Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

FPGA-Based Networked Phasemeter for a Heterodyne Interferometer

A document discusses a component of a laser metrology system designed to measure displacements along the line of sight with precision on the order of a tenth the diameter of an atom. This component, the phasemeter, measures the relative phase of two electrical signals and transfers that information to a computer. Because the metrology system measures the differences between two optical paths, the phasemeter has two inputs, called measure and reference. The reference signal is nominally a perfect square wave with a 50- percent duty cycle (though only rising edges are used). As the metrology system detects motion, the difference between the reference and measure signal phases is proportional to the displacement of the motion. The phasemeter, therefore, counts the elapsed time between rising edges in the two signals, and converts the time into an estimate of phase delay. The hardware consists of a circuit board that plugs into a COTS (commercial, off-the- shelf) Spartan-III FPGA (field-programmable gate array) evaluation board. It has two BNC inputs, (reference and measure), a CMOS logic chip to buffer the inputs, and an Ethernet jack for transmitting reduced-data to a PC. Two extra BNC connectors can be attached for future expandability, such as external synchronization. Each phasemeter handles one metrology channel. A bank of six phasemeters (and two zero-crossing detector cards) with an Ethernet switch can monitor the rigid body motion of an object. This device is smaller and cheaper than existing zero-crossing phasemeters. Also, because it uses Ethernet for communication with a computer, instead of a VME bridge, it is much easier to use. The phasemeter is a key part of the Precision Deployable Apertures and Structures strategic R&D effort to design large, deployable, segmented space telescopes.

Rao, Shanti↗

Diurnal Lightning Distributions as Observed by the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS)

Data obtained from the OTD (April 1995 to March 2000) and LIS (December 1997 to December 2005) satellites (70 and 35 degree inclination low earth orbits, respectively) are used to statistically determine the number of flashes in the diurnal cycle both as a function of local and universal time. Also included are global flash density maps. The data are further subdivided by season, continental versus oceanic, night time versus day time, northern versus southern hemisphere, and other regions of interest. The data include corrections for detection efficiency and instrument view time. The data are compared with both the "Carnegie Curve" and the diurnal global thunderstorm contributions from thunderday statistics from different continents, and are found to agree closely in phase and amplitude with the global thunderday statistics. The analysis also indicates that the southern hemisphere spring (September to November) has larger amplitude than the southern hemisphere fall (March to May). This may be due to differences in the contribution from the Brazilian rain forest during these periods. In general, as highlighted by a difference analysis, more lightning is observed in local springtime than the fall for continental locations, while oceanic regions display an opposite effect. For some areas of the world, the peak of diurnal curve appears to be shifted to later in the evening.

Bailey, Jeff C.↗

Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors

Superconducting-nanowire singlephoton detectors (SNSPDs) in which Nb(x)Ti(1-x)N (where x<1) films serve as the superconducting materials have shown promise as superior alternatives to previously developed SNSPDs in which NbN films serve as the superconducting materials. SNSPDs have potential utility in optical communications and quantum cryptography. Nb(x)Ti(1-x)N is a solid solution of NbN and TiN, and has many properties similar to those of NbN. It has been found to be generally easier to stabilize NbxTi1 xN in the high-superconducting-transitiontemperature phase than it is to so stabilize NbN. In addition, the resistivity and penetration depth of polycrystalline films of Nb(x)Ti(1-x)N have been found to be much smaller than those of films of NbN. These differences have been hypothesized to be attributable to better coupling at grain boundaries within Nb(x)Ti(1-x)N films.

Stem, Jeffrey A.↗

Data from the Mars Science Laboratory CheMin XRD/XRF Instrument

The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity uses a Co tube source and a CCD detector to acquire mineralogy from diffracted primary X-rays and chemical information from fluoresced X-rays. CheMin has been operating at the MSL Gale Crater field site since August 5, 2012 and has provided the first X-ray diffraction (XRD) analyses in situ on a body beyond Earth. Data from the first sample collected, the Rocknest eolian soil, identify a basaltic mineral suite, predominantly plagioclase (approx.An50), forsteritic olivine (approx.Fo58), augite and pigeonite, consistent with expectation that detrital grains on Mars would reflect widespread basaltic sources. Minor phases (each <2 wt% of the crystalline component) include sanidine, magnetite, quartz, anhydrite, hematite and ilmenite. Significantly, about a third of the sample is amorphous or poorly ordered in XRD. This amorphous component is attested to by a broad rise in background centered at approx.27deg 2(theta) (Co K(alpha)) and may include volcanic glass, impact glass, and poorly crystalline phases including iron oxyhydroxides; a rise at lower 2(theta) may indicate allophane or hisingerite. Constraints from phase chemistry of the crystalline components, compared with a Rocknest bulk composition from the APXS instrument on Curiosity, indicate that in sum the amorphous or poorly crystalline components are relatively Si, Al, Mg-poor and enriched in Ti, Cr, Fe, K, P, S, and Cl. All of the identified crystalline phases are volatile-free; H2O, SO2 and CO2 volatile releases from a split of this sample analyzed by the SAM instrument on Curiosity are associated with the amorphous or poorly ordered materials. The Rocknest eolian soil may be a mixture of local detritus, mostly crystalline, with a regional or global set of dominantly amorphous or poorly ordered components. The Rocknest sample was targeted by MSL for "first time analysis" to demonstrate that a loose deposit could be scooped, sieved to <150 microns, and delivered to instruments in the body of the rover. A drilled sample of sediment in outcrop is anticipated. At the time of writing this abstract, promising outcrops are in range and this talk will provide an update on data collected with the CheMin instrument.

Vaniman, David↗

In-Flight Calibration of ESA Hera’s Hyperscout-H Imager

ESA’s Hera space mission is on its way to the mission target, the binary asteroid (65803) Didymos. HyperScout-H, one of the instruments onboard Hera, is a hyperspectral imager operating in the visible and near-infrared regions between 0.65 and 0.95 μm. HyperScout-H will enable a detailed assessment of the composition of both objects, Didymos and its satellite Dimorphos, the characterization of space weathering effects, and the possible presence of exogenous material on their surfaces. To monitor instrument functionality, calibration exposures are acquired regularly. This article describes the in-flight calibrations carried out for HyperScout-H during the commissioning and cruise phases. Bias and dark exposures, as well as stellar field observations, were acquired several times after launch. We update the calibration data and monitor instrument performance in the space environment. In addition, images of Earth and Moon were acquired from distances of 1.5 × 10 6 to 2.0 × 10 6 km, and Mars and its satellite were imaged during the flyby. In five images, the surface of Mars fills the entire field of view, enabling cross-validation of HyperScout-H results with those reported by other Mars missions. We characterize the detector under in-flight operational conditions. The calibration data indicate that the bias pattern is stable, the dark current remains negligible for short exposures, and the detector response is highly linear. We quantify the field-of-view alignment and geometric distortion, and evaluate the point spread function based on the stellar field observations. Stellar observations and Mars swing-by data provide updated radiometric calibration constants, suggesting that in-flight conditions have slightly modified the detector’s spectral response. In-flight calibrations are essential to ensure data quality and reliability.

Image Processing↗

Analysis and testing of a new method for drop size and velocity measurements using laser light scatter interferometry

Drop size and velocity can be measured simultaneously using an optical system which is the same as a laser Doppler velocimeter except that three detectors are located at selected spacings behind the receiver aperture. Drops passing through the intersection of the two beams scatter light which produces an interferrence fringe pattern. The temporal frequency of the fringe pattern is the Doppler difference frequency which is linearly proportional to the drop velocity while the spatial frequency is linearly related to the drop diameter. The spacing of the fringes is also dependent upon the light wavelength, beam intersection angle, drop refractive index (unless reflected light is measured), and the location of the receiver. The theoretical analysis was verified, signal phase processing methods were evaluated, and the effects of signal quality upon the measurements were investigated.

Bachalo, W. D.↗

Imaging X-Ray Polarimetry Explorer Mission Attitude Determination and Control Concept

The goal of the Imaging X-Ray Polarimetry Explorer (IXPE) Mission is to expand understanding of high-energy astrophysical processes and sources, in support of NASA's first science objective in Astrophysics: "Discover how the universe works." X-ray polarimetry is the focus of the IXPE science mission. Polarimetry uniquely probes physical anisotropies-ordered magnetic fields, aspheric matter distributions, or general relativistic coupling to black-hole spin-that are not otherwise measurable. The IXPE Observatory consists of Spacecraft and Payload modules. The Payload includes three polarization sensitive, X-ray detector units (DU), each paired with its corresponding grazing incidence mirror module assemblies (MMA). A deployable boom provides the correct separation (focal length) between the DUs and MMAs. These Payload elements are supported by the IXPE Spacecraft. A star tracker is mounted directly with the deployed Payload to minimize alignment errors between the star tracker line of sight (LoS) and Payload LoS. Stringent pointing requirements coupled with a flexible structure and a non-collocated attitude sensor-actuator configuration requires a thorough analysis of control-structure interactions. A non-minimum phase notch filter supports robust control loop stability margins. This paper summarizes the IXPE mission science objectives and Observatory concepts, and then it describes IXPE attitude determination and control implementation. IXPE LoS pointing accuracy, control loop stability, and angular momentum management are discussed.

Attitude Determination and Contro↗

Adiabatic Gravitational Waveform Model for Compact Objects Undergoing Quasi-Circular Inspirals Into Rotating Massive Black Holes

We present bhpwave: a new python-based, open-source tool for generating the gravitational waveforms of stellar-mass compact objects undergoing quasicircular inspirals into rotating massive black holes. These binaries, known as extreme-mass-ratio inspirals (EMRIs), are exciting mHz gravitational wave sources for future space-based detectors such as the Laser Interferometer Space Antenna (LISA). Relativistic models of EMRI gravitational wave signals are necessary to unlock the full scientific potential of mHz detectors, yet few open-source EMRI waveform models exist. Thus we built bhpwave, which uses the adiabatic approximation from black hole perturbation theory to rapidly construct gravitational waveforms based on the leading-order inspiral dynamics of the binary. In this work, we present the theoretical and numerical foundations underpinning bhpwave. We also demonstrate how bhpwave can be used to assess the impact of EMRI modeling errors on LISA gravitational wave data analysis. In particular, we find that for retrograde orbits and slowly spinning black holes we can mismodel the gravitational wave phasing by as much as ∼10 radians without significantly biasing EMRI parameter estimation.

Zachary Nasipak↗

Human Exploration of the Moon and Mars: Space Radiation Data, Modeling and Instrumentation Needs

On January 14, 2004 President Bush announced the Vision for Space Exploration, a program for long-term human and robotic exploration of the solar system which will include a return of humans to the moon not later than 2020, followed by human missions to Mars. Since this announcement, NASA has been developing plans and mission architectures for these human missions as well as robotic precursor missions. Among the critical needs for research and development in support of this Vision are investigations on the ionizing radiation environment and development of instrumentation to guide NASA in managing the radiation exposure of the crew during the manned missions. For mission planning, models are needed for a reference worst-case solar energetic particle event and a reference worst-case galactic cosmic ray environment. During Lunar missions it will be necessary to carefully manage the radiation exposure of the crew in real time because of the variability of the radiation environment due to solar activity. In particular, prompt warnings will be needed when large solar energetic particle events occur. Accurate predictions will also be needed of the particle flux and flux history at the moon to support critical mission management decisions. A new generation of dosimeters and radiation monitors will also be needed to accompany the crew. These instruments must return data in real time so that they can be used in the critical decisions that must be made if a large solar energetic particle event occurs. This is especially true if it occurs during a lunar excursion. A substantial radiation exposure on extended lunar missions and Mars missions comes from galactic cosmic rays. This exposure must be mitigated by radiation shielding and other measures. During Mars missions the galactic cosmic ray exposure occurs primarily during the cruse phase between the Earth and Mars. This is especially true for opposition class missions. These missions would typically last -430 days with only 30-90 days on Mars. Solar energetic particle events are less of a concern on Mars because of its greater distance from the Sun (approximately 1.5 AU) and the partial protection afforded by its atmosphere (approximately 20 grams per square centimeter). The talk will describe the current plans for future human missions to Earth orbit, the Moon and Mars. The needs for data and models of the radiation environment and radiation detectors to support these missions will be discussed.

Adams, James H.↗

Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors

Superconducting-nanowire single-photon detectors (SNSPDs) in which Nb(x)Ti(1-x)N (where x<1) films serve as the superconducting materials have shown promise as superior alternatives to previously developed SNSPDs in which NbN films serve as the superconducting materials. SNSPDs have potential utility in optical communications and quantum cryptography. Nb(x)Ti(1-x)N is a solid solution of NbN and TiN, and has many properties similar to those of NbN. It has been found to be generally easier to stabilize Nb(x)Ti(1-x)N in the high-superconducting-transition temperature phase than it is to so stabilize NbN. In addition, the resistivity and penetration depth of polycrystalline films of Nb(x)Ti(1-x)N have been found to be much smaller than those of films of NbN. These differences have been hypothesized to be attributable to better coupling at grain boundaries within Nb(x)Ti(1-x)N films.

Stern, Jeffrey A.↗

NASA Tech Briefs, September 2009

opics covered include: Filtering Water by Use of Ultrasonically Vibrated Nanotubes; Computer Code for Nanostructure Simulation; Functionalizing CNTs for Making Epoxy/CNT Composites; Improvements in Production of Single-Walled Carbon Nanotubes; Progress Toward Sequestering Carbon Nanotubes in PmPV; Two-Stage Variable Sample-Rate Conversion System; Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas; Board Saver for Use with Developmental FPGAs; Circuit for Driving Piezoelectric Transducers; Digital Synchronizer without Metastability; Compact, Low-Overhead, MIL-STD-1553B Controller; Parallel-Processing CMOS Circuitry for M-QAM and 8PSK TCM; Differential InP HEMT MMIC Amplifiers Embedded in Waveguides; Improved Aerogel Vacuum Thermal Insulation; Fluoroester Co-Solvents for Low-Temperature Li+ Cells; Using Volcanic Ash to Remove Dissolved Uranium and Lead; High-Efficiency Artificial Photosynthesis Using a Novel Alkaline Membrane Cell; Silicon Wafer-Scale Substrate for Microshutters and Detector Arrays; Micro-Horn Arrays for Ultrasonic Impedance Matching; Improved Controller for a Three-Axis Piezoelectric Stage; Nano-Pervaporation Membrane with Heat Exchanger Generates Medical-Grade Water; Micro-Organ Devices; Nonlinear Thermal Compensators for WGM Resonators; Dynamic Self-Locking of an OEO Containing a VCSEL; Internal Water Vapor Photoacoustic Calibration; Mid-Infrared Reflectance Imaging of Thermal-Barrier Coatings; Improving the Visible and Infrared Contrast Ratio of Microshutter Arrays; Improved Scanners for Microscopic Hyperspectral Imaging; Rate-Compatible LDPC Codes with Linear Minimum Distance; PrimeSupplier Cross-Program Impact Analysis and Supplier Stability Indicator Simulation Model; Integrated Planning for Telepresence With Time Delays; Minimizing Input-to-Output Latency in Virtual Environment; Battery Cell Voltage Sensing and Balancing Using Addressable Transformers; Gaussian and Lognormal Models of Hurricane Gust Factors; Simulation of Attitude and Trajectory Dynamics and Control of Multiple Spacecraft; Integrated Modeling of Spacecraft Touch-and-Go Sampling; Spacecraft Station-Keeping Trajectory and Mission Design Tools; Efficient Model-Based Diagnosis Engine; and DSN Simulator.

Source record↗

Mobility Spectrometer Studies on Hydrazine and Ammonia Detection

An airborne vapor analyzer for detecting sub- to low- parts-per-million (ppm) hydrazine in the presence of higher concentration levels of ammonia has been under development for the Orion program. The detector is based on ambient pressure ionization and ion mobility characterization. The detector encompasses: 1) a membrane inlet to exclude particulate and aerosols from the analyzer inlet; 2) a method to separate hydrazine from ammonia which would otherwise lead to loss of calibration and quantitative accuracy for the hydrazine determination; and 3) response and quantitative determinations for both hydrazine and ammonia. Laboratory studies were made to explore some of these features including mobility measurements mindful of power, size, and weight issues. The study recommended the use of a mobility spectrometer of traditional design with a reagent gas and equipped with an inlet transfer line of bonded phase fused silica tube. The inlet transfer line provided gas phase separation of neutrals of ammonia from hydrazine at 50 C simplifying significantly the ionization chemistry that underlies response in a mobility spectrometer. Performance of the analyzer was acceptable between ranges of 30 to 80 C for both the pre-fractionation column and the drift tube. An inlet comprised of a combined membrane with valve-less injector allowed high speed quantitative determination of ammonia and hydrazine without cross reactivity from common metabolites such as alcohols, esters, and aldehydes. Preliminary test results and some of the design features are discussed.

Niu, William↗

The Role of NASA Engineering & Safety Center (NESC) in Advancing NASA’s Astrophysics Missions (Past, Present, and Future)

The NASA Engineering & Safety Center (NESC) was established in 2003 (after the Columbia accident) to provide an independent technical resource for the resolution of challenging technical problems (through the use of studies, analysis, tests, etc.) for NASA programs and projects. Since its inception, NESC has completed nearly 1000 technical assessments for NASA’s Human Exploration and Operation Mission Directorate (HEOMD), Science Mission Directorate (SMD), Space Technology Mission Directorate (STMD), and Aeronautics Research Mission Directorate (ARMD). Of the SMD related assessments, several were for the resolution of technical problems, analysis, or studies related to NASA’s astrophysics missions in various phases of the project from design to operation. Some of the recent examples of NESC technical support for NASA astrophysics missions have been for: Hubble Space Telescope (HST), Chandra X-ray Observatory (CXO), Fermi Gamma-ray Space Telescope, Kepler Space Telescope, Transiting Exoplanet Survey Satellite (TESS), James Webb Space Telescope (JWST), and Laser Interferometer Space Antenna (LISA). In this paper, we outline some of the technical challenges faced by these astrophysics missions and describe how NESC contributed to their resolution. The case studies cover a wide range of disciplines involving space telescopes, detectors, lasers, and attitude control systems. These efforts include innovative solutions for extending the life of the missions, technical resolution of challenging problems, strategies for risk mitigation, and failure investigations combined with lessons learned reports to advance discipline knowledge, enhance NASA capabilities, and avoid future problems.

NASA↗

Evidence for the siderophilic behavior of meteoritic bismuth

The microdistributions of Bi and Pb-208 in the Khohar L3 chondrite were determined in situ using radiography techniques based on particle track detectors. Strong (enrichment factors 10 to 100) localizations of Bi were found in association with kamacite; no enhancement of Bi or Pb was found in sulfides. High-magnification microprobe and reflected light observations strongly indicate that Bi actually resides in the kamacite, providing evidence for the siderophilic nature. The minor and major element chemistry of the metals in the sample was typical of chondrites of its type. The unusual Bi distribution in the Khohar chondrite suggests that it may have been exposed to high Bi partial pressures during slow cooling at kamacite-taenite phase separation in a volatile-rich region of a parent body, or that Bi may have been incorporated into previously cooled grains by mild reheating.

Woolum, D. S.↗

Optical investigation of Comet Halley

The physical properties of Comet P/Halley are being monitored from the ground using state of the art optical detectors. The long time base (1982-present) of the observations provides a unique record of the development of activity in a single comet. In addition, physical properties of other comets are measured to provide a reference against which Comet Halley may be compared. Results for the past year include: (1) publication of the first results on the surface brightness profiles of dust comets; (2) charge coupled device measurements of Comet Bowell show that the activity of comets can persist at least to heliocentric distances R = 13.6 AU; (3) a study of the back-scattering phase angle dependences of 5 comets (including Halley) shows evidence for small linear phase coefficients in each case; (4) temporal monitoring of P/Halley continues.

Jewitt, David↗

Determination of lunar ilmenite abundance from remotely sensed data

Of fundamental importance in the utilization of indigenous resources for a future permanently manned lunar base is the identification and mapping of the abundance distribution of the mineral ilmenite, which is currently considered the most readily identifiable and most easily accessible source of oxygen needed for human consumables and spacecraft propellant. Solid state detector array technology now permits the use of ground based multispectral remote sensing techniques to produce maps with better than one kilometer spatial resolution and uncertainties of about two weight-percent TiO2 abundance. An empirical relationship between the weight-percent abundance of titanium dioxide and the 400/560 nm spectral ratio measured in returned lunar samples was used. Because this abundance correlation is valid only for mature lunar mare regolith, the distribution of immature mafic minerals which were found to be correlated primarily with steep slopes exposing bedrock was qualitatively mapped. The first mapping phase focused on the entire lunar nearside at 5.3 km per pixel, and on experiments with more sensitive spectral ratios. Relative spectrophotometry was employed to aid in identifying wavelengths that provide greater spectral contrast. It was found that the 400/730 nm ratio improved the abundance sensitivity by 37 percent, while the 950/730 nm ratio improved mafic mineral contrast about 100 percent. The second mapping phase utilized a large experimental CCD at 280 m per pixel to map the high titanium regions identified in the phase one mapping. The high resolution maps provide data on the small scale (500 m) variations in abundance and their relationship to morphological units.

Larson, S. M.↗

Current system in an auroral substorm

An instrumented sounding rocket was launched at 0040 LT into the expansive phase of an auroral substorm on March 16, 1973, from Poker Flat, Alaska. This report describes coordinated measurements of electric field, magnetic field, and energetic electrons. By comparing the observed magnetic field with that predicted by model currents, a current system, which includes field-aligned currents, is deduced. The model indicates three currents: a southward current, a westward current, and two field-aligned currents. A southward electric field of 60 mV/m identifies the southward current as a Pedersen current and the westward current as a Hall current. The field-aligned current measured from particle detectors shows a structure similar to that in the magnetic model. The total field-aligned electron current measured by particle detectors agrees within 10% of the current model.

Kintner, P. M.↗

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗