Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Poisson Ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Radon in Drinking Water and Cancer Mortality: An Ecological Study in Japan

There is limited information on the health effects of radon in drinking water in spite of their potential exposures. We conducted an ecological study in a small town in Japan where the groundwater with high concentrations of radon is supplied as utilities. A total of 607 cancer deaths were ascertained by vital statistics in that town from 1972 to 1997. Standardized mortality ratios on the basis of national rates were 1.01 (95% confidence interval; 0.93-1.09) for all cancers, 1.10 (0.95-1.28) for stomach cancer, 0.88 (0.70-1.10) for lung cancer, and 1.14 (0.87-1.48) for liver cancer. Mortality from liver cancer was significantly higher than that of two surrounding control cities combined, with a relative risk of 1.40 (1.04-1.89) based on Poisson regression analysis. Lack of information on possible confounders including diet, alcohol drinking, smoking and hepatitis virus infection, is the main limitation of the study, which precludes the evaluation of causal associations.

54 ENVIRONMENTAL SCIENCES↗

Measurements of three-flavor neutrino oscillations from a PISCES two-detector fit to the NOvA Experiment data

NOvA is a long-baseline neutrino oscillation experiment with two functionally identical detectors: a Near Detector (ND) at Fermilab, placed 1 km from the neutrino source, and a Far Detector (FD) located 810 km away from the ND in Minnesota. NOvA s primary physics goals are to measure the neutrino oscillation parameters $\theta_{23}$ and $\Delta m^2_{32}$ with high precision, determine the neutrino mass hierarchy, and constrain the value of $\delta_{CP}$, primarily via the study of muon neutrino to electron neutrino oscillation. Extracting values for oscillation parameters from fits to data usually relies on treating systematic uncertainties as nuisance parameters, a strategy that suffers from poor scalability as the number of uncertainties becomes larger. This work introduces PISCES (Parameter Inference with Systematic Covariance and Exact Statistics), a novel method that circumvents this scalability problem by encoding systematic uncertainties into a covariance matrix. PISCES utilizes a nested minimization in which optimal systematic pulls are first computed using the covariance matrix in an inner minimization step, then the oscillation parameters are profiled over in the outer minimization. PISCES also uses a Poisson Likelihood term, making it ideal for the inclusion of low-statistic samples in the fits. PISCES is a flexible framework that also supports complex fits, such as a joint Near and Far detector fit. In the standard NOvA analysis, oscillation parameters are extracted using an extrapolation technique in which the ND data indirectly constrain the FD prediction via a ratio method. PISCES, on the other hand, enables a simultaneous ND+FD fit, allowing the high-statistics ND data to directly constrain systematic uncertainties across all samples. This thesis presents the full PISCES joint ND+FD fit for the NOvA three-flavor analysis, details its implementation, and evaluates its performance through extensive robustness tests and fake data studies. It also provides a comparison between the PISCES joint ND+FD results and the standard NOvA extrapolation method using the full NOvA 10-year data set. The results demonstrate that PISCES can successfully fit NOvA data while incorporating the constraints from the ND detectors consistently, using physically motivated systematic uncertainties to account for data/MC discrepancies.

Rajaoalisoa, Miriama [Cincinnati U.]↗

Number-counts slope estimation in the presence of Poisson noise

The slope determination of a power-law number flux relationship in the case of photon-limited sampling. This case is important for high-sensitivity X-ray surveys with imaging telescopes, where the error in an individual source measurement depends on integrated flux and is Poisson, rather than Gaussian, distributed. A bias-free method of slope estimation is developed that takes into account the exact error distribution, the influence of background noise, and the effects of varying limiting sensitivities. It is shown that the resulting bias corrections are quite insensitive to the bias correction procedures applied, as long as only sources with signal-to-noise ratio five or greater are considered. However, if sources with signal-to-noise ratio five or less are included, the derived bias corrections depend sensitively on the shape of the error distribution.

Schmitt, Juergen H. M. M.↗

Influence of a strong laser field on Coulomb explosion and stopping power of energetic H{sub 3}{sup +} clusters in plasmas

The influence of a high-intensity laser field on the Coulomb explosion and stopping power for a swift H{sub 3}{sup +} cluster ion in a plasma target is studied by means of the molecular dynamic (MD) method based on the linearized Vlasov-Poisson theory. Excitations of the plasma are described by the classical plasma dielectric function. In the presence of the laser field, the general expressions for the induced potential in the target and the interaction force among the ions within the cluster are derived. Based on the numerical solution of the equations of motion for the constituent ions, the Coulomb explosion patterns and the cluster's stopping power are discussed for a range of laser parameters. Numerical results show that the laser field affects the correlation between the ions and contributes to weaken the wake effect and the stopping power as compared to the laser-free case. On the other hand, the stopping power ratio of H{sub 3}{sup +} cluster is higher than the situation of dicluster of H{sub 2}{sup +} due to the vicinage effect in the cluster.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Measurement vs. Counting Errors on Parameters' Covariance in Neutron Tomography Analysis

We present here a method that estimates the relative effect of the counting uncertainty and of the instrument uncertainty on that of the parameters in a parametric model for neutron time of flight. The final result, obtained independently of calculation of the parameter values from measured data, presents explicitly the ratio of the two uncertainties in terms of the choice, settings, and placement of the detector and the oscilloscope. Consequently, the method can serve as a tool in planning a measurement setup.

fusion↗

TH-A-18C-08: Design of a Small Animal Contrast Enhanced Dual Energy CT

Purpose: Dual energy CT has a variety of uses in a small animal setting including quantification and enhanced visualization of contrast agent. This study aims to determine the best energy combinations for contrast enhanced DECT on the XRAD 225Cx (Precision x-ray), a small animal IGRT system with a nominal energy range of 20 – 225 kVp. Focus was placed on material density accuracy and low contrast detectability. Methods: Simulations of single energy scans of an object containing concentrations of iodine varying from 0.5 to 50 mg/ml were performed using the simulation package ImaSim. Energy spectra from 50 – 220 kVp were calculated using the same software. For approximate Poisson noise modeling, mAs were chosen such that 30% of the total 10cGy dose was assigned to the low energy scan. A calibration involving projections of objects containing different thicknesses of iodine (0–0.5 mm) and water (0–50 mm) was performed for each energy and fit to a cubic equation as the calibration curve for each energy pair. Results: Contrast to noise ratios of the iodine material images and accuracies in iodine density measurements were measured. Gradual improvements in each metric were seen with increasing high energy. Larger improvements in CNR were observed for decreasing the low energy. Errors in iodine density were generally close to 5% for concentrations of iodine above 3 mg/ml but increased to around 15% for 50 kVp, likely due to its proximity to the discontinuity caused by the k-edge of iodine. Conclusion: Based on these simulations, the best energy combination for detecting low concentrations of iodine using a projection space calibration procedure is 50/200 kVp. However, if accuracy is most important 80/220 kVp is ideal, with 60/220 kVp being a good compromise to achieve both goals. Future work is necessary to verify these conclusions with physical data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of stratocumulus cloud fields using LANDSAT imagery: Size distributions and spatial separations

Stratocumulus cloud fields in the FIRE IFO region are analyzed using LANDSAT Thematic Mapper imagery. Structural properties such as cloud cell size distribution, cell horizontal aspect ratio, fractional coverage and fractal dimension are determined. It is found that stratocumulus cloud number densities are represented by a power law. Cell horizontal aspect ratio has a tendency to increase at large cell sizes, and cells are bi-fractal in nature. Using LANDSAT Multispectral Scanner imagery for twelve selected stratocumulus scenes acquired during previous years, similar structural characteristics are obtained. Cloud field spatial organization also is analyzed. Nearest-neighbor spacings are fit with a number of functions, with Weibull and Gamma distributions providing the best fits. Poisson tests show that the spatial separations are not random. Second order statistics are used to examine clustering.

Welch, R. M.↗

GAMMA-RAY SPECTRAL PROPERTIES OF MATURE PULSARS: A TWO-LAYER MODEL

We use a simple two-layer outer gap model, whose accelerator consists of a primary region and a screening region, to discuss the {gamma}-ray spectrum of mature pulsars detected by Fermi. By solving the Poisson equation with an assumed simple step-function distribution for the charge density in these two regions, the distribution of the electric field and the curvature radiation process of the accelerated particles can be calculated. In our model, the properties of the phase-averaged spectrum can be completely specified by three gap parameters, i.e., the fractional gap size in the outer magnetosphere, the gap current in the primary region, and the gap size ratio between the primary region and the total gap size. We discuss how these parameters affect the spectral properties. We argue that although the radiation mechanism in the outer gap is a curvature radiation process, the observed gamma-ray spectrum can substantially deviate from the simple curvature spectrum because the overall spectrum consists of two components, i.e., a primary region and a screening region. In some pulsars, the radiation from the screening region is so strong that the photon index from 100 MeV to several GeV can be as flat as {approx}2. We show that the fitting fractional gap thickness of the canonical pulsars increases with the spin-down age. We find that the total gap current is about 50% of the Goldreich-Julian value and the thickness of the screening region is a few percent of the total gap thickness. We also find that the predicted {gamma}-ray luminosity is less dependent on the spin-down power (L{sub sd}) for pulsars with L{sub sd} {approx}> 10{sup 36} erg s{sup -1}, while the {gamma}-ray luminosity decreases with the spin-down power for pulsars with L{sub sd} {approx}< 10{sup 36} erg s{sup -1}. This relation may imply that the major gap closure mechanism is a photon-photon pair-creation process for pulsars with L{sub sd} {approx}> 10{sup 36} erg s{sup -1}, while it is a magnetic pair-creation process for pulsars with {sub sd} {approx}< 10{sup 36} erg s{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Landau damping of ion acoustic wave in Lorentzian multi-ion plasmas

The Landau damping rates of ion acoustic wave are studied by using Vlasov-Poisson model for unmagnetized Lorentzian or kappa distributed plasma containing electrons, positively and negatively charged ions. It is found that the damping rate of ion acoustic wave is increased with the decrease of kappa (i.e., the spectral index of Lorentzian distribution) value. The damping rates of the electrostatic wave in multi-ion component plasmas are discussed in detail which depends on electron to ion temperature ratio and ions masses and density ratios. The numerical results are also shown by choosing some typical experimental parameters of multi-ion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetohydrodynamic motion of a two-fluid plasma

Here, the two-fluid Maxwell system couples frictionless electron and ion fluids via Maxwell’s equations. When the frequencies of light waves, Langmuir waves, and single-particle cyclotron motion are scaled to be asymptotically large, the two-fluid Maxwell system becomes a fast-slow dynamical system. This fast-slow system admits a formally-exact single-fluid closure that may be computed systematically with any desired order of accuracy through the use of a functional partial differential equation. In the leading order approximation, the closure reproduces magnetohydrodynamics (MHD). Higher order truncations of the closure give an infinite hierarchy of extended MHD models that allow for arbitrary mass ratio, as well as perturbative deviations from charge neutrality. The closure is interpreted geometrically as an invariant slow manifold in the infinite-dimensional two-fluid phase space, on which two-fluid motions are free of high-frequency oscillations. This perspective shows that the full closure inherits a Hamiltonian structure from two-fluid theory. By employing infinite-dimensional Lie transforms, the Poisson bracket for the all-orders closure may be obtained in closed form. Thus, conservative truncations of the single-fluid closure may be obtained by simply truncating the single-fluid Hamiltonian. Moreover, the closed-form expression for the all-orders bracket gives explicit expressions for a number of the full closure’s conservation laws. Notably, the full closure, as well as any of its Hamiltonian truncations, admits a pair of independent circulation invariants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparison of two algorithms for simulating collisionless systems

Two completely different simulation algorithms are compared by applying them to the same stellar dynamical problems: one is a self-consistent field (SCF) method for solving Poisson's equation and the other is a phase-space method for integrating the collisionless Boltzmann equation. We consider simulations of spherical stellar systems which are initially far from equilibrium and relax to their final states by gravitational collapse. The initial conditions consist of either uniform-density spheres or nonequilibrium models having Plummer density profiles, in which velocity dispersions are assigned according to given virial ratios. If a few tens of radial expansion terms with hundreds of thousands of particles are used in the SCF code, excellent agreement is found between the results it generates and those obtained with the phase-space solver, provided that a sufficiently large number of grid cells are employed with the latter. These findings imply that for simulating collisionless systmes over many dynamical times, the SCF approach based on sampling phase space is competitive with the approach treating phase space as a continuous fluid. The results of our tests make it possible to estimate the number of particles and basis functions required in situations like those modeled. Limitations of the SCF method and the choice of an optimal set of basis functions are also discussed.

Hozumi, Shunsuke↗

BINARY FREQUENCIES IN A SAMPLE OF GLOBULAR CLUSTERS. I. METHODOLOGY AND INITIAL RESULTS

Binary stars are thought to be a controlling factor in globular cluster evolution, since they can heat the environmental stars by converting their binding energy to kinetic energy during dynamical interactions. Through such interaction, the binaries determine the time until core collapse. To test predictions of this model, we have determined binary fractions for 35 clusters. Here we present our methodology with a representative globular cluster NGC 4590. We use Hubble Space Telescope archival Advanced Camera for Surveys data in the F606W and F814W bands and apply point-spread-function-fitting photometry to obtain high quality color-magnitude diagrams. We formulate the star superposition effect as a Poisson probability distribution function, with parameters optimized through Monte Carlo simulations. A model-independent binary fraction of (6.2 {+-} 0.3)% is obtained by counting stars that extend to the red side of the residual color distribution after accounting for the photometric errors and the star superposition effect. A model-dependent binary fraction is obtained by constructing models with a known binary fraction and an assumed binary mass-ratio distribution function. This leads to a binary fraction range of 6.8%-10.8%, depending on the assumed shape to the binary mass-ratio distribution, with the best fit occurring for a binary distribution that favors low mass ratios (and higher binary fractions). We also represent the method for radial analysis of the binary fraction in the representative case of NGC 6981, which shows a decreasing trend for the binary fraction toward the outside, consistent with theoretical predictions for the dynamical effect on the binary fraction.

79 ASTRONOMY AND ASTROPHYSICS↗

Using compressive sensing to recover images from PET scanners with partial detector rings

Purpose: Most positron emission tomography/computed tomography (PET/CT) scanners consist of tightly packed discrete detector rings to improve scanner efficiency. The authors’ aim was to use compressive sensing (CS) techniques in PET imaging to investigate the possibility of decreasing the number of detector elements per ring (introducing gaps) while maintaining image quality. Methods: A CS model based on a combination of gradient magnitude and wavelet domains (wavelet-TV) was developed to recover missing observations in PET data acquisition. The model was designed to minimize the total variation (TV) and L1-norm of wavelet coefficients while constrained by the partially observed data. The CS model also incorporated a Poisson noise term that modeled the observed noise while suppressing its contribution by penalizing the Poisson log likelihood function. Three experiments were performed to evaluate the proposed CS recovery algorithm: a simulation study, a phantom study, and six patient studies. The simulation dataset comprised six disks of various sizes in a uniform background with an activity concentration of 5:1. The simulated image was multiplied by the system matrix to obtain the corresponding sinogram and then Poisson noise was added. The resultant sinogram was masked to create the effect of partial detector removal and then the proposed CS algorithm was applied to recover the missing PET data. In addition, different levels of noise were simulated to assess the performance of the proposed algorithm. For the phantom study, an IEC phantom with six internal spheres each filled with F-18 at an activity-to-background ratio of 10:1 was used. The phantom was imaged twice on a RX PET/CT scanner: once with all detectors operational (baseline) and once with four detector blocks (11%) turned off at each of 0 °, 90 °, 180 °, and 270° (partially sampled). The partially acquired sinograms were then recovered using the proposed algorithm. For the third test, PET images from six patient studies were investigated using the same strategy of the phantom study. The recovered images using WTV and TV as well as the partially sampled images from all three experiments were then compared with the fully sampled images (the baseline). Comparisons were done by calculating the mean error (%bias), root mean square error (RMSE), contrast recovery (CR), and SNR of activity concentration in regions of interest drawn in the background as well as the disks, spheres, and lesions. Results: For the simulation study, the mean error, RMSE, and CR for the WTV (TV) recovered images were 0.26% (0.48%), 2.6% (2.9%), 97% (96%), respectively, when compared to baseline. For the partially sampled images, these results were 22.5%, 45.9%, and 64%, respectively. For the simulation study, the average SNR for the baseline was 41.7 while for WTV (TV), recovered image was 44.2 (44.0). The phantom study showed similar trends with 5.4% (18.2%), 15.6% (18.8%), and 78% (60%), respectively, for the WTV (TV) images and 33%, 34.3%, and 69% for the partially sampled images. For the phantom study, the average SNR for the baseline was 14.7 while for WTV (TV) recovered image was 13.7 (11.9). Finally, the average of these values for the six patient studies for the WTV-recovered, TV, and partially sampled images was 1%, 7.2%, 92% and 1.3%, 15.1%, 87%, and 27%, 25.8%, 45%, respectively. Conclusions: CS with WTV is capable of recovering PET images with good quantitative accuracy from partially sampled data. Such an approach can be used to potentially reduce the cost of scanners while maintaining good image quality.

60 APPLIED LIFE SCIENCES↗

Facility Activity Inference Using Radiation Networks

We consider the problem of inferring the operational status of a reactor facility using measurements from a radiation sensor network deployed around the facility’s ventilation off-gas stack. The intensity of stack emissions decays with distance, and the sensor counts or measurements are inherently random with parameters determined by the intensity at the sensor’s location. We utilize the measurements to estimate the intensity at the stack, and use it in a one-sided Sequential Probability Ratio Test (SPRT) to infer on/off status of the reactor. We demonstrate the superior performance of this method over conventional majority fusers and individual sensors using (i) test measurements from a network of 21 NaI detectors, and (ii) effluence measurements collected at the stack of a reactor facility. We also analytically establish the superior detection performance of the network over individual sensors with fixed and adaptive thresholds by utilizing the Poisson distribution of the counts. We quantify the performance improvements of the network detection over individual sensors using the packing number of the intensity space.

Rao, Nageswara S.↗

Solution of elliptic PDEs by fast Poisson solvers using a local relaxation factor

A large class of two- and three-dimensional, nonseparable elliptic partial differential equations (PDEs) is presently solved by means of novel one-step (D'Yakanov-Gunn) and two-step (accelerated one-step) iterative procedures, using a local, discrete Fourier analysis. In addition to being easily implemented and applicable to a variety of boundary conditions, these procedures are found to be computationally efficient on the basis of the results of numerical comparison with other established methods, which lack the present one's: (1) insensitivity to grid cell size and aspect ratio, and (2) ease of convergence rate estimation by means of the coefficient of the PDE being solved. The two-step procedure is numerically demonstrated to outperform the one-step procedure in the case of PDEs with variable coefficients.

Chang, Sin-Chung↗

Broadband turbulent spectra in gamma-ray burst light curves

Broadband power density spectra offer a window to understanding turbulent behavior in the emission mechanism and, at the highest frequencies, in the putative inner engines powering long gamma-ray bursts (GRBs). We describe a chirp search method alongside Fourier analysis for signal detection in the Poisson noise-dominated, 2 kHz sampled, BeppoSAX light curves. An efficient numerical implementation is described in O(Nnlog n) operations, where N is the number of chirp templates and n is the length of the light-curve time series, suited for embarrassingly parallel processing. For the detection of individual chirps over a 1 s duration, the method is one order of magnitude more sensitive in signal-to-noise ratio than Fourier analysis. The Fourier-chirp spectra of GRB 010408 and GRB 970816 show a continuation of the spectral slope with up to 1 kHz of turbulence identified in low-frequency Fourier analysis. The same continuation is observed in an average spectrum of 42 bright, long GRBs. An outlook on a similar analysis of upcoming gravitational wave data is included.

79 ASTRONOMY AND ASTROPHYSICS↗

Prostate Stereotactic Ablative Radiation Therapy Using Volumetric Modulated Arc Therapy to Dominant Intraprostatic Lesions

Purpose: To investigate boosting dominant intraprostatic lesions (DILs) in the context of stereotactic ablative radiation therapy (SABR) and to examine the impact on tumor control probability (TCP) and normal tissue complication probability (NTCP). Methods and Materials: Ten prostate datasets were selected. DILs were defined using T2-weighted, dynamic contrast-enhanced and diffusion-weighted magnetic resonance imaging. Four plans were produced for each dataset: (1) no boost to DILs; (2) boost to DILs, no seminal vesicles in prescription; (3) boost to DILs, proximal seminal vesicles (proxSV) prescribed intermediate dose; and (4) boost to DILs, proxSV prescribed higher dose. The prostate planning target volume (PTV) prescription was 42.7 Gy in 7 fractions. DILs were initially prescribed 115% of the PTV{sub Prostate} prescription, and PTV{sub DIL} prescriptions were increased in 5% increments until organ-at-risk constraints were reached. TCP and NTCP calculations used the LQ-Poisson Marsden, and Lyman-Kutcher-Burman models respectively. Results: When treating the prostate alone, the median PTV{sub DIL} prescription was 125% (range: 110%-140%) of the PTV{sub Prostate} prescription. Median PTV{sub DIL} D50% was 55.1 Gy (range: 49.6-62.6 Gy). The same PTV{sub DIL} prescriptions and similar PTV{sub DIL} median doses were possible when including the proxSV within the prescription. TCP depended on prostate α/β ratio and was highest with an α/β ratio = 1.5 Gy, where the additional TCP benefit of DIL boosting was least. Rectal NTCP increased with DIL boosting and was considered unacceptably high in 5 cases, which, when replanned with an emphasis on reducing maximum dose to 0.5 cm{sup 3} of rectum (Dmax{sub 0.5cc}), as well as meeting existing constraints, resulted in considerable rectal NTCP reductions. Conclusions: Boosting DILs in the context of SABR is technically feasible but should be approached with caution. If this therapy is adopted, strict rectal constraints are required including Dmax{sub 0.5cc}. If the α/β ratio of prostate cancer is 1.5 Gy or less, then high TCP and low NTCP can be achieved by prescribing SABR to the whole prostate, without the need for DIL boosting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗