Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modularity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Scalable Framework of Hybrid Modeling with Anticipatory Control Strategy for Autonomous Operation of Modular and Microreactors

This poster provides a high level overview of the Scalable Framework of Hybrid Modeling with Anticipatory Control Strategy for Autonomous Operation of Modular and Microreactors LDRD program to be presented at a poster session for students of the 2021 MeV School. The purpose of the poster is to provide other participants of the MeV School with a high level overview of the author's research direction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

A Modularized Urban Scale Building Energy Modeling Framework Designed with An Open Mind

In recent years, physics-based building energy modeling (BEM) has started being used to evaluate the performance of buildings in the context of connected communities and on an urban scale to study their aggregated energy use, interactions, and impacts on the energy supply infrastructure and environment. The development of urban-scale BEM solutions needs extensive effort. Existing attempts tend to focus on different aspects of BEM on an urban scale, such as collecting as-built building data from different information sources, integrating geometry modeling with geographic information systems (GISs), representing operational and occupancy profiles, automating workflow, processing and visualizing the results, and conducting large-scale simulations. Urban-scale BEM development would benefit from multi-disciplinary research areas and from an open platform to adopt advancements on data sources and tools. For these purposes, this research proposes a modularized bottom-up model creation and simulation framework that is built on the state-of-the-art BEM tools and can accommodate different building stock data. This framework uses a standardized schema to describe building design and operational characteristics, and it can be instantiated from different building survey datasets with heterogeneous structures. The paper demonstrates how thousands of surveyed buildings from the 2012 U.S. Energy Information Administration’s Commercial Buildings Energy Consumption Survey (CBECS) were one-to-one converted to EnergyPlus models through the schema and the model generation process, then simulated with distributed computing, and their results are summarized.

Lei, Xuechen↗

Oxy-combustion process with modular boiler design

A modular boiler system for implementing fuel combustion is provided. The system includes a first boiler and a second boiler of a plurality of boilers, an oxygen input unit, a fuel input unit, a recycled flue gas input unit, and a flue gas separator. The first boiler receives oxygen from the oxygen input unit, fuel from the fuel input unit, and recycled flue gas from the recycled flue gas input unit. The first boiler outputs intra-system flue gas. The flue gas separator separates the intra-system flue gas into a first and second flue gas stream, transfers the first flue gas stream to the second boiler, and transfers the second flue gas stream to a gas cleaning system. The second boiler receives oxygen from the oxygen input unit, fuel from the fuel input unit, and the first flue gas stream from the flue gas separator.

Axelbaum, Richard L.↗

Modular High Temperature Gas-Cooled Reactor: Safety Design Approach

Deployment Objectives Flexibly co-locate with new industry users of nuclear energy Steam and electric cogeneration applications Direct process heat with temperature ranges from 700°C to 950°C Enabling Requirements Meet regulatory dose limits at the Exclusion Area Boundary (EAB) 25 rem Total Effective Dose Equivalent (TEDE) for duration of the release from 10 CFR 50.34 (10 CFR 52.79) at Exclusion Area Boundary (EAB) for design basis accidents EAB is estimated approximately 400 meters from the modular HTGR plant (to support co-location with industrial facilities) Meet safety goals for cumulative individual risk for normal and off-normal operation Design goal: meet EPA Protective Action Guides (PAGs) at EAB 1 rem TEDE for sheltering Design basis and beyond design basis events are considered Realistically evaluated at the EAB Emergency planning and protection

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modular High Temperature Gas-Cooled Reactor: Licensing Part I

NRC PRA Policy Statement motivates risk-informed, performance-based (RIPB) approach to modular High Temperature Gas-cooled Reactor (HTGR) licensing Complements traditional deterministic design approach to increase use of risk insights in design and licensing decisions Risk-informed approach: Explicit consideration to a broader set of challenges Logical prioritization of challenges Consideration of broader set of resources to defend against challenges Explicitly identifying and quantifying sources of uncertainty Better decision making by testing for sensitivity to key assumptions Performance-Based Approach: Measurable (or calculable) parameters for monitoring Objective criteria to assess performance

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast Modular Reactor Nuclear Design Parameters of Fuel Cycle and Power Distributions

This paper describes conceptual design of a 112 MW thermal (50 MW electric) Fast Modular Reactor (FMR) system operating at 7 MPa with inlet/outlet temperatures of 509/800 ºC. The reactor system includes the reactor core, fuel assemblies, fuel rods, reactor internals, reflector, neutron control system, flow control, and structural components. The nuclear design and analysis were conducted to search for a baseline core with a cycle length greater than 8-year and the power peaking factor less than 1.5 by adjusting the fuel assembly, reactor core, and reflector configurations. The neutronics calculations of the baseline core showed that a refueling interval of 9-year is achieved with a total peaking factor of 1.47 and a fuel rod average linear power of 3.6 kW/m.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modular power conversion system with galvanic insulation

A modular power conversion system is provided which includes a plurality of building blocks comprised of transformers and power conversion bridges, and a high frequency AC link that transfers power and provides galvanic isolation between the building blocks. The high frequency link includes an insulating tube separating an AC link conductor and the building blocks. The insulating tube is further provided with conductive or semiconductive layers on its inner and outer surfaces for referencing them to the electric potentials of the adjacent conductors and windings, thereby placing the high electric fields substantially directly across the tube and reducing electric fields and partial discharge or corona in the adjoining space or media. The building blocks may be arranged in multiple stacks for DC or AC interface, preferably with neutral or lower voltage connections at the outer edges of the stacks and higher voltage terminals at the centers of the stack.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular system and method for mercury speciation in a fluid sample

Modular Hg analysis devices and methods are described for use in mercury speciation protocols. Modules can be selected and removably connected to one another to specifically target mercury species in a sample so as to accurately determine the presence or quantity of different mercury species in a fluid sample. Modules can include reductants for reducing inorganic mercury to form elemental mercury and amalgamation agents to capture the elemental mercury. Modules can include filters for capture of particulates as well as capture agents, e.g., solid phase extraction agents, for capture of organic mercury species.

Looney, Brian B.↗

Modular anti-rotation drilling systems and methods

A modular anti-rotation device for preventing rotation with respect to the central axis of a drilling tool in a borehole and for producing a notch in a borehole surface. The anti-rotation device includes an upper fixture portion and a lower fixture portion in axial alignment. The upper fixture portion and the lower fixture portion are connected by yoke assemblies. Each yoke assembly is connected to the fixture portion and fixture portion at one end, and forming an articulated joint of the upper yoke assembly and the lower yoke assembly at a distal end opposite the first end. A roller is connected at each joint, connecting the upper and lower yoke assemblies. The rollers engage vertically with a borehole surface, the rollers travelling axially, as a drill shaft penetrates into the borehole, the rollers simultaneously preventing radial movement of the anti-rotation device and prevent rotation with respect to the central axis of the borehole.

Su, Jiann-Cherng↗

Evaluating Scaling Effects of Steam Condensation Physics-based Model for Small Modular Reactor

This study focused on assessing condensation heat transfer (CHT) models for enhancing the passive safety of small modular reactors (SMRs). It also encompassed a review of the theoretical and semi-theoretical CHT models and correlations. Condensation models such as the degradation factor, heat and mass transfer analogy (HMTA), and boundary layer models are used to study advanced nuclear reactor PCCS. The previous CHT models were developed for small tube geometries, which differ from the containment of SMR. This study examined the scaled relations of a physics-based CHT model for analyzing laminar and turbulent film condensation downward flow conditions inside scaled tube geometries.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Evaluating scaling effects of steam condensation physics-based model for small modular reactors safety

This study focused on assessing condensation heat transfer (CHT) models for enhancing the passive safety of small modular reactors (SMRs). It also encompassed a review of the theoretical and semi-theoretical CHT models and correlations. Condensation models such as the degradation factor, heat and mass transfer analogy (HMTA), and boundary layer models are used to study advanced nuclear reactor PCCS. The previous CHT models were developed for small tube geometries, which differ from the containment of SMR. This study examined the scaled relations of a physics-based CHT model for analyzing laminar and turbulent film condensation downward flow conditions inside scaled tube geometries.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Proliferation resistant fuel for pebble bed modular reactors

We show that it is possible to denature the Plutonium produced in Pebble Bed Modular Reactors (PBMR) by doping the nuclear fuel with either 3050 ppm of {sup 237}Np or 2100 ppm of Am vector. A correct choice of these isotopes concentration yields denatured Plutonium with isotopic ratio {sup 238}Pu/Pu {>=} 6%, for the entire fuel burnup cycle. The penalty for introducing these isotopes into the nuclear fuel is a subsequent shortening of the fuel burnup cycle, with respect to a non-doped reference fuel, by 41.2 Full Power Days (FPDs) and 19.9 FPDs, respectively, which correspond to 4070 MWd/ton and 1965 MWd/ton reduction in fuel discharge burnup. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Westinghouse Small Modular Reactor nuclear steam supply system design

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the first in a series of four papers which describe the design and functionality of the Westinghouse SMR. Also described in this series are the key drivers influencing the design of the Westinghouse SMR and the unique passive safety features of the Westinghouse SMR. Several critical motivators contributed to the development and integration of the Westinghouse SMR design. These design driving motivators dictated the final configuration of the Westinghouse SMR to varying degrees, depending on the specific features under consideration. These design drivers include safety, economics, AP1000{sup R} reactor expertise and experience, research and development requirements, functionality of systems and components, size of the systems and vessels, simplicity of design, and licensing requirements. The Westinghouse SMR NSSS consists of an integral reactor vessel within a compact containment vessel. The core is located in the bottom of the reactor vessel and is composed of 89 modified Westinghouse 17x17 Robust Fuel Assemblies (RFA). These modified fuel assemblies have an active core length of only 2.4 m (8 ft) long, and the entirety of the core is encompassed by a radial reflector. The Westinghouse SMR core operates on a 24 month fuel cycle. The reactor vessel is approximately 24.4 m (80 ft) long and 3.7 m (12 ft) in diameter in order to facilitate standard rail shipping to the site. The reactor vessel houses hot and cold leg channels to facilitate coolant flow, control rod drive mechanisms (CRDM), instrumentation and cabling, an intermediate flange to separate flow and instrumentation and facilitate simpler refueling, a pressurizer, a straight tube, recirculating steam generator, and eight reactor coolant pumps (RCP). The containment vessel is 27.1 m (89 ft) long and 9.8 m (32 ft) in diameter, and is designed to withstand pressures up to 1.7 MPa (250 psi). It is completely submerged in a pool of water serving as a heat sink and radiation shield. Housed within the containment are four combined core makeup tanks (CMT)/passive residual heat removal (PRHR) heat exchangers, two in-containment pools (ICP), two ICP tanks and four valves which function as the automatic depressurization system (ADS). The PRHR heat exchangers are thermally connected to two different ultimate heat sink (UHS) tanks which provide transient cooling capabilities. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Westinghouse Small Modular Reactor balance of plant and supporting systems design

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the second in a series of four papers which describe the design and functionality of the Westinghouse SMR. It focuses, in particular, upon the supporting systems and the balance of plant (BOP) designs of the Westinghouse SMR. Several Westinghouse SMR systems are classified as safety, and are critical to the safe operation of the Westinghouse SMR. These include the protection and monitoring system (PMS), the passive core cooling system (PXS), and the spent fuel cooling system (SFS) including pools, valves, and piping. The Westinghouse SMR safety related systems include the instrumentation and controls (I and C) as well as redundant and physically separated safety trains with batteries, electrical systems, and switch gears. Several other incorporated systems are non-safety related, but provide functions for plant operations including defense-in-depth functions. These include the chemical volume control system (CVS), heating, ventilation and cooling (HVAC) systems, component cooling water system (CCS), normal residual heat removal system (RNS) and service water system (SWS). The integrated performance of the safety-related and non-safety related systems ensures the safe and efficient operation of the Westinghouse SMR through various conditions and transients. The turbine island consists of the turbine, electric generator, feedwater and steam systems, moisture separation systems, and the condensers. The BOP is designed to minimize assembly time, shipping challenges, and on-site testing requirements for all structures, systems, and components. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Westinghouse Small Modular Reactor passive safety system response to postulated events

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor. This paper is part of a series of four describing the design and safety features of the Westinghouse SMR. This paper focuses in particular upon the passive safety features and the safety system response of the Westinghouse SMR. The Westinghouse SMR design incorporates many features to minimize the effects of, and in some cases eliminates the possibility of postulated accidents. The small size of the reactor and the low power density limits the potential consequences of an accident relative to a large plant. The integral design eliminates large loop piping, which significantly reduces the flow area of postulated loss of coolant accidents (LOCAs). The Westinghouse SMR containment is a high-pressure, compact design that normally operates at a partial vacuum. This facilitates heat removal from the containment during LOCA events. The containment is submerged in water which also aides the heat removal and provides an additional radionuclide filter. The Westinghouse SMR safety system design is passive, is based largely on the passive safety systems used in the AP1000{sup R} reactor, and provides mitigation of all design basis accidents without the need for AC electrical power for a period of seven days. Frequent faults, such as reactivity insertion events and loss of power events, are protected by first shutting down the nuclear reaction by inserting control rods, then providing cold, borated water through a passive, buoyancy-driven flow. Decay heat removal is provided using a layered approach that includes the passive removal of heat by the steam drum and independent passive heat removal system that transfers heat from the primary system to the environment. Less frequent faults such as loss of coolant accidents are mitigated by passive injection of a large quantity of water that is readily available inside containment. An automatic depressurization system is used to reduce the reactor pressure in a controlled manner to facilitate the passive injection. Long-term decay heat removal is accomplished using the passive heat removal systems augmented by heat transfer through the containment vessel to the environment. The passive injection systems are designed so that the fuel remains covered and effectively cooled throughout the event. Like during the frequent faults, the passive systems provide effective cooling without the need for ac power for seven days following the accident. Connections are available to add additional water to indefinitely cool the plant. The response of the safety systems of the Westinghouse SMR to various initiating faults has been examined. Among them, two accidents; an extended station blackout event, and a LOCA event have been evaluated to demonstrate how the plant will remain safe in the unlikely event that either should occur. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Single Tower Configuration of the Modular Gamma Box Counter System - 13392

Canberra's Standard Gamma Box Counter System is designed to perform accurate quantitative assays of gamma emitting nuclides for a wide range of large containers including B-25 crates and ISO shipping containers. Using a modular building-block approach, the system offers tremendous flexibility for a variety of measurement situations with wide ranges of sample activities and throughput requirements, as well as the opportunity to modify the configuration for other applications at a later date. The typical configuration consists of two opposing towers each equipped with two high purity germanium detectors, and an automated container trolley. This paper presents a modified configuration, consisting of a single tower placed inside a measurement trailer with three detector assemblies, allowing for additional vertical segmentation as well as a viewing a container outside the trailer through the trailer wall. An automatic liquid nitrogen fill system is supplied for each of the detectors. The use of a forklift to move the container for horizontal segmentation is accommodated by creating an additional operational and calibration set-up in the NDA 2000 software to allow for the operator to rotate the container and assay the opposite side, achieving the same sensitivity as a comparable two-tower system. This Segmented Gamma Box Counter System retains the core technologies and design features of the standard configuration. The detector assemblies are shielded to minimize interference from environmental and plant background, and are collimated to provide segmentation of the container. The assembly positions can also be modified in height and distance from the container. The ISOCS calibration software provides for a flexible approach to providing the calibrations for a variety of measurement geometries. The NDA 2000 software provides seamless operation with the current configuration, handling the data acquisition and analysis. In this paper, an overview of this system is discussed, along with the measured performance results, calibration methodology and verification, and minimum detectable activity levels. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗