Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Objectives”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Object detectability at increased ambient lighting conditions

Under typical dark conditions encountered in diagnostic reading rooms, a reader's pupils will contract and dilate as the visual focus intermittently shifts between the high luminance display and the darker background wall, resulting in increased visual fatigue and the degradation of diagnostic performance. A controlled increase of ambient lighting may, however, reduce the severity of these pupillary adjustments by minimizing the difference between the luminance level to which the eyes adapt while viewing an image (L{sub adp}) and the luminance level of diffusely reflected light from the area surrounding the display (L{sub s}). Although ambient lighting in reading rooms has conventionally been kept at a minimum to maintain the perceived contrast of film images, proper Digital Imaging and Communications in Medicine (DICOM) calibration of modern medical-grade liquid crystal displays can compensate for minor lighting increases with very little loss of image contrast. This paper describes two psychophysical studies developed to evaluate and refine optimum reading room ambient lighting conditions through the use of observational tasks intended to simulate real clinical practices. The first study utilized the biologic contrast response of the human visual system to determine a range of representative L{sub adp} values for typical medical images. Readers identified low contrast horizontal objects in circular foregrounds of uniform luminance (5, 12, 20, and 30 cd/m{sup 2}) embedded within digitized mammograms. The second study examined the effect of increased ambient lighting on the detection of subtle objects embedded in circular foregrounds of uniform luminance (5, 12, and 35 cd/m{sup 2}) centered within a constant background of 12 cd/m{sup 2} luminance. The images were displayed under a dark room condition (1 lux) and an increased ambient lighting level (50 lux) such that the luminance level of the diffusely reflected light from the background wall was approximately equal to the image L{sub adp} value of 12 cd/m{sup 2}. Results from the first study demonstrated that observer true positive and false positive detection rates and true positive detection times were considerably better while viewing foregrounds at 12 and 20 cd/m{sup 2} than at the other foreground luminance levels. Results from the second study revealed that under increased room illuminance, the average true positive detection rate improved a statistically significant amount from 39.3% to 55.6% at 5 cd/m{sup 2} foreground luminance. Additionally, the true positive rate increased from 46.4% to 56.6% at 35 cd/m{sup 2} foreground luminance, and decreased slightly from 90.2% to 87.5% at 12 cd/m{sup 2} foreground luminance. False positive rates at all foreground luminance levels remained approximately constant with increased ambient lighting. Furthermore, under increased room illuminance, true positive detection times declined at every foreground luminance level, with the most considerable decrease (approximately 500 ms) at the 5 cd/m{sup 2} foreground luminance. The first study suggests that L{sub adp} of typical mammograms lies between 12 and 20 cd/m{sup 2}, leading to an optimum reading room illuminance of approximately 50-80 lux. Findings from the second study provide psychophysical evidence that ambient lighting may be increased to a level within this range, potentially improving radiologist comfort, without deleterious effects on diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Objective index of image fidelity for JPEG2000 compressed body CT images

Compression ratio (CR) has been the de facto standard index of compression level for medical images. The aim of the study is to evaluate the CR, peak signal-to-noise ratio (PSNR), and a perceptual quality metric (high-dynamic range visual difference predictor HDR-VDP) as objective indices of image fidelity for Joint Photographic Experts Group (JPEG) 2000 compressed body computed tomography (CT) images, from the viewpoint of visually lossless compression approach. A total of 250 body CT images obtained with five different scan protocols (5-mm-thick abdomen, 0.67-mm-thick abdomen, 5-mm-thick lung, 0.67-mm-thick lung, and 5-mm-thick low-dose lung) were compressed to one of five CRs (reversible, 6:1, 8:1, 10:1, and 15:1). The PSNR and HDR-VDP values were calculated for the 250 pairs of the original and compressed images. By alternately displaying an original and its compressed image on the same monitor, five radiologists independently determined if the pair was distinguishable or indistinguishable. The kappa statistic for the interobserver agreement among the five radiologists' responses was 0.70. According to the radiologists' responses, the number of distinguishable image pairs tended to significantly differ among the five scan protocols at 6:1-10:1 compressions (Fisher-Freeman-Halton exact tests). Spearman's correlation coefficients between each of the CR, PSNR, and HDR-VDP and the number of radiologists who responded as distinguishable were 0.72, -0.77, and 0.85, respectively. Using the radiologists' pooled responses as the reference standards, the areas under the receiver-operating-characteristic curves for the CR, PSNR, and HDR-VDP were 0.87, 0.93, and 0.97, respectively, showing significant differences between the CR and PSNR (p=0.04), or HDR-VDP (p<0.001), and between the PSNR and HDR-VDP (p<0.001). In conclusion, the CR is less suitable than the PSNR or HDR-VDP as an objective index of image fidelity for JPEG2000 compressed body CT images. The HDR-VDP is more promising than the PSNR as such an index.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiobiology for eye plaque brachytherapy and evaluation of implant duration and radionuclide choice using an objective function

Purpose: Clinical optimization of Collaborative Ocular Melanoma Study (COMS) eye plaque brachytherapy is currently limited to tumor coverage, consensus prescription dosage, and dose calculations to ocular structures. The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide R and implant duration T. This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position P, prescription dose, R, and T. Methods: Plaque-heterogeneity-corrected dose distributions were generated with MCNP5 for the range of currently available COMS plaques loaded with sources using three available low-energy radionuclides. These physical dose distributions were imported into the PINNACLE{sup 3} treatment planning system using the TG-43 hybrid technique and used to generate dose volume histograms for a T = 7 day implant within a reference eye geometry including the ciliary body, cornea, eyelid, foveola, lacrimal gland, lens, optic disc, optic nerve, retina, and tumor at eight standard treatment positions. The equation of Dale and Jones was employed to create biologically effective dose volume histograms (BEDVHs), allowing for BED volumetric analysis of all ROIs. Isobiologically effective prescription doses were calculated for T = 5 days down to 0.01 days, with BEDVHs subsequently generated for all ROIs using correspondingly reduced prescription doses. Objective functions were created to evaluate the BEDVHs as a function of R and T. These objective functions are mathematically accessible and sufficiently general to be applied to temporary or permanent brachytherapy implants for a variety of disease sites. Results: Reducing T from 7 to 0.01 days for a 10 mm plaque produced an average BED benefit of 26%, 20%, and 17% for {sup 103}Pd, {sup 125}I, and {sup 131}Cs, respectively, for all P; 16 and 22 mm plaque results were more position-dependent. {sup 103}Pd produced a 16%-35% BED benefit over {sup 125}I, whereas {sup 131}Cs produced a 3%-7% BED detriment, independent of P, T, and plaque size. Additionally, corresponding organ at risk physical doses were lowest using {sup 103}Pd in all circumstances. Conclusions: The results suggest that shorter implant durations may correlate with more favorable outcomes compared to 7 day implants when treating small or medium intraocular lesions. The data also indicate that implant duration may be safely reduced if the prescription physical dose is likewise diminished and that {sup 103}Pd offers a substantial radiobiological benefit over {sup 125}I and {sup 131}Cs irrespective of plaque position, implant duration, and tumor size.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-419: Evaluation of PlanIQ Feasibility DVH as Planning Objectives for Skull Base SBRT Patients

Purpose: PlanIQ(Sun Nuclear Corporation) can provide feasibility measures on organs-at-risk(OARs) around the target based on depth, local anatomy density and energy of radiation beam used. This study is to test and evaluate PlanIQ feasibility DVHs as optimization objectives in the treatment planning process, and to investigate the potential to use them in routine clinical cases to improve planning efficiency. Methods: Two to three arcs VMAT Treatment plans were generated in Pinnacle based on PlanIQ feasibility DVH for six skull base patients who previously treated with SBRT. The PlanIQ feasibility DVH for each OAR consists of four zones – impossible (at 100% target coverage), difficult, challenging and probable. Constrains to achieve DVH in difficult zone were used to start plan optimization. Further adjustment was made to improve coverage. The plan DVHs were compared to PlanIQ feasibility DVH to assess the dose received by 0%(D0), 5%(D5), 10%(D10) and 50%(D50) of the OAR volumes. Results: A total of 90 OARs were evaluated for 6 patients (mean 15 OARs, range 11–18 OARs). We used >98% PTV coverage as planning goal since it’s difficult to achieve 100% target coverage. For the generated plans, 96.7% of the OARs achieved D0 or D5 within difficult zone or impossible zone (ipsilateral OARs 93.5%, contralateral OARs 100%), while 90% and 65.6% of the OARs achieved D10 and D50 within difficult zone, respectively. Seventeen of the contralateral and out of field OARs achieved DVHs in impossible zone. For OARs adjacent or overlapped with target volume, the D0 and D5 are challenging to be optimized into difficult zone. All plans were completed within 2–4 adjustments to improve target coverage and uniformity. Conclusion: PlanIQ feasibility tool has the potential to provide difficult but achievable initial optimization objectives and therefore reduce the planning time to obtain a well optimized plan.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-11: Objective Image Characterization of Spectral CT with a Dual-Layer Detector

Purpose: To obtain objective reference data for the spectral performance on a dual-layer detector CT platform (IQon, Philips) and compare virtual monoenergetic to conventional CT images. Methods: Scanning was performed using the hospital’s clinical adult body protocol: helical acquisition at 120kVp, with CTDIvol=15mGy. Multiple modules (591, 515, 528) of a CATPHAN 600 phantom and a 20 cm diameter cylindrical water phantom were scanned. No modifications to the standard protocol were necessary to enable spectral imaging. Both conventional and virtual monoenergetic images were generated from acquired data. Noise characteristics were assessed through Noise Power Spectra (NPS) and pixel standard deviation from water phantom images. Spatial resolution was evaluated using Modulation Transfer Functions (MTF) of a tungsten wire as well as resolution bars. Low-contrast detectability was studied using contrast-to-noise ratio (CNR) of a low contrast object. Results: MTF curves of monoenergetic and conventional images were almost identical. MTF 50%, 10%, and 5% levels for monoenergetic images agreed with conventional images within 0.05lp/cm. These observations were verified by the resolution bars, which were clearly resolved at 7lp/cm but started blurring at 8lp/cm for this protocol in both conventional and 70 keV images. NPS curves indicated that, compared to conventional images, the noise power distribution of 70 keV monoenergetic images is similar (i.e. noise texture is similar) but exhibit a low frequency peak at keVs higher and lower than 70 keV. Standard deviation measurements show monoenergetic images have lower noise except at 40 keV where it is slightly higher. CNR of monoenergetic images is mostly flat across keV values and is superior to that of conventional images. Conclusion: Values for standard image quality metrics are the same or better for monoenergetic images compared to conventional images. Results indicate virtual monoenergetic images can be used without any loss in image quality or noise penalties relative to conventional images. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗

Rapid method for computing the mechanical resonances of irregular objects

A solid object's geometry, density, and elastic moduli completely determine its spectrum of normal modes. Solving the inverse problem—determining a material's elastic moduli given a set of resonance frequencies and sample geometry—relies on the ability to compute resonance spectra accurately and efficiently. Established methods for calculating these spectra are either fast but limited to simple geometries, or are applicable to arbitrarily shaped samples at the cost of being prohibitively slow. Here, we describe a method to rapidly compute the normal modes of irregularly shaped objects using entirely open-source software. Our method's accuracy compares favorably with existing methods for simple geometries and shows a significant improvement in speed over existing methods for irregular geometries.

Acoustics↗

Complex Pupil Masks for Aberrated Imaging of Closely Spaced Objects

Current approach demonstrates the suppression of optical side-lobes and the contraction of the main lobe in the composite image of two object points of the optical system under the influence of defocusing effect when an asymmetric phase edges are imposed over the apodized circular aperture. The resolution of two point sources having different intensity ratio is discussed in terms of the modified Sparrow criterion, functions of the degree of coherence of the illumination, the intensity difference and the degree of asymmetric phase masking. Here we have introduced and explored the effects of focus aberration (defect-of-focus) on the two-point resolution of the optical systems. Results on the aberrated composite image of closely spaced objects with amplitude mask and asymmetric phase masks forms a significant contribution in astronomical and microscopic observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neural Network Astronomy as a New Tool for Observing Bright and Compact Objects

We propose a new method for solving an important problem of astronomy that arises in observations with ultrahigh-angular-resolution interferometers. This method is based on the application of the theory of artificial neural networks. We propose and compute a multiparameter model for a celestial object like Sgr A*. For this model we have numerically constructed a number of probable images for neural network training. After neural network training on these images, the quality of its operation has been tested on another series of images from the same model. We have proven that a neural network can recognize and classify celestial objects (also obtained from interferometers) virtually no worse than can be done by a human.

79 ASTRONOMY AND ASTROPHYSICS↗

Recombination in GaAs p–i–n Structures with InGaAs Quantum-Confined Objects: Modeling and Regularities

Photovoltaic structures on the basis of GaAs p–i–n junctions with a different number of In{sub 0.4}Ga{sub 0.6}As layers in the space-charge region forming quantum-confined objects are experimentally and theoretically investigated. For all structures, the dependences of the open-circuit voltage on the solar-irradiation concentration are analyzed. It is shown that the implantation of quantum objects leads to the dominance of recombination in them over recombination in the matrix, which manifests itself in a drop in the open-circuit-voltage. An increase in the number of In{sub 0.4}Ga{sub 0.6}As layers leads to a proportional increase in the recombination rate, which is expressed in a proportional increase in the “saturation” current and corresponds to the model proposed in the study.

36 MATERIALS SCIENCE↗

A Sequential Quadratic Programming Algorithm for Nonsmooth Problems with Upper- \({\boldsymbol{\mathcal{C}^2}}\) Objective

An optimization algorithm for nonsmooth nonconvex constrained optimization problems with upper- \({\boldsymbol{\mathcal{C}^2}}\) objective functions is proposed and analyzed. Upper- \({\boldsymbol{\mathcal{C}^2}}\) is a weakly concave property that exists in difference of convex (DC) functions and arises naturally in many applications, particularly certain classes of solutions to parametric optimization problems e.g., recourse of stochastic programming and projection onto closed sets. The algorithm can be viewed as an extension of sequential quadratic programming (SQP) to nonsmooth problems with upper- \({\boldsymbol{\mathcal{C}^2}}\) objectives or a simplified bundle method. It is globally convergent with bounded algorithm parameters that are updated with a trust-region criterion. The algorithm handles general smooth constraints through linearization and uses a line search to ensure progress. The potential inconsistencies from the linearization of the constraints are addressed through a penalty method. In conclusion, the capabilities of the algorithm are demonstrated by solving both simple upper- \({\boldsymbol{\mathcal{C}^2}}\) problems and a real-world optimal power flow problem used in current power grid industry practices.

97 MATHEMATICS AND COMPUTING↗

Laika BOSS (Binary Object Scanning System)

Laika BOSS (Binary Object Scanning System), often written as "Laikaboss", is an object scanner and intrusion detection system that strives to be scalable, flexible, and verbose. Its goal is to take arbitrary file input and extract all relevant subfiles and metadata for use in helping analysts determine the function and maliciousness of a file at a glance. This is an extension to the original code developed by Lockheed Martin.

Walkup, Gregory↗

Incoherent range-based holography of far-distant objects using LIDAR

Los Alamos National Laboratory has developed an incoherent, long-range, sub-centimeter resolution (LIDAR) with which we achieve centimeter-scale reflection holography at extremely long ranges. The system consists of a pulsed laser and photon-counting receiver. This combination yields round-trip time of flight data to illuminate parts of the object of interest. The aggregation of these data for many LIDAR pulses yields a plot with a range on the X axis and reflectance on the Y axis, which we refer to as a range profile. Observing that the range profile is a projection of the reflection map of the object onto the view vector, we collect profiles from a variety of viewing angles and invert these data to form an image. We adapt imaging algorithms from the field of computer aided tomography to suit our application and present results from imaging demonstrations at a 10 km range.

Hoffmann, Mitchell P. (ORCID:0000000170551324)↗

Laser Doppler sensor employing a single fan-shaped interference fringe system for distance and shape measurement of laterally moving objects

For monitoring the position and shape of fast moving and, especially, rotating objects such as turbo machine rotors, contactless and compact sensors with a high measurement rate as well as high precision are required. We present for the first time, to the best of our knowledge, a novel laser Doppler sensor employing a single fan-shaped interference fringe system, which allows measuring for the position and shape of fast moving solid bodies with known tangential velocity. It is shown theoretically as well as experimentally that this sensor offers concurrently high position resolution and high temporal resolution in contrast to conventional measurement techniques, since its measurement uncertainty is, in principle, independent of the object velocity. Moreover, it can be built very compact, because it features low complexity. To prove its operational capability and its potential for practical applications, radial and axial shape measurements of rotating bodies are demonstrated in comparison with triangulation. An average position resolution of about 2 {mu}m could be achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase and amplitude retrieval of objects embedded in a sinusoidal background from its diffraction pattern

Efforts of phase and amplitude retrieval from diffraction patterns have almost exclusively been applied for nonperiodic objects. We investigated the quality of retrieval of nonperiodic objects embedded in a sinusoidal background, using the approach of iterative hybrid input-output with oversampling. Two strategies were employed; one by filtering in the frequency domain prior to phase retrieval, and the other by filtering the phase or amplitude image after retrieval. Results obtained indicate better outcomes with the latter approach provided detector noise is not excessive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray tomography of extended objects: a comparison of data acquisition approaches

The penetration power of x-rays allows one to image large objects while their short wavelength allows for high spatial resolution. As a result, with synchrotron sources one has the potential to obtain tomographic images of centimeter-sized specimens with sub-micrometer pixel sizes. However, limitations on beam and detector size make it difficult to acquire such data of this sort in a single take, necessitating strategies for combining data from multiple regions. One strategy is to acquire a tiled set of local tomograms by rotating the specimen around each of the local tomogram center positions. Another strategy, sinogram oriented acquisition, involves the collection of projections at multiple offset positions from the rotation axis followed by data merging and reconstruction. We have carried out a simulation study to compare these two approaches in terms of radiation dose applied to the specimen, and reconstructed image quality. Local tomography acquisition involves an easier data alignment problem, and immediate viewing of subregions before the entire dataset has been acquired. Sinogram oriented acquisition involves a more difficult data assembly and alignment procedure, and it is more sensitive to accumulative registration error. Furthermore, sinogram oriented acquisition is more dose-efficient, it involves fewer translation motions of the object, and it avoids certain artifacts of local tomography.

47 OTHER INSTRUMENTATION↗

Image reconstruction exploiting object sparsity in boundary-enhanced X-ray phase-contrast tomography

Propagation-based X-ray phase-contrast tomography (PCT) seeks to reconstruct information regarding the complex-valued refractive index distribution of an object. In many applications, a boundary-enhanced image is sought that reveals the locations of discontinuities in the real-valued component of the refractive index distribution. We investigate two iterative algorithms for few-view image reconstruction in boundary-enhanced PCT that exploit the fact that a boundary-enhanced PCT image, or its gradient, is often sparse. In order to exploit object sparseness, the reconstruction algorithms seek to minimize the {ell}{sub 1}-norm or TV-norm of the image, subject to data consistency constraints. We demonstrate that the algorithms can reconstruct accurate boundary-enhanced images from highly incomplete few-view projection data.

47 OTHER INSTRUMENTATION↗

An efficient iterative algorithm for computation of scattering from dielectric objects.

We have developed an efficient iterative algorithm for electromagnetic scattering of arbitrary but relatively smooth dielectric objects. The algorithm iteratively adapts the equivalent surface currents until the electromagnetic fields inside and outside the dielectric objects match the boundary conditions. Theoretical convergence is analyzed for two examples that solve scattering of plane waves incident upon air/dielectric slabs of semi-infinite and finite thicknesses. We applied the iterative algorithm for simulation of sinusoidally-perturbed dielectric slab on one side and the method converged for such unsmooth surfaces. We next simulated the shift in radiation pattern of a 6-inch dielectric lens for different offsets of the feed antenna on the focal plane. The result is compared to that of the Geometrical Optics (GO).

36 MATERIALS SCIENCE↗

Environmental Management System (EMS) objectives & targets : annual results summary %3CU%2B2013%3E FY10.

Sandia National Laboratory/New Mexico's (SNL/NM) Environmental Management System is the integrated approach for members of the workforce to identify and manage environmental risks. Each fiscal year (FY) significant environmental aspects are identified and the environmental programs associated with them are charged with the task of routinely monitoring and measuring the objectives and targets that are designed to mitigate the impact of SNL/NM's operations on the environment. An annual summary of the results achieved towards meeting established objectives and targets provides a connection to and rational for annually revised significant aspects. The purpose of this document is to summarize the results achieved and documented in FY2010.

54 ENVIRONMENTAL SCIENCES↗