Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Sierra/SolidMechanics 5.10 Example Problems Manual

Presented in this document are tests that exist in the Sierra / SolidMechanics example problem suite, which is a subset of the Sierra / SM regression and performance test suite. These examples showcase common and advanced code capabilities. A wide variety of other regression and verification tests exist in the Sierra / SM test suite that are not included in this manual.

42 ENGINEERING↗

DESTRUCTION OF TETRAPHENYLBORATE IN TANK 48H USING WET AIR OXIDATION BATCH BENCH SCALE AUTOCLAVE TESTING WITH ACTUAL RADIOACTIVE TANK 48H WASTE

Wet Air Oxidation (WAO) is one of the two technologies being considered for the destruction of Tetraphenylborate (TPB) in Tank 48H. Batch bench-scale autoclave testing with radioactive (actual) Tank 48H waste is among the tests required in the WAO Technology Maturation Plan. The goal of the autoclave testing is to validate that the simulant being used for extensive WAO vendor testing adequately represents the Tank 48H waste. The test objective was to demonstrate comparable test results when running simulated waste and real waste under similar test conditions. Specifically: (1) Confirm the TPB destruction efficiency and rate (same reaction times) obtained from comparable simulant tests, (2) Determine the destruction efficiency of other organics including biphenyl, (3) Identify and quantify the reaction byproducts, and (4) Determine off-gas composition. Batch bench-scale stirred autoclave tests were conducted with simulated and actual Tank 48H wastes at SRNL. Experimental conditions were chosen based on continuous-flow pilot-scale simulant testing performed at Siemens Water Technologies Corporation (SWT) in Rothschild, Wisconsin. The following items were demonstrated as a result of this testing. (1) Tetraphenylborate was destroyed to below detection limits during the 1-hour reaction time at 280 C. Destruction efficiency of TPB was > 99.997%. (2) Other organics (TPB associated compounds), except biphenyl, were destroyed to below their respective detection limits. Biphenyl was partially destroyed in the process, mainly due to its propensity to reside in the vapor phase during the WAO reaction. Biphenyl is expected to be removed in the gas phase during the actual process, which is a continuous-flow system. (3) Reaction byproducts, remnants of MST, and the PUREX sludge, were characterized in this work. Radioactive species, such as Pu, Sr-90 and Cs-137 were quantified in the filtrate and slurry samples. Notably, Cs-137, boron and potassium were shown as soluble as a result of the WAO reaction. (4) Off-gas composition was measured in the resulting gas phase from the reaction. Benzene and hydrogen were formed during the reaction, but they were reasonably low in the off-gas at 0.096 and 0.0063 vol% respectively. Considering the consistency in replicating similar test results with simulated waste and Tank 48H waste under similar test conditions, the results confirm the validity of the simulant for other WAO test conditions.

08 HYDROGEN↗

Validation and Verification of Python based Neutron Spectrum Unfolding Software

To validate and verify the python-based code (PySL), designed to replicate the programs used by STAYSL for Beam Correction Factor (BCF) and Self-Shielding Factor (SHIELD), a series of tests were performed. To test BCF a python script was written to generate a random flux history file and both versions of the code processed the data. The test verified matching values up to at least one decimal place, approximately 10,000 tests where run and each one passed. Isotopes began to fail the tests once neutron saturation was reached. To verify this the total time of exposure was varied the isotopes that failed were compared to a list of their half-lives. The test process for SHIELD was very similar but, in this case, the code began by producing an input file with varying thickness and device type/environment for the SHIELD input. The failure condition for this test was if any of the data points for an isotope had a difference above 3%. Approximately 40 of these tests were run and there were only 3 isotopes that had reoccurring failures but only 2% of their points were above the 3% difference. A visual comparison was conducted by plotting the results from both programs. Although the test failed, the differences between their values were minuscule, and the self-shielding factor’s shape was preserved when plotted. Next steps for this project will be validating and verifying the python-based SigPhi code and then reproducing and testing the least squares unfolding performed by STAYSL.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Report for the Testing of the Y-12 Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor (IER-443)

This report documents the experimental conditions and final results for the performance testing of the Y-12 Criticality Accident Alarm System (CAAS) detectors at the Godiva IV Burst Reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The testing followed a previously issued test plan and was conducted during the week of July 17, 2017, with completion on Thursday July 20. The test subjected CAAS detectors supplied by Y-12 to very intense and short duration mixed neutron and gamma radiation fields to establish compliance to maximum radiation and minimum pulse width requirements. ANSI/ANS- 8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates provided by each burst during the test exceeded those requirements. The CAAS detectors all provided an immediate alarm signal and remained operable after the bursts establishing compliance to the requirements and fitness for re-deployment at Y-12.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Testing and certification of the SAVY 4000 nuclear material container for DOT Type A liquid transport - 15636

Los Alamos National Laboratory has contracted with Nuclear Filter Technology, Inc. to perform testing and certification of the SAVY 4000 container for DOT Type A liquid transport. The container was originally designed to meet DOE M441.1-1 requirements for safe storage of nuclear material, and it is currently being used for storage at Los Alamos National Laboratory, Livermore National Laboratory, Idaho National Laboratory and Nevada National Security Site. The SAVY 4000 container is manufactured from 316L stainless steel in a range of sizes from 1 quart to 10 gallon capacity, it can be opened and closed easily by hand, it is sealed with a Viton{sup R} O-Ring, and the filter retains particulates and resists liquid water entry while allowing hydrogen gas to escape. Finite element analysis has been used to guide the development of a testing regime that includes a 30 foot drop, bar penetration, vibration, water spray and stacking for the 5 quart capacity container. The results of the tests will be compared with the finite element analysis to validate the model. The validated model is being used to extend the Type A certification to the other container sizes. This poster will describe the results of the Type A liquid testing, the finite element analysis, and the benefits of broadening the use and versatility of the container. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Performance Evaluation of Walls with Gas Filled Panel Insulation

Gas filled insulation panels (GFP) are very light weight and compact (when uninflated) advanced insulation products. GFPs consist of multiple layers of thin, low emittance (low-e) metalized aluminum. When expanded, the internal, low-e aluminum layers form a honeycomb structure. These baffled polymer chambers are enveloped by a sealed barrier and filled with either air or a low-conductivity gas. The sealed exterior aluminum foil barrier films provide thermal resistance, flammability protection, and properties to contain air or a low conductivity inert gas. This product was initially developed with a grant from the U.S. Department of Energy. The unexpanded product is nearly flat for easy storage and transport. Therefore, transportation volume and weight of the GFP to fill unit volume of wall cavity is much smaller compared to that of other conventional insulation products. This feature makes this product appealing to use at Army Contingency Basing, when transportation cost is significant compared to the cost of materials. The objective of this study is to evaluate thermal performance of walls, similar to those used at typical Barracks Hut (B-Hut) hard shelters, when GFPs are used in the wall cavities. Oak Ridge National Laboratory (ORNL) tested performance of the wall in the rotatable guarded hotbox (RGHB) according to the ASTM C 1363 standard test method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FeCoSiBNbCu bulk metallic glass with large compressive deformability studied by time-resolved synchrotron X-ray diffraction

By adding 0.5 at. % Cu to the strong but brittle [(Fe{sub 0.5}Co{sub 0.5}){sub 0.75}Si{sub 0.05}B{sub 0.20}]{sub 96}Nb{sub 4} bulk metallic glass, fully amorphous rods with diameters up to 2 mm were obtained. The monolithic samples with 1 mm diameter revealed a fracture strain of 3.80% and a maximum stress of 4143 MPa upon compression, together with a slight work-hardening behavior. SEM micrographs of fractured samples did neither reveal any shear bands on the lateral surface nor the typical vein patterns which characterize ductile fracture. However, some layers appear to have flowed and this phenomenon took place before the brittle final fracture. An estimate of the temperature rise ΔT in the shear plane gives 1039 K, which is large enough to melt a layer of 120 nm. The overall performance and the macroscopic plastic strain depend on the interaction between cleavage-like and viscous flow-like features. Mechanical tests performed in-situ under synchrotron radiation allowed the calculation of the strain tensor components, using the reciprocal-space data and analyzing the shift of the first (the main) and the second broad peak positions in the X-ray diffraction patterns. The results revealed that each atomic shell may have a different stiffness, which may explain the macroscopic compressive plastic deformation. Also, there were no signs of (nano) crystallization induced by the applied stress, but the samples preserve a monolithic amorphous structure until catastrophic failure occurs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Model for determining rupture area in Zircaloy cladding under LOCA conditions

The dispersal of nuclear fuel through a cladding rupture opening during a transient event is the primary safety concern preventing the United States nuclear industry from extending burnup beyond a peak rod average burnup of 62 GWd/tU. The majority of research thus far has prioritized understanding, or at a minimum prioritized quantifying, fuel fragmentation and pulverization as a function of burnup and to a lesser extent onset temperature. Early high burnup loss-of-coolant accident tests performed at the Halden Boiling Water Reactor evaluated the impact of relocation on cladding temperature, whereas historical and recent cladding burst tests focused primarily on generating data related to cladding balloon and burst timing. However, very little effort has been put forth to develop a relationship for determining the rupture opening dimensions for Zircaloy cladding tubes bursting during a simulated light water reactor loss-of-coolant accident. This is significant because high burnup loss-of-coolant accident data suggest dispersal could be limited by the size of the rupture opening or rupture dimensions, thereby minimizing the safety concern. Therefore, the purpose of this research is to build a database composed of all simulated loss-of-coolant accident data to develop an empirical model that conservatively captures the rupture opening dimensions and translates those dimensions to rupture area. Analysis of the experimental data indicates the rupture dimensions are strongly correlated to the peak balloon strain. This relationship is leveraged to develop a rupture length empirical correlation as a function of peak balloon strain and a rupture width empirical correlation as a function of rupture length. Outliers in the experimental data are identified and discussed. Finally, the rupture opening empirical model is presented in such a way for general implementation into high fidelity fuel performance codes or fuel performance codes used for safety analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

De-pollution efficacy of photocatalytic roofing granules

Photocatalytic building surfaces can harness sunlight to reduce urban air pollution. The NO x abatement capacity of TiO 2 -coated granules used in roofing products was evaluated for commercial product development. A laboratory test chamber and ancillary setup were built following conditions prescribed by ISO Standard 22197-1. It was validated by exposing reference P25-coated aluminum plates to a 3 L min -1 air flow enriched in 1 ppm NO under UVA irradiation (360 nm, 11.5 W m -2 ). We characterized prototype granule-surfaced asphalt shingles and loose granules prepared with different TiO 2 loadings and post-treatment formulations. Tests performed at surface temperatures of 25 and 60 °C showed that NO x abatement was more effective at the higher temperature. Preliminary tests explored the use of 1 ppm NO 2 and of 1 ppm and 0.3 ppm NO/NO 2 mixtures. Specimens were aged in a laboratory accelerated weathering apparatus, and by exposure to the outdoor environment over periods that included dry and rainy seasons. Laboratory aging led to higher NO removal and NO 2 formation rates, and the same catalyst activation was observed after field exposure with frequent precipitation. However, exposure during the dry season reduced the performance. This inactivation was mitigated by cleaning the surface of field-exposed specimens. Doubling the TiO 2 loading led to a 50–150% increase in NO removal and NO x deposition rates. Finally, application of different post-treatment coatings decreased NO removal rates (21–35%) and NO x deposition rates (26–74%) with respect to untreated granules. The mass balance of nitrogenated species was assessed by extracting granules after UV exposure in a 1 ppm NO-enriched atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Production and Quality Assurance of Mu2e Calorimeter CsI Crystals

The Mu2e calorimeter is composed of 1348 CsI crystal arranged in two annular disk. Starting from March 2017 the characterization on the crystals has started. After a visual inspection and the mechanical test performed with a CMM, the optical properties and the irradiation damages are measured at the same time in Caltech and Fermilab. All the crystals from Siccas have already been tested while the expected end of Saint Gobain production is October 2019. The crystals from both vendor show excellent performance in agreement with the experiment specifications

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lightweight runtime checking of C programs with RTC

The C Programming Language is known for being an efficient language that can be compiled on almost any architecture and operating system. However the absence of dynamic safety checks and a relatively weak type system allows programmer oversights that are hard to spot. In this paper, we present RTC, a runtime monitoring tool that instruments unsafe code and monitors the program execution. RTC is built on top of the ROSE compiler infrastructure. RTC finds memory bugs and arithmetic overflows and underflows, and run-time type violations. Most of the instrumentations are directly added to the source file and only require a minimal runtime system. As a result, the instrumented code remains portable. In tests against known error detection benchmarks, RTC found 98% of all memory related bugs and had zero false positives. Finally, in performance tests conducted with well known algorithms, such as binary search and MD5, we determined that our tool has an average run-time overhead rate of 9.7× and memory overhead rate of 3.5×.

97 MATHEMATICS AND COMPUTING↗

Solid oxide electrolysis cell and stack testing best practices

Solid oxide electrolyzer (SOE) technology is an emerging method for hydrogen production, noted for its superior electrical efficiency. Despite the significant progress made in recent years, the broad development of SOE technology is often constrained by the necessary and extensive "skill of the craft" required to successfully test simple single cell test articles. This may be linked to the dearth of practical and pragmatic guidance within the literature for safe, reliable, and performant test equipment and test procedures. Researchers at the Idaho National Laboratory (INL) have been actively testing SOEs ranging from button cells to stacks up to 500 kW, in collaboration with industry and other national laboratories. Based on operational experience, INL has developed system design procedures that ensure safe and reliable operation of SOE systems with the level of support required for each test. This paper presents key aspects of SOE stack and system testing, including safe design procedures, balance of plant components design, and specific implementations at INL. Practical design details of reactants, heat, and power management are presented along with lessons learned from the SOE test facility operations at INL.

08 HYDROGEN↗

Development and Evaluation of a Sandia Cooler-based Refrigerator Condenser

This report describes the first design of a refrigerator condenser using the Sandia Cooler, i.e. air - bearing supported rotating heat - sink impeller. The project included baseline performance testing of a residential refrigerator, analysis and design development of a Sandia Cooler condenser assembly including a spiral channel baseplate, and performance measurement and validation of this condenser system as incorporated into the residential refrigerator. Comparable performance was achieved in a 60% smaller volume package. The improved modeling parameters can now be used to guide more optimized designs and more accurately predict performance.

42 ENGINEERING↗

NMSBA High Frequency Modal Analysis of a Solid Metal Cylinder

This memo documents the results and methodology of the high-frequency modal test performed on a solid metal cylinder, provided by Vibrant Corporation, in September 2014 at Sandia National Laboratories. The purpose of this test was to measure mode shapes of the unit (torsion, axial, and bending) as high in frequency as achievable with a Polytec PSV-400 scanning laser Doppler vibrometer.

42 ENGINEERING↗

Distributed Ledger Technology Preliminary Performance Assessment for Applications in Utilities Operational Technology

This paper provides descriptions of the key components of different distributed ledger technology platforms. Distributed ledger technology (DLT) allows for distribution of databases among different organizations and devices. The platforms use cryptographically linked “blocks” to store and verify transactional information between these organizations. DLT increases data security, data integrity, trust among its participants. Different organizations are looking to deploy this distributed and decentralized approach to avoid the single-point-of-failure vulnerabilities associated with centralized data repositories. In this study we examine twelve different DLT platforms. There is agreement within the community that of all the platforms considered here, Hyperledger and Ethereum are the most mature when it comes to privacy and permissions. These DLT platforms are being used for applications such as transactive energy, health care, and the food and goods supply chain. However, further development is required to realize the full promise of DLT. Our assessment includes a general description of each DLT and its key characteristics. Such characteristics include consensus protocol and cryptography used, public vs. private, and permissioned or permissionless. The selection and implementation of a DLT architecture depends heavily on the use case and performance requirements. During this research we found key parameters to measure performance and existing tools for assessment. Four different parameters were identified 1) consensus, 2) throughput, 3) latency, and 4) scalability. The architectures of Hyperledger Caliper and Blockbench are described as different performance assessment frameworks. From this preliminary study it is evident that there are dissimilarities on the performance assessments methods developers and users are characterizing DLT architectures. The purpose of this paper is to identify key parameters to test performance, tools that are being used and provide information on results from previous studies.

97 MATHEMATICS AND COMPUTING↗

Mu2e Tracker's Gas Connection

This report is a resume of the activities in which I was involved during my internship at Fermilab Particle Physics and Accelerator Laboratory in Batavia. The experiment at whom my work is connected is the Mu2e experiment, in particular I worked in the Tracker’s group. The main task of my training program was to design a gas service connection that take place in a small volume located between the Tracker and the Calorimeter (two main elements that constitute the detector). During the initial phase I was lightly trained about the experiment and its general design, then I was supervised on my specific task. All the work aimed to reach a design solution that could meet all the BCs, in this view, a reasonable solution was prototyped and tested. The tests performed at Lab 3 were another fundamental aspect of my experience at Fermilab closing the circle of studying, modelling, machining and testing. I want to thank primarily Aseet Mukherjee and Mete Yucel that were my supervisors, they constantly spent their time attempting to create a favourable workplace, suggesting, listening and meeting all the requests in short time, working for them was absolutely like "working with them", without their help achieve the result would been greatly harder. Giuseppe Gallo deserve a special thanks too for revising mostly of my work and being always available for support. I had also the chance to share my work during the "Weekly Tracker’s Meetings" dealing with other bright engineers and physicists, between them I really appreciate George Ginter, Russel Rucinski, Yujing Sun and Waqar Ahmed. I want also to express my gratitude to Simone Donati, Giorgio Bellettini and Emanuela Barzi that make this unique experience possible organizing this program for decades. Thanks to my Mother, my Father, my Brother, my Nephew, my uncle Damiano and my friend Simona always near, never stopping to dream with me.

43 PARTICLE ACCELERATORS↗

SELECTION AND PRELIMINARY EVALUATION OF ALTERNATIVE REDUCTANTS FOR SRAT PROCESSING

Defense Waste Processing Facility - Engineering (DWPF-E) has requested the Savannah River National Laboratory (SRNL) to perform scoping evaluations of alternative flowsheets with the primary focus on alternatives to formic acid during Chemical Process Cell (CPC) processing. The reductants shown below were selected for testing during the evaluation of alternative reductants for Sludge Receipt and Adjustment Tank (SRAT) processing. The reductants fall into two general categories: reducing acids and non-acidic reducing agents. Reducing acids were selected as direct replacements for formic acid to reduce mercury in the SRAT, to acidify the sludge, and to balance the melter REDuction/OXidation potential (REDOX). Non-acidic reductants were selected as melter reductants and would not be able to reduce mercury in the SRAT. Sugar was not tested during this scoping evaluation as previous work has already been conducted on the use of sugar with DWPF feeds. Based on the testing performed, the only viable short-term path to mitigating hydrogen generation in the CPC is replacement of formic acid with a mixture of glycolic and formic acids. An experiment using glycolic acid blended with formic on an 80:20 molar basis was able to reduce mercury, while also targeting a predicted REDuction/OXidation (REDOX) of 0.2 expressed as Fe{sup 2+}/{Sigma}Fe. Based on this result, SRNL recommends performing a complete CPC demonstration of the glycolic/formic acid flowsheet followed by a design basis development and documentation. Of the options tested recently and in the past, nitric/glycolic/formic blended acids has the potential for near term implementation in the existing CPC equipment providing rapid throughput improvement. Use of a non-acidic reductant is recommended only if the processing constraints to remove mercury and acidify the sludge acidification are eliminated. The non-acidic reductants (e.g. sugar) will not reduce mercury during CPC processing and sludge acidification would require large amounts of nitric acid (and subsequently larger reductant additions) unless a reducing acid is also used.

54 ENVIRONMENTAL SCIENCES↗

JLab cryomodule assembly infrastructure modifications for LCLS-II

The Thomas Jefferson National Accelerator Facility is currently engaged, along with several other DOE national laboratories, in the Linac Coherent Light Source II project (LCLS II). The SRF Institute at Jefferson Lab will be building 1 prototype and 17 production cryomodules based on the TESLA / ILC / XFEL design. Each cryomodule will contain eight nine cell cavities with coaxial power couplers operating at 1.3 GHz. New and modified infrastructure and assembly tooling is required to construct cryomodules in accordance with LCLS-II requirements. The approach for modifying assembly infrastructure included evaluating the existing assembly infrastructure implemented at laboratories world-wide in support of ILC and XFEL production activities and considered compatibility with existing infrastructure at JLab employed for previous cryomodule production projects. These modifications include capabilities to test cavities, construct cavity strings in a class 10 cleanroom environment, assemble cavity strings into cryostats, and prepare cryomodules for cryogenic performance testing. This paper will give a detailed description of these modifications.

Daly, Edward F.↗