Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Control of an average output power of a CuBr laser

We have studied the pump parameters of a CuBr laser (pulse repetition rate of 14 kHz) with an independent heating of the active medium and an additional excitation source, providing an operational control of the radiation parameters in a given time interval. We have fabricated an experimental setup that makes it possible to change the average output power by applying a control pulse which is ahead of the main pulse by 0.12 - 20 {mu}s. It is shown that to ensure the effective control of the laser power, the voltage amplitude of the additional excitation pulse should be within 12 % - 28 % of the main pulse amplitude. In this case, the proposed control regime allows a 2.5-fold decrease in the time delay between the control and main excitation pulses due to a higher energy of the additional pulse compared to self-heating regime of the laser operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Possibility of protecting a mirror of a laser on the 4d - 4p transitions of nickel-like tantalum ions against spontaneous X-rays by means of a filter

The possibility of protecting a mirror of a laser on the 4d - 4p transitions of nickel-like tantalum ions against spontaneous X-rays by means of a carbon or potassium filter is considered. It is shown that such filters can transmit 75% - 80% of laser radiation at 44.83 A, attenuating at least by half the intensity of radiation incident on the mirror in other spectral regions, which considerably suppresses the double-pass amplification. (control of laser radiation parameters)

74 ATOMIC AND MOLECULAR PHYSICS↗

A radiation-hardened star scanner for spacecraft guidance and control

A star scanner for the Galileo Project is described. Because it must function in the intense Jupiter radiation field, which consists primarily of high-energy electrons and protons, this star scanner is designed with radiation-hardness as a prime objective. The optics and the multiplier phototube are specially designed to minimize fluorescence and Cerenkov effects, and the electronic components to minimize ionization and displacement damage. The star-scanner layout provides maximum shielding for the optics and phototube. Test results predict successful operation in the expected Jovian radiation environment.

Birnbaum, M. M.↗

Biochemical Control and Toxicity Outcomes of Stereotactic Body Radiation Therapy Versus Low-Dose-Rate Brachytherapy in the Treatment of Low- and Intermediate-Risk Prostate Cancer

Low-dose-rate (LDR) brachytherapy and stereotactic body radiation therapy (SBRT) have both shown acceptable outcomes in the treatment of low- and intermediate-risk prostate cancer. Minimal data have been published directly comparing rates of biochemical control and toxicity with these 2 modalities. We hypothesize that LDR and SBRT will provide similar rates of biochemical control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase-Controlled Magnetic Mirror for Wavefront Correction

Typically, light interacts with matter via the electric field and interaction with weakly bound electrons. In a magnetic mirror, a patterned nanowire is fabricated over a metallic layer with a dielectric layer in between. Oscillation of the electrons in the nanowires in response to the magnetic field of incident photons causes a re-emission of photons and operation as a "magnetic mirror." By controlling the index of refraction in the dielectric layer using a local applied voltage, the phase of the emitted radiation can be controlled. This allows electrical modification of the reflected wavefront, resulting in a deformable mirror that can be used for wavefront control. Certain applications require wavefront quality in the few-nanometer regime, which is a major challenge for optical fabrication and alignment of mirrors or lenses. The use of a deformable magnetic mirror allows for a device with no moving parts that can modify the phase of incident light over many spatial scales, potentially with higher resolution than current approaches. Current deformable mirrors modify the incident wavefront by using nano-actuation of a substrate to physically bend the mirror to a desired shape. The purpose of the innovation is to modify the incident wavefront for the purpose of correction of fabrication and alignment-induced wavefront errors at the system level. The advanced degree of precision required for some applications such as gravity wave detection (LISA - Laser Interferometer Space Antenna) or planet finding (FKSI - Fourier-Kelvin Stellar Interferometer) requires wavefront control at the limits of the current state of the art. All the steps required to fabricate a magnetic mirror have been demonstrated. The modification is to apply a bias voltage to the dielectric layer so as to change the index of refraction and modify the phase of the reflected radiation. Light is reflected off the device and collected by a phase-sensing interferometer. The interferometer determines the initial wavefront of the device and fore optics. A wavefront correction is calculated, and voltage profile for each nanowire strip is determined. The voltage is applied, modifying the local index of refraction of the dielectric under the nanowire strip. This modifies the phase of the reflected light to allow wavefront correction.

Hagopian, John↗

Influence of saturable absorber saturation power, modulation depth and relaxation time on pulse parameters of a soliton fibre laser

The influence of the saturable absorber saturation power, modulation depth and relaxation time on the energy and shape of fibre soliton laser pulses has been studied by numerical simulation. The results suggest that the use of a saturable absorber with a lower saturation power in a fibre laser ensures pulsed lasing onset at a lower gain. The fibre laser pulse energy decreases as the saturation power of the absorber or the relaxation time of its open state increases at a constant gain coefficient. In addition, increasing the absorber saturation modulation depth at a constant gain coefficient has been shown to reduce the pulse peak power and energy. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Summary of studies for a solar optical telescope in space: 1968-1976

The primary objective of this review is to tabulate the basic recommendations of several solar telescope studies. A primary matrix, listing some of the basic optical parameters, was compiled and forms the basis for a table. From this table it is apparent that a strong consensus exists on the configuration of the telescope and on its fundamental dimensionless parameters. Other tables presented in this document address the basic approach of each study to the telescope design as well as to the design of critical subsystems. These subsystem problems include the material, coating, configuration, mounting, launch locks, and thermal control of the primary mirror, the structure of the main telescope and the instrument bay, the mechanisms for radiation rejection, thermal control, and meteoroid shielding, and methods of maintaining image quality by proper alignment and by image motion compensation.

Bremer, J.↗

Ground plane interference elimination by passive element

The radiation pattern of a beam at elevation angles near the horizon is improved for phased array antennas by control of the radiation field intensity near the horizon to reduce multipath disturbances, and to improve the axial ratio of a circularly polarized phased array antenna. This is accomplished by placing a parasitic phase shifting element directly below the antenna beam axis. The waveguide section is designed to produce a phase shift in the portion of antenna radiation energy passing through it to cancel some of the radiation energy in the direction of the horizon. The spacing of the waveguide section in front of the antenna is determined empirically for optimum results, i.e., for reduction of beam power below about 20 deg. without affecting beam power at high elevation angles.

Bonebright, Mark E.↗

Ground plane interference elimination by passive element

The radiation pattern of a beam at elevation angles near the horizon is improved for phased array antennas by control of the radiation field intensity near the horizon to reduce multipath disturbances, and to improve the axial ratio of a circularly polarized phased array antenna. This is accomplished by placing a parasitic phase shifting element directly below the antenna beam axis. The waveguide section is designed to produce a phase shift in the portion of antenna radiation energy passing through it to cancel some of the radiation energy in the direction of the horizon. The spacing of the waveguide section in front of the antenna is determined empirically for optimum results, i.e., for reduction of beam power below about 20.degree. without affecting beam power at high elevation angles.

Bonebright, Mark E.↗

Present state of knowledge of the upper atmosphere: An assessment report; processes that control ozone and other climatically important trace gases

The state of knowledge of the upper atmosphere was assessed as of January 1986. The physical, chemical, and radiative processes which control the spatial and temporal distribution of ozone in the atmosphere; the predicted magnitude of ozone perturbations and climate changes for a variety of trace gas scenarios; and the ozone and temperature data used to detect the presence or absence of a long term trend were discussed. This assessment report was written by a small group of NASA scientists, was peer reviewed, and is based primarily on the comprehensive international assessment document entitled Atmospheric Ozone 1985: Assessment of Our Understanding of the Processes Controlling Its Present Distribution and Change, to be published as the World Meteorological Organization Global Ozone Research and Monitoring Project Report No. 16.

Watson, R. T.↗

Coherent beam combining of 2-{mu}m fibre lasers

Coherent beam combining of 2-{mu}m fibre lasers is studied numerically. Such lasers are a suitable candidate for creation of a beam combining module due to their higher nonlinear effect and optical damage threshold compared to their 1-{mu}m counterparts. The calculations results show that radiation of a 1-{mu}m fibre laser has a better focusing property in free-space due to a smaller wavelength, whereas a 2-{mu}m laser beam has a better focusing capability in the target-plane under conditions of real atmospheric turbulence. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sci-Fri AM: Quality, Safety, and Professional Issues 02: Recent work on TQC Suite and Data from a National survey on Community Uptake

The Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) have worked together in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment and technologies, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. Early community engagement and uptake survey data showed 70% of Canadian centers are part of this process and that the data in the guideline documents reflect, and are influencing the way Canadian radiation treatment centres run their technical quality control programs. As the TQC development framework matured as a cross-country initiative, guidance documents have been developed in many clinical technologies. Recently, there have been new TQC documents initiated for Gamma Knife and Cyberknife technologies where the entire communities within Canada are involved in the review process. At the same time, QARSAC reviewed the suite as a whole for the first time and it was found that some tests and tolerances overlapped across multiple documents as single tests could pertain to multiple quality control areas. The work to streamline the entire suite has allowed for improved usability of the suite while keeping the integrity of single quality control areas. The suite will be published by the JACMP, in the coming year.

60 APPLIED LIFE SCIENCES↗

Frequency control of tunable lasers using a frequency-calibrated λ-meter in an experiment on preparation of Rydberg atoms in a magneto-optical trap

A new technique is proposed and applied to study the frequency drift of an external-cavity semiconductor laser, locked to the transmission resonances of a thermally stabilised Fabry–Perot interferometer. The interferometer frequency drift is measured to be less than 2 MHz h{sup -1}. The laser frequency is measured using an Angstrom wavemeter, calibrated using an additional stabilised laser. It is shown that this system of laser frequency control can be used to identify Rydberg transitions in ultracold {sup 7}Li atoms. (control of laser radiation parameters)

74 ATOMIC AND MOLECULAR PHYSICS↗

On the control of electron heating for optimal laser radiation pressure ion acceleration

We study the onset of electron heating in intense laser–solid interactions and its impact on the spectral quality of radiation pressure accelerated ions in both hole boring and light sail regimes. Two- and three-dimensional particle-in-cell (PIC) simulations are performed over a wide range of laser and target parameters and reveal how the pulse duration, profile, polarization and target surface stability control the electron heating, the dominant ion acceleration mechanisms and the ion spectra. We find that the onset of strong electron heating is associated with the growth of the Rayleigh–Taylor-like instability at the front surface and must be controlled to produce high-quality ion beams, even when circularly polarized lasers are employed. We define a threshold condition for the maximum duration of the laser pulse that allows mitigation of electron heating and radiation pressure acceleration of narrow energy spread ion beams. The model is validated by three-dimensional PIC simulations, and the few experimental studies that reported low energy spread radiation pressure accelerated ion beams appear to meet the derived criteria. The understanding provided by our work will be important in guiding future experimental developments, for example for the ultrashort laser pulses becoming available at state-of-the-art laser facilities, for which we predict that proton beams with $\sim$ 150–250 MeV, $\sim$ 30% energy spread, and a total laser-to-proton conversion efficiency of $\sim$ 20% can be produced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lighting considerations in controlled environments for nonphotosynthetic plant responses to blue and ultraviolet radiation

This essay will consider both physical and photobiological aspects of controlled environment lighting in the spectral region beginning in the blue and taken to the normal limit of the solar spectrum in the ultraviolet. The primary emphasis is directed to questions of plant response to sunlight. Measurement and computations used in radiation dosimetry in this part of the spectrum are also briefly treated. Because of interest in the ozone depletion problem, there has been some activity in plant UV-B research and there are several recent reviews available. Some aspects of growth chamber lighting as it relates to UV-B research were covered earlier. Apart from work related to the blue/UV-A receptor, less attention has been given to UV-A responses.

Caldwell, M. M.↗

Method and apparatus for precision control of radiometer

A radiometer controller of a radiation detector is provided with a calibration method and apparatus comprised of mounting all temperature sensitive elements of the controller in thermostatically controlled ovens during calibration and measurements, using a selected temperature that is above any which might be reached in the field. The instrument is calibrated in situ by adjusting heater power (EI) to the receptor cavity in the radiometer detector to a predetermined full scale level and is displayed by a meter.

Estey, R. S.↗

Power scaling of Tm-doped fibre lasers using an all-fibre composite Michelson-type cavity

We report a 4-W all-fibre Tm-doped fibre laser using a composite cavity with a centre wavelength of 1952.02 nm. The composite cavity consists of two interferometric laser arms that are efficiently combined. Each interferometric laser arm contains a double-clad Tm-doped silica fibre operating in cw mode and pumped by pigtailed laser diodes with a centre wavelength of 793 nm. A high combining efficiency of 93.9 % and a narrow linewidth of 0.1 nm are obtained. The output power of the laser can be scaled straight forwardly by improving the pump power and optimising the component parameters at 2 μm (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Manipulation of Liquids Using Phased Array Generation of Acoustic Radiation Pressure

A phased array of piezoelectric transducers is used to control and manipulate contained as well as uncontained fluids in space and earth applications. The transducers in the phased array are individually activated while being commonly controlled to produce acoustic radiation pressure and acoustic streaming. The phased array is activated to produce a single pulse, a pulse burst or a continuous pulse to agitate, segregate or manipulate liquids and gases. The phased array generated acoustic radiation pressure is also useful in manipulating a drop, a bubble or other object immersed in a liquid. The transducers can be arranged in any number of layouts including linear single or multi- dimensional, space curved and annular arrays. The individual transducers in the array are activated by a controller, preferably driven by a computer.

Oeftering, Richard C.↗