White Earth Community Facilities Solar PV Project (Final Report)

Funded project was for the design, installation, and performance monitoring of 2 - 11.4 kW AC and 1-38.0 kW AC ground-mount solar installations for three tribal community facilities, for a total 60.8 kW AC, including a daycare facility and two community centers. Of in excess of 120 tribal buildings these facilities had showed the best promise for implementing solar, based upon site characteristics, roof loads, roof orientation and building size. The White Earth Nation seeks to move forward proactively to address the following project goals and objectives: 1) Reduction of energy costs, 2) Increasing energy security for Indian Tribes and tribal members, 3) Adding 60.8 KW in renewable energy generation (solar PV), 4) Offsets, reduces coal-fired electric energy demand by 76,397 kWh, 817,448 Source Energy Btu annually, and S) Meets the overall solar PV target set in the FOA.

14 SOLAR ENERGY↗

An Updated Review of the Solar PV Installation Workforce Literature

In order to develop a well-trained, equitable, and inclusive workforce with high quality jobs, the DOE Solar Energy Technologies Office (SETO) identified a need for analytical context around different PV project characteristics and labor aspects, and how they might impact workforce wellbeing and PV industry growth. To determine the most valuable novel analytical contributions, this work reviews existing literature on solar workforce topics to identify what areas have been studied previously and where gaps remain. Focus areas included the following topics: (1) metrics for solar workforce, deployment, costs, and associated studies capturing aspects such as demographics and regional distribution, (2) solar workforce wellbeing, including employee contracting mechanisms, compensation, occupational safety and health, and community impacts, (3) national and state policies most relevant to the U.S. solar workforce, and (4) ongoing efforts to expand solar workforce participation, including local staffing dynamics, challenges, and relevant strategies.

14 SOLAR ENERGY↗

Modular Wide-bandgap String Inverters for Low-cost Medium-voltage Transformerless PV Systems

The proposed technology combines advances in wide-bandgap power electronics with breakthroughs in distributed and decentralized control to produce ultra-low-cost medium-voltage transformerless PV inverters that are composed of stackable lightweight blocks. Taken together, the proposed circuit designs and accompanying control strategies will yield integrated control+circuit (C2) blocks, each comprising a converter and local controller, that can be assembled in a modular fashion to obtain distributed conversion interfaces for next-generation commercial and utility-scale PV systems. We will utilize SiC devices to obtain C2 blocks that can individually operate at a voltage and power in excess of 1 kV and 100 kW, respectively, such that ensembles of series-connected blocks perform direct dc to three-phase ac conversion at medium voltages (e.g., 12 kV–35 kV) and at multi-MW power levels.

42 ENGINEERING↗

Towards 50 Year Lifetime PV Modules: Double Glass vs. Glass/Backsheet

This award aims to increase the lifetime of c-Si modules by lowering the power degradation rate to the goal of 0.2 %/year, while also increasing the harvested irradiance per module using bifacial cells to achieve the 2030 SunShot goal of $0.03/kWh. Increasing the durability and lifetime of modules requires improved module packaging material choices and module architectures to exploit new cell improvements. Bifacial PERC cells (with backside aluminum fingers) are becoming a primary PV technology due to their decreased rear surface recombination and increased light absorption compared to traditional monofacial Al-BSF cells. Bifacial modules with double glass architectures have been deployed to capture the rear-side irradiance thereby increasing the light captured. The choice of a double glass (DG) or glass/backsheet (GB) module leads to two very different chemical (e.g., O 2 , H 2 O) and mechanical environments (e.g., mechanical stress levels) inside the PV module that impact the cell’s operational conditions. The recipient will fabricate 4-cell DG and GB minimodules with various module architectures or constructions (mono- & bifacial cells, transparent & white encapsulants), and conduct stepwise accelerated exposures and characterization.

14 SOLAR ENERGY↗

Fortalecimiento de la Electrificación Rural en Honduras: Una Evaluación Integrada de PV+BESS y Usos Productivos de la Electricidad en Gracias a Dios, Honduras [Empowering Rural Electrification in Honduras: An Integrated Assessment of PV/BESS and Productive Uses of Electricity in Gracias a Dios] (Spanish Translation)

Honduras faces significant challenges in its energy sector, particularly in rural areas where access to reliable and affordable electricity remains limited. The flagship rural electrification initiative for Honduras Secretary of Energy (SEN) is the Politica de Acceso Universal a la Electricidad (PAUEH - Universal Electricity Access Policy), a key solution for addressing this energy poverty is the deployment of more than 1700 distributed solar and hybrid mini-grid solutions. In late 2023 as a first step towards supporting SEN's electrification efforts, the National Renewable Energy Laboratory (NREL) developed a literature review of SEN electrification policy documents and conducted a series of technical capacity-building workshops with SEN and other energy sector stakeholders in Honduras focused on using NREL's open-source REopt tool to conduct techno-economic assessments and develop least-cost optimizations for potential solar + storage mini-grid systems. Building on some initial capacity building on mini-grid modeling, the National Renewable Energy Laboratory (NREL) worked with SEN to develop a detailed techno-economic assessment for electrifying two schools, a healthcare clinic, and a hospital in a hypothetical community within the department of Gracias a Dios. The analysis also evaluates the business case for cold storage productive use of energy (PUE) applications for the fisheries value chain and how the incorporation of these PUE loads potentially impacts both the viability of the PV+BESS solutions as well as local economic development. By assessing the potential for deployment of integrated PV/BESS systems to both support critical community services like education and healthcare, as well as potential for downstream enterprise and economic development, this analysis represents a first step that can help to inform specific strategies for development of pilot PV+BESS projects aligned with national priorities and sector level planning under PAUEH. This is the Spanish translation of NREL/TP-7A40-90865.

14 SOLAR ENERGY↗

Carbon Footprint Analysis of Floating PV Systems

This report, conducted by the Dutch research organization TNO, presents the first detailed life cycle inventory (LCI) analysis of operational floating photovoltaic (FPV) systems. The study, focusing on two operational systems in Western Europe, reveals that FPV systems on small inland water bodies can be a valuable complement to ground-mounted PV systems in terms of greenhouse gas emissions reduction. If PV module degradation is limited, these systems' carbon footprint is 3-4 times lower than the EU grid mix target for 2030. The report compares two FPV systems with different floater compositions (HDPE and steel/HDPE) to hypothetical ground-mounted systems, using comprehensive background data. The findings highlight the necessity for long-term monitoring and thorough environmental assessments. Josco Kester, a scientist at TNO, underscores the potential environmental benefits of these systems, which could enhance the adoption of renewable energy technologies.

14 SOLAR ENERGY↗

Data for Validating Models for PV Module Performance

This data encompasses performance data measured for flat-plate photovoltaic (PV) modules installed in Cocoa, Florida; Eugene, Oregon; and Golden, Colorado. The data include PV module current-voltage curves and associated meteorological data for approximately one-year periods. The data was acquired with the NREL Performance and Energy Rating Testbed (PERT) and the mobile Performance and Energy Rating Testbed (mPERT).

PV, Validation, IV Curves, Field performance, mPER↗

PV Rooftop Database

The National Renewable Energy Laboratory's (NREL) Photovoltaic (PV) Rooftop Database (PVRDB) is a lidar-derived, geospatially-resolved dataset of suitable roof surfaces and their PV technical potential for 128 metropolitan regions in the United States. The PVRDB data are organized by city and year of lidar collection. Five geospatial layers are available for each city and year: 1) the raster extent of the lidar collection, 2) buildings identified from the lidar data, 3) suitable developable planes for each building, 4) aspect values of the developable planes, and 5) the technical potential estimates of the developable planes.

Array↗

U.S. Wind and Solar PV Supply Curves with Future Land-use Change

This dataset provides future supply curves representing the total resource potential for land-based wind and solar photovoltaic (PV) deployment in the conterminous United States after accounting for the impact of land-use and land-cover change (LULC). We use LULC projections from 2010 to 2050 developed based on the Intergovernmental Panel on Climate Change (IPCC) Special Report on Emission Scenarios. The LULC projections are subsequently fed into the renewable energy potential model (reV), which estimates total available wind and solar capacity after excluding non-developable land. Supply curves are provided for four IPCC scenarios in 2050: A1B, A2, B1, and B2. As a baseline, we also provide the supply curve from the B2 scenario in 2010. In addition to the supply curves, we also provide representative wind and solar generation profiles for each supply curve point. These generation profiles are provided as capacity factors and are based on a 2012 weather year using NSRDB and WindToolkit resource data. For more details on the supply curve and profile datasets included here please refer to README. Additional information on the supply curves and the LULC projections used to generate them, as well as an analysis of their impact on wind and solar deployment under decarbonization can be found in the publication linked below: "U.S. Wind and Solar PV Supply Curves with Future Land-use Change Publication".

Array↗

High-Resolution Floating Solar PV Data

This dataset contains over two years of 1-minute resolution data collected from four floating solar sites, as well as data from a land-based PV system co-located with one of the floating sites. The dataset includes highly granular module temperature measurements - five modules per floating site, with three sensors per module, totaling 15 module temperature sensors per floating site. In addition to the module temperature data, meteorological data collected at the floating sites is also included, along with traditional PV system-level parameters. The data is intended for analysis of solar energy production, efficiency, and performance degradation over time. For information about the data file usage see the "README" resource below. See "Metadata File" for information about individual files and other metadata information.

Array↗

Thermally Conductive Backsheets (TCB) of PV Modules: Positive Impacts on Performance, Lifetime and LCOE

The operating temperatures of photovoltaic (PV) modules can be impacted by the selection of specific packaging materials, e.g., backsheets and encapsulants. This research focuses on the evaluation of operating temperature reduction of one-cell modules by comparing conventional Tedlar/polyester/Tedlar (TPT) backsheet with novel thermally conductive backsheets (TCBs) materials. A large number of one-cell modules with two TCB types (TCB_A and TCB_B) and baseline TPT type were fabricated and installed in three different climatic conditions of the hot-dry desert in Arizona (high and low wind speed locations) and North Carolina (temperate with low wind speed location). In this study, these two TCBs were compared with conventional TPT backsheet in terms of performance, lifetime and levelized cost of energy (LCOE). The field results were analyzed for thermal performance of TCBs compared to TPT at three sites for two and half years. This study concludes that the thermal and electrical performances of the PV modules can be improved by using TCB_A in hot and dry climate sites and TCB_B at temperate climate sites. Therefore, the lifetime of TCB-based modules is expected to be higher than TPT-based modules. Using backsheet-specific power degradation levels and assuming the same cost for both types of backsheets, the LCOE of modules using TCBs is estimated to be lower than that of TPT.

14 SOLAR ENERGY↗

Improving the Power Outage Resilience of Buildings with Solar PV through the Use of Battery Systems and EV Energy Storage

Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.

14 SOLAR ENERGY↗

Analysis of PV Fleet Performance in Western United States During August 2020 Extreme Heat Wave

Starting in June 2020 through the end of that year, the western and central United States experienced a widespread heat wave and drought, which resulted in US$5.44 billion (CPI-adjusted) worth of damages. The ongoing heat and drought produced record large wildfires across the region, responsible for an additional US$19.9 billion in damage. These natural disasters directly impacted the energy system in the western US, leading to power blackouts in August 2020. In this work, we analyze the NLR PV Fleets data set, focusing on the geographic area covered by the Western Coordinating Council (WECC). We find that over the 10-day period from August 14 through 24, the median PV system produced 12% lower energy than expected, with some locations experiencing total losses of around 30%. Analyzing the spatial-temporal structure of the data and supplementing with limited operational current and voltage data where available, we find that system underperformance was more strongly impacted by irradiance reduction from wildfire smoke rather than by the high heat itself.

14 SOLAR ENERGY↗

A New Chapter in Solar: Bifacial PV from Emerging Topic to Core Curriculum

Associated with the new edition of the bifacial PV book, this talk reviews the transition of bifacial PV from niche innovation to standard practice, including progress in modeling and performance evaluation, and ongoing challenges in reliability, new applications, and fleet repowering.

14 SOLAR ENERGY↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint

Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on datacollected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

14 SOLAR ENERGY↗

PV System Energy Evaluation Method (Presentation)

This presentation describes a comparison of the "predicted" energy (based on historical weather data) with the "expected" energy (based on the measured weather data) to determine whether a PV system is performing as modeled in order to verify the accuracy of a model. A key factor in defining this energy test is determining the test boundary so that weather variations are not inadvertently included in what is considered to be PV system performance.