Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PENETRATION DEPTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Bridging the length scales on mechanical property evaluation (Final Report)

The development of small-scale mechanical testing in combination with microstructural investigation is of great interest to the nuclear materials community for both materials development and monitoring applications. Dramatically reducing the sample sizes to reduce radioactivity and obtaining mechanical properties of irradiated samples is truly intriguing. Moreover, such studies promise a range of benefits including cost reduction, fundamental insight in structure-property relationships, increased statistics on less sample material, and reinvestigation of prior irradiated and tested reactor samples while simultaneously enabling the generation of mechanical test data on ion beam irradiated materials with limited penetration depths. Small scale materials testing on sub-sized samples has been studied for several decades, though it has only been after the development of micro-testing based on Focused Ion Beam (FIB) sample manufacturing in that orders of magnitude smaller samples could really be investigated in a quantitative manner. In recent years, small scale mechanical testing techniques at a number of length scales has been developed for both unirradiated and irradiated (ion and neutron) materials. Technological advances made in this field have enabled ex-situ and in-situ transmission electron microscopy (TEM) and scanning electron microscopy (SEM) examination, thus leading to more accurate measurements as well as additional mechanistic information. A recent review of the benefits of these techniques show that these techniques are at a stage to tackle multi-scale ranges of materials investigations and can be utilized to obtain fundamental science-based understanding of nuclear materials. Considering the tremendous advances made, one can see how small-scale mechanical testing techniques combined with modeling can enable true small scale to bulk scale mechanical property correlations. However, for the engineering community to adapt this approach fully, one needs to demonstrate that a) that these techniques can produce results with high fidelity and reproducibility, b) generate engineering stress-strain data that one can utilize to understand bulk behavior, and c) generate new insight into relevant phenomena fostering the true understanding of radiation damage and microstructure in materials for nuclear applications. It is the objective of this proposal to bridge the length scale between macro- and micro- scale mechanical testing of unirradiated and irradiated materials. This involves the development and demonstration of procedures for multi-scale mechanical testing that enable high fidelity reproducibility of data and the generation bulk property data from small-scale mechanical tests. Through this, the proposal aims to enhance the confidence in the obtained data at the smaller length scales and enhance the insight provided from these techniques for bulk scale applications on both unirradiated and irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spent Crystalline Silicotitanate Storage Study

Washington River Protection Solutions is working to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. This goal incorporates the design of a Tank-Side Cesium Removal (TSCR) system, which filters tank waste supernate to remove suspended solids and then removes Cs by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The 137 Cs-depleted product is intended to be sent to the WTP for vitrification. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable. The testing described herein looks to potential upset process conditions where CST storage may be required before various rinse steps are completed. This study evaluated upset conditions at three sequential processing steps envisioned for TSCR (feed, 0.1 M NaOH rinse, water rinse), and in-column drying with compressed air (normal end step) to assess impacts on the nature of the CST bed. Testing was conducted at the small scale (12-mL bed volume); simulated AP-105 tank waste was used as the feed. Following process disruption, the CST bed was dried in place at 70 °C. Post-dried CST bed physical properties (angle of repose, penetration depth, particle morphological changes) were measured to evaluate how CST moved and flowed. The testing is intended to provide a preliminary assessment of issues that may arise from desiccation of CST with the indicated salt solutions in place. Since these were small-scale tests, the processing conditions will not match full scale conditions exactly; however, the tests do provide insight into the impact of stopping processing at an earlier step than normal. Except for the feed that was dried in-place, all other process stop-conditions showed the CST bed flowed well after drying. At this small scale, CST beds would not present an issue for retrievability. The feed that was dried in place had solidified into a rock-hard monolith with no movement possible. Samples had to be chipped from the surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Cost X-Ray CT System for Imaging of Roots

The goal of this project was to develop and demonstrate an innovative, low cost, field deployable, stationary 3D x-ray computed tomography (CT) system that will image total root phenotypes with a micron size resolution at a throughput of hundreds of plants per cycle. This system is based on UHV’s unique low cost linear x-ray tube technology and sophisticated reconstruction & image segmentation algorithms developed at University of Massachusetts, Lowel and University of Nottingham; and was tested for several types of soils at University of Wisconsin and Texas A&M University. Currently, no technologies exist that have been designed to image roots in complex media such as agricultural field conditions. Due to its small size, high resolution & fast imaging of fine roots, low power consumption, large penetration depth (i.e. ability to see through several feet of soil) and ease of field deployability, this CT system will increase the speed and efficacy of discovery, field translation, and deployment of improved crops and systems that improve soil carbon accumulation and storage, decrease N2O emissions, and improve water efficiency leading towards advancements that could mitigate 10% of the total US Greenhouse gases. This degree of imaging in the field has never been available and would be invaluable to scientists in understanding how environmental conditions and phenotypic variations contribute to carbon deposition through root development.

54 ENVIRONMENTAL SCIENCES↗

MULTI-TECHNIQUE CHARACTERIZATION OF SUPERCONDUCTING MATERIALS FOR PARTICLE ACCELERATOR APPLICATIONS

We investigated the performance limitations of superconducting radio-frequency (SRF) cavities and materials using multiple experimental techniques. In particular, this study focuses on understanding the surface properties of nitrogen-doped Nb cavities and super?conducting thin films with higher Tc such as Nb3Sn. The main goal of this work is to use different techniques to better understand each aspect of the complex loss mechanism in superconductors to further improve the already highly efficient SRF cavities. Nitrogen doping applied to a Nb SRF cavity significantly improves the quality factor Q0 compared to a conventional Nb cavity, at an expense of reduced maximum accelerating gradient. The early quench mechanism was analyzed by using temperature maps before and during the quenching. The temperature maps revealed insignificant heating before the quench, and we concluded that nitrogen doping reduces critical magnetic fields in local regions, leading to premature quenching. To understand the origin of the increasing Q0 with the rf field, the density of states (DOS) of cold spots from nitrogen-doped and standard cavities were measured and analyzed using scanning tunneling microscopy. The results suggested that nitrogen doping reduces the spatial inhomogeneity of superconducting properties and shrinks the metallic suboxide layers, which tunes the DOS in such a way as to produce the field-induced reduction in the surface resistance. To characterize SRF thin films, an experimental setup for measuring a coplanar waveguide (CPW) resonator was developed and tested. A surface impedance measurement of the Nb film showed good agreement with the BCS calculation. The preliminary results from measurements of Nb3Sn and NbTiN films are also presented here. The nonlinear Meissner effect was investigated in Nb3Sn film CPW resonators by mea?suring the resonant frequency as a function of a parallel magnetic field. Contrary to a conventional quadratic dependence of the penetration depth ?(B) on the applied magnetic field B, as expected in s-wave superconductors, nearly a linear increase of ?(B) with B was observed. It was concluded that this behavior of ?(B) is due to weakly linked grain bound?aries on the polycrystalline Nb3Sn films, which can mimic the NLME expected in a clean d-wave superconductor.

Makita, Junki↗

Photoinhibition of comammox reaction in Nitrospira inopinata in a dose- and wavelength-dependent manner

Apparent contribution of complete ammonia-oxidizing organisms (comammox) to the global nitrogen cycle highlights the necessity for understanding niche differentiation of comammox bacteria among other ammonia oxidizers. While the high affinity for ammonia of the comammox species Nitrospira inopinata suggests their niche partitioning is expected to be centered in oligotrophic environments, their absence in nutrient-depleted environments (such as the oceans) suggests that other (abiotic) factors might control their distribution and spatial localization within microbial communities. Many ammonia- and nitrite-oxidizing organisms are sensitive to light; however, the photosensitivity of comammox has not been explored. Since comammox bacteria encode enzymatic machinery homologous to canonical ammonia-and nitrite-oxidizers, we hypothesized that comammox N. inopinata, the only available pure culture of this group of microorganisms, may be inhibited by illumination in a similar manner. We evaluated the impact of light intensity, wavelength, and duration on the degree of photoinhibition for cultures of the comammox species N. inopinata and the soil ammonia-oxidizing archaea Nitrososphaera viennensis. Both species were highly sensitive to light. Interestingly, mimicking diurnal light exposure caused an uncoupling of ammonia and nitrite oxidation in N. inopinata, indicating nitrite oxidation might be more sensitive to light exposure than ammonia oxidation. It is likely that light influences comammox spatial distribution in natural environments such as surface fresh waters according to diurnal cycles, light attenuation coefficients, and the light penetration depths. Our findings therefore provide ecophysiological insights for further studies on comammox both in field and laboratory settings.

59 BASIC BIOLOGICAL SCIENCES↗

Nondestructive Ultrasonic Inspection of Composite Materials: A Comparative Advantage of Phased Array Ultrasonic

Carbon- and glass fiber-reinforced polymer (CFRP and GFRP) composite materials have been used in many industries such as aerospace and automobile because of their outstanding strength-to-weight ratio and corrosion resistance. The quality of these materials is important for safe operation. Nondestructive testing (NDT) techniques are an effective way to inspect these composites. While ultrasonic NDT has previously been used for inspection of composites, conventional ultrasonic NDT, using single element transducers, has limitations such as high attenuation and low signal-to-noise ratio (SNR). Using phased array ultrasonic testing (PAUT) techniques, signals can be generated at desired distances and angles. These capabilities provide promising results for composites where the anisotropic structure makes signal evaluation challenging. Defect detection in composites based on bulk and guided waves are studied. The capability of the PAUT and its sensitivity to flaws were evaluated by comparing the signal characteristics to the conventional method. The results show that flaw sizes as small as 0.8 mm with penetration depth up to 25 mm can be detected using PAUT, and the result signals have better characteristics than the conventional ultrasonic technique. In addition, it has been shown that guided wave generated by PAUT also has outstanding capability of flaw detection in composite materials.

36 MATERIALS SCIENCE↗

Post-Closure Performance Assessment for Deep Borehole Disposal of Cs/Sr Capsules

Post-closure performance assessment (PA) calculations suggest that deep borehole disposal of cesium (Cs)/strontium (Sr) capsules, a U.S. Department of Energy (DOE) waste form (WF), is safe, resulting in no releases to the biosphere over 10,000,000 years when the waste is placed in a 3–5 km deep waste disposal zone. The same is true when a hypothetical breach of a stuck waste package (WP) is assumed to occur at much shallower depths penetrated by through-going fractures. Cs and Sr retardation in the host rock is a key control over movement. Calculated borehole performance would be even stronger if credit was taken for the presence of the WP.

58 GEOSCIENCES↗

Quantification of Sub-Pixel Dynamics in High-Speed Neutron Imaging

The high penetration depth of neutrons through many metals and other common materials makes neutron imaging an attractive method for non-destructively probing the internal structure and dynamics of objects or systems that may not be accessible by conventional means, such as X-ray or optical imaging. While neutron imaging has been demonstrated to achieve a spatial resolution below 10 μm and temporal resolution below 10 μs, the relatively low flux of neutron sources and the limitations of existing neutron detectors have, until now, dictated that these cannot be achieved simultaneously, which substantially restricts the applicability of neutron imaging to many fields of research that could otherwise benefit from its unique capabilities. In this work, we present an attenuation modeling approach to the quantification of sub-pixel dynamics in cyclic ensemble neutron image sequences of an automotive gasoline direct injector at a 5 μs time scale with a spatial noise floor in the order of 5 μm.

47 OTHER INSTRUMENTATION↗

Free Electron Laser Measurement of Liquid Carbon Reflectivity in the Extreme Ultraviolet

Ultrafast time-resolved extreme ultraviolet (EUV) reflectivity measurements of optically pumped amorphous carbon (a-C) have been performed with the FERMI free electron laser (FEL). This work extends the energy range used in previous reflectivity studies and adds polarization dependence. The EUV probe is known to be sensitive to lattice dynamics, since in this range the reflectivity is essentially unaffected by the photo-excited surface plasma. The exploitation of both s- and p-polarized EUV radiation permits variation of the penetration depth of the probe; a significant increase in the characteristic time is observed upon increasing the probing depth (1 vs. 5 ps) due to hydrodynamic expansion and consequent destruction of the excited region, implying that there is only a short window during which the probed region is in the isochoric regime. A weak wavelength dependence of the reflectivity is found, consistent with previous measurements and implying a maximum electronic temperature of 0.8 eV ± 0.4.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure and Interdigitation of Chain-Asymmetric Phosphatidylcholines and Milk Sphingomyelin in the Fluid Phase

We addressed the frequent occurrence of mixed-chain lipids in biological membranes and their impact on membrane structure by studying several chain-asymmetric phosphatidylcholines and the highly asymmetric milk sphingomyelin. Specifically, we report trans-membrane structures of the corresponding fluid lamellar phases using small-angle X-ray and neutron scattering, which were jointly analyzed in terms of a membrane composition-specific model, including a headgroup hydration shell. Focusing on terminal methyl groups at the bilayer center, we found a linear relation between hydrocarbon chain length mismatch and the methyl-overlap for phosphatidylcholines, and a non-negligible impact of the glycerol backbone-tilting, letting the sn1-chain penetrate deeper into the opposing leaflet by half a CH 2 group. That is, penetration-depth differences due to the ester-linked hydrocarbons at the glycerol backbone, previously reported for gel phase structures, also extend to the more relevant physiological fluid phase, but are significantly reduced. Moreover, milk sphingomyelin was found to follow the same linear relationship suggesting a similar tilt of the sphingosine backbone. Complementarily performed molecular dynamics simulations revealed that there is always a part of the lipid tails bending back, even if there is a high interdigitation with the opposing chains. The extent of this back-bending was similar to that in chain symmetric bilayers. For both cases of adaptation to chain length mismatch, chain-asymmetry has a large impact on hydrocarbon chain ordering, inducing disorder in the longer of the two hydrocarbons.

59 BASIC BIOLOGICAL SCIENCES↗

High-Frequency 3D Photoacoustic Computed Tomography Using an Optical Microring Resonator

3D photoacoustic computed tomography (3D-PACT) has made great advances in volumetric imaging of biological tissues, with high spatial-temporal resolutions and large penetration depth. The development of 3D-PACT requires high-performance acoustic sensors with a small size, large detection bandwidth, and high sensitivity. In this work, we present a new high-frequency 3D-PACT system that uses a microring resonator (MRR) as the acoustic sensor. The MRR sensor has a size of 80 μ m in diameter and was fabricated using the nanoimprint lithography technology. Using the MRR sensor, we have developed a transmission-mode 3D-PACT system that has achieved a detection bandwidth of ~23 MHz, an imaging depth of ~8 mm, a lateral resolution of 114 μ m, and an axial resolution of 57 μ m. We have demonstrated the 3D PACT’s performance on in vitro phantoms, ex vivo mouse brain, and in vivo mouse ear and tadpole. The MRR-based 3D-PACT system can be a promising tool for structural, functional, and molecular imaging of biological tissues at depths.

47 OTHER INSTRUMENTATION↗

Nondestructive Measurement of Residual Strain in Connecting Rods Using Neutrons

Increasing the strength of materials is effective in reducing weight and boosting structural part performance, but there are cases where the residual strain generated during the process of manufacturing of high-strength materials results in a decline of durability. It is therefore important to understand how the residual strain in a manufactured component changes due to processing conditions. In the case of a connecting rod, because the strain load on the connecting rod rib sections is high, it is necessary to clearly understand the distribution of strain in the ribs. However, because residual strain is generally measured by using X-ray diffractometers or strain gauges, measurements are limited to the surface layer of the parts. Neutron beams, however, have a higher penetration depth than X-rays, allowing for strain measurement in the bulk material. The research discussed within this article consists of nondestructive residual strain measurements in the interior of connecting rods using the Second Generation Neutron Residual Stress Mapping Facility (NRSF2) at Oak Ridge National Laboratory (ORNL), measuring the Fe (211) diffraction peak position of the ferrite phase. The interior strain distribution of the connecting rod, which was prepared under different manufacturing processes, was revealed. By the visualization of interior strains, clear understandings of differences in various processing conditions were obtained. In addition, it is known that the peak width, which is also obtained during measurement, is suggestive of the size of crystallites in the structure; however, the peak width can additionally be caused by microstresses and material dislocations.

36 MATERIALS SCIENCE↗

Non-Destructive Measurement of Residual Strain in Connecting Rods Using Neutrons

Increasing the strength of materials is effective in reducing weight and boosting structural part performance, but there are cases in where the residual strain generated during the process of manufacturing of high-strength materials results in a decline of durability. It is therefore important to understand how the residual strain in a manufactured component changes due to processing conditions. In the case of a connecting rod, because the strain load on the connecting rod rib sections is high, it is necessary to clearly understand the distribution of strain in the ribs. However, because residual strain is generally measured by using X-ray diffractometers or strain gauges, measurements are limited to the surface layer of the parts. Neutron beams, however, have a higher penetration depth than X-rays, allowing for strain measurement in the bulk material. The research discussed within this paper consists of non-destructive residual strain measurements in the interior of connecting rods using the 2nd Generation Neutron Residual Stress Mapping Facility (NRSF2) at Oak Ridge National Laboratory, measuring the Fe (211) diffraction peak position of the ferrite phase. The interior strain distribution of connecting rod, which prepared under different manufacturing processes, was revealed. By the visualization of interior strains, clear understandings of differences in various processing conditions were obtained. In addition, it is known that the peak width, which is also obtained during measurement, is suggestive of the size of crystallites in the structure; however the peak width can additionally be caused by microstresses and material dislocations.

Ikeda, Tomohiro↗

Correcting for filter-based aerosol light absorption biases at the Atmospheric Radiation Measurement program's Southern Great Plains site using photoacoustic measurements and machine learning

Abstract. Measurement of light absorption of solar radiation by aerosols is vital for assessing direct aerosol radiative forcing, which affects local and global climate. Low-cost and easy-to-operate filter-based instruments, such as the Particle Soot Absorption Photometer (PSAP), that collect aerosols on a filter and measure light attenuation through the filter are widely used to infer aerosol light absorption. However, filter-based absorption measurements are subject to artifacts that are difficult to quantify. These artifacts are associated with the presence of the filter medium and the complex interactions between the filter fibers and accumulated aerosols. Various correction algorithms have been introduced to correct for the filter-based absorption coefficient measurements toward predicting the particle-phase absorption coefficient (Babs). However, the inability of these algorithms to incorporate into their formulations the complex matrix of influencing parameters such as particle asymmetry parameter, particle size, and particle penetration depth results in prediction of particle-phase absorption coefficients with relatively low accuracy. The analytical forms of corrections also suffer from a lack of universal applicability: different corrections are required for rural and urban sites across the world. In this study, we analyzed and compared 3 months of high-time-resolution ambient aerosol absorption data collected synchronously using a three-wavelength photoacoustic absorption spectrometer (PASS) and PSAP. Both instruments were operated on the same sampling inlet at the Department of Energy's Atmospheric Radiation Measurement program's Southern Great Plains (SGP) user facility in Oklahoma. We implemented the two most commonly used analytical correction algorithms, namely, Virkkula (2010) and the average of Virkkula (2010) and Ogren (2010)–Bond et al. (1999) as well as a random forest regression (RFR) machine learning algorithm to predict Babs values from the PSAP's filter-based measurements. The predicted Babs was compared against the reference Babs measured by the PASS. The RFR algorithm performed the best by yielding the lowest root mean square error of prediction. The algorithm was trained using input datasets from the PSAP (transmission and uncorrected absorption coefficient), a co-located nephelometer (scattering coefficients), and the Aerosol Chemical Speciation Monitor (mass concentration of non-refractory aerosol particles). A revised form of the Virkkula (2010) algorithm suitable for the SGP site has been proposed; however, its performance yields approximately 2-fold errors when compared to the RFR algorithm. To generalize the accuracy and applicability of our proposed RFR algorithm, we trained and tested it on a dataset of laboratory measurements of combustion aerosols. Input variables to the algorithm included the aerosol number size distribution from the Scanning Mobility Particle Sizer, absorption coefficients from the filter-based Tricolor Absorption Photometer, and scattering coefficients from a multiwavelength nephelometer. The RFR algorithm predicted Babs values within 5 % of the reference Babs measured by the multiwavelength PASS during the laboratory experiments. Thus, we show that machine learning approaches offer a promising path to correct for biases in long-term filter-based absorption datasets and accurately quantify their variability and trends needed for robust radiative forcing determination.

54 ENVIRONMENTAL SCIENCES↗

Modified algesimeter provides accurate depth measurements

Algesimeter which incorporates a standard sensory needle with a sensitive micrometer, measures needle point depth penetration in pain tolerance research. This algesimeter provides an inexpensive, precise instrument with assured validity of recordings in those biomedical areas with a requirement for repeated pain detection or ascertaining pain sensitivity.

Turner, D. P.↗

Response of mouse epidermal cells to single doses of heavy-particles

The survival of mouse epidermal cells to heavy-particles has been studied In Vivo by the Withers clone technique. Experiments with accelerated helium, lithium and carbon ions were performed. The survival curve for the helium ion irradiations used a modified Bragg curve method with a maximum tissue penetration of 465 microns, and indicated that the dose needed to reduce the original cell number to 1 surviving cell/square centimeters was 1525 rads with a D sub o of 95 rads. The LET at the basal cell layer was 28.6 keV per micron. Preliminary experiments with lithium and carbon used treatment doses of 1250 rads with LET's at the surface of the skin of 56 and 193 keV per micron respectively. Penetration depths in skin were 350 and 530 microns for the carbon and lithium ions whose Bragg curves were unmodified. Results indicate a maximum RBE for skin of about 2 using the skin cloning technique. An attempt has been made to relate the epidermal cell survival curve to mortality of the whole animal for helium ions.

Leith, J. T.↗