Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Electron Induced Scintillation Testing of Commercially Available Optical Fibers for Space Flight

A test to verify the performance of several commercial and military optical fibers available on the market today was conducted, via usage of an electron accelerator, to monitor radiation induced scintillation or luminescence. The test results showed that no significant effects could be detected with the PMT system used, above a noise floor of 50 photons/sec that were due to optical fiber scintillation. Although some data appeared to show events taking place, noise scan results have correlated these events to arcing inside the electron accelerator facility. This test was to simply characterize for space flight, which optical fiber candidates were the largest scintillators among the eighteen optical fiber candidates tested.

Ott, Melanie N.↗

Calibration of Predictor Models Using Multiple Validation Experiments

This paper presents a framework for calibrating computational models using data from several and possibly dissimilar validation experiments. The offset between model predictions and observations, which might be caused by measurement noise, model-form uncertainty, and numerical error, drives the process by which uncertainty in the models parameters is characterized. The resulting description of uncertainty along with the computational model constitute a predictor model. Two types of predictor models are studied: Interval Predictor Models (IPMs) and Random Predictor Models (RPMs). IPMs use sets to characterize uncertainty, whereas RPMs use random vectors. The propagation of a set through a model makes the response an interval valued function of the state, whereas the propagation of a random vector yields a random process. Optimization-based strategies for calculating both types of predictor models are proposed. Whereas the formulations used to calculate IPMs target solutions leading to the interval value function of minimal spread containing all observations, those for RPMs seek to maximize the models' ability to reproduce the distribution of observations. Regarding RPMs, we choose a structure for the random vector (i.e., the assignment of probability to points in the parameter space) solely dependent on the prediction error. As such, the probabilistic description of uncertainty is not a subjective assignment of belief, nor is it expected to asymptotically converge to a fixed value, but instead it casts the model's ability to reproduce the experimental data. This framework enables evaluating the spread and distribution of the predicted response of target applications depending on the same parameters beyond the validation domain.

Crespo, Luis G.↗

Acoustic and Performance Measurements Obtained in the NASA Langley Small Hover Anechoic Chamber

The emergence of small Unmanned Aircraft Systems (UAS) and Advanced Air Mobility (AAM) vehicles has motivated the need to acoustically characterize the rotors found on these vehicle platforms. Hover chamber tests of small rotors are beneficial in assessing the noise impact of UAS, and potentially larger AAM vehicles. Various experiments have been conducted in the NASA Langley Small Hover Anechoic Chamber (SHAC), formerly known as the Small Anechoic Jet Facility (SAJF), in order to investigate the noise and performance of small rotors. One of these tests was that of an “ideally twisted rotor”, which was designed in order to simplify the theoretical rotor inflow for a target thrust condition in hover. This rotor was fabricated using state-of-the-art rapid prototyping and tested in the SHAC. Aerodynamic load and acoustic data were acquired across a range of rotation rates and rotor collective settings. Both tonal and broadband components were identified in the acoustic data, with broadband noise being a prominent contributor to the overall rotor system noise.

Nicole Pettingill↗

Fine Optimization of TES Design for the X-IFU Instrument on ATHENA

The X-ray Integral Field Unit (X-IFU) instrument on the Advanced Telescope for High ENergy Astrophysics (ATHENA) is baselined to have 3168 transition-edge sensor (TES) microcalorimeter pixels. These pixels will be DC biased and readout using time division multiplexing. We recently reported a demonstration of the required pixel and readout performance in 252 pixels from a 1 kilo-pixel array (e.g. 2.16 eV resolution for 6.9 keV X-rays). Having achieved the required performance, the 50um square TES design in this demonstration array is considered the baseline pixel design for X-IFU. However, by making small adjustments to the TES design, we may be able to make small but consequential improvements to the instrument performance, while staying within the many constraints of the X-IFU requirements. In this presentation, we will show results from newly fabricated devices with subtle changes from the baseline TES design to further optimize the performance for X-IFU. We will discuss optimizing the TES sheet resistance, normal metal features, X-ray absorber attachment points, TES aspect ratio, and heat capacity. These minor design changes can have significant effects on thermo-electric time constants, thermal fluctuation noise, resistive transition shape and uniformity, and non-linearity of X-ray event pulses. In addition, full characterization of these new TES designs allows greater understanding of the relevant physics within the TES and gives routes for further optimization.

Nick Wakeham↗

Photon Sieve Design and Fabrication for Imaging Characteristics Using UAV Flight

The Photon Sieve (PS) team at NASA Langley Research Center (LaRC) began receiving support for the development and characterization of PS devices through the NASA Internal Research & Development Program (IRAD) in 2015. The project involves ascertaining the imaging characteristics of various PS devices. These devices hold the potential to significantly reduce mission costs and improve imaging quality by replacing traditional reflector telescopes. The photon sieve essentially acts as a lens to diffract light to a concentrated point on the focal plane like a Fresnel Zone Plate (FZP). PS’s have the potential to focus light to a very small spot which is not limited by the width of the outermost zone as for the FZP and offers a promising solution for high resolution imaging. In the fields of astronomy, remote sensing, and other applications that require imaging of distant objects both on the ground and in the sky, it is often necessary to perform post-process filtering in order to separate noise signals that arise from multiple scattering events near the collection optic. The PS exhibits a novel filtering technique that rejects the unwanted noise without the need for time consuming post processing of the images. This project leverages key Langley resources to design, manufacture, and characterize a series of photon sieve specimens. After a prototype was developed and characterized in the Langley ISO5 optical cleanroom and laboratory, outside testing was conducted via the capture of images of the moon by using a telescopic setup. This next goal of the project is to design and develop a telescope and image capture system as a drone-based instrument payload. The vehicle utilized for the initial demonstration was a NASA hive model 1200 XE-8 research Unmanned Aerial Vehicle (UAV), capable of handling a 20-pound maximum payload with a 25-minute flight time. This NASA Technical Memorandum (NASA-TM) introduces preliminary results obtained using a PS-based imaging system on the UAV. The next version of the telescope structure will be designed around diffractive optical components and commercially available camera electronics to create a lightweight payload.

Kim, Hyun Jung↗

NASA Tech Briefs, October 2009

Topics covered include: Light-Driven Polymeric Bimorph Actuators; Guaranteeing Failsafe Operation of Extended-Scene Shack-Hartmann Wavefront Sensor Algorithm; Cloud Water Content Sensor for Sounding Balloons and Small UAVs; Pixelized Device Control Actuators for Large Adaptive Optics; T-Slide Linear Actuators; G4FET Implementations of Some Logic Circuits; Electrically Variable or Programmable Nonvolatile Capacitors; System for Automated Calibration of Vector Modulators; Complementary Paired G4FETs as Voltage-Controlled NDR Device; Three MMIC Amplifiers for the 120-to-200 GHz Frequency Band; Low-Noise MMIC Amplifiers for 120 to 180 GHz; Using Ozone To Clean and Passivate Oxygen-Handling Hardware; Metal Standards for Waveguide Characterization of Materials; Two-Piece Screens for Decontaminating Granular Material; Mercuric Iodide Anticoincidence Shield for Gamma-Ray Spectrometer; Improved Method of Design for Folding Inflatable Shells; Ultra-Large Solar Sail; Cooperative Three-Robot System for Traversing Steep Slopes; Assemblies of Conformal Tanks; Microfluidic Pumps Containing Teflon[Trademark] AF Diaphragms; Transparent Conveyor of Dielectric Liquids or Particles; Multi-Cone Model for Estimating GPS Ionospheric Delays; High-Sensitivity GaN Microchemical Sensors; On the Divergence of the Velocity Vector in Real-Gas Flow; Progress Toward a Compact, Highly Stable Ion Clock; Instruments for Imaging from Far to Near; Reflectors Made from Membranes Stretched Between Beams; Integrated Risk and Knowledge Management Program -- IRKM-P; LDPC Codes with Minimum Distance Proportional to Block Size; Constructing LDPC Codes from Loop-Free Encoding Modules; MMICs with Radial Probe Transitions to Waveguides; Tests of Low-Noise MMIC Amplifier Module at 290 to 340 GHz; and Extending Newtonian Dynamics to Include Stochastic Processes.

Source record↗

A Josephson junction with h -BN tunnel barrier: observation of low critical current noise

Decoherence in quantum bits (qubits) is a major challenge for realizing scalable quantum computing. One of the primary causes of decoherence in qubits and quantum circuits based on superconducting Josephson junctions is the critical current fluctuation. Many efforts have been devoted to suppressing the critical current fluctuation in Josephson junctions. Nonetheless, the efforts have been hindered by the defect-induced trapping states in oxide-based tunnel barriers and the interfaces with superconductors in the traditional Josephson junctions. Motivated by this, along with the recent demonstration of 2D insulator h-BN with exceptional crystallinity and low defect density, we fabricated a vertical NbSe 2 /h-BN/Nb Josephson junction consisting of a bottom NbSe 2 superconductor thin layer and a top Nb superconductor spaced by an atomically thin h-BN layer. Furthermore, we characterized the superconducting current and voltage (I–V) relationships and Fraunhofer pattern of the NbSe 2 /h-BN/Nb junction. Notably, we demonstrated the critical current noise (1/f noise power) in the h-BN-based Josephson device is at least a factor of four lower than that of the previously studied aluminum oxide-based Josephson junctions. Our work offers a strong promise of h-BN as a novel tunnel barrier for high-quality Josephson junctions and qubit applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic Method for Identifying Collected Sample Mass

G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

Carson, John↗

Signal processing applied to photothermal techniques for materials characterization

There is a need to make noncontact measurements of material characteristics in the microgravity environment. Photothermal and photoacoustics techniques offer one approach for attaining this capability since lasers can be used to generate the required thermal or acoustic signals. The perturbations in the materials that can be used for characterization can be detected by optical reflectance, infrared detection or laser detection of photoacoustics. However, some of these laser techniques have disadvantages of either high energy pulsed excitation or low signal-to-noise ratio. Alternative signal processing techniques that have been developed can be applied to photothermal or photoacoustic instrumentation. One fully coherent spread spectrum signal processing technique is called time delay spectrometry (TDS). With TDS the system is excited using a combined frequency-time domain by employing a linear frequency sweep excitation function. The processed received signal can provide either frequency, phase or improved time resolution. This signal processing technique was shown to outperform other time selective techniques with respect to noise rejection and was recently applied to photothermal instrumentation. The technique yields the mathematical equivalent of pulses yet the input irradiances are orders of magnitude less than pulses with the concomitant reduction in perturbation of the sample and can increase the capability of photothermal methods for materials characterization.

Rooney, James A.↗

Visible Contrast Energy Metrics for Detection and Discrimination

Contrast energy was proposed by Watson, Robson, & Barlow as a useful metric for representing luminance contrast target stimuli because it represents the detectability of the stimulus in photon noise for an ideal observer. Like the eye, the ear is a complex transducer system, but relatively simple sound level meters are used to characterize sounds. These meters provide a range of frequency sensitivity functions and integration times depending on the intended use. We propose here the use of a range of contrast energy measures with different spatial frequency contrast sensitivity weightings, eccentricity sensitivity weightings, and temporal integration times. When detection threshold are plotting using such measures, the results show what the eye sees best when these variables are taken into account in a standard way. The suggested weighting functions revise the Standard Spatial Observer for luminance contrast detection and extend it into the near periphery. Under the assumption that the detection is limited only by internal noise, discrimination performance can be predicted by metrics based on the visible energy of the difference images

Ahumada, Albert↗

Diagnosing and Destroying Non-Markovian Noise

Nearly every protocol used to analyze the performance of quantum information processors is based on an assumption that the errors experienced by the device during logical operations are constant in time and are insensitive to external contexts. This assumption is pervasive, rarely stated, and almost always wrong. Quantum devices that do behave this way are termed "Markovian:' but nearly every system we have ever probed has displayed drift or crosstalk or memory effects they are all non-Markovian. Strong non-Markovianity introduces spurious effects in characterization protocols and violates assumptions of the fault-tolerance threshold theorems. This SAND report details a three year laboratory-directed research and development (LDRD) project entitled, "Diagnosing and Destroying non-Markovian Noise in Quantum Information Processors." This program was initiated to build tools to study non-Markovian dynamics and quantum systems and develop robust methodologies for eliminating it. The program achieved a number of notable successes, including the first statistically rigorous protocol for identifying and characterizing drift in quantum systems, a formalism for modeling memory effects in quantum devices, and the successful suppression of drift in a Sandia trapped-ion quantum processor.

97 MATHEMATICS AND COMPUTING↗

Characterization of Crystal Properties and Defects in CdZnTe Radiation Detectors

CdZnTe-based detectors are highly valued because of their high spectral resolution, which is an essential feature for nuclear medical imaging. However, this resolution is compromised when there are substantial defects in the CdZnTe crystals. In this study, we present a learning-based approach to determine the spatially dependent bulk properties and defects in semiconductor detectors. This characterization allows us to mitigate and compensate for the undesired effects caused by crystal impurities. We tested our model with computer-generated noise-free input data, where it showed excellent accuracy, achieving an average RMSE of 0.43% between the predicted and the ground truth crystal properties. In addition, a sensitivity analysis was performed to determine the effect of noisy data on the accuracy of the model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

Fouling modeling and prediction approach for heat exchangers using deep learning

In this article, we develop a generalized and scalable statistical model for accurate prediction of fouling resistance using commonly measured parameters of industrial heat exchangers. This prediction model is based on deep learning where a scalable algorithmic architecture learns non-linear functional relationships between a set of target and predictor variables from large number of training samples. Here, the efficacy of this modeling approach is demonstrated for predicting fouling in an analytically modeled cross-flow heat exchanger, designed for waste heat recovery from flue-gas using room temperature water. The performance results of the trained models demonstrate that the mean absolute prediction errors are under 10 –4 KW –1 for flue-gas side, water side and overall fouling resistances. The coefficients of determination (R 2 ), which characterize the goodness of fit between the predictions and observed data, are over 99%. Even under varying levels of measurement noise in the inputs, we demonstrate that predictions over an ensemble of multiple neural networks achieves better accuracy and robustness to noise. We find that the proposed deep-learning fouling prediction framework learns to follow heat exchanger flow and heat transfer physics, which we confirm using locally interpretable model agnostic explanations around randomly selected operating points. Overall, we provide a robust algorithmic framework for fouling prediction that can be generalized and scaled to various types of industrial heat exchangers.

42 ENGINEERING↗

Machine-learning-based automatic small-angle measurement between planar surfaces in interferometer images: A 2D multilayer Laue lenses case

Here, we report a new machine-learning-based approach to automatically measure the small angle between multiple planar surfaces characterized by white light interferometers. By applying an unsupervised clustering algorithm, DBSCAN (Density-Based Spatial Clustering of Applications with Noise), the multiple surfaces in an interferometer image are automatically identified as distinct surfaces. The angles between every two surfaces are then calculated through the surface fitting. This method can be applied to multiple surfaces regardless of their shapes and locations and significantly simplifies the angle measurement procedure. Using the developed method, we have demonstrated a quick and precise angle measurement for the alignment of 2D Multilayer Laue Lenses (MLLs) for the development of high-resolution x-ray microscopy. This automatic, accurate, and robust small-angle measurement method is compatible with widely used white light interferometers and can be further applied to other metrology applications of interferometer results.

36 MATERIALS SCIENCE↗

The fundamental structure function of oscillator noise models

Continuous-time models of oscillator phase noise x(t) usually have stationary nth differences, for some n. The covariance structure of such a model can be characterized in the time domain by the structure function: D sub n (t;gamma sub 1, gamma sub 2) = E delta (n) sub gamma sub 1 x(s+t) delta(n) sub gamma sub 2 x (s). Although formulas for the special case D sub 2 (0;gamma,gamma) (the Allan variance times 2 gamma(2)) exist for power-law spectral models, certain estimation problems require a more complete knowledge of (0). Exhibited is a much simpler function of one time variable, D(t), from which (0) can easily be obtained from the spectral density by uncomplicated integrations. Believing that D(t) is the simplest function of time that holds the same information as (0), D(t) is called the fundamental structure function. D(t) is computed for several power-law spectral models. Two examples are D(t) = K/t/(3) for random walk FM, D(t) = Kt(2) 1n/t/ for flicker FM. Then, to demonstrate its use, a BASIC program is given that computes means and variances of two Allan variance estimators, one of which incorporates a method of frequency drift estimation and removal.

Greenhall, C. A.↗

Local intensity adaptive image coding

The objective of preprocessing for machine vision is to extract intrinsic target properties. The most important properties ordinarily are structure and reflectance. Illumination in space, however, is a significant problem as the extreme range of light intensity, stretching from deep shadow to highly reflective surfaces in direct sunlight, impairs the effectiveness of standard approaches to machine vision. To overcome this critical constraint, an image coding scheme is being investigated which combines local intensity adaptivity, image enhancement, and data compression. It is very effective under the highly variant illumination that can exist within a single frame or field of view, and it is very robust to noise at low illuminations. Some of the theory and salient features of the coding scheme are reviewed. Its performance is characterized in a simulated space application, the research and development activities are described.

Huck, Friedrich O.↗

In situ Pulsed Laser Deposition of C-Axis Oriented MgB2 Films and Their Characterization

The recent discovery of an intermetallic superconductor MgB2 has renewed interest in the area of superconductivity not only because of fundamental understanding of superconductivity but also due to its potential applicability in devices such as thermal detectors. Considerable amount of research has been devoted to obtain MgB2 films by an all in situ growth technique. We have grown MgB2 thin films by an all in situ pulsed laser deposition process from pure B and Mg targets. Ultrathin layers of B and Mg were deposited in a multilayer configuration. Hundreds of such Mg-B bilayers with a capping Mg layer on the top were deposited on sapphire substrate. These depositions were done in high vacuum (approx. 10(exp -7) Torr) and at room temperature. After deposition, such a configuration was annealed at high temperature for a short time in a forming gas (4% H2 in Ar). The best films, obtained by this procedure, showed superconducting transition temperature approx. 30 K. These films have been characterized by x-ray diffraction, Rutherford Backscattering Spectrometry, AC susceptibility-, resistivity- (with and without magnetic field) and 1/f noise-measurements. The physical properties of these films will be presented and discussed.

Shinde, Sanjay↗