Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

High-throughput full-automatic synchrotron-based tomographic microscopy

At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 {micro}m to 7.4 {micro}m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 {micro}m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

43 PARTICLE ACCELERATORS↗

Collaborative Computational Project for Electron cryo-Microscopy

The Collaborative Computational Project for Electron cryo-Microscopy (CCP-EM) is a new initiative for the structural biology community, following the success of CCP4 for macromolecular crystallography. Progress in supporting the users and developers of cryoEM software is reported. The Collaborative Computational Project for Electron cryo-Microscopy (CCP-EM) has recently been established. The aims of the project are threefold: to build a coherent cryoEM community which will provide support for individual scientists and will act as a focal point for liaising with other communities, to support practising scientists in their use of cryoEM software and finally to support software developers in producing and disseminating robust and user-friendly programs. The project is closely modelled on CCP4 for macromolecular crystallography, and areas of common interest such as model fitting, underlying software libraries and tools for building program packages are being exploited. Nevertheless, cryoEM includes a number of techniques covering a large range of resolutions and a distinct project is required. In this article, progress so far is reported and future plans are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tools for macromolecular model building and refinement into electron cryo-microscopy reconstructions

A description is given of new tools to facilitate model building and refinement into electron cryo-microscopy reconstructions. The recent rapid development of single-particle electron cryo-microscopy (cryo-EM) now allows structures to be solved by this method at resolutions close to 3 Å. Here, a number of tools to facilitate the interpretation of EM reconstructions with stereochemically reasonable all-atom models are described. The BALBES database has been repurposed as a tool for identifying protein folds from density maps. Modifications to Coot, including new Jiggle Fit and morphing tools and improved handling of nucleic acids, enhance its functionality for interpreting EM maps. REFMAC has been modified for optimal fitting of atomic models into EM maps. As external structural information can enhance the reliability of the derived atomic models, stabilize refinement and reduce overfitting, ProSMART has been extended to generate interatomic distance restraints from nucleic acid reference structures, and a new tool, LIBG, has been developed to generate nucleic acid base-pair and parallel-plane restraints. Furthermore, restraint generation has been integrated with visualization and editing in Coot, and these restraints have been applied to both real-space refinement in Coot and reciprocal-space refinement in REFMAC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simultaneous X-ray fluorescence and scanning X-ray diffraction microscopy at the Australian Synchrotron XFM beamline

Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale deformation analysis with high-resolution transmission electron microscopy and digital image correlation

We present an application of the digital image correlation (DIC) method to high-resolution transmission electron microscopy (HRTEM) images for nanoscale deformation analysis. The combination of DIC and HRTEM offers both the ultrahigh spatial resolution and high displacement detection sensitivity that are not possible with other microscope-based DIC techniques. We demonstrate the accuracy and utility of the HRTEM-DIC technique through displacement and strain analysis on amorphous silicon. Two types of error sources resulting from the transmission electron microscopy (TEM) image noise and electromagnetic-lens distortions are quantitatively investigated via rigid-body translation experiments. The local and global DIC approaches are applied for the analysis of diffusion- and reaction-induced deformation fields in electrochemically lithiated amorphous silicon. As a result, the DIC technique coupled with HRTEM provides a new avenue for the deformation analysis of materials at the nanometer length scales.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Molecular beam epitaxial growth and scanning tunneling microscopy studies of the gallium rich trench line structure on N-polar w-GaN( 000 1 ¯ )

In addition to the usual set of the well-known reconstructions that have been observed on the N-polar GaN surface, namely 1×1, 3×3, 6×6, and c(6×12), an additional structure is occasionally seen at high Ga coverage, which can extend over a large area of the surface. This structure, which is referred to as trench line structure, is partially ordered and consists of parallel-running dark (trench) lines separating wide and narrow strips of atomically ordered regions. There are also randomly placed defects interrupting the ideal ordering. Reflection high energy electron diffraction and scanning tunneling microscopy in ultrahigh vacuum are applied to investigate this trench line structure on samples prepared using molecular beam epitaxy. It is found that the trench line structure results from annealing the Ga-rich c(6×12) at high temperature followed by quenching to room temperature. By careful comparison of the scanning tunneling microscopy images with those from neighboring c(6×12) regions, it is found that the trench line structure can be decomposed into subunits of the c(6×12). Using these subunits, some simple models for the trench line structure are created. It is proposed that the trench line structure is composed of two primary c(6×12) subunits consisting of first and second layer Ga adatoms and that the trench lines are regions devoid of Ga adatoms, going down to the Ga adlayer.

36 MATERIALS SCIENCE↗

SU-F-T-665: Confocal Microscopy Imaging of Cell Cycle Distribution in Cells Treated with Pegylated Gold Nanoshells

Purpose: To use confocal microscopy to distinguish cells in different phases of the cell cycle before and after treatment with pegylated gold nanoshells (PEG-AuNSs). Methods: Transfected fibrosarcoma cells (HT1080-EYFP-53BP1-FUCCI) were cultured in T-25 flasks and seeded in glass bottom dishes. These cells express the fluorescent probe AmCyan during the G2/S phases of the cell cycle, mCherry during the G1 phase, and EYFP tagged to the DNA repair protein 53BP1. After allowing cells 4 h to adhere to dishes, PEG-AuNS (Nanospectra Biosciences, Houston, TX) at a concentration of 0.15 OD were administered. At time points of 8, 16 and 24 h following treatment, the PEG-AuNS-treated and control samples were washed with phosphate buffered saline (PBS) and fixed using 4% paraformaldehyde in PBS. Samples were imaged with an Olympus FV1200 confocal microscope using 473, 543, and 641 nm excitation lasers. We used band-pass filters to select AmCyan and mCherry fluorescence. Reflection from the 641 nm laser was used to detect PEG-AuNSs. Z-stack images were analyzed to assess cell cycle distribution through fluorescent probe expression. Live cells were imaged after PEG-AuNS treatment using a confocal microscope with a stage top CO2 incubator. Results: We were able to obtain high-resolution images of cells with internalized AuNSs. We were also able to distinguish cells in different phases of the cell cycle. Conclusion: This work demonstrates a new assay to investigate the effect of AuNSs on the cell cycle phase in live cells. Future work will employ confocal microscopy and flow cytometry to focus on effects of AuNS treatment on cell cycle distribution. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Direct visualization of electromagnetic wave dynamics by laser-free ultrafast electron microscopy

Integrating femtosecond lasers with electron microscopies has enabled direct imaging of transient structures and morphologies of materials in real time and space. Here, we report the development of a laser-free ultrafast electron microscopy (UEM) offering the same capability but without requiring femtosecond lasers and intricate instrumental modifications. We create picosecond electron pulses for probing dynamic events by chopping a continuous beam with a radio frequency (RF)–driven pulser with the pulse repetition rate tunable from 100 MHz to 12 GHz. As a first application, we studied gigahertz electromagnetic wave propagation dynamics in an interdigitated comb structure. We reveal, on nanometer space and picosecond time scales, the transient oscillating electromagnetic field around the tines of the combs with time-resolved polarization, amplitude, and local field enhancement. This study demonstrates the feasibility of laser-free UEM in real-space visualization of dynamics for many research fields, especially the electrodynamics in devices associated with information processing technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Specific features of sample preparation from amorphous aluminum alloys for transmission electron microscopy

An aluminum amorphous alloy doped with transition (Fe and Ni) and rare earth (La) metals has been used as an object of systematic study of the structural transformations that are characteristic of different methods of sample preparation for transmission electron microscopy (the mechanical tearing of ribbons, electrochemical thinning, and Ar{sup +}-ion etching under different conditions). The results of X-ray diffraction analysis and a calorimetric study of the structure in comparison with electron microscopy data made it possible to determine the optimal method of sample preparation, which ensures minimum distortions in the structure of metastable amorphous alloys with a low crystallization temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron microscopy of phase and structural transformations in soft magnetic nanocrystalline Fe-Zr-N films

The effect of deposition conditions (film thickness) on the structure of soft magnetic Fe{sub 80-78}Zr{sub 10}N{sub 10-12} films formed by reactive magnetron deposition on a heat-resistant glass substrate has been investigated by analytical transmission electron microscopy, high-resolution electron microscopy, and diffraction analysis. The processes of evolution of the phase and structural state of films and the film-substrate interface upon annealing in the temperature range of 200-650 Degree-Sign C have been analyzed taking into account the thermodynamic, kinetic, and structural factors and the specific features of the nanocrystalline state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of the surface heterogeneity of topographic and electric nature by atomic force microscopy by the example of triglycine sulfate

Triglycine sulfate crystals with an ideal (010) cleavage plane are used as model objects to reveal problems in interpreting atomic force microscopy (AFM) images of surfaces with nonuniform charge distribution. Specific microrelief features of two types are found: lenslike formations with different contrast and rounded protrusions/valleys of different size but fixed height. An analysis of their evolution with a change in temperature and under an electric field and mechanical impacts has made it possible to separate relief elements from the crystal domain structure. The interpretation proposed is confirmed by the multimode AFM data. The specific features of the images of dynamic domains and aged domains (which cannot undergo polarization reversal) are studied. The domain-wall width found in the AFM measurements depends on the technique used and the specificity of probe-surface interaction; it varies from 9 to 2000 nm. The most reliable data on the domain-wall width in triglycine sulfate crystals are provided by piezoelectric force microscopy, according to which the wall width does not exceed 30 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Porosity and structural parameters of Karelian shungites according to the data of small-angle synchrotron radiation scattering and microscopy

The nanoporosity and structure of natural carbons has been investigated on the example of Karelian carbon-rich shungites by comparing the data of small-angle synchrotron radiation scattering and highresolution microscopy. The analysis of small-angle scattering data is based on the model of scattering spheres with lognormal size distribution. It is found that the structure of samples from the Maksovo and Zazhogino deposits subjected to high temperatures in the geological medium and (also to a lesser extent) a sample from the Shunga deposit can be described as an aggregation of polydisperse scattering spheres with lognormal size distribution; the characteristic scatterer size is determined for them. A comparison with microscopy data shows that these scatterers are mainly associated with pores, and the character of their size distribution is similar to that previously established for nanoglobules in schungites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-voltage scanning electron microscopy of multilayer polymer systems

The possibilities of low-voltage scanning electron microscopy for visualization of specific features of the microstructure in internal layers of multilayer polymer films are demonstrated by the example of “chitosan–polyelectrolyte complex–alginic acid” composite. The process of electron beam interaction with a sample at low electron energies is considered. The key parameters of low-voltage electron microscopy, which make it possible to increase the resolution of SEM images of polymer systems, are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnification Effects in Scanning Tunneling Microscopy: the Role of Surface Radicals

Scanning tunneling microscopy (STM) is a fundamental tool for determination of the surface atomic structure. However, the interpretation of high resolution microscopy images is not straightforward. In this paper we provide a physical insight on how STM images can suggest atomic locations which are distinctively different from the real ones. This effect should be taken into account when interpreting high-resolution STM images obtained on surfaces with directional bonds. It is shown that spurious images are formed in the presence of polarized surface radicals showing a pronounced angle with respect to the surface normal. This issue has been overlooked within the surface science community and often disregarded by experimentalists working with STM. Without loss of generality, we illustrate this effect by the magnification observed for pentamer-like structures on (110), (113), and (331) surfaces of silicon and germanium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of Time-of-Flight Chromatic Aberration on the Dynamics of Propagation of Pulsed Electron Beam in Ultrafast Electron Microscopy: A New Strategy for Better Temporal Resolution

A common strategy aimed at achieving a high temporal resolution in ultrafast electron microscopy and diffraction is based on the use of strong electrostatic fields in the accelerating gap to form fast electron pulses of ultrashort duration. In this work, the dynamics of the propagation of ultrashort photoelectron bunches is studied taking into account the time-of-flight chromatic aberration: the spread-out of electron pulses at the exit from the region of the accelerating electric field. The results of the calculation of the duration of photoelectron pulses taking into account Coulomb repulsion are presented. According to the analysis, the use of strong electrostatic fields in the accelerating gap for the formation of fast electron pulses of ultrashort duration is not a necessary condition for achieving the final high temporal resolution in the method of ultrafast electron microscopy. The modes of operation of ultrafast transmission electron microscope were found for which the temporal resolution increases with the growth of time-of-flight chromatic aberration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic Force Microscopy Measurement of the Resistivity of Semiconductors

The surface of silicon substrates has been studied experimentally and theoretically by the method of atomic force microscopy spreading resistance imaging, and measuring techniques for the spreading resistance of semiconductors have been developed based on these data. It has been shown that the resistivity of silicon can be determined reliably if the force with which the probe is pressed against the substrate exceeds some threshold. The influence of the environment on the values of currents in the probe–substrate system has been studied. It has been found that the electrical performance of semiconductors can be properly determined by atomic force microscopy spreading resistance imaging under high-vacuum conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Energy X-Ray Diffraction Microscopy in Materials Science

High-energy diffraction microscopy (HEDM) is an implementation of three-dimensional X-ray diffraction microscopy. HEDM yields maps of internal crystal orientation fields, strain states, grain shapes and locations as well as intragranular orientation distributions, and grain boundary character. Because it is nondestructive in hard materials, notably metals and ceramics, HEDM has been used to study responses of these materials to external fields including high temperature and mechanical loading. Currently available sources and detectors lead to a spatial resolution of ~1 μm and an orientation resolution of <0.1°. With the penetration characteristic of high energies ( E ≥ 50 keV), sample cross-section dimensions of ~1 mm can be studied in materials containing elements across much of the Periodic Table. This review describes hardware and software associated with HEDM as well as examples of applications. Overall, these applications include studies of grain growth, recrystallization, texture development, orientation gradients, deformation twinning, annealing twinning, plastic deformation, and additive manufacturing. We also describe relationships to other X-ray-based methods as well as prospects for further development.

36 MATERIALS SCIENCE↗

Vibration measurement of a miniature component by high-speed image-plane digital holographic microscopy

Measuring deformation of vibrating specimens whose dimensions are in the submillimeter range introduces a number of difficulties using laser interferometry. Normal interferometry is not suitable because of a phase ambiguity problem. In addition, the noise effect is much more serious in the measurement of small objects because a high-magnification lens is used. We present a method for full-field measurement of displacement, velocity, and acceleration of a vibrating miniature object based on image-plane digital holographic microscopy. A miniature cantilever beam is excited by a piezoelectric transducer stage with a sinusoidal configuration. A sequence of digital holograms is captured using a high-speed digital holographic microscope. Windowed Fourier analysis is applied in the spatial and spatiotemporal domains to extract the displacement, velocity and acceleration. The result shows that a combination of image-plane digital holographic microscopy and windowed Fourier analyses can be used to study vibration without encountering a phase ambiguity problem, and one can obtain instantaneous kinematic parameters on each point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗