Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “New”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

First Observation of the Hadronic Transition Υ ( 4 S ) → η h b ( 1 P ) and New Measurement of the h b ( 1 P ) and η b ( 1 S ) Parameters

Using a sample of 771.6 × 10 6 Υ Υ ( 4 S ) decays collected by the Belle experiment at the KEKB e + e - collider, we observe, for the first time, the transition Υ ( 4 S ) → η h b ( 1 P ) with the branching fraction B [ Υ ( 4 S ) → η h b ( 1 P ) ] = ( 2.18 ± 0.11 ± 0.18 ) × 10 - 3 and we measure the h b ( 1 P ) mass M h b ( 1 P ) = ( 9899.3 ± 0.4 ± 1.0 ) MeV / c 2 , corresponding to the hyperfine (HF) splitting Δ M HF ( 1 P ) = ( 0.6 ± 0.4 ± 1.0 ) MeV / c 2 . Using the transition h b ( 1 P ) → γ η b ( 1 S ) , we measure the η b ( 1 S ) mass M η b ( 1 S ) = ( 9400.7 ± 1.7 ± 1.6 ) MeV / c 2 , corresponding to Δ M HF ( 1 S ) = ( 59.6 ± 1.7 ± 1.6 ) MeV / c 2 , the η b ( 1 S ) width Γ η b ( 1 S ) = ( 8 - 5 + 6 ± 5 ) MeV / c 2 and the branching fraction B [ h b ( 1 P ) → γ η b ( 1 S ) ] = ( 56 ± 8 ± 4 ) % .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low- and room-temperature X-ray structures of protein kinase A ternary complexes shed new light on its activity

ATP bound in the active site of protein kinase A is readily hydrolysed to ADP and free phosphate by X-ray irradiation at room temperature. The phosphate ion observed in the active site causes a dramatic conformational change of the bound peptide inhibitor. Post-translational protein phosphorylation by protein kinase A (PKA) is a ubiquitous signalling mechanism which regulates many cellular processes. A low-temperature X-ray structure of the ternary complex of the PKA catalytic subunit (PKAc) with ATP and a 20-residue peptidic inhibitor (IP20) at the physiological Mg{sup 2+} concentration of ∼0.5 mM (LT PKA–MgATP–IP20) revealed a single metal ion in the active site. The lack of a second metal in LT PKA–MgATP–IP20 renders the β- and γ-phosphoryl groups of ATP very flexible, with high thermal B factors. Thus, the second metal is crucial for tight positioning of the terminal phosphoryl group for transfer to a substrate, as demonstrated by comparison of the former structure with that of the LT PKA–Mg{sub 2}ATP–IP20 complex obtained at high Mg{sup 2+} concentration. In addition to its kinase activity, PKAc is also able to slowly catalyze the hydrolysis of ATP using a water molecule as a substrate. It was found that ATP can be readily and completely hydrolyzed to ADP and a free phosphate ion in the crystals of the ternary complex PKA–Mg{sub 2}ATP–IP20 by X-ray irradiation at room temperature. The cleavage of ATP may be aided by X-ray-generated free hydroxyl radicals, a very reactive chemical species, which move rapidly through the crystal at room temperature. The phosphate anion is clearly visible in the electron-density maps; it remains in the active site but slides about 2 Å from its position in ATP towards Ala21 of IP20, which mimics the phosphorylation site. The phosphate thus pushes the peptidic inhibitor away from the product ADP, while resulting in dramatic conformational changes of the terminal residues 24 and 25 of IP20. X-ray structures of PKAc in complex with the nonhydrolysable ATP analogue AMP-PNP at both room and low temperature demonstrated no temperature effects on the conformation and position of IP20.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New Hybrid Model for Evaluating the Frequency-Dependent Leakage Inductance of a Variable Inductance Transformer (VIT)

Skin and proximity effects can cause a significant drop in the effective leakage inductance of a transformer when the operating frequency is increased. Although the magnetic image method-based double-2-D model can calculate the lowfrequency leakage inductance with sufficient accuracy, it is inherently a frequency-independent model. While Dowell’s 1-D model uses frequency-dependent relations to account for both skin and proximity effects, its accuracy is severely affected by the assumed winding geometry. In this paper, a hybrid model is proposed that uses superposition to combine a modified Dowell’s model with the double-2-D model. The proposed model is investigated on a variable inductance transformer (VIT)—a partially-filled transformer whose leakage inductance can be varied by moving one of the windings mechanically. The frequency-dependent leakage inductances of the VIT evaluated using the hybrid model are in excellent agreement with the corresponding finite element method (FEM) simulated and experimentally measured values, thereby validating the proposed hybrid model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Tool Evaluates the Financial Viability of Pumped Storage Hydropower

The rapidly evolving electricity system with increasing variable renewable energy (VRE) resources provides both opportunities and challenges for the power sector. With the significant ramps and intermittency associated with VRE resources, the requirements and need for additional flexible resources increase. Pumped storage hydropower (PSH) provides flexibility to the electricity grid to replace fossil fuel plants, which are responsible for 25% of U.S. emissions. PSH projects support various aspects of power system operations, including flexibility, ramping capability, energy, ancillary service, black start, and others. The significant potential of hydropower requires understanding the different value drivers to the electricity system specific to the location of a project and then optimizing the plant for the different system values. Thus, determining the value of PSH projects and their many services and contributions to the electricity system can be a challenge for potential developers, system owners, regulators, policy makers, and consultants.

13 HYDRO ENERGY↗

Reconciling estimates of the contemporary North American carbon balance among terrestrial biosphere models, atmospheric inversions and a new approach for estimating net ecosystem exchange from inventory-based data

While fossil fuel emissions are calculated with relatively high precision, understanding the fate of those emissions with respect to sequestration in terrestrial ecosystems requires data and methods that can reduce uncertainties in the diagnosis of land-based CO2 sinks. The wide range in the land surface flux estimates is related to a number of factors, but most generally because of the different methodologies used to develop estimates of carbon stocks and flux, and the uncertainties inherent in each approach. The alternative approaches to estimating continental scale carbon fluxes that we explored here can be broadly classified as applying a top-down or bottom-up perspective. Top-down approaches calculate land-atmosphere carbon fluxes based on atmospheric budgets and inverse modeling. Bottom-up approaches rely primarily on measurements of carbon stock changes (the inventory approach) or on spatially distributed simulations of carbon stocks and/or fluxes using process-based modeling (the forward modelapproach).

Hayes, D J↗

Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams

Purpose: In this report the authors present the validation of a Monte Carlo dose calculation algorithm (XiO EMC from Elekta Software) for electron beams. Methods: Calculated and measured dose distributions were compared for homogeneous water phantoms and for a 3D heterogeneous phantom meant to approximate the geometry of a trachea and spine. Comparisons of measurements and calculated data were performed using 2D and 3D gamma index dose comparison metrics. Results: Measured outputs agree with calculated values within estimated uncertainties for standard and extended SSDs for open applicators, and for cutouts, with the exception of the 17 MeV electron beam at extended SSD for cutout sizes smaller than 5 × 5 cm{sup 2}. Good agreement was obtained between calculated and experimental depth dose curves and dose profiles (minimum number of measurements that pass a 2%/2 mm agreement 2D gamma index criteria for any applicator or energy was 97%). Dose calculations in a heterogeneous phantom agree with radiochromic film measurements (>98% of pixels pass a 3 dimensional 3%/2 mm γ-criteria) provided that the steep dose gradient in the depth direction is considered. Conclusions: Clinically acceptable agreement (at the 2%/2 mm level) between the measurements and calculated data for measurements in water are obtained for this dose calculation algorithm. Radiochromic film is a useful tool to evaluate the accuracy of electron MC treatment planning systems in heterogeneous media.

61 RADIATION PROTECTION AND DOSIMETRY↗