Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

SU-D-18A-05: Assessing Elekta MLC Tracking Performance

Purpose: To investigate the technical feasibility of using Elekta MLCs in tracked radiotherapy, specifically to show the capability of an Agility MLC to follow model tumor trajectories using object tracking. The system performance of the MLC is to be assessed via dosimetric experiments and temporal response measures. Methods: The system observer in the tracking cascade consisted of a camera serving for this proof of concept; Images of a moving object were acquired continuously and decorrelated for the position information, which was fed forward to the RT computer controlling the MLC via an interface provided by Elekta. The 1D motion (in the direction of the leaves) was induced by a CIRS motion controller. Additionally, the aperture position was observed by means of the light field of the linac. Calculating the phase between aperture and object yielded the mean aperture lag for the current setup. The object was restricted to sinusoidal motion with a period of 10s. For dosimetry, GafChromic radiosensitive film was irradiated with a total dose of 1000MU using an aperture size of 40mm and a motion range of 30mm. Results: Object tracking can substantially reconstruct the geometric dose response of a static target. In the dynamic case, dose is smeared out into the legs of the static distribution, leading to a reduced plateau and increased FWHM of 5mm, compared to the static width of 38mm. The time-lag between object and aperture was determined to be approximately 300ms for the current set-up. Conclusion: We demonstrated a tracking experiment performed on a clinical Elekta linear accelator for the first time. Observed profile variations show the dosimetric impact of tracked delivery. The determined lag is a valuable descriptor for a future tracking cascade employing predictor filters. The performed experiments are generic and possible predecessors for future applications with MR-Linac or ultrasound probes. Conflict of interest: this project is partly funded by Elekta.

60 APPLIED LIFE SCIENCES↗

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U↗

Adaptive independent joint control of manipulators - Theory and experiment

The author presents a simple decentralized adaptive control scheme for multijoint robot manipulators based on the independent joint control concept. The proposed control scheme for each joint consists of a PID (proportional integral and differential) feedback controller and a position-velocity-acceleration feedforward controller, both with adjustable gains. The static and dynamic couplings that exist between the joint motions are compensated by the adaptive independent joint controllers while ensuring trajectory tracking. The proposed scheme is implemented on a MicroVAX II computer for motion control of the first three joints of a PUMA 560 arm. Experimental results are presented to demonstrate that trajectory tracking is achieved despite strongly coupled, highly nonlinear joint dynamics. The results confirm that the proposed decentralized adaptive control of manipulators is feasible, in spite of strong interactions between joint motions. The control scheme presented is computationally very fast and is amenable to parallel processing implementation within a distributed computing architecture, where each joint is controlled independently by a simple algorithm on a dedicated microprocessor.

Seraji, H.↗

Numerical and experimental comparison of tracer particle and averaging techniques for particle velocities in a fluidized bed

Particle tracking methods using emitted radiation show potential for following motion in opaque systems such as granular materials. Leading examples are Positron Emission Particle Tracking (PEPT) and Radioactive Particle Tracking (RPT). The application of such techniques sometimes requires the use of tracer particles which differ in size, density and/or shape from the particles of interest. This study investigates the extent to which such differences affect the result of the study by using the open source MFIX-DEM software to model particle motion in the travelling fluidized bed experiments. The results are compared with previously reported experimental studies using both PEPT and RPT. Consistent numerical results were obtained for both PEPT and RPT tracer particles. In determining averaged velocities using such techniques, there is a choice to be made between averaging velocities of particles crossing a virtual plane over a period of time (the “face-average” approach) or those passing through a defined volume over time (the “volume-average” approach). The differences between results obtained with these two methods are shown to be significant in this case, for both computation and experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.

60 APPLIED LIFE SCIENCES↗

Performance of the ice motion tracker at the Alaska SAR facility

An ice motion tracker has been implemented as part of the Ice/Ocean Geophysical Processor System (GPS) at the Alaska Synthetic Aperture Radar (SAR) Facility. The motion tracker operates in an unsupervised mode and utilizes a combination of feature-based and area-based matching to construct the displacement field from time-separated SAR imagery. The tracker is used to generate routine motion products for investigations of the kinematics and dynamics of sea ice in the polar regions. A number of filters for elimination of outliers and incorrect matches have been implemented to maintain the quality of the motion vector product. Preliminary evaluation of the tracking algorithm with European Space Agency Remote Sensing Satellite (ERS-1) data indicate that these requirements are satisfied. The performance and shortcomings of the motion tracker are discussed.

Kwok, Ronald↗

Spherical Coordinate Systems for Streamlining Suited Mobility Analysis

When describing human motion, biomechanists generally report joint angles in terms of Euler angle rotation sequences. However, there are known limitations in using this method to describe complex motions such as the shoulder joint during a baseball pitch. Euler angle notation uses a series of three rotations about an axis where each rotation is dependent upon the preceding rotation. As such, the Euler angles need to be regarded as a set to get accurate angle information. Unfortunately, it is often difficult to visualize and understand these complex motion representations. One of our key functions is to help design engineers understand how a human will perform with new designs and all too often traditional use of Euler rotations becomes as much of a hindrance as a help. It is believed that using a spherical coordinate system will allow ABF personnel to more quickly and easily transmit important mobility data to engineers, in a format that is readily understandable and directly translatable to their design efforts. Objectives: The goal of this project is to establish new analysis and visualization techniques to aid in the examination and comprehension of complex motions. Methods: This project consisted of a series of small sub‐projects, meant to validate and verify the method before it was implemented in the ABF's data analysis practices. The first stage was a proof of concept, where a mechanical test rig was built and instrumented with an inclinometer, so that its angle from horizontal was known. The test rig was tracked in 3D using an optical motion capture system, and its position and orientation were reported in both Euler and spherical reference systems. The rig was meant to simulate flexion/extension, transverse rotation and abduction/adduction of the human shoulder, but without the variability inherent in human motion. In the second phase of the project, the ABF estimated the error inherent in a spherical coordinate system, and evaluated how this error would vary within the reference frame. This stage also involved expanding a kinematic model of the shoulder, to include the torso, knees, ankle, elbows, wrists and neck. Part of this update included adding a representation of 'roll' about an axis, for upper arm and lower leg rotations. The third stage of the project involved creating visualization methods to assist in interpreting motion in a spherical frame. This visualization method will be incorporated in a tool to evaluate a database of suited mobility data, which is currently in development.

Benson, Elizabeth↗

The NASA Inductrack Model Rocket Launcher at the Lawrence Livermore National Laboratory

The Inductrack magnetic levitation system, developed at the Lawrence Livermore National Laboratory, is being studied for its possible use for launching rockets. Under NASA sponsorship, a small model system is being constructed at the Laboratory to pursue key technical aspects of this proposed application. The Inductrack is a passive magnetic levitation system employing special arrays of high-field permanent magnets (Halbach arrays) on the levitating carrier, moving above a "track" consisting of a close-packed array of shorted coils with which are interleaved with special drive coils. Halbach arrays produce a strong spatially periodic magnetic field on the front surface of the arrays, while canceling the field on their back surface. Relative motion between the Halbach arrays and the track coils induces currents in those coils. These currents levitate the carrier cart by interacting with the horizontal component of the magnetic field. Pulsed currents in the drive coils, synchronized with the motion of the carrier, interact with the vertical component of the magnetic field to provide acceleration forces. Motional stability, including resistance to both vertical and lateral aerodynamic forces, is provided by having Halbach arrays that interact with both the upper and the lower sides of the track coils. In its completed form the model system that is under construction will have a track approximately 100 meters in length along which the carrier cart will be propelled up to peak speeds of Mach 0.4 to 0.5 before being decelerated. Preliminary studies of the parameters of a full-scale system have also been made. These studies address the problems of scale-up, including means to simplify the track construction and to reduce the cost of the pulsed-power systems needed for propulsion.

Tung, L. S.↗

Near-Surface Flow Fields Deduced Using Correlation Tracking and Time-Distance Analysis

Near-photospheric flow fields on the Sun are deduced using two independent methods applied to the same time series of velocity images observed by SOI-MDI on SOHO. Differences in travel times between f modes entering and leaving each pixel measured using time-distance helioseismology are used to determine sites of supergranular outflows. Alternatively, correlation tracking analysis of mesogranular scales of motion applied to the same time series is used to deduce the near-surface flow field. These two approaches provide the means to assess the patterns and evolution of horizontal flows on supergranular scales even near disk center, which is not feasible with direct line-of-sight Doppler measurements. We find that the locations of the supergranular outflows seen in flow fields generated from correlation tracking coincide well with the locations of the outflows determined from the time-distance analysis, with a mean correlation coefficient after smoothing of bar-r(sub s) = 0.840. Near-surface velocity field measurements can used to study the evolution of the supergranular network, as merging and splitting events are observed to occur in these images. The data consist of one 2048-minute time series of high-resolution (0.6" pixels) line-of-sight velocity images taken by MDI on 1997 January 16-18 at a cadence of one minute.

DeRosa, Marc↗

Residual Motion and Duty Time in Respiratory Gating Radiotherapy Using Individualized or Population-Based Windows

Purpose: The efficiency and precision of respiratory gated radiation therapy for tumors is affected by variations in respiration-induced tumor motion. We evaluated the use of individualized and population-based parameters for such treatment. Methods and Materials: External respiratory signal records and images of respiration-induced tumor motion were obtained from 42 patients undergoing respiratory gated radiation therapy for liver tumors. Gating window widths were calculated for each patient, with 2, 4, and 10 mm of residual motion, and the mean was defined as the population-based window width. Residual motions based on population-based and predefined window widths were compared. Duty times based on whole treatment sessions, at various window levels, were calculated. The window level giving the longest duty time was defined as the individualized most efficient level (MEL). MELs were also calculated based on the first 10 breathing cycles. The duty times for population-based MELs (defined as mean MELs) and individualized MELs were compared. Results: Tracks of respiration-induced tumor motion ranged from 3 to 50 mm. Half of the patients had larger actual residual motions than the assigned residual motions. Duty times were greater when based on individualized, rather than population-based, window widths. The MELs established during whole treatment sessions for 2 mm and 4 mm of residual motion gave significantly increased duty times, whereas those calculated using the first 10 breathing cycles showed only marginal increases. Conclusions: Using individualized window widths and levels provided more precise and efficient respiratory gated radiation therapy. However, methods for predicting individualized window levels before treatment remain to be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Electromagnetic Transponder Use to Monitor Inter- and Intrafractional Motion in Locally Advanced Pancreatic Cancer Patients

Purpose: The primary objective of this study was to determine the feasibility of electromagnetic transponder implantation in patients with locally advanced unresectable pancreatic cancer. Secondarily, the use of transponders to monitor inter- and intrafractional motion, and the efficacy of breath holding for limiting target motion, were examined. Methods and Materials: During routine screening laparoscopy, 5 patients without metastatic disease were implanted with transponders peri-tumorally. The Calypso System's localization and tracking modes were used to monitor inter- and intrafractional motion, respectively. Intrafractional motion, with and without breath holding, was also examined using Calypso tracking mode. Results: Transponder implantation was well tolerated in all patients, with minimal migration, aside from 1 patient who expulsed a single transponder. Interfractional motion based on mean shifts from setup using tattoos/orthogonal imaging to transponder based localization from 164 treatments was significant in all dimensions. Mean shift (in millimeters), followed by the standard deviation and p value, were as follows: X-axis: 4.5 mm (1.0, p = 0.01); Y axis: 6.4 mm (1.9, p = 0.03); and Z-axis 3.9 mm (0.6, p = 0.002). Mean intrafractional motion was also found to be significant in all directions: superior, 7.2 mm (0.9, p = 0.01); inferior, 11.9 mm (0.9, p < 0.01); anterior: 4.9 mm (0.5, p = 0.01); posterior, 2.9 mm (0.5, p = 0.02); left, 2.2 mm (0.4, p = 0.02); and right, 3.1 mm (0.6, p = 0.04). Breath holding during treatment significantly decreased tumor motion in all directions. Conclusions: Electromagnetic transponder implantation appears to be safe and effective for monitoring inter- and intrafractional motion. Based on these results a larger clinical trial is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

"Eztrack": A single-vehicle deterministic tracking algorithm

A variety of surveillance operations require the ability to track vehicles over a long period of time using sequences of images taken from a camera mounted on an airborne or similar platform. In order to be able to see and track a vehicle for any length of time, either a persistent surveillance imager is needed that can image wide fields of view over a long time-span or a highly maneuverable smaller field-of-view imager is needed that can follow the vehicle of interest. The algorithm described here was designed for the persistence surveillance case. In turns out that most vehicle tracking algorithms described in the literature[1,2,3,4] are designed for higher frame rates (> 5 FPS) and relatively short ground sampling distances (GSD) and resolutions ({approx} few cm to a couple tens of cm). But for our datasets, we are restricted to lower resolutions and GSD's ({ge}0.5 m) and limited frame-rates ({le}2.0 Hz). As a consequence, we designed our own simple approach in IDL which is a deterministic, motion-guided object tracker. The object tracking relies both on object features and path dynamics. The algorithm certainly has room for future improvements, but we have found it to be a useful tool in evaluating effects of frame-rate, resolution/GSD, and spectral content (eg. grayscale vs. color imaging ). A block diagram of the tracking approach is given in Figure 1. We describe each of the blocks of the diagram in the upcoming sections.

42 ENGINEERING↗

Nanoparticle Tracking to Probe Transport in Porous Media

From the granular and fractured subsurface environment to highly engineered polymer membranes used in pharmaceutical purification, porous materials are ubiquitous in nature and industrial applications. In particular, porous media are used extensively in processes including water treatment, pharmaceutical sterilization, food/beverage processing and heterogeneous catalysis, where hindered mass transport is either essential to the process or a necessary, but undesirable limitation. Unfortunately, there are currently no universal models capable of predicting mass transport based on a description of the porous material because real porous materials are complex, and because many coupled dynamic mechanisms (e.g. adsorption, steric effects, hydrodynamic effects, electrostatic interactions, etc.) give rise to the observed macroscopic transport phenomena. While classical techniques, like nuclear magnetic resonance and dynamic light scattering, provide useful information about mass transport in porous media at the ensemble level, they provide limited insight into the microscopic mechanisms that give rise to complex phenomena such as anomalous diffusion, hindered pore-space accessibility, and unexpected retention under flow, among many others. To address this issue, we have developed refractive index matching imaging systems, combined with single-particle tracking methods, allowing the direct visualization of single particle motion within a variety of porous materials. Here, we summarize our recent efforts to advance the understanding of nanoparticle transport in porous media using single-particle tracking methods in both fundamental and applied scenarios. First, we describe the basic principles for two-dimensional and three-dimensional single-particle tracking in porous materials. Then, we describe concrete examples of nanoparticle transport in porous materials from two perspectives: (1) understanding fundamental elementary particle transport processes in porous media, including pore accessibility and cavity escape, which limit transport in porous media; (2) facilitating applications in industrial processes, e.g. by understanding the mechanisms of particle fouling and remobilization in filtration membranes. Finally, we provide an outlook of opportunities associated with investigating other types of mass transport in confined environments using single-particle tracking methods, including electrophoretic and self-propelled motion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Positron emission tracking of individual particles in particle-laden rimming flow

The motion of a single tracer particle in particle-laden rimming flows is investigated experimentally by means of Positron Emission Particle Tracking (PEPT). Semi-dilute suspensions, with a volume fraction of 8% of heavy particles are considered. The trajectory of the tracer particle is monitored for several thousand cylinder revolutions and related to the optically recorded drift of the large-scale granular segregation bands developing in the cylinder. Results of the data analysis provide first insights into the relation between behaviour of individual particles and the spatiotemporal dynamics displayed by the macroscopic particle-segregation patterns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Satellite-tracking and Earth dynamics research programs

The activities carried out by the Smithsonian Astrophysical Observatory (SAO) are described. The SAO network continued to track LAGEOS at highest priority for polar motion and Earth rotation studies, and for other geophysical investigations, including crustal dynamics, Earth and ocean tides, and the general development of precision orbit determination. The network performed regular tracking of several other retroreflector satellites including GEOS-1, GEOS-3, BE-C, and Starlette for refined determinations of station coordinates and the Earth's gravity field and for studies of solid Earth dynamics. A major program in laser upgrading continued to improve ranging accuracy and data yield. This program includes an increase in pulse repetition rate from 8 ppm to 30 ppm, a reduction in laser pulse width from 6 nsec to 2 to 3 nsec, improvements in the photoreceiver and the electronics to improve daylight ranging, and an analog pulse detection system to improve range noise and accuracy. Data processing hardware and software are discussed.

Source record↗

Satellite tracking and earth dynamics research programs

The SAO laser site in Arequipa continued routine operations throughout the reporting period except for the months of March and April when upgrading was underway. The laser in Orroral Valley was operational through March. Together with the cooperating stations in Wettzell, Grasse, Kootwikj, San Fernando, Helwan, and Metsahove the laser stations obtained a total of 37,099 quick-look observations on 978 passes of BE-C, Starlette, and LAGEOS. The Network continued to track LAGEOS at highest priority for polar motion and Earth rotation studies, and for other geophysical investigations, including crustal dynamics, Earth and ocean tides, and the general development of precision orbit determination. The Network performed regular tracking of BE-C and Starlette for refined determinations of station coordinate and the Earth's gravity field and for studies of solid earth dynamics. Monthly statistics of the passes and points are given by station and by satellite.

Source record↗

The Effect of Geocenter Motion on Jason-2 Orbits and the Mean Sea Level

We compute a series of Jason-2 GPS and SLR/DORIS-based orbits using ITRF2005 and the std0905 standards (Lemoine et al. 2010). Our GPS and SLR/DORIS orbit data sets span a period of 2 years from cycle 3 (July 2008) to cycle 74 (July 2010). We extract the Jason-2 orbit frame translational parameters per cycle by the means of a Helmert transformation between a set of reference orbits and a set of test orbits. We compare the annual terms of these time-series to the annual terms of two different geocenter motion models where biases and trends have been removed. Subsequently, we include the annual terms of the modeled geocenter motion as a degree-1 loading displacement correction to the GPS and SLR/DORIS tracking network of the POD process. Although the annual geocenter motion correction would reflect a stationary signal in time, under ideal conditions, the whole geocenter motion is a non-stationary process that includes secular trends. Our results suggest that our GSFC Jason-2 GPS-based orbits are closely tied to the center of mass (CM) of the Earth consistent with our current force modeling, whereas GSFC's SLR/DORIS-based orbits are tied to the origin of ITRF2005, which is the center of figure (CF) for sub-secular scales. We quantify the GPS and SLR/DORIS orbit centering and how this impacts the orbit radial error over the globe, which is assimilated into mean sea level (MSL) error, from the omission of the annual term of the geocenter correction. We find that for the SLR/DORIS std0905 orbits, currently used by the oceanographic community, only the negligence of the annual term of the geocenter motion correction results in a 4.67 plus or minus 3.40 mm error in the Z-component of the orbit frame which creates 1.06 plus or minus 2.66 mm of systematic error in the MSL estimates, mainly due to the uneven distribution of the oceans between the North and South hemisphere.

Melachroinos, S. A.↗

Liver motion during cone beam computed tomography guided stereotactic body radiation therapy

Purpose: Understanding motion characteristics of liver such as, interfractional and intrafractional motion variability, difference in motion within different locations in the organ, and their complex relationship with the breathing cycles are particularly important for image-guided liver SBRT. The purpose of this study was to investigate such motion characteristics based on fiducial markers tracked with the x-ray projections of the CBCT scans, taken immediately prior to the treatments. Methods: Twenty liver SBRT patients were analyzed. Each patient had three fiducial markers (2 Multiplication-Sign 5-mm gold) percutaneously implanted around the gross tumor. The prescription ranged from 2 to 8 fractions per patient. The CBCT projections data for each fraction ({approx}650 projections/scan), for each patient, were analyzed and the 2D positions of the markers were extracted using an in-house algorithm. In total, >55 000 x-ray projections were analyzed from 85 CBCT scans. From the 2D extracted positions, a 3D motion trajectory of the markers was constructed, from each CBCT scans, resulting in left-right (LR), anterior-posterior (AP), and cranio-caudal (CC) location information of the markers with >55 000 data points. The authors then analyzed the interfraction and intrafraction liver motion variability, within different locations in the organ, and as a function of the breathing cycle. The authors also compared the motion characteristics against the planning 4DCT and the RPM Trade-Mark-Sign (Varian Medical Systems, Palo Alto, CA) breathing traces. Variations in the appropriate gating window (defined as the percent of the maximum range at which 50% of the marker positions are contained), between fractions were calculated as well. Results: The range of motion for the 20 patients were 3.0 {+-} 2.0 mm, 5.1 {+-} 3.1 mm, and 17.9 {+-} 5.1 mm in the planning 4DCT, and 2.8 {+-} 1.6 mm, 5.3 {+-} 3.1 mm, and 16.5 {+-} 5.7 mm in the treatment CBCT, for LR, AP, and CC directions, respectively. The range of respiratory period was 3.9 {+-} 0.7 and 4.2 {+-} 0.8 s during the 4DCT simulation and the CBCT scans, respectively. The authors found that breathing-induced AP and CC motions are highly correlated. That is, all markers moved cranially also moved posteriorly and vice versa, irrespective of the location. The LR motion had a more variable relationship with the AP/CC motions, and appeared random with respect to the location. That is, when the markers moved toward cranial-posterior direction, 58% of the markers moved to the patient-right, 22% of the markers moved to the patient-left, and 20% of the markers had minimal/none motion. The absolute difference in the motion magnitude between the markers, in different locations within the liver, had a positive correlation with the absolute distance between the markers (R{sup 2}= 0.69, linear-fit). The interfractional gating window varied significantly for some patients, with the largest having 29.4%-56.4% range between fractions. Conclusions: This study analyzed the liver motion characteristics of 20 patients undergoing SBRT. A large variation in motion was observed, interfractionally and intrafractionally, and that as the distance between the markers increased, the difference in the absolute range of motion also increased. This suggests that marker(s) in closest proximity to the target be used.

60 APPLIED LIFE SCIENCES↗