Pilot Implementation of a Field Study Design to Evaluate the Impact of Source Control Measures on Indoor Air Quality in High Performance Homes

To improve the indoor air quality in new, high performance homes, a variety of standards and rating programs have been introduced to identify building materials that are designed to have lower emission rates of key contaminants of concern and a number of building materials are being introduced that are certified to these standards. For example, the U.S. Department of Energy (DOE) Zero Energy Ready Home program requires certification under the U.S. Environmental Protection Agency (EPA) Indoor airPLUS (IaP) label, which requires the use of PS1 or PS2 certified plywood and OSB; low-formaldehyde emitting wood products; low- or no-VOC paints and coatings as certified by Green Seal Standard GS-11, GreenGuard, SCS Indoor Advantage Gold Standard, MPI Green Performance Standard, or another third party rating program; and Green Label-certified carpet and carpet cushions. However, little is known regarding the efficacy of the IAP requirements in measurably reducing contaminant exposures in homes. The goal of this project is to develop a robust experimental approach and collect preliminary data to support the evaluation of indoor air quality (IAQ) measures linked to IAP-approved low-emitting materials and finishes in new residential homes. To this end, the research team of Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) developed a detailed experimental plan to measure IAQ constituents and other parameters, over time, in new homes constructed with materials compliant with IAP’s low-emitting material and ventilation requirements (i.e., section 6.1, 6.2, 6.3, and 7.2) and similar homes constructed to the state building code with conventional materials. The IAQ in IAP and conventional homes of similar age, location, and construction style is quantified as the differences in the speciated VOC and aldehyde concentrations, normalized to dilution rates. The experimental plan consists of methods to evaluate the difference between low-emitting and “conventional” materials as installed in newly constructed residential homes using both (1) highly controlled, short-term active samples to precisely characterize the building-related chemical emissions and building contents and (2) a week-long passive sample designed to capture the impact of occupant behavior and related activities on measured IAQ contaminant levels indoors. The combination of detailed short-term measurements with the home under controlled/consistent conditions during pre- and post-occupancy and the week-long passive sampling data provide the opportunity to begin to separate the different emission sources and help isolate and quantify variability in the monitored homes. Between April and August 2014, the research team performed pre-occupancy and post-occupancy sampling in one conventional home and two homes built with low-emitting materials that were generally consistent with EPA’s Indoor airPLUS guidelines. However, for a number of reasons, the full experimental plan was not implemented. The project was intended to continue for up to three years to asses long-term changes in IAQ but the project was limited to one calendar year. As a result, several of the primary research questions related to seasonal impacts and the long-term trends in IAQ could not be addressed. In addition, there were several unexpected issues related to recruiting, availability of home types, and difficulty coordinating with builders/realtors/homeowners. Several field monitoring issues also came up that provide “lessons learned” that led to improvements to the original monitoring plan. The project produced a good experimental plan that is expected to be be useful for future efforts collecting data to support answering these same or similar research questions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Annual Energy Savings and Thermal Comfort of Autonomously Heated and Cooled Office Chairs

Energy use in offices buildings is largely driven by air conditioning demands. But the optimal temperature is not the same for all building occupants, leading to the infamous thermostat war. And many occupants have independently overcome building comfort weaknesses with their own space heaters or fans. NREL tested is a customized office chair that automatically heats and cools the occupant along the seat and chair back according to the occupants' personal preferences. This product is shown to deliver markedly better comfort at room temperatures well above typical office cooling setpoints. Experimental subjects reported satisfaction in these elevated air temperatures, partly because the chair's cooling effect was tuned to their own individual needs. Simulation of the chair in office buildings around the U.S. shows that energy can be saved everywhere, with impacts varying due to the climate. Total building HVAC energy savings exceeded 10% in hot-dry climate zones. Due to high product cost, simple payback for the chair we studied is beyond the expected chair life. We then understood the need to establish cost-performance targets for comfort delivery packages. NREL derived several hypothetical energy/cost/comfort targets for personal comfort product systems. In some climate regions around the U.S., these show the potential for office building HVAC energy savings in excess of 20%. This report documents this research, providing an overview of the research team's methods and results while also identifying areas for future research building upon the findings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

User Location-Specific Data for Smarter Smart Grids

This project focused on modifying and evaluating the Readings at Desk (RAD) controller, a lighting control system developed and patented by Erik Page & Associates, Inc. (EP&A) that: 1) Measures the amount of light present in the workstation; 2) Allows occupants to define desired light levels at the workstation; 3) Communicates to wirelessly-controllable overhead lighting systems. In measuring conditions at the desk, the RAD controller differs from typical lighting control systems that rely on daylight sensors located at the ceiling. There are inherent advantages associated with using sensors that are located at the occupant’s workstation in that they more accurately represent what the occupant is experiencing, theoretically providing a much better closed-loop control point. The technical objectives of this Phase I project were: 1) Objective 1: Modify the RAD controller such that it can report energy use of connected devices and receive status updates and/or commands from external sources, such as grid or demand response signals. 2) Objective 2: Modify the RAD controller to measure the temperature at a workstation, accept temperature preferences from users, and communicate controls information to a building’s HVAC systems. 3) Objective 3: Carry out a comprehensive performance test of the modified RAD controller in controlling lighting and HVAC systems. All three technical objectives were met in the Phase I project execution, as well as an additional “bonus” technical achievement not described in the original proposal: the development of a computer monitor-mounted occupancy and lighting sensor board.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-Zone Solar Control Indoor Shade: Demonstration at the Ronald V. Dellums Federal Building and U.S. Courthouse, 1301 Clay Street, Oakland, California and the Lawrence Berkeley National Laboratory Advanced Windows Testbed, Berkeley, California

Standard window shades are used to control sunlight, glare, window heat gains, and daylight. The challenge with conventional shades is that once the shades are lowered to reduce discomfort, daylight is reduced, which, in turn, increases the need for electric lighting. View is also obstructed, reducing the occupants’ connection to the outdoors. The strategy of subdividing the window wall and admitting daylight from above and controlling sunlight and view through the lower aperture can yield significant energy and peak demand savings over conventional shading systems, and improve the daylight quality of the indoor environment. This study evaluated a dual zone solar control (DZSC) shade with an upper, automated, horizontal, venetian blind with concave-up, matte white slats and a lower, manually operated, roller shade made of a transparent, reflective film. The automatic controls were designed to adjust the upper slat angle to maximize daylight to the room interior. The lower shade, when lowered, provided an unobstructed view to the outdoors. For the qualitative analysis, the DZSC shades were installed on windows in the southeast half of one floor in the Ronald V. Dellums Federal Building and U.S. Courthouse or hereafter referred to as the Oakland Federal Building (OFB) in Oakland, California. The position of the DZSC shades were observed and recorded periodically. Surveys were issued to occupants in the private offices and open plan workstations affected by the shades. For the quantitative analysis, the DZSC shades were installed in the south-facing windows of thermally isolated, fully instrumented, test chambers in the Advanced Windows Testbed at the Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California. Measurements of window heat loads, daylight illuminance and environmental conditions related to visual and thermal comfort were collected over a six-month, solstice-to-solstice period. The performance of the DZSC shade was compared to fabric roller shades and venetian blinds since these are the two most common types of shades used in both commercial and Federal buildings. Several DZSC design permutations were evaluated: 1) manual or automated control of the upper louver system (“man” or “auto”) and 2) tinted or silvered reflective film for the lower shade (“Gray-Gray (GG)” or “Gray-Silver (GS)”1). The automated, reflective shade (auto-GS) reduced dimmable fluorescent lighting energy use by 51% and window cooling load by 13-15% compared to a conventional fabric roller shade with dual-pane, spectrally selective, low-e windows during the summer period (winter period was not measured). Qualitative analysis revealed that the auto-GS shade was preferred by 80% of the survey respondents compared to the existing vertical fabric blinds with single-pane, tinted windows in the occupied building. Survey results indicated that visual discomfort was reduced and thermal discomfort was also reduced during warm or hot weather. Occupants expressed greater satisfaction with the unobstructed view. Installation and commissioning of the DZSC shades was fairly straightforward with some minor problems due to inadequate installation instructions and improper wiring. A few occupants expressed dissatisfaction with the automatic controls for the upper louvers due to visual discomfort, erroneous control, and motor noise.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dose Modeling for Harborview Research and Training Facility

The Harborview Research and Training (R&T) Facility at the University of Washington (UW) was accidently contaminated from a breached sealed source of Cesium-137. The release occurred during removal of the sealed source from its holder within a portable hot cell in the loading dock area near room 220. The loading dock and northeast corner of the building above the ground floor were impacted by the release, whereas the remaining portions of the R&T Facility were minimally affected. Detailed descriptions of the R&T Facility and the affected area/rooms are included in Section 2. The RESRAD Team in the Environmental Science Division of Argonne National Laboratory visited the site on August 12, 2019, and interviewed the R&T Facility building manager and staff working in the building at that time. Site- and building-specific data were collected including building floor plan CAD drawings, building occupants’ working hours, contaminated rooms photos and their dimensions, building air exchange rates, building materials and “curtain wall” details, and so forth. These data are being used in the dose modeling for potential occupants of the building after it is remediated. The dose modeling was performed using the RESRAD-BUILD computer code, which is designed for the evaluation of radiologically contaminated buildings (Yu et al. 2003). Two hypothetical building occupants of the Harborview R&T Facility were evaluated: a researcher occupying room 726 (a research laboratory on the seventh floor) and a custodian occupying room 220 (loading dock and trash compactor room with a rollup door). A maintenance worker that will be spending less time in impacted areas was not modeled because it will be bounded by other two hypothetical building occupants modeled. A summary description of the RESRAD-BUILD is provided in Appendix A, and the modeling of potential doses to a researcher and a custodian is described in detail in Section 3. A summary and a discussion of the dose modeling results are included in Section 4. The parameters used in the RESRAD-BUILD modeling are included in Appendix B. This report documents the dose modeling results; it does not describe measurements of the actual radioactivity levels at the Harborview R&T Facility, nor does it set any expectation for the actual final radioactivity levels. The radiation doses presented are modeling results based on the generic screening values of Cs-137 and several conservative assumptions and are meant only to assist in decision making regarding decontamination of the Harborview R&T Facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ford Thermoelectric HVAC Project (Final Report)

Current light-duty vehicles provide passenger thermal comfort primarily through the use of a centralized HVAC (Heating, Ventilation, and Air Conditioning) unit that distributes conditioned air to vent locations throughout the vehicle. A substantial portion of the air energy content is spent conditioning various elements of the vehicle's interior structures. This is not an overwhelming issue in today’s vehicles, but as pressure builds to improve powertrain efficiency, the energy available to provide occupant comfort will decrease. Thermoelectric devices were identified by the US Department of Energy as one method to potentially reduce HVAC-related energy consumption in vehicles. The objective of the Ford Thermoelectric HVAC Project was to identify a technical and business approach to accelerate research and development of light-duty automotive thermoelectric HVAC technology. A zonal HVAC system was developed to provide thermal comfort to each occupant, with the objective of reducing the overall power consumed by the HVAC system compared with a baseline system. The system was designed to provide a basis for a down-sized central HVAC unit, while providing equivalent comfort and equivalent heating/cooling time-to-comfort at startup, and reduce the energy consumed to provide these functions. Project success was evaluated using occupant comfort and energy consumption metrics, based on a novel thermal comfort-modeling approach, and empirical testing. The ability to produce and market the thermoelectric devices developed in this program was assessed by a business analysis that outlined key steps required for thermoelectric HVAC devices to come to market. Key hardware and controls attribute requirements were identified to determine how they contribute to the commercialization potential of the technology. Final testing and analysis showed that use of thermal comfort and zonal design criteria reduced the energy consumption of the climate control system in both heating and cooling tests, and were significantly better in low vehicle occupancy cases where zonal strategies could be employed. Thermoelectric devices were utilized in the vehicle design to support achieving the technical performance goals of the project. It was found that these devices need additional development in order to address commercial issues, due to their cost and performance limitations.

99 GENERAL AND MISCELLANEOUS↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

A Case Study of Tunable White LED Lighting with Networked Lighting Controls (Emory University Cognitive Empowerment Program)

Emory University and Georgia Institute of Technology (Georgia Tech) partnered to create the Charlie and Harriet Schaffer Cognitive Empowerment Program (CEP) facility in northeast Atlanta. Together with the funders they are building a program to help individuals experiencing mild cognitive impairment (MCI) to maintain their physical and cognitive health, and independence as long as possible. In addition to applying effective strategies and therapies, the two research groups are investigating the responses of the MCI members to treatments that involve acoustical conditions, exercise and movement, and lighting changes that may support retention or relearning of skills. Care partners and family members receive support and instruction to improve home and work life, promoting joy, purpose, and wellness in the family groups. The lighting system uses tunable-white LEDs, employing luminaires with both warm and cool-color emitters that can be dimmed separately to produce any white correlated color temperature (CCT) between 2700 K and 6500 K. All luminaires were dimmable to achieve subdued or lively surroundings for different treatments, time-of-day, and mood. A central networked digital control system was employed to allow tuning of multiple spaces together (for example, bright, cool morning light could be programmed for extra stimulation, or lighting in all spaces at the end of the day could be reduced in both light output and CCT to promote relaxation and not interfere with the melatonin cycle of occupants). Almost all spaces were equipped with individual room control of dimming and color temperature with touch screens to allow users to tune the lighting as desired, but each room’s controls could also be specially programmed through the server in case the research staff were investigating lighting settings on learning, for example. The server incorporates a timeclock, and it is able to send signals to switch off all lighting after occupancy hours, or enable occupancy sensors to control the lighting. The bulk of the construction work was completed in January 2020. It was clear from an initial walk-through that although the lighting system produced the expected high light level with low-glare qualities of light, that there were issues and inconsistencies to be resolved. These were noted in an initial punchlist visit and expected to be resolved when the tech representatives from the agency visited with the electrical contractor in the following few weeks. What followed was 2.5 years of identifying unexpected lighting performance in terms of light output, color, scheduling, and occupancy. This report documents the issues encountered in the effort to get the lighting and controls systems to operate as intended. It concludes with guidance for design professionals and manufacturers to help avoid problematic complexity in future projects.

42 ENGINEERING↗

Infrared-Fused Vision-Based Thermoregulation Performance Estimation for Personal Thermal Comfort-Driven HVAC System Controls

Thermal comfort is one of the primary factors influencing occupant health, well-being, and productivity in buildings. Existing thermal comfort systems require occupants to frequently communicate their comfort vote via a survey which is impractical as a long-term solution. Here, we present a novel thermal infrared-fused computer vision sensing method to capture thermoregulation performance in a non-intrusive and non-invasive manner. In this method, we align thermal and visible images, detect facial segments (i.e., nose, eyes, face boundary), and accordingly read the temperatures from the appropriate coordinates in the thermal image. We focus on the human face since it is often clearly visible to cameras and is not merged into a hot background (unlike hands). We use a regularized Gaussian Mixture model to track the thermoregulation changes over time and apply a heuristic algorithm to extract hot and cold indices. We present a personalized and a generalized comfort modeling method, selected based on the availability of the occupant historical indices measurements in a neutral environment, and use the time-series of the hot and cold indices to define corrections to HVAC system operations in the form of setpoint constraints. To evaluate the efficacy of our proposed approach in responding to thermal stimuli, we designed a series of controlled experiments to simulate exposure to cold and hot environments. While applying personalized modeling showed an acceptable average accuracy of 91.3%, the generalized model’s average accuracy was only 65.2%. This shows the importance of having access to physiological records in modeling and assessing comfort. We also found that individual differences should be considered in selecting the cooling and heating rates when some knowledge of the occupant’s overall thermal preference is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studying Response to Light in Offices: A Literature Review and Pilot Study

Researchers have been exploring the influence of light on health in office settings for over two decades; however, a greater understanding of physiological responses and technology advancements are shifting the way researchers study the influence of light in realistic environments. New technologies paired with Ecological Momentary Assessments (EMAs) administered via smartphones provide ways to collect information about individual light exposure and occupant response throughout the day. The study aims to document occupant response to tunable lighting in a real office environment, including potential beneficial or adverse health and well-being effects. Twenty-three office employees agreed to participate in a twelve-week study examining occupant response to two lighting conditions (static vs. dynamic). No significant differences were observed for any of the measures, highlighting the importance and complexity of in-situ studies conducted in realistic environments. While prior office studies have shown a significant influence on daytime sleepiness and sleep quality, research has not shown mood or stress to be significantly impacted by lighting conditions. Correlation analyses regarding lighting satisfaction, environmental satisfaction, and visual comfort demonstrate a significant relationship between certain items that may inform future studies. Further, the high correlation means it is reasonable to assume that many environmental factors in offices can influence occupant behavior and well-being.

60 APPLIED LIFE SCIENCES↗

Site Identity and Importance in Cosubstituted Bixbyite In2O3

The bixbyite structure of In2O3 has two nonequivalent, 6-coordinate cation sites and, when Sn is doped into In2O3, the Sn prefers the “b-site” and produces a highly conductive material. When divalent/tetravalent cation pairs are cosubstituted into In2O3, however, the conductivity increases to a lesser extent and the site occupancy is less understood. We examine the site occupancy in the MgxIn2−2xSnxO3 and ZnxIn2−2xSnxO3 systems with high resolution X-ray and neutron diffraction and density functional theory computations, respectively. In these sample cases and those that are previously reported in the MxIn2−2xSnxO3 (M = Cu, Ni, or Zn) systems, the solubility limit is greater than 25%, ensuring that the b-site cannot be the exclusively preferred site as it is in Sn:In2O3. Prior to this saturation point, we report that the M2+ cation always has at least a partial occupancy on the d-site and the Sn4+ cation has at least a partial occupancy on the b-site. The energies of formation for these configurations are highly favored, and prefer that the divalent and tetravalent substitutes are adjacent in the crystal lattice, which suggests short range ordering. Diffuse reflectance and 4-point probe measurements of MgxIn2−xSnxO3 demonstrate that it can maintain an optical band gap >2.8 eV while surpassing 1000 S/cm in conductivity. Understanding how multiple constituents occupy the two nonequivalent cation sites can provide information on how to optimize cosubstituted systems to increase Sn solubility while maintaining its dopant nature, achieving maximum conductivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-Haul Truck Sleeper Heating Load Reduction Package for Rest Period Idling

Annual fuel use for sleeper cab truck rest period idling is estimated at 667 million gallons in the United States, or 6.8% of long-haul truck fuel use. Truck idling during a rest period represents zero freight efficiency and is largely done to supply accessory power for climate conditioning of the cab. The National Renewable Energy Laboratory's CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck thermal management systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In addition, if the fuel savings provide a one- to three-year payback period, fleet owners will be economically motivated to incorporate them. For candidate idle reduction technologies to be implemented by original equipment manufacturers and fleets, their effectiveness must be quantified. To address this need, several promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. Load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, conductive pathways, and efficient equipment. Technologies in each of these focus areas were investigated in collaboration with industry partners. The most promising of these technologies were then combined with the goal of exceeding a 30% reduction in HVAC loads. These technologies included 'ultra-white' paint, advanced insulation, and advanced curtain design. Previous testing showed more than a 35.7% reduction in air conditioning loads. This paper describes the overall heat transfer coefficient testing of this advanced load reduction technology package that showed more than a 43% reduction in heating load. Adding an additional layer of advanced insulation with a reflective barrier to the thermal load reduction package resulted in a 53.3% reduction in the overall heat transfer coefficient.

30 DIRECT ENERGY CONVERSION↗

Review of Qualitative Approaches for the Construction Industry: Designing a Risk Management Toolbox

Objectives: This paper presents the framework and protocol design for a construction industry risk management toolbox. The construction industry needs a comprehensive, systematic approach to assess and control occupational risks. These risks span several professional health and safety disciplines, emphasized by multiple international occupational research agenda projects including: falls, electrocution, noise, silica, welding fumes, and musculoskeletal disorders. Yet, the International Social Security Association says, “whereas progress has been made in safety and health, the construction industry is still a high risk sector.” Methods: Small- and medium-sized enterprises (SMEs) employ about 80% of the world’s construction workers. In recent years a strategy for qualitative occupational risk management, known as Control Banding (CB) has gained international attention as a simplified approach for reducing work-related risks. CB groups hazards into stratified risk ‘bands’, identifying commensurate controls to reduce the level of risk and promote worker health and safety. We review these qualitative solutions-based approaches and identify strengths and weaknesses toward designing a simplified CB ‘toolbox’ approach for use by SMEs in construction trades. Results: This toolbox design proposal includes international input on multidisciplinary approaches for performing a qualitative risk assessment determining a risk ‘band’ for a given project. Risk bands are used to identify the appropriate level of training to oversee construction work, leading to commensurate and appropriate control methods to perform the work safely. Conclusion: The Construction Toolbox presents a review-generated format to harness multiple solutions-based national programs and publications for controlling construction-related risks with simplified approaches across the occupational safety, health and hygiene professions.

60 APPLIED LIFE SCIENCES↗

Microcomputer based software for biodynamic simulation

This paper presents a description of a microcomputer based software package, called DYNAMAN, which has been developed to allow an analyst to simulate the dynamics of a system consisting of a number of mass segments linked by joints. One primary application is in predicting the motion of a human occupant in a vehicle under the influence of a variety of external forces, specially those generated during a crash event. Extensive use of a graphical user interface has been made to aid the user in setting up the input data for the simulation and in viewing the results from the simulation. Among its many applications, it has been successfully used in the prototype design of a moving seat that aids in occupant protection during a crash, by aircraft designers in evaluating occupant injury in airplane crashes, and by users in accident reconstruction for reconstructing the motion of the occupant and correlating the impacts with observed injuries.

Rangarajan, N.↗

Comprehensive Environmental Informatics System (CEIS) Integrating Crew and Vehicle Environmental Health

Integrated Vehicle Health Management (IVHM) systems have been pursued as highly integrated systems that include smart sensors, diagnostic and prognostics software for assessments of real-time and life-cycle vehicle health information. Inclusive to such a system is the requirement to monitor the environmental health within the vehicle and the occupants of the vehicle. In this regard an enterprise approach to informatics is used to develop a methodology entitled, Comprehensive Environmental Informatics System (CEIS). The hardware and software technologies integrated into this system will be embedded in the vehicle subsystems, and maintenance operations, to provide both real-time and life-cycle health information of the environment within the vehicle cabin and of its occupants. This comprehensive information database will enable informed decision making and logistics management. One key element of the CEIS is interoperability for data acquisition and archive between environment and human system monitoring. With comprehensive components the data acquired in this system will use model based reasoning systems for subsystem and system level managers, advanced on-board and ground-based mission and maintenance planners to assess system functionality. Knowledge databases of the vehicle health state will be continuously updated and reported for critical failure modes, and routinely updated and reported for life cycle condition trending. Sufficient intelligence, including evidence-based engineering practices which are analogous to evidencebased medicine practices, will be included in the CEIS to result in more rapid recognition of off-nominal operation to enable quicker corrective actions. This will result from better information (rather than just data) for improved crew/operator situational awareness, which will produce significant vehicle and crew safety improvements, as well as increasing the chance for mission success, future mission planning as well as training. Other benefits include improved reliability, increase safety in operations and cost of operations. The cost benefits stem from significantly reduced processing and operations manpower, predictive maintenance for systems and subjects. The improvements in vehicle functionality and cost will result from increased prognostic and diagnostic capability due to the detailed total human exploration system health knowledge from CEIS. A collateral benefit is that there will be closer observations of the vehicle occupants as wrist watch sized devices are worn for continuous health monitoring. Additional database acquisition will stem from activities in countermeasure practices to ensure peak performance capability by occupants of the vehicle. The CEIS will provide data from advanced sensing technologies and informatics modeling which will be useful in problem troubleshooting, and improving NASA s awareness of systems during operation.

Nall, Mark E.↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x‐acceleration peak response correlated with the human response at 8 and 10‐G 100 ms but not 10‐G 70 ms. The phase lagged the human response. Head z‐acceleration was not correlated. Chest x‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x‐acceleration was not well correlated. Head and chest z‐acceleration was in phase but had a higher peak response. Chest z‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z‐displacement but the THOR was in phase and was comparable to the mean peak response. Head xand z‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, N.↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post-­‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi-­‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two-­‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x-­‐acceleration peak response correlated with the human response at 8 and 10-­‐G 100 ms but not 10-­‐G 70 ms. The phase lagged the human response. Head z-­‐acceleration was not correlated. Chest x-­‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x-­‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x-­‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x-­‐acceleration was not well correlated. Head and chest z-­‐acceleration was in phase but had a higher peak response. Chest z-­‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z-­‐displacement but the THOR was in phase and was comparable to the mean peak response. Head x-­‐ and z-­‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, Nate↗