Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Measuring electron-positron annihilation radiation from laser plasma interactions

We investigated various diagnostic techniques to measure the 511 keV annihilation radiations. These include step-wedge filters, transmission crystal spectroscopy, single-hit CCD detectors, and streaked scintillating detection. While none of the diagnostics recorded conclusive results, the step-wedge filter that is sensitive to the energy range between 100 keV and 700 keV shows a signal around 500 keV that is clearly departing from a pure Bremsstrahlung spectrum and that we ascribe to annihilation radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of positronium formation in positron-hydrogen collisions embedded in weakly coupled plasmas

Dynamics of positronium (Ps) formation in an arbitrary s-state from an arbitrary s-state of the hydrogen atom in weakly coupled plasma has been investigated within the framework of a distorted-wave theory. The interactions among the charged particles in the plasma have been represented by Debye-Huckel potentials. Using simple variational hydrogenic wave functions and arbitrary order derivatives of the general three-denominator Lewis integral partial-wave scattering amplitudes have been obtained in closed forms. These distorted-wave scattering amplitudes have been used to make a detailed study on differential and total cross sections. It has been found that screening of the interaction potentials has significant effect on the scattering dynamics. Some notable features of cross sections have also been revealed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Short and medium range order in two-component silica glasses by positron annihilation spectroscopy

The dependence of chemical composition on the average sizes of subnanometer-scale intrinsic structural open spaces surrounded by glass random networks in two-component silica-based glasses was investigated systematically using positronium (Ps) confined in the open spaces. The average sizes of the open spaces for SiO{sub 2}-B{sub 2}O{sub 3} and SiO{sub 2}-GeO{sub 2} glasses are only slightly dependent on the chemical compositions because the B{sub 2}O{sub 3} and GeO{sub 2} are glass network formers that are incorporated into the glass network of the base SiO{sub 2}. However, the open space sizes for all SiO{sub 2}-R{sub 2}O (R = Li, Na, K) glasses, where R{sub 2}O is a glass network modifier that occupies the open spaces, decrease rapidly with an increase in the R{sub 2}O concentration. Despite the large difference in the ionic radii of the alkali metal (R) atoms, the open space sizes decrease similarly for all the alkali metal atoms studied. This dependence of the chemical composition on the open space sizes in SiO{sub 2}-R{sub 2}O observed by Ps shows that the alkali metal atoms do not randomly occupy the structural open spaces, but filling of the open spaces by R{sub 2}O proceeds selectively from the larger to the smaller open spaces as the R{sub 2}O concentrations are increased.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On thermalization of electron-positron-photon plasma

Recently a progress has been made in understanding thermalization mechanism of relativistic plasma starting from a non-equilibrium state. Relativistic Boltzmann equations were solved numerically for homogeneous isotropic plasma with collision integrals for two- and three-particle interactions calculated from the first principles by means of QED matrix elements. All particles were assumed to fulfill Boltzmann statistics. In this work we follow plasma thermalization by accounting for Bose enhancement and Pauli blocking in particle interactions. Our results show that particle in equilibrium reach Bose-Einstein distribution for photons, and Fermi-Dirac one for electrons, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Raman scattering of a photon with frequency doubling by a channelled positron

We have analysed the possibility of appearance of anti-Stokes lines in the spectrum of Raman scattering of a photon by a 'quasi-bound' charged particle in the regime of planar (axial) channelling. It is shown that radiation may emerge at the frequency, which is a combination of the incident photon frequency ω{sub 0} and transition frequency ω{sub i} in the transverse quantised motion of a channelled particle: ω = ω{sub 0} ± 2γ{sup 2}ω{sub i}, where γ is the relativistic (Lorentz) factor of a channelled particle. (nonlinear optical phenomena)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spontaneous electromagnetic fluctuations in a relativistic magnetized electron–positron plasma

Spontaneous fluctuations are a robust phenomenon of plasmas near equilibrium, which does not depend on the existence of instabilities, and their characterization provides valuable information about the role of the relativistic temperatures T∼mc{sup 2} in relativistic regimes. In this paper, we study the broadband spontaneous electromagnetic fluctuations in a relativistic and magnetized pair plasma described by Maxwell–Jüttner distribution functions, based on the fluctuation-dissipation theorem and particle-in-cell simulations. It is shown that the transverse electromagnetic fluctuations are constrained by a temperature-independent critical frequency ω{sub c}=√(Ω{sub c}{sup 2}+(ck){sup 2}), which separates the collisionless damping regime (|ω|<ω{sub c}) from the case where the waves can propagate without damping (|ω|>ω{sub c}). Further, relativistic simulations show an excellent agreement between analytical and numerical results. We expect this formalism to contribute to obtaining useful physical information about the state of relativistic plasmas.

79 ASTRONOMY AND ASTROPHYSICS↗

ELECTRODYNAMICS OF AXISYMMETRIC PULSAR MAGNETOSPHERE WITH ELECTRON-POSITRON DISCHARGE: A NUMERICAL EXPERIMENT

We present the first self-consistent global simulations of pulsar magnetospheres with operating e {sup ±} discharge. We focus on the simple configuration of an aligned or anti-aligned rotator. The star is spun up from a zero (vacuum) state to a high angular velocity, and we follow the coupled evolution of its external electromagnetic field and plasma particles using the ''particle-in-cell'' method. A plasma magnetosphere begins to form through the extraction of particles from the star; these particles are accelerated by the rotation-induced electric field, producing curvature radiation and igniting e {sup ±} discharge. We follow the system evolution for several revolution periods, longer than required to reach a quasi-steady state. Our numerical experiment puts to test previous ideas for the plasma flow and gaps in the pulsar magnetosphere. We first consider rotators capable of producing pairs out to the light cylinder through photon-photon collisions. We find that their magnetospheres are similar to the previously obtained force-free solutions with a Y-shaped current sheet. The magnetosphere continually ejects e {sup ±} pairs and ions. Pair creation is sustained by a strong electric field along the current sheet. We observe powerful curvature and synchrotron emission from the current sheet, consistent with Fermi observations of gamma-ray pulsars. We then study pulsars that can only create pairs in the strong-field region near the neutron star, well inside the light cylinder. We find that both aligned and anti-aligned rotators relax to the ''dead'' state with suppressed pair creation and electric currents, regardless of the discharge voltage.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-F-12A-01: Quantitative Non-Linear Compartment Modeling of 89Zr- and 124I- Labeled J591 Monoclonal Antibody Kinetics Using Serial Non-Invasive Positron Emission Tomography Imaging in a Pre-Clinical Human Prostate Cancer Mouse Model

Purpose: To examine the binding kinetics of human IgG monoclonal antibody J591 which targets prostate-specific membrane antigen (PSMA) in a pre-clinical mouse cancer model using quantitative PET compartmental analysis of two radiolabeled variants. Methods: PSMA is expressed in normal human prostate, and becomes highly upregulated in prostate cancer, making it a promising therapeutic target. Two forms of J591, radiolabeled with either {sup 89}Zr or {sup 124}I, were prepared. {sup 89}Zr is a radiometal that becomes trapped in the cell upon internalization by the antigen-antibody complex, while radioiodine leaves the cell. Mice with prostate cancer xenografts underwent non-invasive serial imaging on a Focus 120 microPET up to 144 hours post-injection of J591. A non-linear compartmental model describing the binding and internalization of antibody in tumor xenograft was developed and applied to the PET-derived time-activity curves. The antibody-antigen association rate constant (ka), total amount of antigen per gram tumor (Ag-total), internalization rate of antibody-antigen complex, and efflux rate of radioisotope from tumor were fitted using the model. The surface-bound and the internalized activity were also estimated. Results: Values for ka, Ag-total, and internalization rate were found to be similar regardless of radiolabel payload used. The efflux rate, however, was ∼ 9-fold higher for {sup 124}I-J591 than for {sup 89}Zr-J591. Time-dependent surface-bound and internalized radiotracer activity were similar for both radiolabels at early times post-injection, but clearly differed beyond 24 hours. Conclusion: Binding and internalization of J591 to PSMA-expressing tumor xenografts were similar when radiolabeled with either {sup 89}Zr or {sup 124}I payload. The difference in efflux of radioactivity from tumor may be attributable to differential biological fate intracellularly of the radioisotopes. This has great significance for radioimmunotherapy and antibody-drug conjugates. Further exploration using the model will examine binding and radioisotope residence as antibody dose is increased to antigen saturation. The Center for Targeted Radioimmunotherapy and Theranostics, Ludwig Center for Cancer Immunotherapy, Memorial Sloan Kettering Cancer Center (MSK), NIH (R25-CA096945). Technical services provided by the MSK Small-Animal Imaging Core Facility were supported by the NIH (R24-CA83084, P30-CA08748, and P50-CA92629; Zanzonico). NCI, Center to Reduce Cancer Health Disparity (R21 CA153177-03; Osborne)

60 APPLIED LIFE SCIENCES↗

WE-G-BRF-06: Positron Emission Tomography (PET)-Guided Dynamic Lung Tumor Tracking for Cancer Radiotherapy: First Patient Simulations

Purpose: PET-guided dynamic tumor tracking is a novel concept of biologically targeted image guidance for radiotherapy. A dynamic tumor tracking algorithm based on list-mode PET data has been developed and previously tested on dynamic phantom data. In this study, we investigate if dynamic tumor tracking is clinically feasible by applying the method to lung cancer patient PET data. Methods: PET-guided tumor tracking estimates the target position of a segmented volume in PET images reconstructed continuously from accumulated coincidence events correlated with external respiratory motion, simulating real-time applications, i.e., only data up to the current time point is used to estimate the target position. A target volume is segmented with a 50% threshold, consistently, of the maximum intensity in the predetermined volume of interest. Through this algorithm, the PET-estimated trajectories are quantified from four lung cancer patients who have distinct tumor location and size. The accuracy of the PET-estimated trajectories is evaluated by comparing to external respiratory motion because the ground-truth of tumor motion is not known in patients; however, previous phantom studies demonstrated sub-2mm accuracy using clinically derived 3D tumor motion. Results: The overall similarity of motion patterns between the PET-estimated trajectories and the external respiratory traces implies that the PET-guided tracking algorithm can provide an acceptable level of targeting accuracy. However, there are variations in the tracking accuracy between tumors due to the quality of the segmentation which depends on target-to-background ratio, tumor location and size. Conclusion: For the first time, a dynamic tumor tracking algorithm has been applied to lung cancer patient PET data, demonstrating clinical feasibility of real-time tumor tracking for integrated PET-linacs. The target-to-background ratio is a significant factor determining accuracy: screening during treatment planning would enable appropriate patient selection for PET-guided dynamic tumor tracking in radiotherapy.

60 APPLIED LIFE SCIENCES↗

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster – 02: Positron Emission Tomography (PET) Imaging Reconstruction using higher order Scattered Photon Coincidences

PET images are affected by the presence of scattered photons. Incorrect scatter-correction may cause artifacts, particularly in 3D PET systems. Current scatter reconstruction methods do not distinguish between single and higher order scattered photons. A dual-scattered reconstruction method (GDS-MLEM) that is independent of the number of Compton scattering interactions and less sensitive to the need for high energy resolution detectors, is proposed. To avoid overcorrecting for scattered coincidences, the attenuation coefficient was calculated by integrating the differential Klein-Nishina cross-section over a restricted energy range, accounting only for scattered photons that were not detected. The optimum image can be selected by choosing an energy threshold which is the upper energy limit for the calculation of the cross-section and the lower limit for scattered photons in the reconstruction. Data was simulated using the GATE platform. 500,000 multiple scattered photon coincidences with perfect energy resolution were reconstructed using various methods. The GDS-MLEM algorithm had the highest confidence (98%) in locating the annihilation position and was capable of reconstructing the two largest hot regions. 100,000 photon coincidences, with a scatter fraction of 40%, were used to test the energy resolution dependence of different algorithms. With a 350–650 keV energy window and the restricted attenuation correction model, the GDS-MLEM algorithm was able to improve contrast recovery and reduce the noise by 7.56%–13.24% and 12.4%–24.03%, respectively. This approach is less sensitive to the energy resolution and shows promise if detector energy resolutions of 12% can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗