Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Observing Mergers of Non-Spinning Black-Hole Binaries

Advances in the field of numerical relativity now make it possible to calculate the final, most powerful merger phase of binary black-hole coalescence for generic binaries. The state of the art has advanced well beyond the equal-mass case into the unequal-mass and spinning regions of parameter space. We present a study of the nonspinning portion of parameter space, primarily using an analytic waveform model tuned to available numerical data, with an emphasis on observational implications. We investigate the impact of varied m8BS ratio on merger signal-to-noise ratios (SNR~) for several detectors, and compare our results with expectations from the test-mass limit. We note a striking similarity of the waveform phasing of the merger waveform across the available mass ratios. Motivated by this, we calculate the match between our equal-mass and 4:1 mass-ratio waveforms during the merger as a function of location on the source sky, using a new formalism for the match that accounts for higher harmonics. This is an indicator of the amount of degeneracy in mass ratio for mergers of moderate mass ratio systems.

McWilliams, Sean T.↗

Evaluation of planar silicon pixel sensors with the RD53A readout chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Large Hadron Collider at CERN will undergo an upgrade inorder to increase its luminosity to7.5 × 10$^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosityduring this High-Luminosity running phase, starting around 2029,means a higher rate of proton-proton interactions, hence a largerionizing dose and particle fluence for the detectors. The currenttracking system of the CMS experiment will be fully replaced inorder to cope with the new operating conditions. Prototype planarpixel sensors for the CMS Inner Tracker with square50 μm × 50 μm and rectangular100 μm × 25 μm pixels read out by theRD53A chip were characterized in the lab and at the DESY-II testbeamfacility in order to identify designs that meet the requirements ofCMS during the High-Luminosity running phase. A spatial resolutionof approximately 3.4 μm (2 μm) is obtained using themodules with 50 μm × 50 μm(100 μm × 25 μm) pixels at the optimalangle of incidence before irradiation. After irradiation to a 1 MeVneutron equivalent fluence ofΦ$_{eq}$ = 5.3 × 10$^{15}$ cm$^{-2}$, a resolution of9.4 μm is achieved at a bias voltage of 800 V using a modulewith 50 μm × 50 μm pixel size. All modulesretain a hit efficiency in excess of 99% after irradiation tofluences up to 2.1 × 10$^{16}$ cm$^{-2}$. Further studies ofthe electrical properties of the modules, especially crosstalk, arealso presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing ITER motional Stark effect line shift (MSE-LS) spectrometers

As a part of ITER beam aided diagnostics, the design of Motional Stark Effect (MSE) diagnostic observing the emission from the Balmer-α line is underway. The physics of Stark splitting shows that the Stark manifold is polarization dependent, and the energy splitting results in a line shift proportional to the electric field. Due to the challenges of maintaining the calibration of the plasma facing mirrors in ITER, the conventional MSE polarimetry measurement technique is replaced with a spectral approach that is deemed more favorable in the ITER environment. The MSE line shift (LS) diagnostic is designed to quantify the Lorentz electric field magnitude by measuring the Stark manifold using visible spectroscopy. In the presence of large magnetic fields and high energy heating beams of 1 MeV, the expected Stark splitting is much larger than in typical devices. The MSE-LS design has unique challenges requiring careful consideration and modeling of its viewing geometry and photon budget. The MSE-LS approach on ITER is promising but has stringent demands on the allowable errors for the statistical and systematic fitting uncertainties. In this study, a full system model and numerical simulations of data for each sightline are completed. For a range of optical transmission fractions, photon noise analysis is conducted to determine the statistical uncertainties. This provides guidance on the spectrometer throughput, dispersion at the detector, optics, and other design choices. A conceptual design of a high throughput spectrometer with a volume phase transmission grating is presented.

Instruments & Instrumentation↗

Swept group delay measurement

Direct recording of group delay measurements on a system under temperature and stress tests employs modulated carrier frequency sweep over an S or X band. Reference path and test paths to separate detectors utilize a power divider e.g., a directional coupler or a hybrid T junction. An initially balanced phase comparator is swept in frequency by modulated carrier over the band of interest for different conditions of temperature and/or mechanical stress to obtain characteristic group delay curves.

Trowbridge, D. L.↗

Measurement of radial and latitudinal gradients of cosmic ray intensity during the decreasing phase of sunspot cycle 21

The cosmic ray radial and latitudinal gradients during the 1981-1984 decreasing phase of sunspot cycle 21 are investigated based on data from Voyagers 1 and 2, with a detector threshold of not less than 70 MeV/nuc, and IMP-8, with a detector threshold of not less than 35 MeV/nuc. During the interval, the heliolongitudinal separation between the Voyager spacecraft changed from about 4 to 26 deg, and comparison of the 26-day means of the cosmic ray intensities obtained show that the data is consistent on the average with a long-term zero latitudinal gradient. Comparison at 1 AU of Voyager and IMP-8 data illustrate that the radial gradient decreased over this period at the rate of about 0.4 percent per AU per year, reaching a value of about 2.0 percent/AU between 16 and 22 AU, and a value of about 0.6 percent/AU between 16 and 22 AU, a pattern which would locate both Voyagers during 1977 outside the principal cosmic ray modulation at solar minimum within 22 AU.

Venkatesan, D.↗

Purification and Crystal Growth of Lead Iodide by Physical Vapor Transport Method

Lead iodide (PbI2) is a layered compound semiconductor being developed as room temperature x- and gamma-ray detector. Compared to the more studied material, mercuric iodide, PbI2 has a higher melting temperature and no phase transition until liquid phase which are indications of better mechanical properties. In this study, the source material was purified by the zone-refining process, and the purest section was extracted from center of the the zone-refined ingot to be grown by physical vapor transport (PVT) method. The zone-refined material and as-grown crystals were characterized by optical microscopy and differential scanning calorimetry (DSC) to reveal the surface morphology, purity and stoichiometry. The results shows that both materials are near-stoichiometric composition, with the purity of the as-grown crystals higher than zone-refined materials. The resistivity of the as-grown crystal (10" Omega-cm) was derived from current-voltage (I-V) measurement, and is 10 times higher than the zone-refined materials. Detail results will be presented and discussed.

Wright, G. W.↗

Overview of the Design, Fabrication and Performance Requirements of Micro-Spec, an Integrated Submillimeter Spectrometer

Micro-Spec is a compact submillimeter (350-700 GHz) spectrometer which uses low loss superconducting niobium microstrip transmission lines and a single-crystal silicon dielectric to integrate all of the components of a grating-analog spectrometer onto a single chip. Here we present details of the fabrication and design of a prototype Micro-Spec spectrometer with resolution, R64, where we use a high-yield single-flip wafer bonding process to realize instrument components on a 0.45 m single-crystal silicon dielectric. We discuss some of the electromagnetic design concerns (such as loss, stray-light, cross-talk, and fabrication tolerances) for each of the spectrometer components and their integration into the instrument as a whole. These components include a slot antenna with a silicon lens for optical coupling, a phase delay transmission line network, parallel plate waveguide interference region, and aluminum microstrip transmission line kinetic inductance detectors with extremely low cross-talk and immunity to stray light. We have demonstrated this prototype spectrometer with design resolution of R64. Given the optical performance of this prototype, we will also discuss the extension of this design to higher resolutions suitable for balloon-flight.

spectrometer↗

Photoproduction of Cascade Baryons Using the GlueX Detector at Jefferson Laboratory

Multi-strange baryons have played an important role in understanding the strong interaction. Despite their importance to advancing quantum chromodynamics (QCD), little is known about such hyperons due to the lack of a strange probe. Almost all knowledge of Cascade baryons today stems from kaon-nucleon interactions in bubble chamber experiments performed in the 1960s and 1970s. The 1980s saw advancement in electronics and computational resources allowing for higher statistic experiments such as the MultiParticle Spectrometer (MPS) at Brookhaven National Laboratory. From these previous experiments, the octet and decuplet ground states, Xi(1320) and Xi(1530) respectively, were well established with known properties and four excited states were well established. This research uses the GlueX experiment at Jefferson Laboratory to extend photoproduction cross section measurements for Xi(1320)- to higher beam energies to further understand the production mechanism, as well as to search for the first excited Cascade resonance observation in photoproduction through the decay Xi-* -> K-Lambda. The GlueX Spectrometer is a nearly hermetic detector used to study exclusive photoproduction reactions with photon beam energies up to 12 GeV. The first phase of GlueX running has recently been completed. Preliminary results for the total cross section and differential cross sections in terms of momentum transfer -t are shown within. Additionally, the first observation of an excited Cascade baryon, in particular Xi(1820)-, is shown.

Ernst, Ashley↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Energetic particle flux experiment (IMP-F and G)

The technical aspects of the University of California IMP-F experiment aboard the Explorer-34 and the University of California IMP-G (S1) and (S2) experiments aboard the Explorer-41. The experiment detectors and electronics are discussed for each experiment as well as the fabrication, preflight and post-flight history. A description of the ground support equipment is also given for each experiment. These three experiments were essentially all different. The IMP-G experiment was essentially the IMP-F experiment with the addition of four Geiger-Mueller detectors. The IMP-G (S-2) was a supplementary experiment and differed completely from the IMP-F and IMP-G experiments. It was concluded that the ground support equipment approach used for the IMP-F and IMP-G experiments where emphasis was placed on a thorough exercise and monitoring of the experiment operation during various testing phases provided a high degree of confidence and reliability in these experiments. No known electronic failures have occurred during the spacecraft lifetime although some detector problems were experienced.

Anderson, K. A.↗

Containerization of Phase-2 Tracker Data Acquisition and Control Framework

The CMS Experiment has started an extensive upgrade program in the context of the High-Luminosity phase of the LHC (Phase-2). In order to cope with the highly demanding High-Luminosity conditions, CMS will need a completely new inner and outer tracking detectors. On top of R&D development, a Data AcQuisition (DAQ) software is being developed along with different applications to control, monitor and validate the newly produced modules of the future tracker. As more and more developers are getting involved to maintain all those codes, an environment where software and applications can work independently of the host machine operating system is crucial. The Phase-2 Tracker group decided to make use of Docker as containerization solution for its framework. This poster describes the containerization of DAQ software/applications utilized to test and validate the Tracker modules. This includes continuous integration and continuous deployment (so-called CI/CD) and running GUI applications inside containers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quality Control of Silicon Sensor Modules for Particle Detectors

The High-Luminosity Large Hadron Collider (HL-LHC) will produce a higher rate of particle collisions than the current Large Hadron Collider (LHC), requiring important upgrades to the Compact Muon Solenoid (CMS) to handle an increased amount of data. An important upgrade is the Phase-2 Outer Tracker Upgrade, which consists of 13,000 silicon sensor modules made of two parallel silicon sensors and readout electronics. These modules undergo careful quality control checks both during and after module assembly to ensure precise and reliable detector performance. This project focuses on precision testing for quality control of silicon sensor modules at Fermilab. Hands-on work includes visual inspection, current-voltage testing, module testing, and ultraviolet (UV) light exposure of modules showing abnormal current-voltage behavior. The ultraviolet exposure process improves the abnormal sensor readout data by placing the selected sensor side of the module directly under the UV light inside a controlled box. In addition to laboratory testing and ultraviolet experiments, I developed a Python-based data tool that connects to a module database and allows selected testing conditions and module information to be retrieved and displayed efficiently. These different testing procedures, experimental processes, and computational tools support the broader goal of identifying module issues and improving modules that will be used in the CMS Outer Tracker Phase-2 Upgrade.

Siddiqui, Hooriya [DuPage Coll.] (ORCID:0009000151↗

Quality Control of Silicon Sensor Modules for Particle Detectors

The High-Luminosity Large Hadron Collider (HL-LHC) will produce a higher rate of particle collisions than the current Large Hadron Collider (LHC), requiring significant upgrades to the Compact Muon Solenoid (CMS) to handle the increased amount of data. An important upgrade is the Phase-2 Outer Tracker Upgrade, which consists of 13,000 silicon sensor modules made of two parallel silicon sensors and readout electronics. These modules undergo careful quality control checks both during and after module assembly to ensure precise and reliable detector performance. This project focuses on precision testing for quality control of silicon sensor modules at Fermilab. Hands-on work includes visual inspection, current-voltage testing, module testing, and ultraviolet (UV) light exposure of modules showing abnormal current-voltage behavior. The ultraviolet exposure process improves the abnormal sensor readout data by placing the selected sensor side of the module directly under the UV light inside a controlled box. In addition to laboratory testing and ultraviolet experiments, I developed a Python-based data tool that connects to a module database and allows selected testing conditions and module information to be retrieved and displayed efficiently. These different testing procedures, experimental processes, and computational tools support the broader goal of identifying module issues and improving modules that will be used in the CMS Outer Tracker Phase-2 Upgrade.

Siddiqui, Hooriya [DuPage Coll.; Fermilab] (ORCID:↗

Development of a High-Resolution, Single-Photon X-Ray Detector

Research on the development of a low-temperature, magnetic bolometer for x-ray detection is reported. The principal accomplishments during the first phase of this research are as follows. (1) We have constructed SQUID magnetometers and detected both 122 keV and 6 keV x-rays in relatively larger metallic samples with high quantum efficiency. (2) The magnetic properties of a metal sample with localized paramagnetic spins have been measured and found to agree with theoretical expectations. (3) The size of the magnetic response of the sample to x-rays is in agreement with predictions based on the properties of the sample and sensitivity of the magnetometer, supporting the prediction that a resolution of 1 eV at 10 keV should be achievable.

Seidel, George M.↗

In-Pixel Readout IC with compact in-pixel ADC for Pixel detectors at HL LHC

The prototype Smart Pixel concept test chip (SP28), designed in a CMOS 28 nm bulk process, is a proof of concept readout integrated circuit (ROIC) designed for a future Phase III High Luminosity upgrade of the Large Hadron Collider. It employs a synchronous analog to digital converter (ADC) for the front-end design, with signal processing and data conversion within a single bunch crossing of 25 ns. It is therefore capable of accurately detecting hits occurring in consecutive bunch crossings, without off-time registration of events and pileup insensitivity, making it particularly suitable for the inner most layers of the vertex detector. The ROIC consists of a matrix of 32 × 16 pixels, each 25 × 25 µm 2 in size. Each pixel contains a charge sensitive preamplifer with leakage current compensation, three auto-zero comparators for a 2-bit fash-type ADC. The total power consumption is approximately 5 µW per pixel. The measured noise at the output of all the hit comparators across the ROIC is < 90 e- with threshold dispersion < 45 e-RMS, which allows an in-time threshold setting of ≈ 475 e-.

Parpillon, Benjamin↗

An Overview of the Mid-Infrared Spectro-Interferometer MATISSE: Science, Concept, and Current Status

MATISSE is the second-generation mid-infrared spectrograph and imager for the Very Large Telescope Interferometer (VLTI) at Paranal. This new interferometric instrument will allow significant advances by opening new avenues in various fundamental research fields: studying the planet-forming region of disks around young stellar objects, understanding the surface structures and mass loss phenomena affecting evolved stars, and probing the environments of black holes in active galactic nuclei. As a first breakthrough, MATISSE will enlarge the spectral domain of current optical interferometers by offering the L and M bands in addition to the N band. This will open a wide wavelength domain, ranging from 2.8 to 13 microns, exploring angular scales as small as 3 mas (L band) 10 mas (N band). As a second breakthrough, MATISSE will allow mid-infrared imaging - closure-phase aperture-synthesis imaging - with up to four Unit Telescopes (UT) or Auxiliary Telescopes (AT) of the VLTI. Moreover, MATISSE will offer a spectral resolution range from R approx. 30 to R approx. 5000. Here, we present one of the main science objectives, the study of protoplanetary disks, that has driven the instrument design and motivated several VLTI upgrades (GRA4MAT and NAOMI). We introduce the physical concept of MATISSE including a description of the signal on the detectors and an evaluation of the expected performances. We also discuss the current status of the MATISSE instrument, which is entering its testing phase, and the foreseen schedule for the next two years that will lead to the first light at Paranal.

interferometric instrument↗

Transferring orbital angular momentum to an electron beam reveals toroidal and chiral order

Orbital angular momentum (OAM) and torque transfer play central roles in a wide range of magnetic textures and devices including skyrmions and spin-torque electronics. Analogous topological structures are now also being explored in ferroelectrics, including polarization vortex arrays in ferroelectric/dielectric superlattices. Unlike magnetic toroidal order, electric toroidal order does not couple directly to linear external fields. Instead, we find that the presence of an electric toroidal moment in a ferrorotational phase transfers measurable torque and OAM to a localized electron beam in the ballistic limit. We record these torque transfers from a high-energy electron beam using a momentum-resolved detector. This approach provides a high-sensitivity method to detect polarization fields and their more complex order parameters and topologies. In addition to toroidal order, we also demonstrate high-precision measurements of vorticity and chirality for polar vortexlike phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗