Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERFORM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Experimental and Numerical Investigation of the NASA High Efficiency Centrifugal Compressor Vaned Stage Geometry and Aerodynamic Performance

Since its inception in the early 2010s, the NASA High Efficiency Centrifugal Compressor (HECC) has been enigmatic for the propulsion research community: experimental data and numerical simulations of the stage have generally not aligned in their quantifications of performance metrics. Typically, the fault for these disagreements is assigned to the numerical simulations as the simulations are models, and models are inherently incomplete representations of the experiment. This “incompleteness” may manifest in assumptions regarding roughness or heat transfer, simplifications of the flow path (i.e., neglecting bleed flows), or the oft-scapegoated turbulence model. In the case of HECC, recent work showed unexpected discrepancies between the intended impeller geometry defined in the design report (termed Design-Intent) and the manufactured impeller used in the experimental campaigns (termed As-Manufactured). That work used numerical simulations to establish that the geometric differences between the Design-Intent and As-Manufactured impellers were significant enough to result in drastically different performance predictions for the HECC vaneless diffuser configuration. The Design-Intent impeller simulations over predicted the performance relative to the experiment, whereas the As-Manufactured simulations better represented the experimental data, both in terms of one-dimensional performance metrics and spanwise flow profiles. This effort expands on that work by examining in detail the geometry and aerodynamic performance of the HECC vaned diffuser configuration. Further differences between the Design-Intent and As-Manufactured geometries have been discovered in the vaned diffuser and exit guide vanes, and these differences are documented herein. The summations of the geometric differences for all of the components were used to create two numerical models of HECC vaned diffuser configuration: the Design-Intent simulations which are generated from the original geometry definitions given in the design report and the As-Manufactured simulations which are the best available representation of the manufactured compressor hardware used in the experimental test campaigns. In congruence with the earlier vaneless diffuser work, the numerical predictions of the Design-Intent choked mass flow rate, total pressure ratio, and efficiency were notably greater than that of the As-Manufactured simulations. To increase confidence in the experimental dataset, measurements from a recent test campaign conducted in 2024 are used to validate the original experimental data acquired from 2012 to 2014 with good repeatability overall, especially considering the passage of time and differences in the data acquisition systems between the test campaigns. Both numerical simulations were then extensively evaluated against the experimental data. The As-Manufactured simulations provided better estimates of the stage performance than the Design-Intent cases in terms of most performance metrics. Nonetheless, more detailed results still show opportunities for improvement. Despite a more accurate representation of the physical hardware, characterization of the impeller work input remains a challenge even for rigorously developed numerical models.

centrifugal compressor↗

Performance Prediction of Big Data Transfer Through Experimental Analysis and Machine Learning

Big data transfer in next-generation scientific ap- plications is now commonly carried out over connections with guaranteed bandwidth provisioned in High-performance Net- works (HPNs) through advance bandwidth reservation. To use HPN resources efficiently, provisioning agents need to carefully schedule data transfer requests and allocate appropriate band- widths. Such reserved bandwidths, if not fully utilized by the requesting user, could be simply wasted or cause extra overhead and complexity in management due to exclusive access. This calls for the capability of performance prediction to reserve bandwidth resources that match actual needs. Towards this goal, we employ machine learning algorithms to predict big data transfer perfor- mance based on extensive performance measurements, which are collected over a span of several years from a large number of data transfer tests using different protocols and toolkits between various end sites on several real-life physical or emulated HPN testbeds. We first identify a comprehensive list of attributes involved in a typical big data transfer process, including end host system configurations, network connection properties, and control parameters of data transfer methods. We then conduct an in-depth exploratory analysis of their impacts on application- level throughput, which provides insights into big data transfer performance and motivates the use of machine learning. We also investigate the applicability of machine learning algorithms and derive their general performance bounds for performance prediction of big data transfer in HPNs. Experimental results show that, with appropriate data preprocessing, the proposed machine learning-based approach achieves 95% or higher pre- diction accuracy in up to 90% of the cases with very noisy real-life performance measurements.

Yun, Daqing↗

Architecture and Performance of Perlmutter’s 35 PB ClusterStor E1000 All-Flash File System

NERSC's newest system, Perlmutter, features a 35 PB all-flash Lustre file system built on HPE Cray ClusterStor E1000. We present its architecture, early performance figures, and performance considerations unique to this architecture. We demonstrate the performance of E1000 OSSes through low-level Lustre tests that achieve over 90% of the theoretical bandwidth of the SSDs at the OST and LNet levels. We also show end-to-end performance for both traditional dimensions of I/O performance (peak bulk-synchronous bandwidth) and non-optimal workloads endemic to production computing (small, incoherent I/Os at random offsets) and compare them to NERSC's previous system, Cori, to illustrate that Perlmutter achieves the performance of a burst buffer and the resilience of a scratch file system. Finally, we discuss performance considerations unique to all-flash Lustre and present ways in which users and HPC facilities can adjust their I/O patterns and operations to make optimal use of such architectures.

Lockwood, Glenn K↗

Understanding the Uncertainty in the Technical Performance Level Assessment for Wave Energy

In recent years, the design and development of wave energy converters (WECs) has been explored with intense interest, with highly varying design concepts emerging globally across both research enterprises and industry. The design space for WECs is vast - many concepts ranging in functionality, control systems, power development systems, materials, and scale have been ideated and prototyped, but WEC technology has yet to converge. One critical element of the technology trajectory that governs the speed of adoption is the performance of a WEC concept. In analogous but more-established industries (such as aerospace, and environmentally sustainable electronics design), performance assessment is a quantitative method, based on historical data, that is used as an iterative tool to improve the design of these systems early on in the design process. Though more nascent than these approaches, in wave energy R&D, WEC performance has been assessed using the Technology Performance Level (TPL) assessment, which provides designers with a quantitative score, situating a grid-scale WEC concept on a scale from 1-9 (1 being the lowest performance, and 9 being the highest, trending with the oft-used Technology Readiness Level, or TRL). The TPL assessment is designed to be used during design iteration, when a WEC concept is fully ideated, to enable designers to consider potential means of improving the downstream performance of the concept. One concern that may be slowing the adoption of TPL among WEC developers is the inherent uncertainty in the assessment, and how uncertainty in the individual questions asked as part of the assessment may contribute to perceived inaccuracies in the final score. In this work, we explore the uncertainty present in the assessment and quantify this uncertainty using both traditional mathematical operations and a Monte Carlo simulation. Results imply areas of improvement of the TPL assessment, where reducing uncertainty will be most helpful to end users, enabling both TPL practitioners and users to understand with more accuracy those design elements that can be improved to impact device performance most substantively.

techno-economic analysis↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments: Preprint

Existing state-of-the-art of single-phase grid-forming (GFM) inverter are primarily focused on electromagnetic transient simulation, and there are very few works performing hardware test, and there is no clear understanding how the single-phase GFM inverter should behave from a hardware perspective. Therefore, this paper addresses the gap by performing hardware experiment to evaluate the performance of a single-phase GFM hardware inverter. We enrich the existing GFM testing protocols by investigating transient performance of GFM inverters under different grid dynamic events, and quantifiable performance metrics are made to have a common understanding of expected performance of single-phase GFM inverters. A commercial single-phase GFM inverter is used to verify the test protocols and understand the inverter's performance and functionalities.

dynamic events↗

How To Determine and Verify Operations and Maintenance Savings in Energy Savings Performance Contracts

Operations and maintenance (O&M) savings frequently occur in energy savings performance contracts (ESPCs). During FY 2022, 37% of reported annual cost savings for projects awarded under the U.S. Department of Energy (DOE) ESPC indefinite delivery indefinite quantity (IDIQ) contracts and in the performance period were due to O&M or other energy- and/or water-related cost savings, with the balance (63%) from utility cost savings (i.e., energy or water cost savings). Sometimes the energy- and water-related cost savings are acknowledged and included in payments within ESPCs; other times, for various reasons, they are not. As presented in this guide, FEMP recommends including energy- and water-related cost savings that are O&M (including related repair and replacement) savings in the financial aspects of an ESPC, to the extent such savings can be documented. Inclusion of these savings will help augment project scopes and/or lower interest costs (by shortening financing terms). However, there is a burden of proof as to what constitutes acceptability in O&M savings that needs to be carefully considered and documented in individual projects. Beyond promoting a key tenet used in U.S. federal performance contracting—that savings must be from actual budgets and therefore based on the level of O&M that is actually occurring, not what should have been performed—FEMP also recommends good practice in establishing and documenting O&M baselines, formulating the rationale for baseline adjustments during the performance period, and conducting ongoing verification activities. This document concludes with five examples of how O&M savings may be handled, in situations ranging from the partial displacement of O&M contracts to consolidation and “virtualization” of servers in data centers. A key theme that permeates this guide is the importance of thoroughly documenting all conditions and assumptions used in the development of and accounting for O&M costs and savings throughout the ESPC life cycle, from baseline-setting to measurement and verification (M&V) of the savings during each year of the performance period. Doing so not only prevents internal claims of non-performance (especially in the case of staff turnover during the contract term), but also simplifies ordering agency and energy service company (ESCO) response in the event of scrutiny from oversight organizations, such as government audits. While this guide focuses on federal ESPCs, it may also be applicable when O&M savings are included in utility energy service contracts (UESCs) and non-federal ESPCs.

Voss, Phil↗

Predicting future well performance for environmental remediation design using deep learning

Here in this study, we developed a deep learning (DL) framework with a multi-channel three-dimensional convolutional neural network (MC3D-CNN) to predict well performance and thereby assist future environmental remediation design. Such prediction of extraction well performance at designated locations is critical for configuring pump-and-treat (P&T) well network design and operation, setting reasonable target closure dates for overall remedying, and estimating remedy costs. The framework is developed with operational and monitoring data routinely collected during P&T remedy operations, including well extraction and injection rates as well as in situ contaminant concentrations. Traditionally, the collected data were rarely used for purposes other than assessing past well performance and the accuracy of the conceptual site model. However, recent advances in data-driven computational approaches enable better use of the large datasets to inform future well performance, enhance site characterization, and improve remediation planning. In this study, we established a DL framework to integrate transient three-dimensional contaminant plumes and multiple aquifer properties (e.g., hydraulic conductivity and hydrostratigraphic maps) to identify characteristic patterns controlling and representing extraction well mass recovery, aiming at providing future mass recovery estimates for existing wells and candidate wells at any proposed locations. We evaluated our framework by using a realistic synthetic dataset generated from a well-calibrated flow and transport model used in the 200 West Area of the U.S. Department of Energy’s Hanford Site in southeastern Washington state. The multi-channel feature in our framework allows integration of various types and temporal densities of training datasets for DL model development. Overall, we found that the trained DL model achieved an accuracy of over 90% in ranking extraction well performance in validation datasets, and over 80% in predicting high-performance-ranking well locations. This data-informed approach provides a flexible tool to support adaptive site management, streamline decision-making, and potentially reduce remediation time and costs. Our DL framework can be used as a filtering tool to improve the current P&T network optimization design by reducing the number of candidate well locations.

54 ENVIRONMENTAL SCIENCES↗

A hybrid numerical and machine learning framework for evaluating the performance of a 780 cm 2 aqueous organic redox flow battery

Aqueous organic redox flow battery (AORFB) is a promising cost-competitive technology for large-scale energy storage. Among existing work, the dihydroxyphenazine (DHP)-based AORFB has demonstrated high energy density and low capacity degradation in 10 cm2 cells during lab tests. However, its commercial-scale performance in more complex environments remains unknown, posing a barrier for commercialization. To address this gap, this work presents a comprehensive performance evaluation of a 780 cm 2 DHP-based AORFB by combining physics-based numerical model, machine learning (ML)-based surrogate models, and ML-derived sensitivity quantification. Specifically, we first select 12 key battery parameters that include 10 physicochemical quantities and 2 operation quantities, then select 6 performance metrics that include energy efficiency (EE), discharging capacity, charging energy, and power losses due to concentration, activation, and ohmic over-potentials. With such selection, 12800 combinations of the 12 parameters are subsequently generated using the Latin Hypercube Sampling method. These combinations, together with 38 pre-defined State of Charge, are then integrated to a validated AORFB model developed in COMSOL to compute the performance metrics. With both input parameters and performance metrics, 60 deep neural network (DNN) surrogate models are then trained to approximate the relationship between the 10 physicochemical quantities and 6 performance metrics at each flow rate and current density. Sensitivity scores are then calculated based on the DNN models. Two additional sensitivity analysis tools, i.e., MARS, and SHAP, are also used to cross-validate the sensitivity scores from the DNN. The results demonstrate that 1) the standard potential ranks the first in controlling EE and charging energy, 2) the membrane conductivity is most critical for power loss and EE, and 3) specific area and reaction rate control activation power loss.

25 ENERGY STORAGE↗

Planned Investigations to Address Acute Central Nervous System Effects of Space Radiation Exposure with Human Performance Data

This work intends to generate evidence of acute, incremental human performance decrement similar to that due to space radiation andits impacts on the brain, to accompany ongoing human performance modeling work. The planned work will explore the boundaries of human behavioral and performance decrement after exposure to stress, which may be expected based in part on rodent responses found afterexposure to ionizing radiation. The collection of evidence via simulation studies can characterize real human errors toward determining what stress levels lead to significantly-low levels of performance (below permissible outcome limits) which would imperilmission accomplishment. If mission-relevant animal-study-linked tasks are used, human and animal performance levels may be aligned to enable quantitative assignment of permissible exposure limits based on animal exposure studies. Ultimately, a transfer function between the performances of exposed rodents and humans under stress can be developed using shared impairment mechanisms.

human performance↗

Planned Investigations to Address Acute Central Nervous System Effects of Space Radiation Exposure with Human Performance Data

This work intends to generate evidence of acute, incremental human performance decrement similar to that due to space radiation and its impacts on the brain, to accompany ongoing human performance modeling work. The planned work will explore the boundaries of human behavioral and performance decrement after expo-sure to stress, which may be expected based in part on rodent responses found after exposure to ionizing radiation. The collection of evidence via simulation studies can characterize real human errors toward determining what stress levels lead to significantly-low levels of performance (below permissible outcome limits) which would imperil mission accomplishment. If mission-relevant yet animal-study-linked tasks are used, human and animal performance levels may be aligned to enable quantitative assignment of permissible exposure limits based on animal exposure studies. Ultimately, a transfer function between the performances of exposed rodents and humans under stress can be developed using shared impairment mechanisms.

human performance↗

Verifying the structure-property-performance relationship of Y6-based small molecule acceptors by alkoxy-side chain isomerization and conjugated skeleton asymmetry

Non-fullerene small molecule acceptors (NF-SMAs) such as Y6 derivatives were the current working horse for the top performing polymer solar cells (PSCs). For this reason, numerous chemical modifications have been explored for establishing structure–property-performance relationship for Y6-based NF-SMAs. In this work, we explored the isomerization on asymmetrical Y6 derivatives by varying the position of alkoxy side chain on the thiophene linkage between the core and one of the end groups of Y6. The isomers with differences in conformational restriction raised by noncovalent interactions as well as steric hindrance revealed distinctive behavior in crystallization and polymorphism, which led to a significant contrast in PSC performances. Here the X-TO1 molecule with alkoxy side chain facing the end group (outward) displayed preferred molecular configuration and polymorph, delivering power conversion efficiency (PCE) of 15.63%, while its isomer X-TO2 showed coexisted polymorphs significantly increased the charge recombination in the PSC devices led to a low PCE around 3%. This structure–property-performance relationship not only highlighted the elegancy of isomerization in tuning the photovoltaic performances but also identified polymorphism as one of the causes for impairing photovoltaic performances of PSCs.

36 MATERIALS SCIENCE↗

ExaCA v2.0: A versatile, scalable, and performance portable cellular automata application for additive manufacturing solidification

The previously established ExaCA software for performance portable alloy grain structure simulation has been updated to better represent the solidification behavior during complex alloy processing conditions, such as those encountered during metal additive manufacturing (AM), and for improved performance and scalability. Here, an extension to the time–temperature history input data format and the core ExaCA algorithm to include an arbitrary number of melting and solidification events yielded improved prediction of texture for various melt pool geometries, expanding the range of AM-relevant conditions that can be accurately simulated. Improved heat transport process simulation coupling, including the creation of large raster datasets from single track time–temperature history data and in-memory coupling with the new, performance portable finite difference code Finch, were also demonstrated in example studies on the effect of multilayer AM microstructure predictions on hatch spacing and cell size, respectively. Additional new features are detailed and demonstrated, including the ability to perform simulations using various interfacial response function forms, execute simulations on state-of-the-art hardware, improved usability through post-processing versatility, and improved strong and weak scaling performance. The performance, physics, and versatility improvements demonstrated here will further enable large-scale studies on AM process–microstructure relationships that were not previously possible. Furthermore, the usability improvements and ability to run coupled AM process–microstructure simulations using the Finch-ExaCA workflow will facilitate broader use of this open-source software by the computational materials community.

36 MATERIALS SCIENCE↗

Effects of pillar design on the thermal performance of vacuum-insulated glazing

Vacuum-insulated glazing (VIG) with a low-emittance coating has a great market potential as an effective transparent insulator. The thermal insulating performance of VIG is determined by its design, including material selection and configuration of different components. Thermal conductance of the vacuum gap as a transport bottleneck is one of the primary factors controlling the thermal transport across VIG. In particular, because support pillars provide the main thermal transport channels across the vacuum gap, increasing the pillar thermal resistance is a key strategy for creating effective thermal insulation while maintaining the vacuum space. Here, the effects of various pillar design parameters, such as thermal conductivity, geometry, and arrangement, on the VIG thermal performance were comprehensively investigated via the finite element method. In addition, analytical models for thermal transport were examined and thermal conductance across the VIG unit was experimentally measured for validation. The pillar design parameters, especially the height, shape, spacing, and arrangement of the pillars, showed significant effects on the thermal performance of VIG. This research also shows that the smaller contact area for horizontal pillars can effectively decrease the heat loss by more than 30%. Because current VIG analytical equations of thermal performance are only applicable to cylindrical pillars, an analytical equation that can better describe the thermal performance of rectangular parallelepiped pillars is presented, along with a discussion about the mechanism of thermal transfer for different pillar shapes. Thermo-mechanical analyses based on 3D FEM simulations can provide valuable insights into the effect of various design parameters on the overall performance the VIG, allowing for the development of an optimal VIG design.

36 MATERIALS SCIENCE↗

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

Regional suitability of heating tower heat pumps based on technical and economic performance maps

The heating tower heat pump (HTHP) technology is evolving rapidly due to its high performance in summer and frost-free characteristic in winter. However, lacking comprehensive comparisons between the HTHP and conventional methods, such as air-source heat pump (ASHP), and chiller and boiler, greatly limits its applications. To address this problem, this paper carries out technological and economic performance analyses of the three systems in 353 locations over China by the processes of building load calculation, system sizing, annual simulation, performance comparison, and demonstration. Energy saving principle and potential of the HTHP are presented and explained. Based on that, economic performance comparison is conducted by considering the energy conversion efficiency and prices. The results show that the HTHP has advantage over the ASHP in most locations in China. The improvement in annual coefficient of performance (COP) is about 10% to 20%. For the locations in southwest China like Chongqing, the improvement is also less than 10% due to the large regeneration penalization in winter and small difference between dry-bulb and wet-bulb temperature in summer. The annual COP of the HTHP is 10% to 23% higher than that of the chiller and boiler in hot summer and cold winter zone, and cold zone. However, the HTHP shows no advantage over the chiller and boiler in severe cold zone because of the low efficiency of heat pump in winter, neither in hot summer and warm winter zone due to the small heating load. Based on the results, technical and economic performance maps are developed to guide the application of the HTHP in different climate regions.

heating tower heat pump, air-source heat pump, chi↗

Estimation of the Thermal-Fluids and Thermal-Structural Performance of Helium-Cooled Modular Finger-Type Divertors

Over the past decade, our group has investigated the thermal-fluid performance of the helium-cooled modular divertor with multiple jets (HEMJ) and a simplified “flat” design of the HEMJ for long-pulse magnetic fusion energy (MFE) reactors. Experimental studies were performed in a helium (He) loop at the prototypical pressure of 10 MPa, nearly prototypical He temperatures and incident heat fluxes using test sections made from stainless steel and tungsten alloys. Correlations for average Nusselt numbers and pressure loss coefficients were developed from the data and are used to validate computational fluid dynamics (CFD) models. Here, this work presents updated thermal-fluids performance curves based on these correlations that estimate the maximum heat flux that can be accommodated by the plasma-facing surface and coolant pumping power requirements at prototypical operating conditions. Thermal-structural performance curves developed from ITER structural design criteria are introduced, which include protection against ductile and non-ductile failure, ratcheting fatigue, and creep fatigue. The performance design curves for these finger-type divertors demonstrate that the “flat” design, with a significantly less complicated geometry than the HEMJ, has thermal-fluid and thermal-structural performance comparable to the original HEMJ concept, and may be superior in terms of non-ductile failure criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the concentration ratio on the thermal and economic performance of parabolic trough collectors

The thermal and economic performance of parabolic trough collectors (PTCs) and PTCs with double glass envelope (DGE-PTCs) are analyzed in this work. A model including thermal and optical effects is developed to evaluate the efficiency of vacuum and air-filled DGE-PTCs, while an economic model based on two commercial PTCs (SkyTrough and Ultimate Trough collectors) was developed to assess the economic performance. The efficiency and thermal output per unit cost of the proposed DGE-PTCs are analyzed as a function of the concentration ratio and are respectively compared with the thermal and economic performance of traditional and commercial PTCs. The optimum concentration ratio for maximum thermal performance varies from 11.0 to 23.3 for operation temperatures (T HTF ) between 100 degrees C and 400 degrees C, while the optimum concentration ratio for maximum economic performance ranges between 28.9 and 33.2 for the SkyTrough and between 40.0 and 43.8 for the Ultimate Trough collector designs. Finally, the DGE-PTCs present higher thermal and economic performance at high operating temperatures, which presents a valuable opportunity for implementation in new PTC designs pursuing higher operating temperatures to achieve superior thermal cycle efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗