Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Techno Economic Analysis of an LGFCS MWE Class SOFCT System (Final Scientific/Technical Report)

The objective of this project is to perform a range of technical, cost and economic analyses of a MWscale natural gas fired Solid Oxide Fuel Cell (SOFC) distributed power generation system design. The information generated will provide evidence of the tracking of technology and manufacturing readiness supportive of Technology Readiness Level 7 (TRL7) system testing in the 2022 timeframe that meets the Department of Energy’s (DOE) targets for cost (<$6000/kW) and durability (<0.5% power degradation/1000 hours).

20 FOSSIL-FUELED POWER PLANTS↗

Space Station Freedom power management and distribution design status

The design status of the power management and distribution electric power system for the Space Station Freedom is presented. The current design is a star architecture, which has been found to be the best approach for meeting the requirement to deliver 120 V dc to the user interface. The architecture minimizes mass and power losses while improving element-to-element isolation and system flexibility. The design is partitioned into three elements: energy collection, storage and conversion, system protection and distribution, and management and control.

Javidi, S.↗

Techno-Economic Analysis of an LGFCS MWe-Class SOFC System (Final Report)

The objective of this project is to perform a range of technical, cost and economic analyses of a MW-scale natural gas fired Solid Oxide Fuel Cell (SOFC) distributed power generation system design. The information generated will provide evidence of the tracking of technology and manufacturing readiness supportive of Technology Readiness Level 7 (TRL7) system testing in the 2022 timeframe that meets the Department of Energy’s (DOE) targets for cost (<$6000/kW) and durability (<0.5% power degradation/1000 hours).

01 COAL, LIGNITE, AND PEAT↗

Load converter interactions with the secondary system in the Space Station Freedom power management and distribution DC test bed

The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF Program design and development phases, a system Power Management and Distribution (PMAD) DC test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

Lebron, Ramon C.↗

Load converter interactions with the secondary system in the Space Station Freedom power management and distribution dc test bed

The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF program design and development phases, a system Power Management and Distribution (PMAD) dc test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

Lebron, Ramon C.↗

Application of a reversible chemical reaction system to solar thermal power plants

Three distributed dish solar thermal power systems using various applications of SO2/SO3 chemical energy storage and transport technology were comparatively assessed. Each system features various roles for the chemical system: (1) energy storage only, (2) energy transport, or (3) energy transport and storage. These three systems were also compared with the dish-Stirling, using electrical transport and battery storage, and the central receiver Rankine system, with thermal storage, to determine the relative merit of plants employing a thermochemical system. As an assessment criterion, the busbar energy costs were compared. Separate but comparable solar energy cost computer codes were used for distributed receiver and central receiver systems. Calculations were performed for capacity factors ranging from 0.4 to 0.8. The results indicate that SO2/SO3 technology has the potential to be more cost effective in transporting the collected energy than in storing the energy for the storage capacity range studied (2-15 hours)

Hanseth, E. J.↗

Multi-Time Step Service Restoration for Advanced Distribution Systems and Microgrids

Modern power systems are facing increased risk of disasters that can cause extended outages. The presence of remote control switches (RCSs), distributed generators (DGs), and energy storage systems (ESS) provides both challenges and opportunities for developing post-fault service restoration methodologies. Inter-temporal constraints of DGs, ESS, and loads under cold load pickup (CLPU) conditions impose extra complexity on problem formulation and solution. In this paper, a multi-time step service restoration methodology is proposed to optimally generate a sequence of control actions for controllable switches, ESSs, and dispatchable DGs to assist the system operator with decision making. The restoration sequence is determined to minimize the unserved customers by energizing the system step by step without violating operational constraints at each time step. The proposed methodology is formulated as a mixed-integer linear programming (MILP) model and can adapt to various operation conditions. Furthermore, the proposed method is validated through several case studies that are performed on modified IEEE 13-node and IEEE 123-node test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variability of Load and Net Load in Case of Large Scale Distributed Wind Power

Large scale wind power production and its variability is one of the major inputs to wind integration studies. This paper analyses measured data from large scale wind power production. Comparisons of variability are made across several variables: time scale (10-60 minute ramp rates), number of wind farms, and simulated vs. modeled data. Ramp rates for Wind power production, Load (total system load) and Net load (load minus wind power production) demonstrate how wind power increases the net load variability. Wind power will also change the timing of daily ramps.

17 WIND ENERGY↗

A Scalable Transmission and Distribution Co-simulation Platform for IBR-heavy Power Systems

The integration of Inverter-Based Resources (IBRs) into power systems, including both transmission and distribution networks, poses challenges for studying grid dynamic behaviours under various operating conditions and system events. This paper addresses the urgent need to investigate the influence of IBRs on grid dynamics, and their potential to enhance power system reliability and resilience. We propose a flexible, scalable transmission and distribution co-simulation platform, using opensource tools only for assessing the impact of grid-following (GFL) and grid-forming (GFM) IBRs on dynamic stability at various renewable penetration levels (up to 100%). This platform enables researchers to explore different contingencies at transmission, distribution, or both, providing a comprehensive evaluation of grid status. A series of case studies, including both small and large T&D systems with varying GFL/GFM configurations and contingencies, have been conducted. The results not only robustly validate our co-simulation framework, but also provide invaluable insights for effective IBR management in the power grid.

grid management↗

Application of multi-function display and control technology

The NASA orbiter spacecraft incorporates a complex array of systems, displays, and controls. The incorporation of discrete dedicated controls into a multifunction display and control system (MFDCS) offers the potential for savings in weight, power, panel space, and crew training time. Technology identified as applicable to a MFDCS is applied to the orbiter orbital maneuvering system (OMS) and the electrical power distribution and control system (EPDCS) to derive concepts for a MFDCS design. Several concepts of varying degrees of performance and complexity are discussed and a suggested concept for further development is presented in greater detail. Both the hardware and software aspects and the human factors considerations of the designs are included.

Spiger, R. J.↗

Space commercialization and power system technology

The development and application of power and energy technologies important to the commercialization of space is discussed, stressing the significance of these technologies to space transportation systems, on-orbit services and on-orbit commercial production and processing ventures. Energy conversion systems examined include solar photovoltaic systems, solar thermal dynamic power systems, and nuclear power systems. Energy storage systems include electrochemical systems, inertial storage systems, and magnetic energy storage systems. In addition, power management and distribution systems used in space commercialization and NASA programs for the commercial development of space are discussed.

Brandhorst, H., Jr.↗

OSU High Temperature Test Facility Design Technical Report, Revision 2

The HTTF is an integral test facility, which has been designed to model the behavior of interest for a MHTGR during the Depressurized Conduction Cooldown (DCC) event. It also has the potential to conduct limited explorations into the progression of the Pressurized Conduction Cooldown (PCC) event and phenomena during normal operations. The facility is scaled 1:4 by height and 1:64 by volume. A scaling report has been developed and provides further detail into the scaling analysis for the HTTF. The maximum core power for the facility is approximately 2.2MW. The core region will be of a modular design to allow for both the prismatic block core and the pebble bed core designs to be tested. However, only the prismatic block design is discussed in this report. The HTTF consists of the following systems: A primary system consisting of the reactor pressure vessel (RPV), the circulator, cross over ducts and primary piping. The core internals sit inside the RPV and provide support for the core and core heaters. The purpose of the primary system is to maintain the pressure boundary, remove heat from the core through convection, conduction and radiation, and provide heat to the core through a series of electrical heaters. A secondary system consisting of a steam generator, feed water system and main steam system. The purpose of the secondary system is to remove heat from the primary system during heat up, cool down and normal operations. A reactor cavity simulation system consisting of a cavity tank, gas conditioning system and a series of break valves. Note that the prototypical MHTGR sits inside of a cavity. In the event of a break the helium will blowdown into this cavity. At the HTTF, the cavity is modeled as a separate tank, the reactor cavity simulation tank (RCST) and is connected to the RPV through break valves—hot-leg, cold-leg, upper break, and lower break. A reactor cavity cooling system (RCCS) consisting of a series of water cooled panels and the water supply system for these panels. The HTTF RCCS is not a scaled prototypical RCCS system for the MHTGR. It is provided in the HTTF in order to set the boundary condition for radiation heat transfer from the RPV. Various auxiliary systems including the city water supply system, the electrical power supply and distribution system, the chilled water system and the instrument air system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Plan for Revolutionary Change in Gas Turbine Engine Control System Architecture

The implementation of Distributed Engine Control technology on the gas turbine engine has been a vexing challenge for the controls community. A successful implementation requires the resolution of multiple technical issues in areas such as network communications, power distribution, and system integration, but especially in the area of high temperature electronics. Impeding the achievement has been the lack of a clearly articulated message about the importance of the distributed control technology to future turbine engine system goals and objectives. To resolve these issues and bring the technology to fruition has, and will continue to require, a broad coalition of resources from government, industry, and academia. This presentation will describe the broad challenges facing the next generation of advanced control systems and the plan which is being put into action to successfully implement the technology on the next generation of gas turbine engine systems.

Culley, Dennis E.↗

Integrating High Penetrations of PV into Southern California

California regulators recently approved a plan proposed by Southern California Edison (SCE) to install 500 MW of distributed photovoltaic (PV) energy in its utility service territory over the next 5 years. The installations will include 250 MW of utility-owned solar and 250 MW of independently owned solar. SCE expects that the majority of these systems will be commercial-scale rooftop PV systems connected at various points in the distribution system. Each of the SCE rooftop PV systems will typically have a rating of 1-3 MW. To understand the impact of high-penetration PV on the distribution grid, the National Renewable Energy Laboratory (NREL) and SCE brought together a team of experts in resource assessment, distribution modeling, and planning to help analyze the impacts of adding high penetration of PV into the distribution system. Through modeling and simulation, laboratory testing, and field demonstrations, the team will address the issues identified in the analysis by fully examining the challenges, developing solutions, and transitioning those solutions to the field for large-scale deployment. This paper gives an update on the project and discusses technical results of integrating a large number of distributed PV systems into the grid.

14 SOLAR ENERGY↗

Learning Behavior of Distribution System Discrete Control Devices for Cyber-Physical Security

Conventional cyber-security intrusion detection systems monitor network traffic for malicious activity and indications that an adversary has gained access to the system. The approach discussed here expands the idea of a traditional intrusion detection system within electrical power systems, specifically power distribution networks, by monitoring the physical behavior of the grid. This is achieved through the use of high-rate distribution Phasor Measurement Units (PMUs), alongside SCADA packets analysis, for the purpose of monitoring the behavior of discrete control devices. In this work we present a set of algorithms for passively learning the control logic of voltage regulators and switched capacitor banks. Upon detection of an abnormal operation, the operator is alerted and further action can be taken. Finally, the proposed learning algorithms are validated on both simulated data and on measured PMU data from a utility pilot deployment site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cyber Threat Landscape for Distribution Systems

INL cyber analysts will present an overview of the current threat landscape for distribution systems. We will begin with examples of known attacks that have occurred recently to motivate the threat analysis and mitigation discussed in the remainder of the presentation. Examples may include the attacks affecting wind plants in Europe in Spring 2022, ransomware attacks on city utilities and commercial distribution systems, and advanced persistent threats (APTs) including the attacks on Ukrainian electric system in 2015 and 2016, as well as more recent evidence of other APT activity. We will present the end-to-end attack paths and discuss the various attacker skills, financing, motivations, and access that contributed to these attacks. In the second part of this presentation, we will discuss mitigating the cyber threats for distribution systems. We will discuss recent publicly disclosed vulnerabilities and explain their relevant context for distribution system security. Likely attacks to affect distribution systems, such as denial-of-service (DoS), ransomware, edge-device compromise, and advanced persistent threats (APTs) will be described. In addition to an overview of these kinds of attacks, we will provide examples of the various ways in which these attacks can start and what systems they can affect. Simple, cost-effective counter-measures to these attacks will be discussed and we will emphasize how these mitigations can reduce threats when properly applied and maintained.

24 POWER TRANSMISSION AND DISTRIBUTION↗