Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Posture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Relation of motion sickness susceptibility to vestibular and behavioral measures of orientation

The objective of this proposal is to determine the relationship of motion sickness susceptibility to vestibulo-ocular reflexes (VOR), motion perception, and behavioral utilization of sensory orientation cues for the control of postural equilibrium. The work is focused on reflexes and motion perception associated with pitch and roll movements that stimulate the vertical semicircular canals and otolith organs of the inner ear. This work is relevant to the space motion sickness problem since 0 g related sensory conflicts between vertical canal and otolith motion cues are a likely cause of space motion sickness. Results of experimentation are summarized and modifications to a two-axis rotation device are described. Abstracts of a number of papers generated during the reporting period are appended.

Peterka, Robert J.↗

Up-down asymmetry of vertical optokinetic nystagmus and after-nystagmus elicited in microgravity

Vertical optokinetic nystagmus (OKN) and optokinetic after-nystagmus (OKAN) studied in 4 subjects during parabolic flights were compared with data obtained on 2 subjects before, during, and after a 7-day space shuttle flight. In parabolic flight, the vertical OKAN following upgoing optokinetic stimulation increased during the 0 g phase, and decreased during the 1.8 g phase. In spaceflight, the vertical OKN gain asymmetry showed a reversal during early exposure to microgravity. This asymmetry reversal is likely the same effect seen in parabolic flight and could be a direct response to the change in otolithic output. However, if asymmetry changes were due only to the otolithic sensory input, we would also expect large changes upon return to normal gravity. Instead, there were large OKN and OKAN changes at the beginning of the flight, but the deviation from the original vertical OKN gain asymmetry constantly decreased throughout the flight and continued post-flight until pre-flight asymmetry value was restored. This suggests one adaptive goal which reinstates the original pre-flight gain and asymmetry value regardless of changing inputs. This adaptation resembles mechanisms seen in posture experiments where the motor programs on Earth are reinstated in microgravity after a period of adjustment.

Clement, Gilles↗

Centrifuges in gravitational physiology research

Data from space flight and ground based experiments have clearly demonstrated the importance of Earth gravity for normal physiological function in man and animals. Gravitational Physiology is concerned with the role and influence of gravity on physiological systems. Research in this field examines how we perceive and respond to gravity and the mechanisms underlying these responses. Inherent in our search for answers to these questions is the ability to alter gravity, which is not physically possible without leaving Earth. However, useful experimental paradigms have been to modify the perceived force of gravity by changing either the orientation of subjects to the gravity vector (i.e., postural changes) or by applying inertial forces to augment the magnitude of the gravity vector. The later technique has commonly been used by applying centripetal force via centrifugation.

Ballard, Rodney W.↗

Effect of antiorthostatic BedRest (BR) on GastroIntestinal Motility (GIM) of normal subjects

The combined effects of postural changes, fluid shifts and diuresis associated with the absence of the gravity vector may decrease gastrointestinal motility (GIM) during space flight. GIM can be estimated from the mouth to cecum transit time (MCTT) of orally administered lactulose (LAC); this test is used to assess changes in GIM in normal subjects and in patients with GI pathology and related disease conditions. Since bedrest (BR) mimics some of the physiological changes that occur during space flight, the effect of ten days of BR on GIM was evaluated from the MCTT of LAC. Methods: Subjects were 12 nonsmoking males between the ages of 35 and 50. After an 8-10 hour fast, subjects ingested Cephulac (registered) (20 g solution) with a low-fiber breakfast on four different days (45, 30, 25, and 20) before BR and on three separate days (4, 7, and 10) during BR. Breath-H2 concentrations were measured before and at 10 minute intervals for 4 hours after breakfast using a Quintron breathalyzer and MCTT was determined from these data. Results: MCTT ranged between 10 and 122 minutes during ambulation and 80 to 120 minutes during BR with means of 79 minutes and 122 minutes respectively. Conclusion: Mean MCTT during BR was 54 percent longer than during ambulation, suggesting that absorption and availability of orally administered medications and nutrients may be delayed or impaired as a result of decreased GIM during bedrest.

Putcha, L.↗

Delivery of cardiopulmonary resuscitation in the microgravity environment

The microgravity environment presents several challenges for delivering effective cardiopulmonary resuscitation (CPR). Chest compressions must be driven by muscular force rather than by the weight of the rescuer's upper torso. Airway stabilization is influenced by the neutral body posture. Rescuers will consist of crew members of varying sizes and degrees of physical deconditioning from space flight. Several methods of CPR designed to accommodate these factors were tested in the one G environment, in parabolic flight, and on a recent shuttle flight. Methods: Utilizing study participants of varying sizes, different techniques of CPR delivery were evaluated using a recording CPR manikin to assess adequacy of compressive force and frequency. Under conditions of parabolic flight, methods tested included conventional positioning of rescuer and victim, free floating 'Heimlich type' compressions, straddling the patient with active and passive restraints, and utilizing a mechanical cardiac compression assist device (CCAD). Multiple restrain systems and ventilation methods were also assessed. Results: Delivery of effective CPR was possible in all configurations tested. Reliance on muscular force alone was quickly fatiguing to the rescuer. Effectiveness of CPR was dependent on technique, adequate restraint of the rescuer and patient, and rescuer size and preference. Free floating CPR was adequate but rapidly fatiguing. The CCAD was able to provide adequate compressive force but positioning was problematic. Conclusions: Delivery of effective CPR in microgravity will be dependent on adequate resuer and patient restraint, technique, and rescuer size and preference. Free floating CPR may be employed as a stop gap method until patient restraint is available. Development of an adequate CCAD would be desirable to compensate for the effects of deconditioning.

Barratt, M. R.↗

Lung volumes during sustained microgravity on Spacelab SLS-1

Gravity is known to influence the topographical gradients of pulmonary ventilation, perfusion, and pleural pressures. The effect of sustained microgravity on lung volumes has not previously been investigated. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box and flowmeter system and a respiratory mass spectrometer. Measurements of tidal volume (V(sub T)), expiratory reserve volume (ERV), inspiratory and expiratory vital capacities (IVC, EVC), functional residual capacity (FRC), and residual volume (RV) were made. During microgravity, V(sub T) decreased by 15%. IVC and EVC were slightly reduced during the first 24 hrs of microgravity and returned to 1 g standing values within 72 hrs after the onset of microgravity. FRC was reduced by 15% and ERV decreased by 10-20%. RV was significantly reduced by 18%. The reductions in FRC, ERV, and V(sub T) during microgravity are probably due to the cranial shift of the diaphragm and an increase in intrathoracic blood volume.

Elliott, Ann R.↗

Relation of motion sickness susceptibility to vestibular and behavioral measures of orientation

The objective is to determine the relationship of motion sickness susceptibility to vestibulo-ocular reflexes (VOR), motion perception, and behavioral utilization of sensory orientation cues for the control of postural equilibrium. The work is focused on reflexes and motion perception associated with pitch and roll movements that stimulate the vertical semicircular canals and otolith organs of the inner ear. This work is relevant to the space motion sickness problem since 0 g related sensory conflicts between vertical canal and otolith motion cues are a likely cause of space motion sickness.

Peterka, Robert J.↗

Evaluation of restraint system concepts for the Japanese Experiment Module flight demonstration

The current International Space Station configuration includes a Japanese Experiment Module which relies on a large manipulator and a smaller dexterous manipulator to operate outside the pressurized environment of the experiment module. The module's flight demonstration is a payload that will be mounted in the aft flight deck on STS-87 to evaluate a prototype of the dexterous manipulator. Since the payload operations entail two 8-hour scenarios on consecutive days, adequate operator restraint at the workstation will be critical to the perceived success or failure of the payload. Simulations in reduced gravity environment on the KC-135A were the only way to evaluate the restraint systems and workstation configuration. Two astronaut and two non-astronaut operators evaluated the Advanced Lower Body Extremities Restraint Test and a foot loop restraint system by performing representative tasks at the workstation in each of the two restraint systems; at the end of each flight they gave their impressions of each system and the workstation. Results indicated that access to the workstation switch panels was difficult and manipulation of the hand controllers forced operators too low for optimal viewing of the aft flight deck monitors. The workstation panel should be angled for better visibility, and infrequently used switches should be on the aft flight deck panel. Pitch angle and placement of the hand controllers should optimize the operator's eye position with respect to the monitors. The lower body restraint was preferred over the foot loops because it allowed operators to maintain a more relaxed posture during long-duration tasks, its height adjustability allowed better viewing of aft flight deck monitors, and it provided better restraint for reacting forces imparted on the operator at the workstation. The foot loops provide adequate restraint for the flight demonstration tasks identified. Since results will impact the design of the workstation, both restraints should be flown and used during operation of the flight demonstration payload to evaluate the effect of restraint during long-duration tasks.

Sampaio, Carlos E.↗

A unique exercise facility for simulating orbital extravehicular activity

A unique exercise facility has been developed and used to simulate orbital extravehicular activity (EVA). The device incorporates an arm ergometer into a mechanism which places the subject in the zero-g neutral body posture. The intent of this configuration is to elicit muscular, cardiovascular, respiratory, and thermoregulatory responses similar to those observed during orbital EVA. Experiments done with this facility will help characterize the astronaut's dynamic heat balance during EVA and will eventually lead to the development of an automated thermal control system which would more effectively maintain thermal comfort.

Williamson, Rebecca C.↗

Crustaceans as a model for microgravity-induced muscle atrophy

Atrophy of skeletal muscles is a serious problem in a microgravity environment. It is hypothesized that the unloading of postural muscles, which no longer must resist gravity force, causes an accelerated breakdown of contractile proteins, resulting in reduction in muscle mass and strength. A crustacean model using the land crab, Gecarcinus lateralis, to assess the effects of spaceflight on protein meatabolism is presented. The model is compared to a developmentally-regulated atrophy in which a premolt reduction in muscle mass allows the withdrawal of the large claws at molt. The biochemical mechanisms underlying protein breakdown involves both Ca2(+) -dependent and multicatalytic proteolytic enzymes. Crustacean claw muscle can be used to determine the interactions between shortening and unloading at the molecular level.

Mykles, D. L.↗

Dynamic analysis of astronaut motions in microgravity: Applications for Extravehicular Activity (EVA)

Simulations of astronaut motions during extravehicular activity (EVA) tasks were performed using computational multibody dynamics methods. The application of computational dynamic simulation to EVA was prompted by the realization that physical microgravity simulators have inherent limitations: viscosity in neutral buoyancy tanks; friction in air bearing floors; short duration for parabolic aircraft; and inertia and friction in suspension mechanisms. These limitations can mask critical dynamic effects that later cause problems during actual EVA's performed in space. Methods of formulating dynamic equations of motion for multibody systems are discussed with emphasis on Kane's method, which forms the basis of the simulations presented herein. Formulation of the equations of motion for a two degree of freedom arm is presented as an explicit example. The four basic steps in creating the computational simulations were: system description, in which the geometry, mass properties, and interconnection of system bodies are input to the computer; equation formulation based on the system description; inverse kinematics, in which the angles, velocities, and accelerations of joints are calculated for prescribed motion of the endpoint (hand) of the arm; and inverse dynamics, in which joint torques are calculated for a prescribed motion. A graphical animation and data plotting program, EVADS (EVA Dynamics Simulation), was developed and used to analyze the results of the simulations that were performed on a Silicon Graphics Indigo2 computer. EVA tasks involving manipulation of the Spartan 204 free flying astronomy payload, as performed during Space Shuttle mission STS-63 (February 1995), served as the subject for two dynamic simulations. An EVA crewmember was modeled as a seven segment system with an eighth segment representing the massive payload attached to the hand. For both simulations, the initial configuration of the lower body (trunk, upper leg, and lower leg) was a neutral microgravity posture. In the first simulation, the payload was manipulated around a circular trajectory of 0.15 m radius in 10 seconds. It was found that the wrist joint theoretically exceeded its ulnal deviation limit by as much as 49. 8 deg and was required to exert torques as high as 26 N-m to accomplish the task, well in excess of the wrist physiological limit of 12 N-m. The largest torque in the first simulation, 52 N-m, occurred in the ankle joint. To avoid these problems, the second simulation placed the arm in a more comfortable initial position and the radius and speed of the circular trajectory were reduced by half. As a result, the joint angles and torques were reduced to values well within their physiological limits. In particular, the maximum wrist torque for the second simulation was only 3 N-m and the maximum ankle torque was only 6 N-m.

Newman, Dava J.↗

Development and implementation of Inflight Neurosensory Training for Adaptation/Readaptation (INSTAR)

Resolution of space motion sickness, and improvements in spatial orientation, posture and motion control, and compensatory eye movements occur as a function of neurosensory and sensorimotor adaptation to microgravity. These adaptive responses, however, are inappropriate for return to Earth. Even following relatively brief space Shuttle missions, significant re-adaptation disturbances related to visual performance, locomotion, and perceived self-motion have been observed. Russian reports suggest that these disturbances increase with mission duration and may be severe following landing after prolonged microgravity exposure such as during a voyage to Mars. Consequently, there is a need to enable the astronauts to be prepared for and more quickly re-adapt to a gravitational environment following extended space missions. Several devices to meet this need are proposed including a virtual environment - centrifuge device (VECD). A short-arm centrifuge will provide centripetal acceleration parallel to the astronaut's longitudinal body axis and a restraint system will be configured to permit head movements only in the plane of rotation (to prevent 'cross-coupling'). A head-mounted virtual environment system will be used to develop appropriate 'calibration' between visual motion/orientation signals and inertial motion/orientation signals generated by the centrifuge. This will permit vestibular, visual and somatosensory signal matches to bias central interpretation of otolith signals toward the 'position' responses and to recalibrate the vestibulo-ocular reflex (VOR).

Harm, D. L.↗

Increased beta-adrenergic responsiveness induced by 14 days exposure to simulated microgravity

Increased sensitivity of end-organ responses to neuroendocrine stimuli as a result of prolonged exposure to the relative inactivity of microgravity has recently been hypothesized. This notion is based on the inverse relationship between circulating norepinephrine and beta-adrenoreceptor sensitivity. The beta-adrenoreceptor activity is reduced in individuals who have elevated plasma norepinephrine as a result of regular exposure to upright posture and physical exercise. In contrast, adrenoreceptor hypersensitivity has been reported in patients with dysautonomias in which circulating catecholamines are absent or reduced. Taken together, these studies and the observation that circulating plasma norepinephrine has been reduced during spaceflight and in groundbased simulations of microgravity prompt the suggestion that adrenoreceptor hypersensitivity may be a consequence of the adaptation to spaceflight. We conducted an experiment designed to measure cardiovascular responses to adrenoreceptor agonists in human subjects before and after prolonged exposure to 6 deg head-down tilt (HDT) to test the hypothesis that adaptation to microgravity increases adrenoreceptor responsiveness, and that this adaptation is associated with reduced levels of circulating norepinephrine.

Convertino, V. A.↗

Ultrasound measurement of transcranial distance during head-down tilt

Exposure to microgravity elevates blood pressure and flow in the head, which may increase intracranial volume (ICV) and intracranial pressure (ICP). Rhesus monkeys exposed to simulated microgravity in the form of 6 degree head-down tilt (HDT) experience elevated ICP. With humans, twenty-four hours of 6 degree HDT bed rest increases cerebral blood flow velocity relative to pre-HDT upright posture. Humans exposed to acute 6 degree HDT experiments increased ICP, measured with the tympanic membrane displacement (TMD) technique. Other studies suggest that increased ICP in humans and cats causes measurable cranial bone movement across the sagittal suture. Due to the slightly compliant nature of the cranium, elevation of the ICP will increase ICV and transcranial distance. Currently, several non-invasive approaches to monitor ICP are being investigated. Such techniques include TMD and modal analysis of the skull. TMD may not be reliable over a large range of ICP and neither method is capable of measuring the small changes in pressure. Ultrasound, however, may reliably measure small distance changes that accompany ICP fluctuations. The purpose of our study was to develop and evaluate an ultrasound technique to measure transcranial distance changes during HDT.

Torikoshi, S.↗

Haptic interfaces: Hardware, software and human performance

Virtual environments are computer-generated synthetic environments with which a human user can interact to perform a wide variety of perceptual and motor tasks. At present, most of the virtual environment systems engage only the visual and auditory senses, and not the haptic sensorimotor system that conveys the sense of touch and feel of objects in the environment. Computer keyboards, mice, and trackballs constitute relatively simple haptic interfaces. Gloves and exoskeletons that track hand postures have more interaction capabilities and are available in the market. Although desktop and wearable force-reflecting devices have been built and implemented in research laboratories, the current capabilities of such devices are quite limited. To realize the full promise of virtual environments and teleoperation of remote systems, further developments of haptic interfaces are critical. In this paper, the status and research needs in human haptics, technology development and interactions between the two are described. In particular, the excellent performance characteristics of Phantom, a haptic interface recently developed at MIT, are highlighted. Realistic sensations of single point of contact interactions with objects of variable geometry (e.g., smooth, textured, polyhedral) and material properties (e.g., friction, impedance) in the context of a variety of tasks (e.g., needle biopsy, switch panels) achieved through this device are described and the associated issues in haptic rendering are discussed.

Srinivasan, Mandayam A.↗

Comparison of Extravehicular Mobility Unit (EMU) suited and unsuited isolated joint strength measurements

In this study the strength of subjects suited in extravehicular mobility units (EMU's) - or Space Shuttle suits - was compared to the strength of unsuited subjects. The authors devised a systematic and complete data set that characterizes isolated joint torques for all major joints of EMU-suited subjects. Six joint motions were included in the data set. The joint conditions of six subjects were compared to increase our understanding of the strength capabilities of suited subjects. Data were gathered on suited and unsuited subjects. Suited subjects wore Class 3 or Class 1 suits, with and without thermal micrometeoroid garments (TMG's). Suited and unsuited conditions for each joint motion were compared. From this the authors found, for example, that shoulder abduction suited conditions differ from each other and from the unsuited condition. A second-order polynomial regression model was also provided. This model, which allows the prediction of suited strength when given unsuited strength information, relates the torques of unsuited conditions to the torques of all suited conditions. Data obtained will enable computer modeling of EMU strength, conversion from unsuited to suited data, and isolated joint strength comparisons between suited and unsuited conditions at any measured angle. From these data mission planners and human factors engineers may gain a better understanding of crew posture, and mobility and strength capabilities. This study also may help suit designers optimize suit strength, and provide a foundation for EMU strength modeling systems.

Maida, James C.↗

Upper Body Venous Compliance Exceeds Lower Body Venous Compliance in Humans

Human venous compliance hypothetically decreases from upper to lower body as a mechanism for maintenance of the hydrostatic indifference level 'headward' in the body, near the heart. This maintains cardiac filling pressure, and thus cardiac output and cerebral perfusion, during orthostasis. This project entailed four steps. First, acute whole-body tilting was employed to alter human calf and neck venous volumes. Subjects were tilted on a tilt table equipped with a footplate as follows: 90 deg, 53 deg, 30 deg, 12 deg, O deg, -6 deg, -12 deg, -6 deg, O deg, 12 deg, 30 deg, 53 deg, and 90 deg. Tilt angles were held for 30 sec each, with 10 sec transitions between angles. Neck volume increased and calf volume decreased during head-down tilting, and the opposite occurred during head-up tilt. Second, I sought to cross-validate Katkov and Chestukhin's (1980) measurements of human leg and neck venous pressures during whole-body tilting, so that those data could be used with volume data from the present study to calculate calf and neck venous compliance (compliance = (Delta)volume/(Delta)pressure). Direct measurements of venous pressures during postural chances and whole-body tilting confirmed that the local changes in venous pressures seen by Katkov and Chestukhin (1980) are valid. The present data also confirmed that gravitational changes in calf venous pressure substantially exceed those changes in upper body venous pressure. Third, the volume and pressure data above were used to find that human neck venous compliance exceeds calf venous compliance by a factor of 6, thereby upholding the primary hypothesis. Also, calf and neck venous compliance correlated significantly with each other (r(exp 2) = 0.56). Fourth, I wished to determine whether human calf muscle activation during head-up tilt reduces calf venous compliance. Findings from tilting and from supine assessments of relaxed calf venous compliance were similar, indicating that tilt-induced muscle activation is relatively unimportant. Low calf venous compliance probably results from stiffer venous, skeletal muscle, and connective tissues, and better-developed local and central neural controls of venous distensibility. This research establishes that upper-to-lower body reduction of venous compliance can explain headward positioning of the hydrostatic indifference level in humans.

Watenpaugh, Donald E.↗

Clinical Aspects of the Control of Plasma Volume at Microgravity and During Return to One Gravity

Plasma volume is reduced by 10%-20% within 24 to 48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity-induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced VO2max after return to one gravity (1G). Since there is no evidence to suggest plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual spaceflight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a 'resetting' to a lower operating point which acts to limit plasma volume expansion during attempts to increase fluid intake. In groudbase and spaceflight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline 10 operating point. Fluid-loading and LBNP have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective countermeasures for the control of plasma volume in microgravity and during return to one gravity will depend upon testing that can be conducted under standardized controlled baseline condi

Convertino, Victor A.↗