DOE Packaging Certification Program Engineering Class Demonstration Tests

On Thursday August 11, 2022, a series of explosive demonstration tests were conducted at the Sandia National Laboratories 9920 Test Complex for the 2022 DOE Packaging Certification Program Explosives Engineering class. Class participants included both SNL engineering student interns as well as SNL and LANL staff members. The test series was designed by the class instructor, W. Gary Rivera Org. 6626, and 9920 site test engineer, Marissa Martinez Org. 6648, with help from Michelle Chatter Org 6514 and Luke Gilbert Org 6815.

36 MATERIALS SCIENCE↗

Packaging Plan for Mark-18A Plutonium Oxide

Mark-18A (Mk-18A) targets were irradiated at the Savannah River Site and have been in wet storage at the site since the 1970s. The Mk-18A Target Material Recovery Program has been established to recover the 244 Pu and heavy curium (≥50% 246 Cm and 248 Cm) in the targets at the Savannah River National Laboratory (SRNL) and ship the materials to Oak Ridge National Laboratory’s (ORNL’s) Radiochemical Engineering Development Center for programmatic use. Two products will be recovered from the Mk- 18A targets for shipment from SRNL to ORNL: a plutonium oxide stream and an oxide material that will contain the americium, curium, and lanthanides. This document presents the plan for packaging of the plutonium oxide material for shipment and storage at ORNL.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

2023 Status Report - Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC

Thermal, mechanical, and physical properties have been measured on fiberboard samples aging for up to 18 years at accelerated conditions. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coherent Wavelength Switched Co-Packaged Optics to Disrupt Datacenters/HPC (AKA "QRock") (Final Report)

This project resulted in multiple first-of-a-kind demonstrations, including two generations of transmitters, a receiver, and a complete coherent link. The transmitter architecture, based on EAMs to generate QPSK modulation was first demonstrated in InP, which has limitations for scaling up to chips with multiple channels for full WDM architectures, and implementing the densities and level of integration needed to implement co-packaging with electronics. Our work resulted in the first demonstration of this architecture on a Si platform compatible with copackaging, and our working prototypes illustrated the potential of the approach. The link demonstration was also the first coherent optical link realized in a multi-micron waveguide platform. For the transmitters, integrating efficient III-V EAM devices into the large waveguide Si platform simultaneously enables significant reduction in driver power consumption while minimizing optical losses in routing and fiber coupling. On the receiver side, optical coupling and propagation losses are also minimized in the multi-micron platform, reducing required laser optical power which improves link energy efficiency. The measurement results presented in the final report demonstrate that we achieved the speed objectives for the program (112Gb/s: 56Gbaud QPSK), albeit at a higher BER than targeted. The report provides assessments of the low-powercoherent link architecture and associated components developed under the program from both technological and commercial viewpoints.

97 MATHEMATICS AND COMPUTING↗

PyEmittance: A General Python Package for Particle Beam Emittance Measurements With Adaptive Quadrupole Scans [Poster]

We present PyEmittance: a new Python package for general particle beam emittance measurements that offers adaptive quadrupole scans and is designed for robust and flexible integration with Python-based software, with online accelerators, and with simulation software. It is open source software, and can be installed via the command pip install pyemittance.

43 PARTICLE ACCELERATORS↗

Field Aging of Photovoltaic Module Packaging Materials: DuraMAT Field Module Library

To understand and develop models for silicon photovoltaic module degradation, accelerated testing is often used, however, outdoor field testing is necessary for validation. Outdoor field testing publications are often limited by the lack of a pristine, control module to compare the fielded module to. In this work, commercially available modules were purchased from seven different manufacturers for outdoor fielding then destructive characterization to investigate packaging material degradation on

14 SOLAR ENERGY↗

Benchmark Calculation for Turkey Point Unit 3 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

Benchmark calculations were performed for Turkey Point Unit 3 cycles 1–3 to validate the SCALE 6.3/Polaris–PARCS v3.4.2 code with the ENDF/B–VII.1 56–group library by comparing the simulated results with the measured data. The benchmark results will be used in evaluating the SCALE/Polaris–PARCS code package’s uncertainties for pressurized water reactor physics analysis. That future analysis will include key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. The present document details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided with respect to the input and output files produced for the benchmark calculations. The benchmark results are summarized such that they can be used in evaluating uncertainties with other benchmark results for key nuclear parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Calculation for Surry Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

The benchmark calculations were performed for Surry Unit 1 cycles 1–3 to validate the SCALE 6.3/Polaris–Purdue Advanced Reactor Core Simulator (PARCS) v3.4.2 with the ENDF/B–VII.1 56–group library by comparing the simulated results with the measured data. The benchmark results will be used to evaluate uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided for the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties with other benchmark results for key nuclear parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Calculation for the Hatch Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

This study was the performance of the benchmark calculation for the Hatch Unit 1 cycles 1–3, to validate the SCALE 6.3/Polaris–PARCS v3.4.2 with the ENDF/B-VII.1 AMPX 56-group library by comparing the simulated results with the measured data. The benchmark results will be used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for boiling water reactor (BWR) physics analysis for key nuclear parameters such as reactivity and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS and PARCS, and additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties for key nuclear parameters with other BWR benchmark results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmark Calculation for the Peach Bottom Unit 2 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

In this study, benchmark calculations were performed for Peach Bottom Unit 2 cycles 1–3 to validate the SCALE 6.3/Polaris–PARCS v3.4.2 with the ENDF/B-VII.1 AMPX 56-group library by comparing the simulated results with the measured data. The benchmark results will be used to evaluate uncertainties of the SCALE/Polaris–PARCS code package for boiling water reactor physics analysis for key nuclear parameters such as reactivity and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS and PARCS. Additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used to evaluate uncertainties with other benchmark results for key nuclear parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmark Calculation for the Watts Bar Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

Benchmark calculations for the Watts Bar Unit 1 cycles 1–3 were performed to validate the SCALE 6.3/Polaris–PARCS v3.4.2 with the ENDF/B-VII.1 56-group library by comparing the simulated results with the measured data. The benchmark results are used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided for the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties for key nuclear parameters with other benchmark results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydroscanner: Instrumentation for Water Ingress Imaging in Photovoltaic Module Packaging Materials

A new iteration of the Hydroscanner prototype was designed and built during the execution of the contract. Compared to the previous designs, the communication port was changed from ethernet to USB C, since it provides a more seamless integration as a peripheral unit. An additional advantage is that one single port can be used for both communication and power up of the infrared camera. Although the power requirements are higher than the typical amount provided by a laptop computer, the camera can be run as a peripheral from a docking station when connected to a thunderbolt charging port. The software interface was modified to accommodate two imaging modes, an 8-bit and 14-bit image display. The 8-bit images use a custom colorization scheme that divides all pixels in the image into bins of equal width, such that images containing a wide range of brightness display the intermediate pixel intensities in greyscale values that enhance the contrast. The 14-bit images provide the direct readout from the focal plane array of the camera and can be saved as a text file for later processing in other software packages (MATLAB, Python).

47 OTHER INSTRUMENTATION↗

ORNL Portable Diagnostic Package for Evaluating Mirror Performance

Oak Ridge National Laboratory (ORNL) and Realta Fusion successfully executed a one-year collaborative effort to deploy the Portable Diagnostic Package (PDP) on the Wisconsin HTS Axisymmetric Mirror (WHAM) and to assess future diagnostic needs. The PDP consists of an optical emission spectroscopy (OES) subsystem and a Thomson scattering (TS) subsystem. Within the first two months, the PDP OES subsystem was installed, integrated with WHAM timing, and handed over to trained Realta personnel. It immediately delivered multi-channel impurity surveys and the first spatially resolved plasma-rotation profiles inferred from C III Doppler shifts. The TS subsystem was commissioned within the first six months; transportation of the class IV laser system, approval of the safety plan, and the integration with WHAM timing with 100 ns resolution. The TS subsystem provided the first localized electron temperature measurements in WHAM commissioning shots. Leveraging these results, the team has discussed a diagnostic concept map for Realta’s next-step facility, Anvil, identifying line-of-sight constraints, required temporal resolution, and hardware upgrades.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗