temporal resolution of both the ion and electron fluid (about one order of magnitude improvement for each parameter). The consistency of the various independent measurements of the same parameters has also increased significantly; the three independent measurements of the electron temperature, for example, agree now within 5%. Moreover, solutions are being addressed to operate some cameras, both visible and IR, even during the full D-T phase to provide imaging of the plasma and the first wall. Various upgrades of neutral particle analysis are being considered, mainly to measure the isotopic composition. A new set of reflectometers is expected to provide valuable information about the changes in the turbulence with the different fuel mixtures. With regard to the fusion products, JET now can deploy a consistent set of techniques to measure the neutron yield and neutron spectra and to diagnose the fast particles. A full calibration of the neutron diagnostics with a 14 MeV source is being considered, after the recent very successful calibration for the 2.45 MeV neutrons. Vertical and horizontal lines of sight are foreseen for neutron and gamma spectrometry, in order to better determine the thermal neutron yield and to separate the trapped and passing components of the alphas. Various gamma ray spectrometers are being developed to cover all the various operational scenarios, from trace tritium to 50-50 D-T operation. The redistribution of the alphas will be measured with the gamma ray cameras, recently upgraded with full digital electronics; new detectors are being considered to bring the time resolution of the system in the ten of ms range. The lost alphas will also be diagnosed with improved spatial and temporal resolution, using Faraday cups and a scintillator probe. From a technological perspective, the D-T campaign will provide a unique opportunity to test ITER relevant technologies. From radiation hard detectors, for example Hall probes, to neutron absorbers and to shielding concepts, the potential of various solutions in a realistic 14 MeV radiation field will be assessed. The effects of neutrons and gamma on ancillary technologies and systems, such as fibre optics and electronics circuits, are also expected to be sufficiently high to derive useful information about the competitive advantage of various alternatives.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiolytic evaluation of select sulfur chlorides (S 2 Cl 2 and SOCl 2 ) for advanced low temperature chlorination of zirconium-based used nuclear fuel cladding

New sulfur chloride compounds—sulfur monochloride (S 2 Cl 2 ) and thionyl chloride (SOCl 2 )—have been proposed as alternative chlorinating agents for the chemical decladding of zirconium-based used nuclear fuel cladding materials. However, the radiation stability of these compounds has not been thoroughly evaluated, despite envisioned process conditions involving intense, multi-component radiation fields. Knowledge of the radiation chemistry of these sulfur chlorides is essential for the development and optimization of alternative chlorination technologies. To this end, we present preliminary findings on the gamma radiolysis of neat S 2 Cl 2 and SOCl 2 at ambient temperature up to ~ 34 MGy. In this study, Raman spectroscopy and density functional theory calculations were used to identify the Raman-active degradation products from S 2 Cl 2 and SOCl 2 radiolysis. Both sulfur chloride compounds exhibited significant radiation resistance, with respect to changes in the Raman signatures of the parent compounds and the ingrowth of Raman-active degradation products. For S 2 Cl 2 , molecular chlorine (Cl 2 ) was directly identified as the predominant degradation product, which was completely consumed at higher absorbed doses (> 9 MGy). Similarly, the main degradation product from SOCl 2 radiolysis was also Cl 2 , although in this system it continued to grow in with dose over the entire dose range. Further, an “S=O” containing degradation product(s) was also identified as a compliment to Cl 2 . Overall, the perceived radiation resistance of these sulfur chloride compounds makes them suitable for inclusion in a used nuclear fuel chemical decladding process, especially as radiolytically formed Cl 2 can be used to reform the parent compounds, thereby increasing the longevity of the solvents used.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

CHEMISTRY OF A PROTOPLANETARY DISK WITH GRAIN SETTLING AND Ly{alpha} RADIATION

We present results from a model of the chemical evolution of protoplanetary disks. In our models, we directly calculate the changing propagation and penetration of a high energy radiation field with Ly{alpha} radiation included. We also explore the effect on our models of including dust grain settling. We find that, in agreement with earlier studies, the evolution of dust grains plays a large role in determining how deep the UV radiation penetrates into the disk. Significant grain settling at the midplane leads to much smaller freeze-out regions and a correspondingly larger molecular layer, which leads to an increase in column density for molecular species such as CO, CN, and SO. The inclusion of Ly{alpha} radiation impacts the disk chemistry through specific species that have large photodissociation cross sections at 1216 A. These include HCN, NH{sub 3}, and CH{sub 4}, for which the column densities are decreased by an order of magnitude or more due to the presence of Ly{alpha} radiation in the UV spectrum. A few species, such as CO{sub 2} and SO, are enhanced by the presence of Ly{alpha} radiation, but rarely by more than a factor of a few.

54 ENVIRONMENTAL SCIENCES↗

CONSTRAINTS ON HYPERLUMINOUS QSO LIFETIMES VIA FLUORESCENT Ly{alpha} EMITTERS AT Z {approx_equal} 2.7

We present observations of a population of Ly{alpha} emitters (LAEs) exhibiting fluorescent emission via the reprocessing of ionizing radiation from nearby hyperluminous QSOs. These LAEs are part of a survey at redshifts 2.5 < z < 2.9 combining narrow-band photometric selection and spectroscopic follow-up to characterize the emission mechanisms, physical properties, and three-dimensional locations of the emitters with respect to their nearby hyperluminous QSOs. These data allow us to probe the radiation field, and thus the radiative history, of the QSOs, and we determine that most of the eight QSOs in our sample have been active and of comparable luminosity for a time 1 Myr {approx}< t{sub Q} {approx}< 20 Myr. Furthermore, we find that the ionizing QSO emission must have an opening angle {theta} {approx} 30 Degree-Sign or larger relative to the line of sight.

79 ASTRONOMY AND ASTROPHYSICS↗

ULTRA SECURE HIGH RELIABILITY WIRELESS RADIATION MONITOR

Radiation monitoring in nuclear facilities is essential to safe operation of the equipment as well as protecting personnel. In specific, typical air monitoring of radioactive gases or particulate involves complex systems of valves, pumps, piping and electronics. The challenge is to measure a representative sample in areas that are radioactively contaminated. Running cables and piping to these locations is very expensive due to the containment requirements. Penetration into and out of an airborne or containment area is complex and costly. The process rooms are built with thick rebar-enforced concrete walls with glove box containment chambers inside. Figure 1 shows high temperature radiation resistance cabling entering the top of a typical glove box. In some case, the entire processing area must be contained in a 'hot cell' where the only access into the chamber is via manipulators. An example is shown in Figure 2. A short range wireless network provides an ideal communication link for transmitting the data from the radiation sensor to a 'clean area', or area absent of any radiation fields or radioactive contamination. Radiation monitoring systems that protect personnel and equipment must meet stringent codes and standards due to the consequences of failure. At first glance a wired system would seem more desirable. Concerns with wireless communication include latency, jamming, spoofing, man in the middle attacks, and hacking. The Department of Energy's Savannah River National Laboratory (SRNL) has developed a prototype wireless radiation air monitoring system that address many of the concerns with wireless and allows quick deployment in radiation and contamination areas. It is stand alone and only requires a standard 120 VAC, 60 Hz power source. It is designed to be mounted or portable. The wireless link uses a National Security Agency (NSA) Suite B compliant wireless network from Fortress Technologies that is considered robust enough to be used for classified data transmission in place of NSA Type 1 devices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Robust optimization methods for cardiac sparing in tangential breast IMRT

Purpose: In left-sided tangential breast intensity modulated radiation therapy (IMRT), the heart may enter the radiation field and receive excessive radiation while the patient is breathing. The patient’s breathing pattern is often irregular and unpredictable. We verify the clinical applicability of a heart-sparing robust optimization approach for breast IMRT. We compare robust optimized plans with clinical plans at free-breathing and clinical plans at deep inspiration breath-hold (DIBH) using active breathing control (ABC). Methods: Eight patients were included in the study with each patient simulated using 4D-CT. The 4D-CT image acquisition generated ten breathing phase datasets. An average scan was constructed using all the phase datasets. Two of the eight patients were also imaged at breath-hold using ABC. The 4D-CT datasets were used to calculate the accumulated dose for robust optimized and clinical plans based on deformable registration. We generated a set of simulated breathing probability mass functions, which represent the fraction of time patients spend in different breathing phases. The robust optimization method was applied to each patient using a set of dose-influence matrices extracted from the 4D-CT data and a model of the breathing motion uncertainty. The goal of the optimization models was to minimize the dose to the heart while ensuring dose constraints on the target were achieved under breathing motion uncertainty. Results: Robust optimized plans were improved or equivalent to the clinical plans in terms of heart sparing for all patients studied. The robust method reduced the accumulated heart dose (D10cc) by up to 801 cGy compared to the clinical method while also improving the coverage of the accumulated whole breast target volume. On average, the robust method reduced the heart dose (D10cc) by 364 cGy and improved the optBreast dose (D99%) by 477 cGy. In addition, the robust method had smaller deviations from the planned dose to the accumulated dose. The deviation of the accumulated dose from the planned dose for the optBreast (D99%) was 12 cGy for robust versus 445 cGy for clinical. The deviation for the heart (D10cc) was 41 cGy for robust and 320 cGy for clinical. Conclusions: The robust optimization approach can reduce heart dose compared to the clinical method at free-breathing and can potentially reduce the need for breath-hold techniques.

60 APPLIED LIFE SCIENCES↗

Nonlinear Weibel Instability and Turbulence in Strong Collisionless Shocks

This research project was devoted to studies of collisionless shocks, their properties, microphysics and plasma physics of underlying phenomena, such as Weibel instability and generation of small-scale fields at shocks, particle acceleration and transport in the generated random fields, radiation mechanisms from these fields in application to astrophysical phenomena and laboratory experiments (e.g., laser-plasma and beam-plasma interactions, the fast ignition and inertial confinement, etc.). Thus, this study is highly relevant to astrophysical sciences, the inertial confinement program and, in particular, the Fast Ignition concept, etc. It makes valuable contributions to the shock physics, nonlinear plasma theory, as well as to the basic plasma science, in general.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spacecraft Radiation Analysis

The radiation interface in spacecrafts using radioisotope thermoelectric generators is studied. A Monte Carlo analysis of the radiation field that includes scattered radiation effects, produced neutron and gamma photon isoflux contours as functions of distance from the RTG center line. It is shown that the photon flux is significantly depressed in the RTG axial direction because of selfshielding. Total flux values are determined by converting the uncollided flux values into an equivalent RTG surface source and then performing a Monte Carlo analysis for each specific dose point. Energy distributions of the particle spectra completely define the radiation interface for a spacecraft model.

Harris, D. W.↗

Vibrational excitation of H2 in intense ultraviolet fluxes

The vibrational excitation of H2 in intense ultraviolet radiation fields is studied. The radiative cascade through bound levels of the ground electronic state, following absorption of Lyman- and Werner-band photons, is modified to include effects of 'multiple pumping' and direct photodissociation from the high vibrational levels. Although the column densities in the excited vibrational levels produced by UV pumping appear too low to explain the recently observed Orion quadrupole emission lines, it is suggested that the far-red lines in the (3-0) and (4-0) bands, produced by UV pumping from O stars near dense molecular clouds, may be detectable.

Shull, J. M.↗