Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROTOTYPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

The radiation temperature and M-band fraction inside hohlraum on the SGIII-prototype laser facility

The radiation temperature T{sub R} and M-band fraction f{sub M} inside the vacuum Au hohlraum have been experimentally determined by a shock wave technique and a broadband soft x-ray spectrometer (SXS) on the SGIII-prototype laser facility. From the results of the shock wave technique, T{sub R} is about 202 eV, and f{sub M} is about 9% for the hohlraums driven by a 1 ns flattop pulse of 6 kJ laser energy. The Continuous Phase Plate (CPP) for beam smoothing is applied in the experiment, which increases T{sub R} to 207 eV while has almost no influence on f{sub M}. Comparisons between the results from the two kinds of technologies show that T{sub R} from the shock wave technique is lower than that from SXS whether with CPP or not. However, f{sub M} from the shock wave technique is consistent with that from SXS without CPP, but obviously lower than the SXS's result with CPP. The preheat effect on exterior surface of witness plate is reduced by thicker thickness of witness plate designed for higher laser driven energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The influence of laser clipped by the laser entrance hole on hohlraum radiation measurement on Shenguang-III prototype

Measuring the x-ray flux exiting the target's laser entrance hole (LEH) is the most common diagnostic that quantifies the x-ray intensity inside the laser-driven hohlraum. However, this signal accounts for only a small portion of the incident laser power and thus is likely to be affected by unwanted x-ray background from non-target area, leading to an overestimation of the hohlraum drive. Unwanted emission might be produced when the laser light is clipped by the LEH (LEH clipping) because of a lack of clearance for laser spot, or with a laser spot comprising of discrete structure, or even with a poor pointing accuracy. Its influence on the hohlraum radiation diagnostic is investigated on Shenguang-III prototype laser facility with the typical 1 ns square pulse. The experiment employed three types of targets to excite the unwanted x-ray background from LEH clipping, unconverted light, and both effects, respectively. This work gives an absolute evaluation of x-ray produced by the LEH clipping, which is measured by flat-response x-ray detectors (FXRD) at multiple view angles. The result indicates that there is little variation in measured emission to various view angles, because the unwanted x-rays are mainly generated at the side face of the LEH lip when laser is obliquely incident. Therefore, the LEH clipping brings more overestimation in hohlraum radiation measurement at larger view angle since the hohlraum LEH as an emitting source viewed by FXRD is decreased as the view angle increases. In our condition, the LEH clipping contributes 2%–3.5% overestimation to the hohlraum flux measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Neutron bang time diagnostic system on Shenguang-III prototype

A neutron bang time (NBT) diagnostic system has been implemented on Shenguang-III prototype. The bang time diagnostic system is based on a sensitive fusion neutron detector, which consists of a plastic scintillator and a micro-channel plate photomultiplier tube (PMT). An optical fiber bundle is used to couple the scintillator and the PMT. The bang time system is able to measure bang time above a neutron yield of 10{sup 7}. Bang times and start time of laser were related by probing x-ray pulses produced by 200 ps laser irradiating golden targets. Timing accuracy of the NBT is better than 60 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of stimulated Raman backscatter and stimulated Brillouin backscatter in experiments performed on SG-III prototype facility with a spectral analysis code

Experiments about the observations of stimulated Raman backscatter (SRS) and stimulated Brillouin backscatter (SBS) in Hohlraum were performed on Shenguang-III (SG-III) prototype facility for the first time in 2011. In this paper, relevant experimental results are analyzed for the first time with a one-dimension spectral analysis code, which is developed to study the coexistent process of SRS and SBS in Hohlraum plasma condition. Spectral features of the backscattered light are discussed with different plasma parameters. In the case of empty Hohlraum experiments, simulation results indicate that SBS, which grows fast at the energy deposition region near the Hohlraum wall, is the dominant instability process. The time resolved spectra of SRS and SBS are numerically obtained, which agree with the experimental observations. For the gas-filled Hohlraum experiments, simulation results show that SBS grows fastest in Au plasma and amplifies convectively in C{sub 5}H{sub 12} gas, whereas SRS mainly grows in the high density region of the C{sub 5}H{sub 12} gas. Gain spectra and the spectra of backscattered light are simulated along the ray path, which clearly show the location where the intensity of scattered light with a certain wavelength increases. This work is helpful to comprehend the observed spectral features of SRS and SBS. The experiments and relevant analysis provide references for the ignition target design in future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A prototype silicon double quantum dot with dispersive microwave readout

We present a unique design and fabrication process for a lateral, gate-confined double quantum dot in an accumulation mode metal-oxide-semiconductor (MOS) structure coupled to an integrated microwave resonator. All electrostatic gates for the double quantum dot are contained in a single metal layer, and use of the MOS structure allows for control of the location of the two-dimensional electron gas via the location of the accumulation gates. Numerical simulations of the electrostatic confinement potential are performed along with an estimate of the coupling of the double quantum dot to the microwave resonator. Prototype devices are fabricated and characterized by transport measurements of electron confinement and reflectometry measurements of the microwave resonator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray conversion efficiency and radiation non-uniformity in the hohlraum experiments at Shenguang-III prototype laser facility

The hohlraum radiation properties are studied experimentally by the Shenguang-III prototype laser facility and numerically by the two-dimensional code LARED with the multi-group radiation transfer model. The measured radiation temperature is consistent with the prediction of the simulations in a wide laser energy range, suggesting that the x-ray conversion efficiency is around 75% at the peak radiation temperature. The delicate hohlraum experiments further show that the radiation intensity inside the hohlraum is significantly non-uniform. The measured radiation flux of the hot spot region is over twice higher than that of the re-emitted wall region. Good agreements between the experiments and simulations further demonstrate the validity of the LARED code to study the hohlraum radiation properties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a multi-PMT optical module prototype for PINGU

The multi-PMT digital optical module (mDOM) contains 41 three-inch{sup 2} PMTs in a cylindrical glass vessel. The design is based on the KM3NeT DOM. Among other advantages, this approach offers a significant increase of photocathode area per module and also per string length. As an R and D activity targeted at potential future extensions, this new type of optical modules will be tested in the framework of the PINGU project (Precision IceCube Next Generation Upgrade). PINGU will add denser instrumentation to the IceCube/DeepCore sub-volume aiming at a further decrease of the neutrino energy threshold (to a few GeV). The current status of the development and the prototype construction is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Thomson scattering system on Shenguang-III prototype laser facility

A Thomson scattering diagnostic system, using a 263 nm laser as the probe beam, is designed and implemented on Shenguang-III prototype laser facility. The probe beam is provided by an additional beam line completed recently. The diagnostic system allows simultaneous measurements of both ion feature and red-shifted electron feature from plasmas in a high-temperature (≥2 keV) and high-density (≥10{sup 21} cm{sup −3}) regime. Delicate design is made to satisfy the requirements for successful detection of the electron feature. High-quality ion feature spectra have already been diagnosed via this system in recent experiments with gas-filled hohlraums.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial distribution of the plasma parameters in the RF negative ion source prototype for fusion

A numerical model, based on the fluid plasma theory, has been used for description of the spatial distribution of the plasma parameters (electron density and temperature, plasma potential as well as densities of the three types of positive hydrogen ions) in the IPP prototype RF negative hydrogen ion source. The model covers the driver and the expansion plasma region of the source with their actual size and accounts for the presence of the magnetic filter field with its actual value and location as well as for the bias potential applied to the plasma grid. The obtained results show that without a magnetic filter the two 2D geometries considered, respectively, with an axial symmetry and a planar one, represent accurately the complex 3D structure of the source. The 2D model with a planar symmetry (where the E×B and diamagnetic drifts could be involved in the description) has been used for analysis of the influence, via the charged-particle and electron-energy fluxes, of the magnetic filter and of the bias potential on the spatial structure of the plasma parameters in the source. Benchmarking of results from the code to experimental data shows that the model reproduces the general trend in the axial behavior of the plasma parameters in the source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct-drive cryogenic-target implosion experiments on SGIII prototype laser facility

Directly driven cryogenic target implosion experiments are performed on the SGIII prototype laser facility. X-ray pinhole images reveal frozen condensation on the sealing film. The influence of the condensation on the delivery of laser energy to the capsule surface is then quantified experimentally. It is found that, with a carefully chosen pre-pulse duration, the influence can be reduced, and the neutron yield is increased by an order of magnitude. Subsequently, the cryogenic layered capsule and cryogenic gas-filled capsule are imploded using 6.5-kJ laser energy. The implosion performance is characterized by the neutron yield, the 2D self-emission images of the in-flight shell, and the primary proton spectrum. The neutron yield is 2 × 10{sup 7} for the gas-filled capsule and 2.8 × 10{sup 7} for the layered capsule. The 2D self-emission images of the in-flight shell exhibit significant implosion asymmetry. The energy downshift of the proton spectrum is used to infer the areal density. For the gas-filled capsule, the spectrum is downshifted by 0.1 MeV, yielding an areal density of 1–3 mg/cm{sup 2}. For the layered capsule, the spectrum is downshifted by 0.5 MeV, yielding an areal density of 4–6 mg/cm{sup 2}. Improving the implosion symmetry would help to further increase the areal density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of quasi-elastic scattering in the NOνA near detector prototype

NOvA is a 14 kTon long-baseline neutrino oscillation experiment currently being installed in the NuMI off-axis neutrino beam produced at Fermilab. A 222 Ton prototype NOνA detector was built and operated in the neutrino beam for over a year to understand the response of the detector and its construction. Muon neutrino interaction data collected in this test are being analyzed to identify quasi-elastic charged-current interactions and measure the behavior of the quasi-elastic muon neutrino cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a prototype Open-close positron emission tomography system

We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of {sup 18}F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New two-dimensional space-resolving flux detection technique for measurement of hohlraum inner radiation in Shenguang-III prototype

The space-resolving measurement of X-ray flux from a specific area (laser spot, re-emitting wall, or capsule) inside the hohlraum is an ongoing and critical problem in indirectly driven inertial-confinement fusion experiments. In this work, we developed a new two-dimensional space-resolving flux detection technique to measure the X-ray flux from specific areas inside the hohlraum by using the time- and space-resolving flux detector (SRFD). In two typical hohlraum experiments conducted at the Shenguang-III prototype laser facility, the X-ray flux and radiation temperature from an area 0.2 mm in diameter inside the hohlraum were measured through the laser entrance hole (LEH). The different flux intensities and radiation temperatures detected using the SRFD from the inner area of the LEH were compared with the result measured using the flat-response X-ray detector from the entire LEH. This comparison was also analyzed theoretically. The inner area detected using the SRFD was found to be the re-emitting wall area alone. This important improvement in space-resolving X-ray flux measurement will enhance the current X-ray flux space characterization techniques, thereby furthering the quantitative understanding of X-ray flux space behavior in the hohlraum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (<10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from a diamond placed edge-on to the x-ray beam. Because of the high peak power density of the x-ray beams, this diamond experiences high temperatures and has to be clamped to a water-cooled heat spreader using thermal interface materials (TIMs), which play a key role in reducing the temperature of the diamond. To evaluate temperature changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This study presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

43 PARTICLE ACCELERATORS↗

Modulation calorimetry in diamond anvil cells. II. Joule-heating design and prototypes

Here, Part I shows that quantitative measurements of heat capacity are theoretically possible inside diamond anvil cells via high-frequency Joule heating (100 kHz–10 MHz), opening up the possibility of new methods to detect and characterize transformations at high-pressure such as the glass transitions, melting, magnetic orderings, and the onset of superconductivity. Here, we test the possibility outlined in Part I, using prototypes and detailed numerical models. First, a coupled electrical-thermal numerical model shows that specific heat of metals inside diamond cells can be measured directly using ~1 MHz frequency, with <10% accuracy. Second, we test physical models of high-pressure experiments, i.e., diamond-cell mock-ups. Metal foils of 2–6 μm-thickness are clamped between glass insulation inside diamond anvil cells. Fitting data from 10 Hz to ~30 kHz, we infer the specific heat capacities of Fe, Pt, and Ni with ±20%–30% accuracy. The electrical test equipment generates -80 dBc spurious harmonics, which overwhelm the thermally induced harmonics at higher frequencies, disallowing the high precision expected from numerical models. An alternative Joule-heating calorimetry experiment, on the other hand, does allow absolute measurements with < 10% accuracy, despite the -80 dBc spurious harmonics: the measurement of thermal effusivity, $ \sqrt{ρck}$ (ρ, c , and k being density, specific heat, and thermal conductivity), of the insulation surrounding a thin-film heater. Using a ~50 nm-thick Pt heater surrounded by glass and 10 Hz–300 kHz frequency, we measure thermal effusivity with ±6% accuracy inside the sample chamber of a diamond anvil cell.

42 ENGINEERING↗

Plasma flow measurements in the Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) and comparison with B2.5-Eirene modeling

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory is a linear plasma device that combines a helicon plasma source with additional microwave and radio frequency heating to deliver high plasma heat and particle fluxes to a target. Double Langmuir probes and Thomson scattering are being used to measure local electron temperature and density at various radial and axial locations. A recently constructed Mach-double probe provides the added capability of simultaneously measuring electron temperatures (T e ), electron densities (n e ), and Mach numbers (M). With this diagnostic, it is possible to infer the plasma flow, particle flux, and heat flux at different locations along the plasma column in Proto-MPEX. Preliminary results show Mach numbers of 0.5 (towards the dump plate) and 1.0 (towards the target plate) downstream from the helicon source, and a stagnation point (no flow) near the source for the case where the peak magnetic field was 1.3 T. Measurements of particle flow and n e and T e profiles are discussed. Finally, the extensive coverage provided by these diagnostics permits data-constrained B2.5-Eirene modeling of the entire plasma column, and comparison with results of modeling in the high-density helicon plasmas will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetohydrodynamic pressure drop and flow balancing of liquid metal flow in a prototypic fusion blanket manifold

Understanding magnetohydrodynamic (MHD) phenomena associated with the flow of electrically conducting fluids in complex geometry ducts subject to a strong magnetic field is required to effectively design liquid metal (LM) blankets for fusion reactors. Specifically, accurately predicting the 3D MHD pressure drop and flow distribution is important. To explore these topics, we simulate a LM MHD flow through an electrically non-conducting prototypic manifold for a wide range of flow and geometry parameters using a 3D MHD solver, HyPerComp incompressible MHD solver for arbitrary geometry. The reference manifold geometry consists of a rectangular feeding duct which suddenly expands such that the duct thickness in the magnetic field direction abruptly increases by a factor r exp . Downstream of the sudden expansion, the LM is distributed into several parallel channels. As a first step in qualifying the flow, a magnitude of the curl of the induced Lorentz force was used to distinguish between inviscid, irrotational core flows and boundary and internal shear layers where inertia and/or viscous forces are important. Scaling laws have been obtained which characterize the 3D MHD pressure drop and flow balancing as a function of the flow parameters and the manifold geometry. Associated Hartmann and Reynolds numbers in the computations were ~10 3 and ~10 1 -10 3 , respectively, while r exp was varied from 4 to 12. An accurate model for the pressure drop was developed for the first time for inertial-electromagnetic and viscous-electromagnetic regimes based on 96 computed cases. Analysis reflects that flow balance can be improved by lengthening the distance between the manifold inlet and the entrances of the parallel channels by utilizing the effect of flow transitioning to a quasi-two-dimensional state in the expansion region of the manifold.

42 ENGINEERING↗

First results from the implementation of the ITER diagnostic residual gas analyzer prototype at Wendelstein 7-X

Fusion reactors and long pulse fusion experiments heavily depend on a continuous fuel cycle, which requires detailed monitoring of exhaust gases. We have used a diagnostic residual gas analyzer (DRGA) built as a prototype for ITER and integrated it on the most advanced stellarator fusion experiment, Wendelstein 7-X (W7-X). The DRGA was equipped with a sampling tube and assessed for gas time of flight sample response, effects of magnetic field on gas detection and practical aspects of use in a state of the art fusion environment. The setup was successfully commissioned and operated and was used to observe the gas composition of W7-X exhaust gases. The measured time of flight gas response was found to be in the order of a second for a 7 m sample tube. High values of magnetic field were found to affect the partial pressure readings of the DRGA and suggest that additional shielding is necessary in future experimental campaigns.

47 OTHER INSTRUMENTATION↗