Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A closed-loop phase-locked interferometer for wide bandwidth position sensing

This article describes a position sensitive interferometer with closed-loop control of the reference mirror. A calibrated nanopositioner is used to lock the interferometer phase to the most sensitive point in the interferogram. In this configuration, large low-frequency movements of the sensor mirror can be detected from the control signal applied to the nanopositioner and high-frequency short-range signals can be measured directly from the photodiode. It is demonstrated that these two signals are complementary and can be summed to find the total displacement. The resulting interferometer has a number of desirable characteristics: it is optically simple, does not require polarization or modulation to detect the direction of motion, does not require fringe-counting or interpolation electronics, and has a bandwidth equal to that of the photodiode. Experimental results demonstrate the frequency response analysis of a high-speed positioning stage. The proposed instrument is ideal for measuring the frequency response of nanopositioners, electro-optical components, MEMs devices, ultrasonic devices, and sensors such as surface acoustic wave detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluid-kinetic modeling of a high power density radio frequency inductively coupled positive hydrogen ion source

High power density radio-frequency (RF) inductively coupled positive ion sources are attractive candidates for next-generation neutral beam injection (NBI) systems, where higher injected power and longer pulse lengths are desired without sacrificing source reliability. Operating at absorbed power densities of order $\gt 1~\mathrm{W\,cm}^{-3}$ places these sources in a regime with stronger gas heating, higher dissociation, and non-Maxwellian electron energy distributions. The Large Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma source designed to explore this high power density regime and to provide guidance for a positive ion source upgrade for the DIII-D NBI system. LUPIN is designed to operate at up to 20 kW of RF power at 2 MHz, coupling energy through a cylindrical quartz vessel to achieve target ion current densities of $2100\,\mathrm{A\,m}^{-2}$ . This paper presents fluid-kinetic modeling of LUPIN using the hybrid plasma equipment model where electrons are treated kinetically, and the simulations reveal that electron energy distribution function transitions from nearly Maxwellian in the core to bi-Maxwellian towards the edge. Parametric simulations investigate the effects of RF power, gas pressure, and frequency on plasma density, ion flux, and uniformity. Parametric sweeps reveal that increasing power shifts the primary ionization channel from molecular to atomic with diminishing flux gains due to skin-depth contraction and gas rarefaction. Higher frequency localizes heating and increases $\mathrm{H}_2^+$ and $\mathrm{H}_3^+$ delivery to the grid, while elevated pressure boosts ionization yet hinders ion transport due to increase in collisionality.

inductively coupled plasma↗

General relativity’s energy and positivity: a brief history

I give a brief review of the search for a proper definition of energy in General Relativity (GR), a far from trivial quest, which was only completed after four and a half decades. The equally (or perhaps more) difficult task of establishing its positivity—it was to take another 15 plus years—will then be summarized. Extension to cosmological GR is included. Mention is made of some recent offshoots. An invitation to submit a review to the Proceedings of the Royal Society prompts revisiting a subject of central importance both to GR and to my own past research—its energy definition and positivity. While there are no loose ends left, a summary may be of some use to students and non-experts. Exposure to introductory GR is useful. So, we will divide this survey into two unequal parts: first, the original GR without a cosmological constant, then extend it to the rather different two cases of A ≠ 0

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model-independent analysis of the Fermilab Tevatron turn-by-turn beam position monitor measurements

Coherent transverse beam oscillations in the Tevatron were analyzed with the model-independent analysis (MIA) technique. This allowed one to obtain the model-independent values of coupled betatron amplitudes, phase advances, and dispersion function around the ring from a single dipole kick measurement. In order to solve the MIA mode mixing problem which limits the accuracy of determination of the optical functions, we have developed a new technique of rotational MIA mode untangling. The basic idea is to treat each beam position monitor (BPM) as two BPMs separated in a ring by exactly one turn. This leads to a simple criterion of MIA mode separation: the betatron phase advance between any BPM and its counterpart shifted by one turn should be equal to the betatron tune and therefore should not depend on the BPM position in the ring. Furthermore, we describe a MIA-based technique to locate vibrating magnets in a storage ring.

43 PARTICLE ACCELERATORS↗

Powder diffraction by fixed incident angle reflection using a curved position-sensitive detector

As curved position-sensitive detectors improve in angular resolution, the effects that fixed incident angle reflection have on X-ray diffraction peaks become more apparent. In this study the effects of sample transparency, incident beam height, detector resolution and sample displacement on the intensity, location, width and shape of powder diffraction peaks were examined. The functions describing each of these phenomena are presented and were successfully used to quantitatively model the diffraction peaks collected in this geometry. Three distinct regimes of diffraction peak resolution were identified from the phenomena that limit the peak variance. Pertinent criteria based on experimental parameters have been outlined to classify fixed incident angle reflection experiments into each regime. Guidelines for improvement of experimental resolution and for conducting analysis of data acquired using fixed incident angle reflection geometry and curved position-sensitive detectors are also provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ASIC for High Rate 3D Position Sensitive Detectors

We report on the development of an application specific integrated circuit (ASIC) for 3D position sensitive detectors (3D PSD). The ASIC is designed to operate with pixelated wide bandgap sensors like Cadmium-Zinc-Telluride (CZT), Mercuric Iodide (Hgl2) and Thallium Bromide (TIBr). It measures the amplitudes and timings associated with an ionizing event on 128 anodes, the anode grid, and the cathode. Each channel provides low-noise charge amplification, high-order shaping with peaking time adjustable from 250 ns to 12 {micro}s, gain adjustable to 20 mV/fC or 120 mV/fC (for a dynamic range of 3.2 MeV and 530 keV in CZT), amplitude discrimination with 5-bit trimming, and positive and negative peak and timing detections. The readout can be full or sparse, based on a flag and single- or multi-cycle token passing. All channels, triggered channels only, or triggered with neighbors can be read out thus increasing the rate capability of the system to more than 10 kcps. The ASIC dissipates 330 mW which corresponds to about 2.5 mW per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Arrays of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors: Results From a $4\times 4$ Array Prototype

Position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors offer a unique capability for correcting the response nonuniformities caused by crystal defects. This allowed us to achieve high energy resolution, while using typical-grade commercial CZT crystals with relaxed requirements to their quality, thus reducing the overall cost of detectors. Another advantage of the VFG detectors is that they can be integrated into arrays and used in small compact hand-held instruments or large-area gamma cameras that will enhance detection capability for many practical applications, including nonproliferation, medical imaging, and gamma-ray astronomy. Here in this paper, we present the results from testing small array prototypes coupled with front-end application-specified integrated circuit. Each detector in the array is furnished with 5-mm-wide charge-sensing pads placed near the anode. The pads signals are converted into XY coordinates, which combined with the cathode signals (for Z coordinates) provide 3-D position information of all interaction points. The basic array consists of a number of detectors grouped into 2×2 subarrays, each having a common cathode made by connecting together the cathodes of the individual detectors. Lastly, these features can significantly improve the performance of detectors while using typical-grade low-cost CZT crystals to reduce the overall cost of the proposed instrument.

3-D position-sensitive virtual Frisch-grid (VFG) d↗

Voltage positioning using co-optimization of controllable grid assets in radial networks

With increasing penetration of solar PV, some distribution feeders are experiencing highly variable net-load flows and even reverse flows. To optimize distribution systems under such conditions, the scheduling of mechanical devices, such as OLTCs and capacitor banks, needs to take into account forecasted solar PV and actual grid conditions. However, these legacy switching assets are operated on a daily or hourly timescale, due to the wear and tear associated with mechanical switching, which makes them unsuitable for real-time control. Therefore, there is a natural timescale- separation between these slower mechanical assets and the responsive nature of inverter-based resources. In this paper, we present a network admissible convex formulation for holistically scheduling controllable grid assets to position voltage optimally against solar PV. An optimal hourly schedule is presented that utilizes mechanical resources to position the predicted voltages close to nominal values, while minimizing the use of inverter-based resources (i.e., DERs), making them available for control at a faster time-scale (after the uncertainty reveals itself). A convex, inner approximation of the OPF problem is adapted to a mixed-integer linear program that minimizes voltage deviations from nominal (i.e., maximizes voltage margins). Here, the resulting OPF solution respects all the network constraints and is, hence, robust against modeling simplifications. Simulation based analysis on IEEE distribution feeders validates the approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged images for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction, seven required a single correction, one required two corrections, and one required three corrections. Mean residual GTV deviation (3D distance) following GTV-based systematic correction (mean {+-} 1 standard deviation 4.8 {+-} 1.5 mm) is significantly lower than for systematic skeletal-based (6.5 {+-} 2.9 mm, p= 0.015), and weekly skeletal-based correction (7.2 {+-} 3.0 mm, p= 0.001), but is not significantly lower than daily skeletal-based correction (5.4 {+-} 2.6 mm, p= 0.34). In two cases, first-day CBCT images reveal tumor changes-one showing tumor growth, the other showing large tumor displacement-that are not readily observed in radiographs. Differences in computed GTV deviations between respiration-correlated and respiration-averaged images are 0.2 {+-} 1.8 mm in the superior-inferior direction and are of similar magnitude in the other directions. Conclusions: An off-line protocol to correct GTV-based systematic error in locally advanced lung tumor cases can be effective at reducing tumor deviations, although the findings need confirmation with larger patient statistics. In some cases, a single cone-beam CT can be useful for assessing tumor changes early in treatment, if more than a few days elapse between simulation and the start of treatment. Tumor deviations measured with respiration-averaged CT and CBCT images are consistent with those measured with respiration-correlated images; the respiration-averaged method is more easily implemented in the clinic.

60 APPLIED LIFE SCIENCES↗

Is ExacTrac x-ray system an alternative to CBCT for positioning patients with head and neck cancers?

Purpose: To evaluate the usefulness of a six-degrees-of freedom (6D) correction using ExacTrac robotics system in patients with head-and-neck (HN) cancer receiving radiation therapy.Methods: Local setup accuracy was analyzed for 12 patients undergoing intensity-modulated radiation therapy (IMRT). Patient position was imaged daily upon two different protocols, cone-beam computed tomography (CBCT), and ExacTrac (ET) images correction. Setup data from either approach were compared in terms of both residual errors after correction and punctual displacement of selected regions of interest (Mandible, C2, and C6 vertebral bodies).Results: On average, both protocols achieved reasonably low residual errors after initial correction. The observed differences in shift vectors between the two protocols showed that CBCT tends to weight more C2 and C6 at the expense of the mandible, while ET tends to average more differences among the different ROIs.Conclusions: CBCT, even without 6D correction capabilities, seems preferable to ET for better consistent alignment and the capability to see soft tissues. Therefore, in our experience, CBCT represents a benchmark for positioning head and neck cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-term stability of the Leksell Gamma Knife{sup ®} Perfexion™ patient positioning system (PPS)

Purpose: To assess the long-term mechanical stability and accuracy of the patient positioning system (PPS) of the Leksell Gamma Knife{sup ®} Perfexion™ (LGK PFX). Methods: The mechanical stability of the PPS of the LGK PFX was evaluated using measurements obtained between September 2007 and June 2011. Three methods were employed to measure the deviation of the coincidence of the radiological focus point (RFP) and the PPS calibration center point (CCP). In the first method, the onsite diode test tool with single diode detector was used together with the 4 mm collimator on a daily basis. In the second method, a service diode test tool with three diode detectors was used biannually at the time of the routine preventive maintenance. The test performed with the service diode test tool measured the deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. The third method employed the conventional film pin-prick method. This test was performed annually for the 4 mm collimator at the time of the routine annual QA. To estimate the effect of the patient weight on the performance of the PPS, the focus precision tests were also conducted with varying weights on the PPS using a set of lead bricks. Results: The average deviations measured from the 641 daily focus precision tests were 0.1 ± 0.1, 0.0 ± 0.0, and 0.0 ± 0.0 mm, respectively, for the 4 mm collimator in the X (left/right of the patient), Y (anterior/posterior of the patient), and Z (superior/inferior of the patient) directions. The average of the total radial deviations as measured during ten semiannual measurements with the service diode test tool were 0.070 ± 0.029, 0.060 ± 0.022, and 0.103 ± 0.028 mm, respectively for the central, long, and short diodes for the 4 mm collimator. Similarly, the average total radial deviations measured during the semiannual measurements for the 4, 8, and 16 mm collimators and using the central diode were 0.070 ± 0.029, 0.097 ± 0.025, 0.159 ± 0.028 mm, respectively. The average values of the deviations as obtained from the five annual film pin-prick tests for the 4 mm collimator were 0.10 ± 0.06, 0.06 ± 0.09, and 0.03 ± 0.03 mm for the X, Y, Z stereotactic directions, respectively. Only a minor change was observed in the total radial deviations of the PPS as a function of the simulated patient weight up to 202 kg on the PPS. Conclusions: Excellent long-term mechanical stability and high accuracy was observed for the PPS of the LGK PFX. No PPS recalibration or any adjustment in the PPS was needed during the monitored period of time. Similarly, the weight on the PPS did not cause any significant disturbance in the performance of the PPS for up to 202 kg simulated patient weight.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Note: Millimeter precision in ultrasound based patient positioning: Experimental quantification of inherent technical limitations

Purpose: To identify the relevant technical sources of error of a system based on three-dimensional ultrasound (3D US) for patient positioning in external beam radiotherapy. To quantify these sources of error in a controlled laboratory setting. To estimate the resulting end-to-end geometric precision of the intramodality protocol. Methods: Two identical free-hand 3D US systems at both the planning-CT and the treatment room were calibrated to the laboratory frame of reference. Every step of the calibration chain was repeated multiple times to estimate its contribution to overall systematic and random error. Optimal margins were computed given the identified and quantified systematic and random errors. Results: In descending order of magnitude, the identified and quantified sources of error were: alignment of calibration phantom to laser marks 0.78 mm, alignment of lasers in treatment vs planning room 0.51 mm, calibration and tracking of 3D US probe 0.49 mm, alignment of stereoscopic infrared camera to calibration phantom 0.03 mm. Under ideal laboratory conditions, these errors are expected to limit ultrasound-based positioning to an accuracy of 1.05 mm radially. Conclusions: The investigated 3D ultrasound system achieves an intramodal accuracy of about 1 mm radially in a controlled laboratory setting. The identified systematic and random errors require an optimal clinical tumor volume to planning target volume margin of about 3 mm. These inherent technical limitations do not prevent clinical use, including hypofractionation or stereotactic body radiation therapy.

60 APPLIED LIFE SCIENCES↗

Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications.

60 APPLIED LIFE SCIENCES↗

A new look at the position operator in quantum theory

The postulate that coordinate and momentum representations are related to each other by the Fourier transform has been accepted from the beginning of quantum theory by analogy with classical electrodynamics. As a consequence, an inevitable effect in standard theory is the wave packet spreading (WPS) of the photon coordinate wave function in directions perpendicular to the photon momentum. This leads to the following paradoxes: if the major part of photons emitted by stars are in wave packet states (what is the most probable scenario) then we should see not separate stars but only an almost continuous background from all stars; no anisotropy of the CMB radiation should be observable; data on gamma-ray bursts, signals from directional radio antennas (in particular, in experiments on Shapiro delay) and signals from pulsars show no signs of WPS. In addition, a problem arises why there are no signs of WPS for protons in the LHC ring. We argue that the above postulate is based neither on strong theoretical arguments nor on experimental data and propose a new consistent definition of the position operator. Then WPS in directions perpendicular to the particle momentum is absent and the paradoxes are resolved. Different components of the new position operator do not commute with each other and, as a consequence, there is no wave function in coordinate representation. Implications of the results for entanglement, quantum locality and the problem of time in quantum theory are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark phase effect in the evolution of the positive column of a glow discharge in nitrogen

The characteristics of the initial stage of the formation of the positive column of a glow discharge in nitrogen at reduced pressures are studied experimentally and numerically. A dip in the plasma emission intensity in the initial stage of the discharge (the so-called 'dark phase') is observed experimentally at the positive polarity of the high-voltage electrode (the cathode is grounded). The dark phase is preceded by an ionization wave (IW). When the anode is grounded, neither an IW nor a dip in the discharge emission intensity are observed. A theoretical model capable of describing the discharge development under the actual experimental conditions is constructed. It is shown that the dark phase effect may be caused by the high electron density (above the steady-state one) produced in the gas during the passage of the IW across the discharge gap. This mechanism of the dark phase formation differs from the mechanism proposed earlier to explain a similar effect in noble gases. Additional experiments carried out with pure argon, helium, and helium with a nitrogen admixture have shown that, in the case of a grounded cathode, gas breakdown is also accompanied by the passage of an IW, whereas in the case of a grounded anode, no IW is observed; however, the dark phase is present in both cases. It is shown using computer simulations that, in nitrogen (in contrast to noble gases), the mechanism resulting in the dark phase effect does not operate in the absence of an IW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Position-Sensitive Spectrometric Module for Detecting Ionizing Radiation by Semiconductor Strip Detectors

A position-sensitive module for detecting ionizing radiation based on semiconductor strip detectors and a multichannel spectrometric route has been developed and implemented. The dynamic range of the detected charge generated by an ionizing particle in the detector is 5–250 fC. The position-sensitive module is a structurally complete device with the functions of amplifying the spectrometric signal, digitizing, buffering, preprocessing, and transmitting data to a computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Positive Asymptotic-Preserving Scheme for Linear Kinetic Transport Equations

We present a positive- and asymptotic-preserving numerical scheme for solving linear kinetic transport equations that relax to a diffusive equation in the limit of infinite scattering. The proposed scheme is developed using a standard spectral angular discretization and a classical micro-macro decomposition. The three main ingredients are a semi-implicit temporal discretization, a dedicated finite difference spatial discretization, and realizability limiters in the angular discretization. Under mild assumptions, the scheme becomes a consistent numerical discretization for the limiting diffusion equation when the scattering cross-section tends to infinity. The scheme also preserves positivity of the particle concentration on the space-time mesh and therefore fixes a common defect of spectral angular discretizations. The scheme is tested on the well-known line source benchmark problem with the usual uniform material medium as well as a medium composed of different materials that are arranged in a checkerboard pattern. We also tested the scheme on a Riemann problem with a nonuniform material medium. The observed order of space-time accuracy of the proposed scheme is reported.

nite difference methods↗

Cylinder gauge measurement using a position sensitive detector

A position sensitive detector (PSD) has been used to determine the diameter of cylindrical pins based on the shift in a laser beam's centroid. The centroid of the light beam is defined here as the weighted average of position by the local intensity. A shift can be observed in the centroid of an otherwise axially symmetric light beam, which is partially obstructed. Additionally, the maximum shift in the centroid is a unique function of the obstructing cylinder diameter. Thus to determine the cylinder diameter, one only needs to detect this maximum shift as the cylinder is swept across the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗