Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Quantifying modeling uncertainties when combining multiple gravitational-wave detections from binary neutron star sources

Here, with the increasing sensitivity of gravitational-wave detectors, we expect to observe multiple binary neutron-star systems through gravitational waves in the near future. The combined analysis of these gravitational-wave signals offers the possibility to constrain the neutron-star radius and the equation of state of dense nuclear matter with unprecedented accuracy. However, it is crucial to ensure that uncertainties inherent in the gravitational-wave models will not lead to systematic biases when information from multiple detections is combined. To quantify waveform systematics, we perform an extensive simulation campaign of binary neutron-star sources and analyze them with a set of four different waveform models. For our analysis with 38 simulations, we find that statistical uncertainties in the neutron-star radius decrease to ± 250 m (2% at 90% credible interval) but that systematic differences between currently employed waveform models can be twice as large. Hence, it will be essential to ensure that systematic biases will not become dominant in inferences of the neutron-star equation of state when capitalizing on future developments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron sensitivity and detection efficiency of {sup 3}He and {sup 10}BF{sub 3} counters

An analytic relationship between the efficiency, sensitivity, and the coefficient of working-isotope utilization is established for gas-filled cylindrical thermal-neutron counters. This dependence is expressed in terms of the ratio of the characteristic length of a counter to its diameter. The characteristic size is introduced as the ratio of the total absorption cross section to the length of the counter. The parameters of basic {sup 3}He and {sup 10}BF{sub 3} counters used in NM-64 neutron monitors are calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron multiplicity ,easurements With 3 He alternative: Straw neutron detectors

Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10 B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions of neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3 He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10 B (in the form of enriched boron carbide: 10 B 4 C) for neutron detection instead of 3 He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lithium-containing scintillators for thermal neutron, fast neutron, and gamma detection

In one embodiment, a scintillator includes a scintillator material; a primary fluor, and a Li-containing compound, where the Li-containing compound is soluble in the primary fluor, and where the scintillator exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons and gamma rays.

36 MATERIALS SCIENCE↗

Detecting sub-MeV neutrons in solid plastic scintillator with gamma-ray discrimination

We report on recent efforts to design a solid plastic scintillation hodoscope to measure neutron production cross sections at low energies. Our program includes not only the development of the detector itself, but also a set of auxiliary measurements which will help characterize its low-energy response. A novel scintillation counter has been developed to detect sub-MeV neutrons while rejecting gamma-ray backgrounds with good efficiency. The detector uses multiple layers of thin solid scintillator, with optical isolation between the adjacent layers. Incident low-energy neutrons produce ionizing recoil particles which remain within just one of the scintillator layers, while background gamma rays create electrons which most often cross the boundary between layers. By observing the trigger pattern within the layers, most gamma-ray backgrounds can be distinguished from the low-energy neutrons of interest. We report on the results of our Monte Carlo studies of this design, as well as on the operation of a prototype detector unit. We also have undertaken a new measurement of the neutron-proton total cross section below 1 MeV. Calculations of the efficiency for detecting low energy neutrons in plastic scintillator rely on accurate low energy n-p cross sections, yet surprisingly few such data currently exist. New measurements which span the region from 150 to 800 keV neutron (lab) energy are reported and discussed. Additionally, we have measured the light response of BC 418 scintillator for recoil proton energies as low as 100 keV. Recoil protons are produced at a known energy in the scintillator by placing it in a neutron beam and detecting in coincidence the elastically scattered neutrons at fixed angle. Our new results extend the energy range of previous measurements of the light response of solid organic scintillators, and may indicate a significantly modified response at the lowest observed energies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Use of a Multichannel Analyzer to Investigate Effects of Experimental Factors on Gross-Counting Gamma and Neutron Detectors

Radiation detection technology is invaluable to many fields of study in identifying nuclear materials. However, many detectors use gross-counting methods that give only a relative count rate. Without a spectrum (information on counts over time vs energy), it can be more difficult to discern if an alarm is false, innocent, or real. In particular, we would like to understand better the effect of experimental factors (i.e., external conditions and equipment parameters) on detector data, with possible implications for false alarms. To more thoroughly characterize detector technology, a multichannel analyzer (MCA) was used to record spectra from neutron (helium-3 tubes) and gamma (photomultiplier tubes) gross-counting detectors. Several factors could affect the signal-to-noise ratio of sources. For example, we examined the effects of neutron detector high voltage setting on the appearance of a californium-252 spectrum, the effect of discriminator values on integrated counts in neutron detection, and the effect of gain changes on the gamma spectra from several sources. Possible implications of ambient temperature of the experiment on the data collected will be discussed. The input impedance of the MCA must be considered to ensure that data are not affected by the measurement itself. Moreover, a calibration on the MCA was performed to verify the conversion of a MCA channel number to a voltage. In summary, the series of source spectra collected on an MCA with a variety of experimental conditions allow us to understand factors that affect data better, and assure us that gross-counting neutron and gamma detectors will have minimal false alarms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plastic scintillator with effective pulse shape discrimination for neutron and gamma detection

In one embodiment, a scintillator material includes a polymer matrix; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 5 wt % or more; wherein the scintillator material exhibits an optical response signature for neutrons that is different than an optical response signature for gamma rays. In another embodiment, a scintillator material includes a polymer matrix; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount greater than 10 wt %.

36 MATERIALS SCIENCE↗

Plastic scintillator with effective pulse shape discrimination for neutron and gamma detection

In one embodiment, a scintillator material includes a polymer matrix; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 5 wt % or more; wherein the scintillator material exhibits an optical response signature for neutrons that is different than an optical response signature for gamma rays. In another embodiment, a scintillator material includes a polymer matrix comprising at least one of: polyvinyl xylene (PVX); polyvinyl diphenyl; and polyvinyl tetrahydronaphthalene; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount greater than 10 wt %. A total loading of dye in the scintillator material is sufficient to cause the scintillator material to exhibit a pulse-shape discrimination (PSD) figure of merit (FOM) of about at least 2.0.

Zaitseva, Natalia P.↗

Intense Photoneutron Sources For Nuclear Material Detection

Intense neutron sources are essential for cargo inspection for a broad range of threats from explosives, to contraband, to nuclear materials and especially SNM (Special Nuclear Materials). To be effective over a wide range of cargo materials, in particular for hydrogenous cargo such as food, and to offer practical inspection times, the neutron source must be very strong, typically >10{sup 10} neutrons per second. Unfortunately there are currently no reasonably compact and economical neutron generators with the required intensities. The insufficiency and inadequacy of intense neutron sources are especially conspicuous in the {<=}2.5 MeV range (low voltage (d,D) generator). This energy range is needed if the strong signature of prompt fission neutrons ({approx_equal}3 per fission) is to be detected and discerned from the numerous source neutrons. The photonuclear reactions of x-rays from commercial linacs in appropriate converters can provide ample intensities of neutrons. These converters have a very low ({gamma},n) energy threshold: 1.67 MeV for beryllium and 2.23 MeV for deuterium. The intense x-ray beams provided by commercial x-ray systems, more than compensate for the relatively low ({gamma},n) cross-sections which are in the milli-barn range. The choice of converter material, the geometrical shape, dimensions and location relative to the x-ray source, determine the efficiency of the neutron conversion. For electron accelerators with less than 10 MeV, the preferred converters, Be and D{sub 2}O, are also very good neutron moderators. Thus, while increasing the converters' thickness leads to an increase in the overall neutron yield, this causes the softening of the neutron spectrum, which reduces the neutron penetration especially in hydrogenous cargos. Photoneutron sources can be optimized to meet specific needs such as maximum fission signals in various cargo materials of interest. Efficient photoneutron sources with different energy spectra were investigated. Conversion efficiency of more than 10-4 neutron per 9 MeV electron yielding neutron intensities of more than 10{sup 11} n/s for commercial 100 {mu}Amp electron accelerators has been modeled and designed. The simulation was validated in laboratory experiments using small Be and D{sub 2}O converters.

43 PARTICLE ACCELERATORS↗

Electro-optic Laser-Sampled Neutron Detector

A new method of detecting radiation which can allow for long distance measurements is being investigated. The device is primarily for neutrons detection althought it could, in principle, be used for gamma ray detection. The neutron detection medium is a solid, transparent, electro-optical material, such as lithium niobate, lithium tantalite, or barium borate. Crystals of these materials act as optical gates to laser light, allowing light to pass through only when a neutron interaction occurs in the crystal. Typical light detection devices, such as CCD cameras or photomultiplier tubes, can be used to signal when light passes through the crystal. The overall goal of the project is to investigate the feasibility of such devices for the detection of neutron radiation and to quantify their capabilities and limitations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Small-Angle Neutron Scattering to Detect Nanoscopic Lipid Domains

The cell plasma membrane is a complex system, which is thought to be capable of exhibiting non-random lateral organization. Studies of live cells and model membranes have yielded mechanisms responsible for the formation, growth, and maintenance of nanoscopic heterogeneities, although the existence and mechanisms that give rise to these heterogeneities remain controversial. Small-angle neutron scattering (SANS) is a tool ideally suited to interrogate lateral heterogeneity in model membranes, primarily due to its unique spatial resolution (i.e., "5 100 nm) and its ability to resolve structure with minimal perturbation to the membrane. In this review we examine several methods used to analyze the SANS signal arising from freely suspended unilamellar vesicles containing lateral heterogeneity. Specifically, we discuss an analytical model for a single, round domain on a spherical vesicle. We then discuss a numerical method that uses Monte Carlo simulation to describe systems with multiple domains and/or more complicated morphologies. Also discussed are several model-independent approaches that are sensitive to membrane heterogeneity. The review concludes with several recent applications of SANS to the study of membrane raft mixtures.

Pan, Jianjun↗

Optimum lithium loading of a liquid scintillator for neutron and neutrino detection

Neutral particle detection in high-background environments is greatly aided by the ability to easily load 6 Li into liquid scintillators. In this work, we describe a readily available and inexpensive liquid scintillation cocktail stably loaded with a Li mass fraction up to 1%. Compositions that give thermodynamically stable microemulsions (reverse-micellar systems) were explored, using a Compton spectrum quenching technique to distinguish these from unstable emulsions. Scintillation light yield and transmittance were characterized. Pulse shape discrimination (PSD) was measured using a 252 Cf source, showing that electron-like and proton-like recoil events are well-resolved even for Li loading up to 1%, providing a means of background suppression in neutron/neutrino detectors. While samples in this work were prepared with nat Li (7.59% 6 Li), the neutron capture peak was clearly visible in the PSD spectrum; this implies that while extremely high capture efficiency could be achieved with 6 Li-enriched material, a very inexpensive neutron-sensitive detector can be prepared with nat Li.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-background EN-detector for the investigation of the neutron component of EASs

Thermal neutrons are detected using a scintillator compound based on ZnS(Ag) with B{sub 2}O{sub 3} added to it. The pulse height generated by single charged particles in a scintillator of small thickness (50 mg/cm{sup 2}) is not larger than that of a noise signal due to a low sensitivity to single charged particles. As a result, the detector satisfies the requirements of a low-background one in the context of cosmic-ray experiments. The detector is to be used for neutron detection in extensive air showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling of the hydration water dynamics and the internal dynamics of actin detected by quasielastic neutron scattering

Highlights: ► Quasielastic neutron scattering spectra of F-actin and G-actin were measured. ► Analysis of the samples in D{sub 2}O and H{sub 2}O provided the spectra of hydration water. ► The first layer hydration water around F-actin is less mobile than around G-actin. ► This difference in hydration water is in concert with the internal dynamics of actin. ► Water outside the first layer behaves bulk-like but influenced by the first layer. -- Abstract: In order to characterize dynamics of water molecules around F-actin and G-actin, quasielastic neutron scattering experiments were performed on powder samples of F-actin and G-actin, hydrated either with D{sub 2}O or H{sub 2}O, at hydration ratios of 0.4 and 1.0. By combined analysis of the quasielastic neutron scattering spectra, the parameter values characterizing the dynamics of the water molecules in the first hydration layer and those of the water molecules outside of the first layer were obtained. The translational diffusion coefficients (D{sub T}) of the hydration water in the first layer were found to be 1.2 × 10{sup −5} cm{sup 2}/s and 1.7 × 10{sup −5} cm{sup 2}/s for F-actin and G-actin, respectively, while that for bulk water was 2.8 × 10{sup −5} cm{sup 2}/s. The residence times were 6.6 ps and 5.0 ps for F-actin and G-actin, respectively, while that for bulk water was 0.62 ps. These differences between F-actin and G-actin, indicating that the hydration water around G-actin is more mobile than that around F-actin, are in concert with the results of the internal dynamics of F-actin and G-actin, showing that G-actin fluctuates more rapidly than F-actin. This implies that the dynamics of the hydration water is coupled to the internal dynamics of the actin molecules. The D{sub T} values of the water molecules outside of the first hydration layer were found to be similar to that of bulk water though the residence times are strongly affected by the first hydration layer. This supports the recent observation on intracellular water that shows bulk-like behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New prompt fission neutron spectra measurements in the 238 U(n,f) reaction with a dedicated setup at LANSCE/WNR

A new prompt fission neutron spectra (PFNS) measurement in the 238 U(n,f) reaction was performed at LANSCE/WNR facility. Evaluated data show discrepancies on the low (below 1 MeV) and high (above 5 MeV) energy parts in the PFNS for different major and minor actinides. The goal is to improve these measurements in a wide range of incident energy. The energy of the incoming neutron, inducing the fission, and the prompt neutron energies, are measured by time-of-flight method. A dedicated fission chamber was developed, in order to improve alpha-fission discrimination, timing resolution, actinide mass, and to reduce the amount of neutron scattering. To detect prompt neutrons, the 54 Chi-Nu scintillator cells array were surrounding the fission chamber. High statistics were recorded during this experiment, allowing a precise study of PFNS behavior as a function of incident neutron energy, from 1 MeV to 200 MeV. In conclusion, this experiment also showed that all the new tools developed to improve PFNS measurements are performing. Therefore, measurements of PFNS with others actinides such as 239 Pu are planned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly dispersive magnons with spin-gap-like features in the frustrated ferromagnetic S = 1 2 chain compound Ca 2 Y 2 Cu 5 O 10 detected by inelastic neutron scattering

In this paper, we report inelastic neutron scattering experiments in Ca 2 Y 2 Cu 5 O 10 and map out the full one-magnon dispersion which extends up to a record value of 53 meV for frustrated ferromagnetic (FM) edge-sharing CuO 2 chain (FFESC) cuprates. A homogeneous spin-1/2 chain model with a FM nearest-neighbor (NN), an antiferromagnetic (AFM) next-nearest-neighbor (NNN) inchain, and two diagonal AFM interchain couplings (ICs) analyzed within linear spin-wave theory (LSWT) reproduces well the observed strong dispersion along the chains and a weak one perpendicularly. The ratio α=| J a 2 / J a 1 | of the FM NN and the AFM NNN couplings is found as ~0.23, close to the critical point α c =1/4 which separates ferromagnetically and antiferromagnetically correlated spiral magnetic ground states in single chains, whereas α c >0.25 for coupled chains is considerably upshifted even for relatively weak IC. Although the measured dispersion can be described by homogeneous LSWT, the scattering intensity appears to be considerably reduced at ~11.5 and ~28 meV. The gaplike feature at 11.5 meV is attributed to magnon-phonon coupling whereas based on density matrix renormalization group simulations of the dynamical structure factor the gap at 28 meV is considered to stem partly from quantum effects due to the AFM IC. Another contribution to that gap is ascribed to the intrinsic superstructure from the distorting incommensurate pattern of CaY cationic chains adjacent to the CuO 2 ones. It gives rise to nonequivalent CuO 4 units and Cu-O-Cu bond angles Φ and a resulting distribution of all exchange integrals. The J 's fitted by homogeneous LSWT are regarded as average values. The record value of the FM NN integral J 1 =24 meV among FFESC cuprates can be explained by a nonuniversal Φ(≠90°) and Cu-O bond length dependent anisotropic mean direct FM Cu-O exchange $\overline{K}_{pd}$~120 meV, similar to a value of 105 meV for Li 2 CuO 2 , in accord with larger values for La 2 CuO 4 and CuGeO 3 (~110 meV) reported by Braden et al . [Phys. Rev. B 54, 1105 (1996)] phenomenologically. Lastly, enhanced $K_{pd}$ values are also needed to compensate a significant AFM J dd ≥ 6 meV from the dd channel, generic for FFESC cuprates but ignored so far.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗