Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

738 records · Page 41

Simulating a Nationally Representative Housing Sample Using EnergyPlus

This report presents a new simulation tool under development at Lawrence Berkeley National Laboratory (LBNL). This tool uses EnergyPlus to simulate each single-family home in the Residential Energy Consumption Survey (RECS), and generates a calibrated, nationally representative set of simulated homes whose energy use is statistically indistinguishable from the energy use of the single-family homes in the RECS sample. This research builds upon earlier work by Ritchard et al. for the Gas Research Institute and Huang et al. for LBNL. A representative national sample allows us to evaluate the variance in energy use between individual homes, regions, or other subsamples; using this tool, we can also evaluate how that variance affects the impacts of potential policies. The RECS contains information regarding the construction and location of each sampled home, as well as its appliances and other energy-using equipment. We combined this data with the home simulation prototypes developed by Huang et al. to simulate homes that match the RECS sample wherever possible. Where data was not available, we used distributions, calibrated using the RECS energy use data. Each home was assigned a best-fit location for the purposes of weather and some construction characteristics. RECS provides some detail on the type and age of heating, ventilation, and air-conditioning (HVAC) equipment in each home; we developed EnergyPlus models capable of reproducing the variety of technologies and efficiencies represented in the national sample. This includes electric, gas, and oil furnaces, central and window air conditioners, central heat pumps, and baseboard heaters. We also developed a model of duct system performance, based on in-home measurements, and integrated this with fan performance to capture the energy use of single- and variable-speed furnace fans, as well as the interaction of duct and fan performance with the efficiency of heating and cooling equipment. Comparison with RECS revealed that EnergyPlus did not capture the heating-side behavior of heat pumps particularly accurately, and that our simple oil furnace and boiler models needed significant recalibration to fit with RECS. Simulating the full RECS sample on a single computer would take many hours, so we used the 'cloud computing' services provided by Amazon.com to simulate dozens of homes at once. This enabled us to simulate the full RECS sample, including multiple versions of each home to evaluate the impact of marginal changes, in less than 3 hours. Once the tool was calibrated, we were able to address several policy questions. We made a simple measurement of the heat replacement effect and showed that the net effect of heat replacement on primary energy use is likely to be less than 5%, relative to appliance-only measures of energy savings. Fuel switching could be significant, however. We also evaluated the national and regional impacts of a variety of 'overnight' changes in building characteristics or occupant behavior, including lighting, home insulation and sealing, HVAC system efficiency, and thermostat settings. For example, our model shows that the combination of increased home insulation and better sealed building shells could reduce residential natural gas use by 34.5% and electricity use by 6.5%, and a 1 degree rise in summer thermostat settings could save 2.1% of home electricity use. These results vary by region, and we present results for each U.S. Census division. We conclude by offering proposals for future work to improve the tool. Some proposed future work includes: comparing the simulated energy use data with the monthly RECS bill data; better capturing the variation in behavior between households, especially as it relates to occupancy and schedules; improving the characterization of recent construction and its regional variation; and extending the general framework of this simulation tool to capture multifamily housing units, such as apartment buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of uncoordinated plug-in electric vehicle charging on residential power demand - supplementary data

This data set is provided in support of a forthcoming paper: "Impact of uncoordinated plug-in electric vehicle charging on residential power demand," [1]. These files include electricity demand profiles for 200 households randomly selected among the ones available in the 2009 RECS data set for the Midwest region of the United States. The profiles have been generated using the modeling proposed by Muratori et al. [2], [3], that produces realistic patterns of residential power consumption, validated using metered data, with a resolution of 10 minutes. Households vary in size and number of occupants and the profiles represent total electricity use, in watts. The files also include in-home plug-in electric vehicle recharging profiles for 348 vehicles associated with the 200 households assuming both Level 1 (1920 W) and Level 2 (6600 W) residential charging infrastructure. The vehicle recharging profiles have been generated using the modeling proposed by Muratori et al. [4], that produces real-world recharging demand profiles, with a resolution of 10 minutes. [1] M. Muratori, "Impact of uncoordinated plug-in electric vehicle charging on residential power demand." Forthcoming. [2] M. Muratori, M. C. Roberts, R. Sioshansi, V. Marano, and G. Rizzoni, "A highly resolved modeling technique to simulate residential power demand," Applied Energy, vol. 107, no. 0, pp. 465 - 473, 2013. [3] M. Muratori, V. Marano, R. Sioshansi, and G. Rizzoni, "Energy consumption of residential HVAC systems: a simple physically-based model," in 2012 IEEE Power and Energy Society General Meeting. San Diego, CA, USA: IEEE, 22-26 July 2012. [4] M. Muratori, M. J. Moran, E. Serra, and G. Rizzoni, "Highly-resolved modeling of personal transportation energy consumption in the United States," Energy, vol. 58, no. 0, pp. 168-177, 2013.

2009 RECS↗

Numerical Investigation of the Electrical Resistivity Tomography for Detecting the Waste Zone beneath an Engineered Surface - 19066

Surface barriers are an integral part of waste site remediation that are needed to minimize further contamination spread, allow time for additional radionuclide decay, and decrease risks to workers and the environment. Depending on the type of waste, the design life of a surface barrier varies from decades to millennia. The performance and impacts of surface barriers must be monitored beyond the life of most monitoring instruments; hence, long-term monitoring technologies are needed that can non-intrusively assess barrier impacts both in the near surface and to large depths. Innovative geophysical methods such as the electrical resistivity tomography (ERT) are capable of nonintrusively detecting the distribution of soil wetness and/or contaminant plumes in the soil. However, the application of geophysical methods in monitoring a surface barrier system has been very limited because a surface barrier is often composed of multiple components made of natural (e.g., soil, rocks, asphalt) and manufactured (e.g., plastic, metal) materials. In this study, the E4D numerical simulator, developed at Pacific Northwest National Laboratory for inverting the ERT survey data, was used to evaluate the configuration of electrodes for optimized ERT monitoring of waste zone below a surface barrier. The results indicate that, for high-quality mapping of the conditions below the surface barrier, the ERT method requires that some of the electrodes be installed either beneath the surface barrier or in boreholes around the barrier. In reality, for a surface barrier that is being constructed, some electrodes may be installed beneath the non-conductive layer of the surface barrier before or during barrier construction. For a surface barrier that has already been constructed, some electrodes can be installed in a few vertical boreholes around the barrier boundary. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States. LBNL performed its field-metering study from mid-April to late October 2014. The study, which monitored 19 sites in the Northeastern United States (4 in upstate New York and 15 near Philadelphia), collected real-time data on PAC energy consumption along with information regarding housing characteristics, consumer behavior, and environmental conditions that were expected to affect PAC performance. Given the limited number of test sites, this study was not intended to be statistically representative of PAC users in the United States but rather to understand the system response to the cooling demand and to some extent, the operating hours of the studied units. Specifically, the primary objectives of the field-metering study were to (1) expand knowledge of the installation, energy consumption profiles, consumer patterns of use, and environmental parameters related to PAC use; (2) develop distributions of hours of PAC operation for three operating modes: standby, 1 fan-only, and cooling; and (3) describe how individual consumers’ selection of PAC capacity, the area of the space to be cooled, the temperature set point, and environmental conditions affect energy use. Beginning to understand the energy consumption of PACs operating in American homes and commercial settings will help develop a more accurate energy use profile that characterizes relevant variables. This report on LBNL’s field-metering study of PAC energy use describes: a general definition of a PAC and how it operates (section 2); current practices and sources of data for estimating PAC energy use (section 3); the process LBNL used to select field-metering sites, along with characteristics of the sites and the PACs studied (section 4); data collection methods and instrumentation (section 5); analysis methods (section 6); results and discussion (section 7); and conclusions (section 8).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Charge radii in covariant density functional theory: A global view

A systematic global investigation of differential charge radii has been performed within the CDFT framework for the first time. Theoretical results obtained with conventional covariant energy density functionals and the separable pairing interaction of Tian et al. [Phys. Lett. B 676, 44 (2009)] are compared with experimental differential charge radii in the regions of the nuclear chart in which available experimental data crosses the neutron shell closures at N=28,50,82, and 126. The analysis of absolute differential radii of different isotopic chains and their relative properties indicate clearly that such properties are reasonably well described in model calculations in the cases when the mean-field approximation is justified. However, while the observed clusterization of differential charge radii of different isotopic chains is well described above the N=50 and N=126 shell closures, it is more difficult to reproduce it above the N=28 and N=82 shell closures because of possible deficiencies in the underlying single-particle structure. The impact of the latter has been evaluated for spherical shapes and it was shown that the relative energies of the single-particle states and the patterns of their occupation with increasing neutron number have an appreciable impact on the evolution of the δ$\langle$r2$\rangle$N,N' values. These factors also limit the predictive power of model calculations in the regions of high densities of the single-particle states of different origin. It is shown that the kinks in the charge radii at neutron shell closures are due to the underlying single-particle structure and due to weakening or collapse of pairing at these closures. The regions of the nuclear chart in which the correlations beyond mean field are expected to have an impact on charge radii are indicated; the analysis shows that the assignment of a calculated excited prolate minimum to the experimental ground state allows us to understand the trends of the evolution of differential charge radii with neutron number in many cases of shape coexistence even at the mean-field level. It is usually assumed that pairing is a dominant contributor to odd-even staggering (OES) in charge radii. Our analysis paints a more complicated picture. It suggests a new mechanism in which the fragmentation of the single-particle content of the ground state in odd-mass nuclei due to particle-vibration coupling provides a significant contribution to OES in charge radii.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Autonomous Radiation Survey Inside Contaminated Buildings at Fukushima Daiichi with the Riser UAV - 18299

Nuclear decommissioning is constrained and defined by radiation and radioactive contamination. Where radiation is high and its distribution is unknown simply gathering the data needed for project planning can become a challenge. Fukushima Daiichi epitomises this challenge. The complex sequence of events at the plant following the March 2011 earthquake and tsunami has resulted in extensive physical damage and an essentially unpredictable distribution of contamination. TEPCO have applied a range of manual and robotics techniques to map the status of the plant, but many significant areas have remained no-go zones due to a combination of high radiation, physical hazards and obstacles. Further, even in areas where manual survey is feasible, there is strong desire to minimise human exposure to radiation by deploying robots where possible. Riser is a fully autonomous UAV equipped with an infrastructure-free 3D navigation and mapping system, inspection cameras and a CZT spectrometric measurement capability. The system has been custom designed specifically to meet the needs of the nuclear inspection. Riser is capable of accessing areas with dose rates of hundreds of milli-sievert per hour and producing 3D models and radiation surveys with accurately located data points. The data from Riser can subsequently be fused using Createc's N-Visage engine to produce three-dimensional contamination maps which can be used for predictive modelling of future D and D activity. Riser has been deployed at Fukushima Daiichi since March 2017. We present examples of data and analysis outputs, as well as general learning about deploying autonomous robots at a nuclear site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear Waste Tank Emission Contributions to Particle Size Distribution

Pollutants from anthropogenic activities including industrial processes are ubiquitous to the environment. To understand the impact from industrial aerosol on climate and human health, industrial aerosol needs to be better characterized. Here, in this study, particle number concentrations were used as a proxy for atmospheric pollutants, which include both particles and gases. Particle concentration and size distribution were measured using a scanning mobility particle sizer (SMPS) approximately 4.5 km from primary industrial areas at the Savannah River Site in Aiken, SC. Industrial areas include numerous nuclear waste storage and processing tanks. The SMPS data were divided into two groups depending on the wind direction measured onsite to categorize transport from the industrial area or from elsewhere. Industrial contributions were found to have a higher concentration of particles with sizes less than 200 nm, 859 ± 564 cm -3 , in comparison to non-industrial attributed particles, 733 ± 495 cm -3 on average from March-July 2021. For sizes larger than 200 nm, industrial and non-industrial particles have a similar concentration, 89 ± 59 cm -3 and 99 ± 61 cm -3 , with non-industrial concentrations being slightly larger. To confirm that industrial particles could travel to the sampling location, air dispersion modeling was completed for specific case studies during the sampling period. The atmospheric dispersion modeling results confirmed that particles released at the industrial areas reached the sampling location when the wind direction was favorable for transport from the industrial areas. The greater concentration of smaller-sized particles in industrial emissions has implications for typical particulate measurements (PM2.5), heath impacts, and climatological influences.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Emissions and Crystalline Silica Content of Airborne Dust Generated from Grinding Natural and Engineered Stones

Abstract In this study, we systematically characterized the airborne dust generated from grinding engineered and natural stone products using a laboratory testing system designed and operated to collect representative respirable dust samples. Four stone samples tested included two engineered stones consisting of crystalline silica in a polyester resin matrix (formulations differed with Stones A having up to 90wt% crystalline silica and Stone B up to 50wt% crystalline silica), an engineered stone consisting of recycled glass in a cement matrix (Stone C), and a granite. Aerosol samples were collected by respirable dust samplers, total dust samplers, and a Micro-Orifice Uniform Deposit Impactor. Aerosol samples were analyzed by gravimetric analysis and x-ray diffraction to determine dust generation rates, crystalline silica generation rates, and crystalline silica content. Additionally, bulk dust settled on the floor of the testing system was analyzed for crystalline silica content. Real-time particle size distributions were measured using an Aerodynamic Particle Sizer. All stone types generated similar trimodal lognormal number-weighted particle size distributions during grinding with the most prominent mode at an aerodynamic diameter of about 2.0-2.3 μm, suggesting dust formation from grinding different stones is similar. Bulk dust from Stone C contained no crystalline silica. Bulk dust from Stone A, Stone B, and granite contained 60, 23, and 30wt% crystalline silica, respectively. In Stones A and B, the cristobalite form of crystalline silica was more plentiful than the quartz form. Only the quartz form was detected in granite. The bulk dust, respirable dust, and total dust for each stone had comparable amounts of crystalline silica, suggesting that crystalline silica content in the bulk dust could be representative of that in respirable dust generated during grinding. Granite generated more dust per unit volume of material removed than the engineered stones, which all had similar normalized dust generation rates. Stone A had the highest normalized generation rates of crystalline silica, followed by granite, Stone B, and Stone C (no crystalline silica), which likely leads to the same trend of respirable crystalline silica (RCS) exposure when working with these different stones. Manufacturing and adoption of engineered stone products with formulations such as Stone B or Stone C could potentially lower or eliminate RCS exposure risks. Combining all the effects of dust generation rate, size-dependent silica content, and respirable fraction, the highest normalized generation rate of RCS consistently occurs at 3.2-5.6 µm for all the stones containing crystalline silica. Therefore, removing particles in this size range near the generation sources should be prioritized when developing engineering control measures.

Public, Environmental & Occupational Health↗

Channels occupancy and distortion in new lithium uranyl phosphates with three-dimensional open-frameworks

Three new lithium uranyl phosphates, Li{sub 2}(UO{sub 2}){sub 3}(PO{sub 4}){sub 2}O (1), Li(UO{sub 2}){sub 4}(PO{sub 4}){sub 3} (2) and Li{sub 3}(UO{sub 2}){sub 7}(PO{sub 4}){sub 5}O (3) were synthesized and studied. Powders of 1 and 2 were synthesized via solid state reaction, and single crystals of the three compounds were obtained by melting of 1 and 2 powders. The structures of the three compounds have been solved and refined from single crystal X-ray diffraction data. In the three compounds, the uranium atoms occupy square and pentagonal bipyramids. The uranium square bipyramids and phosphate tetrahedra are connected by vertices to form two types of layers with autunite sheet anion-topology {sub i}nfinity{sup 2}[(UO{sub 2})(PO{sub 4}){sub 2}]{sup 4-} and {sub i}nfinity{sup 2}[(UO{sub 2}){sub 2}(PO{sub 4}){sub 3}]{sup 5-}denoted S and D, respectively. The uranyl pentagonal bipyramids share opposite equatorial edges to form {sub i}nfinity{sup 1}[UO{sub 5}]{sup 4-} infinite chains. Mutually perpendicular chains are hung on each side of the sheets to build frameworks with non-crossing perpendicular channels that accommodate the lithium ions. Various stacking sequences of the S and D layers, S-S, D-D and S-D, generate three different frameworks in 1, 2 and 3, respectively. These compounds are similar to the recently reported vanadate analogous. However, the phosphate tetrahedra, smaller than the vanadate ones, gives distortion of the layers and a lowering of the symmetry and/or a change of periodicity. The electrical conductivity of 1 and 2 was measured using impedance spectroscopy method. The rather low conductivity of the lithium cations is explained by the crystal structure and the Li{sup +} position within the tunnels. These results corroborate those on the analogous three-dimensional alkaline uranyl vanadates. Crystallographic data: 293 K, BRUKER X8-APEX2 X-ray diffractometer, 4 K CCD detector, MoKalpha, lambda=0.71073 A, full-matrix least-squares refinement on the basis of F. 1, Tetragonal symmetry, space group I4{sub 1}/amd, Z=4 with a=7.1109(2) A and c=25.0407(8) A, R=0.034 and wR=0.047 for 38 parameters with 479 independent reflections with I>=3sigma(I). 2, monoclinic symmetry, space group P2{sub 1}/c, Z=4 and a=9.8829(2) A, b=9.8909(2) A, c=17.4871(4) A and beta=106.198(1){sup o}, R=0.021 and wR=0.031 for 249 parameters with 4201 independent reflections with I>=3sigma(I). 3, Tetragonal symmetry, space group P4-bar2{sub 1}m with a=9.9305(2) A and c=14.5741(3) A, R=0.035 and wR=0.038 for 137 parameters with 4527 independent reflections with i>=3sigma(I). - Graphical abstract: The three new lithium uranyl phosphates Li{sub 2}(UO{sub 2}){sub 3}(PO{sub 4}){sub 2}O, Li(UO{sub 2}){sub 4}(PO{sub 4}){sub 3} and Li{sub 3}(UO{sub 2}){sub 7}(PO{sub 4}){sub 5}O were synthesised via solid state reaction. The structures of these compounds are based upon three-dimensional open-frameworks built from {sub i}nfinity{sup 1}[UO{sub 5}]{sup 4-} chains connected through two types of layers, S and D, in the sequences S-S, D-D and S-D, respectively. The lithium atoms distribution along the channels induces various distortions of the {sub i}nfinity{sup 1}[UO{sub 5}]{sup 4-} chains.

36 MATERIALS SCIENCE↗

A Computational Review of Privacy-Preserving Mechanisms for the Smart Grid

Smart grid technologies have rapidly become one of the largest and most comprehensive sources of data for the modern utility. For the most part, data streams are seen as an essential tool that enable utilities to carry their day-to-day business operations, but they also create the need for efficient and secure data management strategies. In the context of the smart grid, ensuring data privacy is becoming an increasing concern due to a combination of factors that range from shifts in operational paradigms and rapid technology evolution to changes in legislation. Furthermore, researchers have highlighted the risks associated with improperly protected energy records. For example, energy consumption data from homes could be used to infer the behaviors and habits of home occupants through activity recognition or user profiling (Fan, 2017), which may lead to unfair service pricing, targeted advertising, or other personal security violations. Similarly, Electric Vehicles’ (EVs) charging metadata could be used to reveal private information about the owner such as their payment methods, preferred charging stations, and other locational and timing information that could be used to reconstruct the vehicle owner’s behaviors. The privacy of user data, even when used for statistical analysis or machine learning training processes, also needs to be carefully considered, as an individual’s private traits may still be vulnerable if their inclusion/exclusion greatly impacts the result or could be linked to a public dataset through cross-reference. The breach of user privacy also has severe impacts for organizations that store, transmit, or work on the data in the form of diminishing the public’s trust in them while potentially incurring legal consequences (e.g., fines and suspensions under the European Union General Data Protection Regulation, Health Insurance Portability and Accountability Act, etc.). Because of these risks, several privacy-preserving mechanisms are available to help organizations comply with privacy legislations and prevent the unauthorized and malicious use of user data. In light of these concerns, this report focuses on performing a computational review of privacy-preserving mechanisms that have received a significant amount of interest in literature. It specifically focuses on 1) homomorphic encryption, 2) zero-knowledge proofs, 3) differential privacy, and 4) federated learning. It is worth noting that although many of the methods presented in this document rely on cryptographic primitives, their intent is not to provide perfect secrecy, but rather to enable users to maintain privacy, and thus they shall not be compared or equated to other constructs that are aimed to address cybersecurity constructs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A proposed framework for the development and qualitative evaluation of West Nile virus models and their application to local public health decision-making

West Nile virus (WNV) is a globally distributed mosquito-borne virus of great public health concern. The number of WNV human cases and mosquito infection patterns vary in space and time. Many statistical models have been developed to understand and predict WNV geographic and temporal dynamics. However, these modeling efforts have been disjointed with little model comparison and inconsistent validation. In this paper, we describe a framework to unify and standardize WNV modeling efforts nationwide. WNV risk, detection, or warning models for this review were solicited from active research groups working in different regions of the United States. A total of 13 models were selected and described. The spatial and temporal scales of each model were compared to guide the timing and the locations for mosquito and virus surveillance, to support mosquito vector control decisions, and to assist in conducting public health outreach campaigns at multiple scales of decision-making. Our overarching goal is to bridge the existing gap between model development, which is usually conducted as an academic exercise, and practical model applications, which occur at state, tribal, local, or territorial public health and mosquito control agency levels. The proposed model assessment and comparison framework helps clarify the value of individual models for decision-making and identifies the appropriate temporal and spatial scope of each model. This qualitative evaluation clearly identifies gaps in linking models to applied decisions and sets the stage for a quantitative comparison of models. Specifically, whereas many coarse-grained models (county resolution or greater) have been developed, the greatest need is for fine-grained, short-term planning models (m–km, days–weeks) that remain scarce. We further recommend quantifying the value of information for each decision to identify decisions that would benefit most from model input.

60 APPLIED LIFE SCIENCES↗

Grassland Bird Distribution and Raptor Flight Patterns in the Competitive Renewable Energy Zones of the Texas Panhandle [Thesis]

The consistent wind resource in the Great Plains of North America has encouraged the development of wind energy facilities across this region. In the Texas Panhandle, a high quality wind resource is only one factor that has led to the expansion of wind energy development. Other factors include federal tax incentives and the availability of subsidies. Moreover, the State Renewable Portfolio Standards (RPS), mandating production of 10,000 mega-watts of renewable energy in the state by 2025, has contributed to an amicable regulatory and permitting environment (State Energy Conservation Office 2010). Considering the current rate of development, the RPS will be met in coming years (American Wind Energy Association 2011) and the rate of development is likely to continue. To meet increased energy demands in the face of a chronically constrained transmission grid, Texas has developed a comprehensive plan that organizes and prioritizes new transmission systems in high quality wind resource areas called Competitive Renewable Energy Zones (CREZ). The CREZ plan provides developers a solution to transmission constraints and unlocks large areas of undeveloped wind resource areas. In the northern Texas panhandle, there are two CREZs that are classified Class 3 wind (Class 5 is the highest) and range from 862,725 to 1,772,328 ha in size (Public Utility Commission of Texas 2008). Grassland bird populations have declined more than any other bird group in North America (Peterjohn and Sauer 1999, Sauer et al. 2004). Loss of grassland habitat from agricultural development has been the greatest contributor to the decline of grassland bird populations, but development of non-renewable (i.e., oil, coal, and gas) and renewable energy (i.e., wind, solar, biomass, and geothermal) sources have contributed to the decline as well (Pimentel et al. 2002, Maybe and Paul 2007). The effects of wind energy development on declining grassland bird populations has become an area of extensive research, as we attempt to understand and minimize potential impacts of a growing energy sector on declining bird populations. Based on data from post-construction fatality surveys, two grassland bird groups have been the specific focus of research, passerines (songbird guild) and raptors (birds of prey). The effects of wind energy development on these two groups of birds, both of conservation concern, have been examined over the last decade. The primary focus of this research has been on mortality resulting from collision with wind turbines (Kuvlesky et al. 2007). Most studies just quantify post-construction fatality levels (e.g., Erickson et al. 2002) while very few studies provide a comparison of bird populations prior to development through a Before-After-Control-Impact (BACI) study design. Before-After-Control-Impact studies provide powerful evidence of avian/wind energy relationships (Anderson et al. 1999). Despite repeated urgency on conducting these types of studies (Anderson et al. 1999, Madders and Whitfield 2006, Kuvelsky et al. 2007), few have been conducted in North America. Although several European researchers (Larsson 1994, de Lucas et al. 2007) have used BACI designs to examine whether wind facilities modified raptor behavior, there is a scarcity of BACI data relating to North America grassland ecosystems that examine avian-wind energy relationships. There are less than a handful of studies in the entire United States, let alone the southern short grass prairie ecosystem, that incorporate preconstruction data to form the baseline for post-construction impact estimates (Johnson et al. 2000, Erickson et al. 2002). Although declines in grassland bird populations are well-documented (Peterjohn and Sauer 1999, Sauer et al. 2004), the causal mechanisms affecting the decline of grassland birds with increasing wind energy development in the southern short grass prairie are not well-understood (Kuvlesky et al. 2007, Maybe and Paul 2007). Several factors may potentially affect the bird population when wind turbines are constructed in areas with high bird densities (de Lucas et al. 2007). Habitat fragmentation, noise from turbines, physical movement of turbine blades, and increased vehicle traffic have been suggested as causes of decreased density of nesting grassland birds in Minnesota (Leddy et al. 1999), Oklahoma (O’Connell and Piorkowski 2006), and South Dakota (Shaffer and Johnson 2008). Similarly, constructing turbines in areas where bird flight patterns place them at similar heights of turbine blades increases the potential for bird collisions (Johnson et al. 2000, Hoover 2002). Raptor fatalities have been associated with topographic features such as ridges, saddles and rims where birds use updrafts from prevailing winds (Erickson et al. 2000, Johnson et al. 2000, Barrios and Rodriquez 2004, Hoover and Morrison 2005). Thus, wind energy development can result in indirect (e.g., habitat avoidance, decreased nest success) and direct (e.g., collision fatalities) impacts to bird populations (Anderson et al. 1999). Directly quantifying the level of potential impacts (e.g., estimated fatalities/mega-watthour) from wind energy development is beyond the scope of this study. Instead, I aim to quantify density, occupancy and flight behavior for the two bird groups mentioned earlier: obligate grassland songbirds and raptors, respectively, predict where impacts may occur, and provide management recommendations to minimize potential impacts. The United States Department of Energy (DOE), through the Office of Energy Efficiency and Renewable Energy Allocation, contracted Texas Tech University to investigate grassland bird patterns of occurrence in the anticipated CREZ in support of DOE’s 20% Wind Energy by 2030 initiative. In cooperation with Iberdrola Renewables, Inc., studies initiated by Wulff (2010) at Texas Tech University were continued at an area proposed for wind energy development and a separate reference site unassociated with wind energy development. I focused on four primary objectives and this thesis is accordingly organized in four separate chapters that address grassland bird density, grassland bird occupancy, raptor flight patterns, and finally I summarize species diversity and composition. The following chapters use formatting from the Journal of Wildlife Management guidelines (Block et al. 2011) with modifications as required by the Texas Tech University Graduate School. 1) I estimate pre-construction bird density patterns using methods that adjust for imperfect detection. I used a distance sampling protocol that effectively accounts for incomplete detection in the field where birds are present but not detected (Buckland et al. 2001). I improved density estimates with hierarchical distance sampling models, a modeling technique that effectively incorporates the detection process with environmental covariates that further influence bird density (Royle et al. 2004, Royle and Dorazio 2008). Covariates included road density and current oil and gas infrastructure to determine the relationship between existing energy development and bird density patterns. Further, I used remote sensing techniques and vegetation field data to investigate how landcover characteristics influenced bird density patterns. I focused species-specific analyses on obligate grassland birds with >70 detections per season namely grasshopper sparrow (Ammodramus savannarum) and horned lark (Eremophila alpestris). Chapter II focuses on hierarchical models that model and describe relationships between grassland bird density and anthropogenic and landscape features. 2) A large number of bird detections (>70) are needed to estimate density using distance sampling and collection of such quantity are often not feasible, particularly for cryptic species or species that naturally occur at low densities (Buckland et al. 2001). Occupancy models operate with far fewer data and are often used as a surrogate for bird abundance when there are fewer detections (MacKenzie and Nichols 2004). I used occupancy models that allow for the possibility of imperfect detection and species abundance to improve estimates of occurrence probability (Royal 2004). I focused species-specific analyses on grassland birds with few detections: Cassin’s sparrow (Peucaea cassinii), eastern meadowlark (Sturnella magna), and upland sandpiper (Bartramia longicauda). Chapter III uses a multi-season dynamic site occupancy model that incorporates bird abundance to better estimate occurrence probability. 3) When I considered the topographic relief of the study sites, the proposed design of the wind facility and its location within the central U.S. migratory corridor, I expanded the study to investigate raptor abundance and flight behavior (Hoover 2002, Miller 2008). I developed a new survey technique that improved the accuracy of raptor flight height estimates and compared seasonal counts and flight heights at the plateau rim and areas further inland. I used counts and flight behaviors to calculate species-specific collision risk indices for raptors based on topographic features. I focused species-specific analyses on raptors with the highest counts: American kestrel (Falco sparverius), northern harrier (Circus cyaneus), red-tailed hawk (Buteo jamaicensis), Swainson’s hawk (Buteo swainsoni), and turkey vulture (Cathartes aura). Chapter IV describes patterns of seasonal raptor abundance and flight behavior and how topography modulates collision risk with proposed wind energy turbines. 4) Finally, for completeness, in Chapter V I summarize morning point count data for all species and provide estimates of relative composition and species diversity with the Shannon-Wiener Diversity Index (Shannon and Weaver 1949).

17 WIND ENERGY↗

Spinning Reserve From Hotel Load Response: Initial Progress

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

National Security Science and Technology Initiative: Air Cargo Screening

The non-intrusive inspection (NII) of consolidated air cargo carried on commercial passenger aircraft continues to be a technically challenging, high-priority requirement of the Department of Homeland Security's Science and Technology Directorate (DHS S&T), the Transportation Security Agency and the Federal Aviation Administration. The goal of deploying a screening system that can reliably and cost-effectively detect explosive threats in consolidated cargo without adversely affecting the flow of commerce will require significant technical advances that will take years to develop. To address this critical National Security need, the Battelle Memorial Institute (Battelle), under a Cooperative Research and Development Agreement (CRADA) with four of its associated US Department of Energy (DOE) National Laboratories (Oak Ridge, Pacific Northwest, Idaho, and Brookhaven), conducted a research and development initiative focused on identifying, evaluating, and integrating technologies for screening consolidated air cargo for the presence of explosive threats. Battelle invested $8.5M of internal research and development funds during fiscal years 2007 through 2009. The primary results of this effort are described in this document and can be summarized as follows: (1) Completed a gap analysis that identified threat signatures and observables, candidate technologies for detection, their current state of development, and provided recommendations for improvements to meet air cargo screening requirements. (2) Defined a Commodity/Threat/Detection matrix that focuses modeling and experimental efforts, identifies technology gaps and game-changing opportunities, and provides a means of summarizing current and emerging capabilities. (3) Defined key properties (e.g., elemental composition, average density, effective atomic weight) for basic commodity and explosive benchmarks, developed virtual models of the physical distributions (pallets) of three commodity types and three explosive benchmarks combinations, and conducted modeling and simulation studies to begin populating the matrix of commodities, threats, and detection technologies. (4) Designed and fabricated basic (homogeneous) commodity test pallets and fabricated inert stimulants to support experiments and to validate modeling/simulation results. (5) Developed/expanded the team's capabilities to conduct full-scale imaging (neutron and x-ray) experiments of air cargo commodities and explosive benchmarks. (6) Conducted experiments to improve the collection of trace particles of explosives from a variety of surfaces representative of air cargo materials by means of mechanical (air/vibration/pressure), thermal, and electrostatic methods. Air cargo screening is a difficult challenge that will require significant investment in both research and development to find a suitable solution to ensure the safety of passengers without significantly hindering the flow of commodities. The initiative funded by Battelle has positioned this group to make major contributions in meeting the air cargo challenge by developing collaborations, developing laboratory test systems, improving knowledge of the challenges (both technical and business) for air cargo screening, and increasing the understanding of the capabilities for current inspection methods (x-ray radiography, x-ray backscatter, etc.) and potential future inspection methods (neutron radiography, fusion of detector modalities, advanced trace detection, etc.). Lastly, air cargo screening is still an issue that will benefit from collaboration between Department of Energy Laboratories and Battelle. On January 7, 2010, DHS Secretary Napolitano joined White House Press Secretary Robert Gibbs and Assistant to the President for Counterterrorism and Homeland Security John Brennan to announce several recommendations DHS has made to the President for improving the technology and procedures used to protect air travel from acts of terrorism. (This announcement followed the 25 Dec'09 Delta/Northwest Airlines Flight 253 terror attack.) Secretary Napolitano outlined five recommendations DHS will pursue to enhance the safety of the traveling public. One of the five recommendations, read as follows: 'Establish a partnership on aviation security between DHS and the Department of Energy and its National Laboratories in order to develop new and more effective technologies to deter and disrupt known threats and proactively anticipate and protect against new ways by which terrorists could seek to board an aircraft.' In conclusion, it appears very timely that Battelle and its DOE lab partners initiated a serious collaboration on the air cargo topic, and that we should continue to work toward future collaboration in response to the government's needs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

U.S. Nuclear Regulatory Commission Historical Perspectives of Very Low-Level Radioactive Waste - 18367

The United States Nuclear Regulatory Commission (NRC), in Title 10 of the Code of Federal Regulations Part 61 (10 CFR Part 61), 'Licensing Requirements for Land Disposal of Radioactive Waste', provides licensing procedures, performance objectives, and technical requirements for the issuance of licenses for the land disposal of low-level radioactive waste. Low-level radioactive waste is divided into four categories based on its potential risk and need for isolation. Class A is the lowest category of low-level radioactive waste and poses the least risk. A large percentage of Class A low-level waste contains very low radionuclide concentrations and does not pose a significant health and safety risk. In the current regulatory framework, this waste, referred to as low-activity or very low-level waste, is managed in the same manner as much more hazardous waste. In 1986 and 1990, as a result of the Low-Level Radioactive Waste Policy Amendments Act of 1985, the NRC issued the Below Regulatory Concern (BRC) policy statement. This policy statement established an implementation plan regarding the expeditious handling of rulemaking petitions 'to exempt specific radioactive waste streams from regulation due to the presence of radionuclides in sufficiently low concentrations or quantities as to be below regulatory concern.' The BRC policy statement provided a consistent risk framework when considering regulatory exemption decisions, such as: (1) the release for unrestricted public use of lands and structures containing residual radioactivity; (2) the distribution of consumer products containing small amounts of radioactive material; (3) the disposal of very low-level radioactive waste at other than licensed disposal sites; and (4) the recycling of slightly contaminated equipment and materials. Due to concerns with the BRC policy that were raised by Congress, the States, the public, and others, Congress enacted the Energy Policy Act of 1992, which revoked the NRC's 1986 and 1990 BRC policy statements and led to the NRC's formal withdrawal of the BRC policy in 1993. Stakeholders raised concerns on NRC's potential deregulation of radioactive material. Additionally, in March 2005, the NRC staff proposed a rule to amend 10 CFR Part 20, 'Standards for Protection Against Radiation,' to include radiological criteria for controlling the disposition of solid materials with very small amounts of residual radioactivity. The NRC staff also proposed a limited disposition approach for the disposition of solid material, limiting the release of solid material meeting a 0.01 milli-Sievert per year (mSv/yr) [1 milli-rem (mrem/yr)] dose criterion, from licensed control. In June 2005, the Commission disapproved publication of the proposed rule and deferred the rulemaking until a later time, stating that the NRC's existing approach of reviewing specific cases on an individual basis was fully protective of public health and safety. This rulemaking effort was discontinued by the Commission in 2016. Recently, several nuclear power plant licensees have announced early decommissioning of their facilities. Some stakeholders have expressed concerns about the capacity and disposal costs associated with using the four existing low-level waste disposal sites for very low levels of radioactive waste (i.e., waste at the low end of the Class A category). A more risk-informed, performance based approach to waste disposal would allow more flexibility in managing this waste commensurate with its risk and hazard. A new approach would also allow the NRC to align with international standards for this type of waste. The NRC is presently conducting a scoping study to identify the actions the agency should take to strengthen its regulatory framework for very low-level waste disposal. The Very Low-Level Waste (VLLW) scoping study will consider divergent stakeholder comments; lessons learned from the BRC policy statements and the proposed rule on radiological criteria for controlling the disposition of solid materials; and best practices of other countries with respect to VLLW disposal. The NRC will also engage other government agencies to discuss regulatory options for VLLW. This paper offers a historical overview of past NRC initiatives to manage the lower end of Class A waste in a manner that is risk informed and performance based. It examines previous endeavors and discusses the regulatory challenges that arose. It also addresses lessons learned and introduces NRC's current effort regarding very low-level radioactive waste disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗