Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗

Time-resolved detectors for quantum ghost imaging

Quantum ghost imaging is a method that utilizes the correlated detection of two photons to generate an image. One photon is detected by an imaging sensor and the other by a single-element bucket detector. The selection of the imaging sensor and its capabilities relative to the bucket detector impact the quality of the ghost images. This work examines a SPAD array and a photocathode detector as imaging sensors for quantum ghost imaging. We discuss how to achieve optimal images using these two technologies. We also demonstrate that these devices are able to generate ghost images at 1Hz frame rates, expanding the technique to biologically relevant time scales.

36 MATERIALS SCIENCE↗

Acoustic waves from the 2023 April 20 SpaceX Starship rocket explosion travelling in the elevated ‘AtmoSOFAR’ channel

SUMMARY The ability to detect low-frequency sounds from distant energetic events depends on the temperature and wind structure of the atmosphere. Thus, from time to time surface-based acoustic detectors may not be able to capture sounds arriving from certain directions. However, the temperature minimum at the tropopause may create an acoustic duct called the ‘AtmoSOFAR’ channel that could transmit acoustic waves laterally—but perhaps not to the ground. If true, then elevated sensors such as those borne aloft by balloons would record the signatures even in regions where ground-based sensors cannot. This has been difficult to prove because high altitude acoustic sources are rare and balloon deployments are sporadic. This work describes the detection and characterization of powerful acoustic waves generated during the launch and terminal explosion of the SpaceX Starship rocket on 2023 April 20 using a pair of microbarometers on a stratospheric balloon. The signals travelled through the AtmoSOFAR channel, carrying information about the size and nature of their source. This channel also appears to leak some acoustic energy to the ground, in agreement with previous studies. The acoustic yield of the Starship terminal explosion was on the order of $10^3$ tons trinitrotoluene equivalent, which agrees with the estimated fuel load of the vehicle to about a factor of 2, but is two orders of magnitude larger than optical estimates. These results support an earlier study that claimed lateral transmission of sound from a smaller rocket through the AtmoSOFAR channel. The transmission of source information through the AtmoSOFAR channel motivates its use for monitoring other natural and anthropogenic events using balloon-borne sensors. This may become increasingly important as more and more private and government entities conduct spacecraft launches and reentries. It may also provide a means of monitoring clear air turbulence and other sound-generating atmospheric phenomena at a distance.

58 GEOSCIENCES↗

Dynamic attenuation scheme in measurement-device-independent quantum key distribution over turbulent channels

Measurement-device-independent quantum key distribution (MDI QKD) offers great security in practice because it removes all detector side channels. However, conducting MDI QKD over free-space channels is challenging. One of the largest culprits is the mismatched transmittance of the two independent turbulent channels causing a reduced Hong-Ou-Mandel visibility and thus a lower secret key rate. Here we introduce a dynamic attenuation scheme, where the transmittance of each of the two channels is monitored in real time by transmitting bright light pulses from each users to the measurement device. Based on the measured channel transmittance, a suitable amount of attenuation is introduced to the low-loss channel at the measurement device. Our simulation results show a significant improvement of QKD performance, especially when using short raw keys.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Slow-Light Mid-IR Silicon Photonic Chips for NO 2 and CH 4 Gas Detection

A compact, chip-scale mid-infrared gas sensor is demonstrated, leveraging a two-dimensional photonic crystal waveguide (PCW) fabricated on a silicon-on-insulator (SOI) platform. The PCW comprises a hexagonal lattice with lattice constant a = 860 nm and hole radius r = 0.22a, incorporating a central line defect of reduced-radius holes (r s = 0.7r) to induce slow-light propagation near the photonic band edge with a group index of approximately 73, thereby enhancing light-matter interaction. The sensor operates at fundamental absorption wavelengths of 3.42 μm for nitrogen dioxide (NO 2 ) and 3.40 μm for methane (CH 4 ), utilizing the strongest molecular vibrational transitions for maximum sensitivity. Experimental validation was conducted using dynamically diluted gas mixtures generated by mass flow controllers, with signal acquisition performed by a liquid nitrogen-cooled InSb detector. For NO 2 , the sensor exhibited excellent linear response over 5–25 ppm (part per million) with coefficient of determination R 2 = 0.9934, achieving a detection limit of 210 ppb (part per billion)─representing the first reported silicon photonic-based NO 2 detection. For CH 4 , exposure to 25 ppm resulted in a 6.4% decrease in transmitted intensity, demonstrating multigas sensing capability. The CMOS-compatible fabrication process and compact 3 mm device footprint establish this SOI-PCW platform as a scalable, low-power solution for integrated mid-infrared gas sensing, with significant potential for environmental monitoring and industrial safety applications.

Crystals↗

Determining spectral response of the National Ignition Facility particle time of flight diagnostic to x rays

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond detector used for measuring multiple nuclear bang times at the National Ignition Facility. Due to the non-trivial, polycrystalline structure of these detectors, individual characterization and measurement are required to interrogate the sensitivity and behavior of charge carriers. In this paper, a process is developed for determining the x-ray sensitivity of PTOF detectors and relating it to the intrinsic properties of the detector. We demonstrate that the diamond sample measured has a significant non-homogeneity in its properties, with the charge collection well described by a linear model ax + b, where a = 0.63 ± 0.16 V –1 mm –1 and b = 0.00 ± 0.04 V –1 . Finally, we also use this method to confirm an electron to hole mobility ratio of 1.5 ± 1.0 and an effective bandgap of 1.8 eV rather than the theoretical 5.5 eV, leading to a large sensitivity increase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating resource-efficient neutron/gamma classification ML models targeting eFPGAs

There has been considerable interest and resulting progress in implementing machine learning (ML) models in hardware over the last several years from the particle and nuclear physics communities. A big driver has been the release of the Python package, hls4ml, which has enabled porting models specified and trained using Python ML libraries to register transfer level (RTL) code. So far, the primary end targets have been commercial field-programmable gate arrays (FPGAs) or synthesized custom blocks on application specific integrated circuits (ASICs). However, recent developments in open-source embedded FPGA (eFPGA) frameworks now provide an alternate, more flexible pathway for implementing ML models in hardware. These customized eFPGA fabrics can be integrated as part of an overall chip design. In general, the decision between a fully custom, eFPGA, or commercial FPGA ML implementation will depend on the details of the end-use application. In this work, we explored the parameter space for eFPGA implementations of fully-connected neural network (fcNN) and boosted decision tree (BDT) models using the task of neutron/gamma classification with a specific focus on resource efficiency. We used data collected using an AmBe sealed source incident on Stilbene, which was optically coupled to an OnSemi J-series silicon photomultiplier (SiPM) to generate training and test data for this study. We investigated relevant input features and the effects of bit-resolution and sampling rate as well as trade-offs in hyperparameters for both ML architectures while tracking total resource usage. The performance metric used to track model performance was the calculated neutron efficiency at a gamma leakage of 10 -3 . The results of the study will be used to aid the specification of an eFPGA fabric, which will be integrated as part of a test chip.

47 OTHER INSTRUMENTATION↗

Monolayer Sc 2 CF 2 as a Potential Selective and Sensitive NO 2 Sensor: Insight from First-Principles Calculations

Two-dimensional materials with excellent surface–volume ratios and massive reaction sites recently have been receiving attention for gas sensing. With first-principles calculations, we explored the performance of monolayer Sc 2 CF 2 as a gas sensor. We investigated how molecule adsorption affects its electronic structure and optical properties. It is found that a large charge transfer quantity happens between Sc 2 CF 2 and NO 2 , which results from the fact that the lowest unoccupied molecular orbital (LUMO) of NO 2 is below the valence band maximum (VBM) of Sc 2 CF 2 . Moreover, the MD simulation shows that NO 2 can adsorb on the Sc 2 CF 2 surface stably at room temperature. We explored the effect of biaxial strain on the adsorption energy and charge transfer quantity of each system, and the results show that the biaxial strain can enhance both the adsorption energy and charge transfer quantity of the NO 2 system and thus can improve the sensitivity of Sc 2 CF 2 in detecting the NO 2 molecule. Furthermore, we investigated the adsorption behavior and charge transfer of polar polyatomic molecules at the Sc 2 CF 2 surface with h-BN as a substrate, and the results demonstrate that the h-BN substrate can hardly modify the main results. Our result predicts that Sc 2 CF 2 can be a promising selective and sensitive sensor to detect the NO 2 molecule, and could also give a theoretical guide for other terminated MXenes used for gas sensors or detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

MENUS—Materials engineering by neutron scattering

Materials engineering by neutron scattering (MENUS) at the second target station will be a transformational high-flux, versatile, multiscale materials engineering diffraction beamline with unprecedented new capabilities for the study of complex materials and structures. It will support both fundamental and applied materials research in a broad range of fields. MENUS will combine unprecedented long-wavelength neutron flux and unique detector coverage to enable real-time studies of complex structural and functional materials under external stimuli. The incorporated small angle neutron scattering and transmission/imaging capabilities will extend its sensitivity to larger length scales and higher spatial resolution. Multimodal MENUS will provide crystallographic and microstructure data to the materials science and engineering community to understand lattice strain/phase transition/microstructure/texture evolution in three orthogonal directions in complex material systems under combined extreme applied conditions. Finally, the capabilities of MENUS will open new scientific opportunities and meet the research needs for science challenges to enable studies of a range of phenomena and answer the key questions in material design/exploration, advanced material processing, transformative manufacturing, and material operations of national impacts in our daily life.

47 OTHER INSTRUMENTATION↗

Entanglement structures in quantum field theories: Negativity cores and bound entanglement in the vacuum

Here, the many-body entanglement between two finite (size-d) disjoint vacuum regions of noninteracting lattice scalar field theory in one spatial dimension, i.e., a (d A × d B ) mixed Gaussian continuous variable system, is locally transformed into a tensor-product core of (1 A × 1 B ) mixed entangled pairs. Accessible entanglement within these core pairs exhibits an exponential hierarchy and as such identifies the structure of dominant region modes from which vacuum entanglement could be extracted into a spatially separated pair of quantum detectors. Beyond the core, the remaining modes of the halo are determined to be AB separable in isolation, as well as separable from the core. However, state preparation protocols that distribute entanglement in the form of (1 A × 1 B ) mixed core pairs are found to require additional entanglement in the halo that is obscured by classical correlations. This inaccessible (bound) halo entanglement is found to mirror the accessible entanglement, but with a step behavior as the continuum is approached. It remains possible that alternate initialization protocols that do not utilize the exponential hierarchy of core-pair entanglement may require less inaccessible entanglement. Entanglement consolidation is expected to persist in higher dimensions and may aid classical and quantum simulations of asymptotically free gauge field theories, such as quantum chromodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

A versatile Johansson-type tender x-ray emission spectrometer

We present a high energy resolution x-ray spectrometer for the tender x-ray regime (1.6–5.0 keV) that was designed and operated at Stanford Synchrotron Radiation Lightsource. The instrument is developed on a Rowland geometry (500 mm of radius) using cylindrically bent Johansson analyzers and a position sensitive detector. By placing the sample inside the Rowland circle, the spectrometer operates in an energy-dispersive mode with a subnatural line-width energy resolution (~0.32 eV at 2400 eV), even when an extended incident x-ray beam is used across a wide range of diffraction angles (~30° to 65°). The spectrometer is enclosed in a vacuum chamber, and a sample chamber with independent ambient conditions is introduced to enable a versatile and fast-access sample environment (e.g., solid/gas/liquid samples, in situ cells, and radioactive materials). The design, capabilities, and performance are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

Experimental determination of axion signal power of dish antennas and dielectric haloscopes using the reciprocity approach

The reciprocity approach is a powerful method to determine the expected signal power of axion haloscopes in a model-independent way. Especially for open and broadband setups like the MADMAX dielectric haloscope the sensitivity to the axion field is difficult to calibrate since they do not allow discrete eigenmode analysis and are optically too large to fully simulate. The central idea of the reciprocity approach is to measure a reflection-induced test field in the setup instead of trying to simulate the axion-induced field. In this article, the reciprocity approach is used to determine the expected signal power of a dish antenna and a minimal dielectric haloscope directly from measurements. The results match expectations from simulation but also include important systematic effects that are too difficult to simulate. In particular, the effect of antenna standing waves and higher order mode perturbations can be quantified for the first time in a dielectric haloscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

An improved Method for Determining Transient Fuel Dilution of Oil in an Internal-Combustion Engine Using Laser-Induced Florescence and Multivariate Least Square Calibration

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil or fuel in oil (FIO). Fuel dilution of oil is broadly relevant to advancing engine technology including durability, calibration, and catalyst-system management, and believed to promote destructive stochastic pre-ignition (SPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of real-time transient measurements, the LIF technique resolves transient dilution on the minutes time scale. We have expanded on our original FIO instrument development by introducing an improved analysis based on multivariate least square chemometrics analysis. The measurement uses a fuel dye (180–1300 parts per million, by mass) and monitors for its presence in the oil using 532 nm excitation and LIF. While the original FIO instrument utilized a two-color ratio method for analysis, the improved chemometric analysis uses the fully resolved LIF dye spectra to provide better predictive FIO accuracy (>92%) over a wide FIO range (1.5–14%) typical of engine application. We also investigate the effect of oil temperature on the LIF signal. Limited engine applications for demonstrating and validating the improved FIO instrument are shown, and the related data used to quantify practical detection limit and sensitivity. The improved analysis is insensitive to laser power fluctuation and change in detector integration time, providing an excellent FIO sensitivity (1–2%) and detection limit (0.01 %FIO) over a wide range of loads and injection timings, illustrating this updated approach to be a promising tool for advancing engine technology.

42 ENGINEERING↗