Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

The System for on-Axis Neutrino Detection at the DUNE Near Detector complex

The Deep Underground Neutrino Experiment Near Detector complex aims at constraining the systematic uncertainties and deconvolving the neutrino beam flux and cross-section models. The System for on-Axis Neutrino Detection (SAND) is the Near Detector component permanently on-axis. SAND is based on the 0.6 T superconducting magnet and electromagnetic calorimeter previously used in the KLOE experiment. The 40 m3 magnetic volume will be filled with an active target/tracker system. One considered option foresees an upstream liquid Argon active target (about 1.5 t) and a Straw Tube Tracker (about 5 t). In this talk the design of SAND will be described and its performances discussed in view of the SAND primary goals, namely the beam monitoring and neutrino flux measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedded, Real-Time, and Distributed Traveling Wave Fault Location Method Using Graph Convolutional Neural Networks

This work proposes and develops an implementation of a fault location method to provide a fast and resilient protection scheme for power distribution systems. The method analyzes the transient dynamics of traveling waves (TWs) to generate features using the discrete wavelet transform (DWT), which are then used to train several graph convolutional network (GCN) models. Faults are simulated in the IEEE 34-node system, which is divided into three protection zones (PZs). The goal is to identify the PZ in which the fault occurs. The GCN models create a distributed protection scheme, as all nodes are able to retrieve a prediction. Given that message-passing between nodes occurs both during training and in the execution of the model, the resiliency of such schemes to communication losses was analyzed and demonstrated. One of the models, which only uses voltage measurements, was implemented on a Texas Instruments F28379D development board. The execution times were monitored to assess the speed of the protection scheme. It is shown that the proposed method can be executed in approximately a millisecond, which is comparable to existing TW protection in the transmission system. For experimental purposes, a DWT-based detection method is employed. A design of a setup to playback TWs using two development boards is also addressed.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

The Milky Way Stellar Halo Is Twisted and Doubly Broken: Insights from DESI DR2 Milky Way Survey Observation

Using K giants from the second data release (DR2) of the Dark Energy Spectroscopic Instrument (DESI) Milky Way Survey, we measure the shape, orientation, radial profile, and density anisotropies of the Milky Way (MW) stellar halo over 8 kpc < r GC < 200 kpc. We identify a triaxial stellar halo (axis ratio 10:8:7), 43° tilted from the disk, showing two break radii at ∼16 and ∼76 kpc, likely associated with Gaia-Sausage/Enceladus and the Large Magellanic Cloud (LMC), respectively. The inner stellar halo (<30 kpc) is oblate and aligned with the disk, whereas the outer stellar halo becomes prolate and perpendicular to the disk, consistent with the vast polar structure of MW satellites. The twisted halo may arise from the disk−halo angular momentum shift triggered by the infall of a massive satellite. The anisotropic density distribution of the stellar halo is also measured, with successful reidentification of the Hercules-Aquila Cloud North/South (HAC-N/S) overdensity and the Virgo overdensity (VOD). Break radii are found at 15 and 30 kpc for VOD and HAC-N/S, respectively. We identify the LMC transient density wake with a break radius at 60 kpc in the Pisces overdensity region. We also find new observational evidence of the LMC collective density wake, by showing a break radius at ∼100 kpc in the northern Galactic cap with a clear density peak at 90 kpc. In the end, we found that more metal-poor halo stars are more radially extended. Our results provide important clues to the assembly and evolution of the MW stellar halo under the standard cosmic structure formation framework.

Li, Songting [Shanghai Jiao Tong Univ. (China); DE↗

Probing Physics beyond the Standard Model through Combined Analyses of Next-generation Type Ia Supernova, Cosmic Microwave Background, and Baryon Acoustic Oscillation Surveys

Observations of Type Ia supernovae (SNe Ia), which probe the late Universe, together with baryon acoustic oscillations (BAO) and the cosmic microwave background (CMB), which probe the intermediate and early epochs, provide complementary constraints on the expansion history of the Universe. In this work, we forecast constraints on dark energy and other extensions to the standard cosmological model by combining the SN Ia sample expected from the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST), data from current and forthcoming CMB surveys, and BAO measurements from the Dark Energy Spectroscopic Instrument (DESI). For the CMB, we use temperature, polarization, and lensing power spectra (TT/EE/TE/ϕϕ) from the South Pole Telescope, the planned Advanced Simons Observatory, and a CMB-S4–like experiment. We derive constraints on ΛCDM and its extensions involving the dark energy equation-of-state parameters (w 0 , w a ) and the sum of neutrino masses ∑m ν using a Markov Chain Monte Carlo (MCMC) sampling framework. We find that the LSST Year 3 SN Ia sample can improve upon the DES Year 5 dark energy constraints by a factor of 2−2.5×, with the gains driven primarily by the significantly higher SN Ia density in the LSST sample. Similarly, DESI-DR3 shows up to a 1.8× improvement on dark energy parameters over DR2, driven largely by the substantial increase in the low-redshift sample. Combining CMB with LSST-Y3-SN Ia and DESI-DR3-BAO yields σ(w 0 ) = 0.028 and σ(w a ) = 0.11 for w 0 w a CDM cosmology with the results being largely independent of the CMB dataset. The constraints weaken by 10%–30% when freeing ∑m ν and spatial curvature. Moreover, the joint analysis of the three datasets can enable a 2σ–3σ detection of ∑m ν .

Raghunathan, Srinivasan [University of California;↗

NCSU Flux Tower Data

NCSU Flux Tower Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument descripotion Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Sonic Anemometer, 3 Condensation Particle Counters, 1 SP2, 1 POPS Start Date: 2022-06-01 End Date: 2022-9-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU flux tower was located next to the AMF sampling pad. The flux tower consisted of a 10 m telescoping tower. Mounted at the top of the tower was a sonic anemometer (RM Young 8000) and a Krypton Hygrometer. A sample line (¼” conductive tubing) and communication line was laid to a trailer located underneath and slightly adjacent to the tower. The sample line brought aerosol inside the trailer at 4.5 L min-1, where it was distributed between 3 CPCs (TSI 3776c, Dc ~ 2.5 nm, TSI 3771, Dc ~10nm, and TSI 3772, Dc ~40 nm) with different size cuts. Also sampling was a printed particle optical spectrometer (POPS) and a single particle soot photometer (SP2). Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

NCSU RDMA data

NCSU RDMA Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Nano-Scanning Mobility Particle (SMPS); A Radial Differential Mobility Analyzer (RDMA) coupled with 1 Condensation Particle Counter Start Date: 2022-06-01 End Date: 2022-9-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU RDMA was operated at a sheath-to-sample flow ratio of 5:1.5 L min−1. The RDMA was configured to scan from 5 to 55 nm. It was located into the temperature-controlled trailer adjacent to the NCSU Flux Tower to observe size distributions of the aerosols.The sample line was dried with three silica-gel driers in series, and then neutralized with X-ray neutralizer. Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

NCSU Black Carbon (SP2) Data

NCSU SP2 Data Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Single Particle Soot Photometer (SP2) Start Date: 2022-06-01 End Date: 2022-09-27 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The SP2 was located in the temperature-controlled trailer adjacent to the NCSU Flux Tower to observe refractory black carbon (rBC) number concentration and mixing states of black carbon. The sample line brought aerosol inside the trailer at 4.5 L min-1, where it was distributed between 3 CPCs (TSI 3776c, Dc ~ 2.5 nm, TSI 3771, Dc ~10nm, and TSI 3772, Dc ~40 nm) with different size cuts, a printed particle optical spectrometer (POPS), and SP2. Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared photon-number-resolving imager using a Skipper-CCD

Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an imaging device in the infrared wavelength range able to arbitrarily reduce the readout noise. We built a Measured Exposure Skipper-CCD Sensor Instrument equipped with a thick back-illuminated sensor, with photon-number-resolving capability in a wide dynamic range, spatial resolution, high quantum efficiency in the near-infrared and ultra-low dark counts. This device allows us to image objects in a broad range of intensities within the same frame and, by reducing the readout noise to less than 0.2e$^-$, to distinguish even those shapes with less than two photons per pixel, unveiling what was previously hidden in the noise. These results pave the way for building high-standard infrared imagers based on Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-visual analysis of miniaturized melt wire arrays for in-pile measurement of peak irradiation temperature

As a part of the in-pile instrumentation program, the Idaho National Laboratory (INL) has established in-house capabilities to fabricate and test new advanced manufactured printed sensors for measurement of peak temperature inside the harsh environment of a nuclear test reactor. Although nuclear test reactors may use standard methods that can provide real-time temperature information, such as thermocouples, the need for feedthroughs for real-time measurements greatly increases the cost of the experiment. Some experiments also present the problem of limited space available for instrumentation. To address this need, INL is working to improve temperature detection options for such applications. The lab is developing advanced manufactured melt wire arrays to determine peak temperatures in experiments with limited space. Furthermore, capabilities to print multiple melt wires with different melting properties on a single miniaturized unit is being established. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing.

36 MATERIALS SCIENCE↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

Characterization of 244 Cm Neutron Sources

There is a need to find a replacement for the 252 Cf sources currently used in Standards-based performance testing of neutron instrumentation. This is a result of its relatively short half-life, concerns about future availability and recent increases in cost. A potential replacement source, 244 Cm is evaluated in this study where two commercially available sources have been acquired and their neutron emission spectra measured using a pair of spectrometers. Both instruments showed the 244 Cm spontaneous neutron spectrum to be fully consistent with a MCNP6®-calculated spectrum using published Watt fission parameters for 244 Cm. In addition, the emission rate of the weaker 244 Cm source was established through a direct count rate comparison against a calibrated and similarly encapsulated 252 Cf source. The 244 Cm source emission rate was found to be in excellent agreement with value stated on the manufacturer's source certificate. It is concluded that 244 Cm would be an ideal replacement for 252 Cf based on its longer half-life (18.1 y) and its essentially identical neutron emission spectrum. In addition, 244 Cm sources are commercially available at reasonable cost.

244Cm↗

The Dark Energy Spectroscopic Instrument: one-dimensional power spectrum from first Ly α forest samples with Fast Fourier Transform

ABSTRACT We present the one-dimensional Ly α forest power spectrum measurement using the first data provided by the Dark Energy Spectroscopic Instrument (DESI). The data sample comprises 26 330 quasar spectra, at redshift z > 2.1, contained in the DESI Early Data Release and the first 2 months of the main survey. We employ a Fast Fourier Transform (FFT) estimator and compare the resulting power spectrum to an alternative likelihood-based method in a companion paper. We investigate methodological and instrumental contaminants associated with the new DESI instrument, applying techniques similar to previous Sloan Digital Sky Survey (SDSS) measurements. We use synthetic data based on lognormal approximation to validate and correct our measurement. We compare our resulting power spectrum with previous SDSS and high-resolution measurements. With relatively small number statistics, we successfully perform the FFT measurement, which is already competitive in terms of the scale range. At the end of the DESI survey, we expect a five times larger Ly α forest sample than SDSS, providing an unprecedented precise one-dimensional power spectrum measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring cosmological distances using cluster edges as a standard ruler

ABSTRACT The line-of-sight velocity dispersion profile of galaxy clusters exhibits a ‘kink’ corresponding to the spatial extent of orbiting galaxies. Because the spatial extent of a cluster is correlated with the amplitude of the velocity dispersion profile, we can utilize this feature as a gravity-calibrated standard ruler. Specifically, the amplitude of the velocity dispersion data allows us to infer the physical cluster size. Consequently, observations of the angular scale of the ‘kink’ in the profile can be translated into a distance measurement to the cluster. Assuming the relation between cluster radius and cluster velocity dispersion can be calibrated from simulations, we forecast that with existing data from the Sloan Digital Sky Survey we will be able to measure the Hubble constant with 3.0 per cent precision. Implementing our method with data from the Dark Energy Spectroscopic Instrument (DESI) will result in a 1.3 per cent measurement of the Hubble constant. Adding cosmological supernova data improves the uncertainty of the DESI measurement to 0.7 per cent. While these error estimates are statistical only, they provide strong motivation for pursuing the necessary simulation program required to characterize and calibrate the systematic uncertainties impacting our proposed measurement. Whether or not our proposed measurement can in fact result in competitive H0 constraints will depend on what the eventual systematics floor for this method is.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring the Conditional Luminosity and Stellar Mass Functions of Galaxies by Combining the Dark Energy Spectroscopic Instrument Legacy Imaging Surveys Data Release 9, Survey Validation 3, and Year 1 Data

In this investigation, we leverage the combination of the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys Data Release 9, Survey Validation 3, and Year 1 data sets to estimate the conditional luminosity functions and conditional stellar mass functions (CLFs and CSMFs) of galaxies across various halo mass bins and redshift ranges. To support our analysis, we utilize a realistic DESI mock galaxy redshift survey (MGRS) generated from a high-resolution Jiutian simulation. An extended halo-based group finder is applied to both MGRS catalogs and DESI observation. By comparing the r- and z-band luminosity functions (LFs) and stellar mass functions (SMFs) derived using both photometric and spectroscopic data, we quantified the impact of photometric redshift (photo-z) errors on the galaxy LFs and SMFs, especially in the low-redshift bin at the low-luminosity/mass end. By conducting prior evaluations of the group finder using MGRS, we successfully obtain a set of CLF and CSMF measurements from observational data. We find that at low redshift, the faint-end slopes of CLFs and CSMFs below ~10 9 h –2 L ⊙ (or h –2 M ⊙ ) evince a compelling concordance with the subhalo mass functions. After correcting the cosmic variance effect of our local Universe following Chen et al., the faint-end slopes of the LFs/SMFs turn out to also be in good agreement with the slope of the halo mass function.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of methods to determine the surface mixing layer height of the atmospheric boundary layer in the central Arctic during polar night and transition to polar day in cloudless and cloudy conditions

This study evaluates methods to derive the surface mixing layer (SML) height of the Arctic atmospheric boundary layer (ABL) using in situ measurements inside the Arctic ABL during winter and the transition period to spring. An instrumental payload carried by a tethered balloon was used for the measurements between December 2019 and May 2020 during the year-long Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition. Vertically highly resolved (centimeter scale) in situ profile measurements of mean and turbulent parameters were obtained, reaching from the sea ice to several hundred meters above ground. Two typical conditions of the Arctic ABL over sea ice were identified: cloudless situations with a shallow surface-based inversion and cloudy conditions with an elevated inversion. Both conditions are associated with significantly different SML heights whose determination as accurately as possible is of great importance for many applications. We used the measured turbulence profile data to define a reference of the SML height. With this reference, a more precise critical bulk Richardson number of 0.12 was derived, which allows an extension of the SML height determination to regular radiosoundings. Furthermore, we have tested the applicability of the Monin–Obukhov similarity theory to derive SML heights based on measured turbulent surface fluxes. The application of the different approaches and their advantages and disadvantages are discussed.

54 ENVIRONMENTAL SCIENCES↗

The Simons Observatory: HoloSim-ML: machine learning applied to the efficient analysis of radio holography measurements of complex optical systems

Near-field radio holography is a common method for measuring and aligning mirror surfaces for millimeter and sub-millimeter telescopes. In instruments with more than a single mirror, degeneracies arise in the holography measurement, requiring multiple measurements and new fitting methods. We present HoloSim-ML, a Python code for beam simulation and analysis of radio holography data from complex optical systems. This code uses machine learning to efficiently determine the position of hundreds of mirror adjusters on multiple mirrors with few micron accuracy. We apply this approach to the example of the Simons Observatory 6m telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗