Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Material Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Hybrid statistical testing for nuclear material accounting data and/or process monitoring data in nuclear safeguards

The aim of nuclear safeguards is to ensure that special nuclear material is used for peaceful purposes. Historically, nuclear material accounting (NMA) has provided the quantitative basis for monitoring for nuclear material loss or diversion, and process monitoring (PM) data is collected by the operator to monitor the process. PM data typically support NMA in various ways, often by providing a basis to estimate some of the in-process nuclear material inventory. We develop options for combining PM residuals and NMA residuals (residual = measurement - prediction), using a hybrid of period-driven and data-driven hypothesis testing. The modified statistical tests can be used on time series of NMA residuals (the NMA residual is the familiar material balance), or on a combination of PM and NMA residuals. The PM residuals can be generated on a fixed time schedule or as events occur.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-sized specimen testing and its relationship with Gen IV Materials Qualification

Renewed interest in advanced reactor technologies which can produce inherently safe, reliable, low carbon, low cost energy requires the development of new materials which can operate in the extreme environments proposed by Gen IV reactor designs. The primary focus of the Nuclear Materials Discovery and Qualification Initiative (NMDQi) is to accelerate the process by which new materials can make their way into commercial use, enabling new technologies and innovations within the nuclear sector. Due to limitations in the production of neutron irradiated material for testing and qualification, the use of specimens far smaller than those traditionally called for in regulatory codes becomes a necessity. While the use of these sub-sized specimens is necessary to achieve materials qualification on a realistic timeline and budget, literature showing the efficacy of these samples as an appropriate surrogate for ASME/ASTM defined samples is limited. This poster will detail historical efforts to compare the mechanical behavior of small geometry samples with bulk material behavior and the potential of sub-sized specimen testing at INL for future materials qualification efforts.

36 MATERIALS SCIENCE↗

Spark Plasma Sintering (SPS) Update for the Fuel Conversion Effort at the Transient Reactor Test Facility

Over the lifetime of the Transient Reactor Test Facility (TREAT) reactor from 1959 to 1994, a series of historical tests disclosed certain material specific requisites for irradiation testing variables resulted in negligible structural damage after exposure to the reactor and multiple experiments. Comparable fuel design, material testing, and qualifications needs to occur for the high-enriched uranium (HEU) to low enriched uranium (LEU) fuel conversion (<20% U235) of TREAT. This includes, retaining a uniform precipitate dispersion of fueled UO2 micron-size particles throughout a graphite-moderating matrix, where high-density graphite is in direct contact with the fuel and acts as a moderator. On that note, the design of future LEU reactor TREAT fuel core will consider the relative sizing and spacing of fuel as well as the retention of graphite in accordance with the expected thermal, neutron, and energy portfolio for future conversion. In light of the above, LEU conversion fuel blocks currently being manufactured must undergo critical materials testing, irradiation, and examination to determine effects on the manufactured replacement fuel blocks at the millimeter to sub-micron size scale. Herein, we will report and update the community on value-added studies focusing on spark plasma sintering as an alternative technique to fabricate high density graphite dispersion fuel.

36 MATERIALS SCIENCE↗

Analysis of Sandwich Shells with Metallic Foam Cores based on the Uniaxial Tensile Test

On this work, the authors present the development and evaluation of an innovative system able to perform reliable panels of sandwich sheets with metallic foam cores for industrial applications, especially in automotive and aeronautical industries. This work is divided into two parts; in the first part the mathematical model used to describe the behavior of sandwich shells with metal cores form is presented and some numerical examples are presented. In the second part of this work, the numerical results are validated using the experimental results obtained from the mechanical experiments. Using the isotropic hardening crushable foam constitutive model, available on ABAQUS, a set of different mechanical tests were simulated. The isotropic hardening model available uses a yield surface that is an ellipse centered at the origin in the p-q stress plane. Using this constitutive model, the uniaxial tensile test for this material was simulated, and a comparison with the experimental results was made.

36 MATERIALS SCIENCE↗

Test plan for the irradiation of nonmetallic materials.

A comprehensive test program to evaluate nonmetallic materials use in the Hanford tank farms is described in detail. This test program determines the effects of simultaneous multiple stressors at reasonable conditions on in-service configuration components by engineering performance testing.

Brush, Laurence H.↗

Test plan for the irradiation of nonmetallic materials.

A comprehensive test program to evaluate nonmetallic materials use in the Hanford Tank Farms is described in detail. This test program determines the effects of simultaneous multiple stressors at reasonable conditions on in-service configuration components by engineering performance testing.

Brush, Laurence H.↗

Design, Fabrication and Testing of Surveillance Test Articles for MSR Materials Degradation Management

This report details the design, fabrication, and testing of surveillance test articles aimed at assessing material damage in reactor-relevant environments for effective degradation management. Two types of surveillance test articles with reduced sizes were developed based on design algorithms and finite element modeling: welded design and interlocking design. A furnace heating setup was adopted to apply multiple thermal cyclic loading profiles on the test articles with a temperature range of 500°C - 700°C, while the strain response was monitored using a digital image correlation technique. The testing results demonstrated the successful capturing of expected strain range for welded design while machining tolerance should be improved to engage strain coupling in the interlocking design. Mid-term (500 hours) and long-term (1500 hours) cyclic tests were conducted on welded test articles. A constant strain range of ~0.6% was observed at the specimen with testing under 500 hours, while a gradual decrease of strain at specimen was observed after 500 hours. Non-destructive evaluation through X-ray computed tomography confirmed the microcracks in the welds at specimen-driver joints after cyclic test that caused the strain change. Creep testing of the specimen after long-term cyclic test revealed a short creep life than expected. A multi-profile cyclic test was also conducted on a test article and demonstrated consistent strain response under different temperature ramp rates. The report also briefly discussed the challenges and future research efforts to advance test article development for material surveillance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Developing an Innovative Field Expedient Fracture Toughness Testing Protocol for Concrete Materials

The Spiral Notch Torsion Fracture Toughness Test (SNTT) was developed recently to determine the intrinsic fracture toughness (KIC) of structural materials. The SNTT system operates by applying pure torsion to uniform cylindrical specimens with a notch line that spirals around the specimen at a 45 pitch. KIC values are obtained with the aid of a three-dimensional finite-element computer code, TOR3D-KIC. The SNTT method is uniquely suitable for testing a wide variety of materials used extensively in pressure vessel and piping structural components and weldments. Application of the method to metallic, ceramic, and graphite materials has been demonstrated. One important characteristic of SNTT is that neither a fatigue precrack or a deep notch are required for the evaluation of brittle materials, which significantly reduces the sample size requirement. In this paper we report results for a Portland cement-based mortar to demonstrate applicability of the SNTT method to cementitious materials. The estimated KIC of the tested mortar samples with compressive strength of 34.45 MPa was found to be 0.19 MPa m.

36 MATERIALS SCIENCE↗

Mechanical Testing of Innovated Composite Polymer Material for using in Manufacture of Railway Sleepers

Faculty of Engineering at Shoubra has been funded to start a project for manufacturing railway sleepers from plastic wastes and iron slag to replace imported wooden sleepers. In this paper, performance of wooden sleepers in tracks of Egyptian Railways, including high cost and material defects as well as reasons to find out a new sleeper will be presented. Previous studies for using composite materials in manufacturing railway sleepers are illustrated. Mechanical testing has been carried out to determine the important properties of the new mixture; hence results are compared with the minimum requirements of the international railway standards. Linear analysis has been conducted using 3D-SAP2000 software to simulate the actual performance of the proposed sleeper. It is found that the testing results are larger than the required values. Thus; it is concluded that the tested material is effective and adequate to be used in manufacture of railway sleepers.

36 MATERIALS SCIENCE↗

Initial approaches in benchmarking and round robin testing for proton exchange membrane water electrolyzers

As ever increasing amounts of renewable electricity enter the energy supply mix on a regional, national and international basis, greater emphasis is being placed on energy conversion and storage technologies to deal with the oscillations, excess and lack of electricity. Hydrogen generation via proton exchange membrane water electrolysis (PEMWE) is one technology that offers a pathway to store large amounts of electricity in the form of hydrogen. The challenges to widespread adoption of PEMWE lie in their high capital and operating costs which both need to be reduced through R&D. An evaluation of reported performance data in literature for PEMWE reveals that there are excessive variations of in situ performance results that make it difficult to draw conclusions on the pathway forward to performance optimization and future R&D directions. In order to enable the meaningful comparison of in-situ performance evaluation across laboratories there is an obvious need for standardization of materials and testing protocols. Herein, we address this need by reporting the results of a round robin test effort conducted at the laboratories of five contributors to the IEA electrolysis annex 30. The effort utilized common sets of test articles, materials, test cells, and employed a set of shared test protocols. The maximum observed deviation between laboratories at 1 A cm-2 at cell temperatures of 60 and 80 degrees C, was 27 and 20 mV, respectively. The deviation of the results from laboratory to laboratory was a factor of 2-3 higher than the lowest deviation observed at one single lab and test station. However, the highest deviations observed were 1/10th of those extracted by a literature survey on similar material sets. The biggest takeaways are that cell temperature control appears to be the most significant source of deviation between results, while care must be taken with respect to break in conditions and cell electrical connections for meaningful performance data.

08 HYDROGEN↗

MO-F-CAMPUS-I-03: Tissue Equivalent Material Phantom to Test and Optimize Coherent Scatter Imaging for Tumor Classification

Purpose: To accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Methods: A breast phantom has been designed to assess the capability of coded aperture coherent x-ray scatter imaging system to classify different types of breast tissue (adipose, fibroglandular, tumor). The tissue-equivalent phantom was modeled as a hollow plastic cylinder containing multiple cylindrical and spherical inserts that can be positioned, rearranged, or removed to model different breast geometries. Each enclosure can be filled with a tissue-equivalent material and excised human tumors. In this study, beef and lard, placed inside 2-mm diameter plastic Nalgene containers, were used as surrogates for fibroglandular and adipose tissue, respectively. The phantom was imaged at 125 kVp, 40 mA for 10 seconds each with a 1-mm pencil beam. The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor, or momentum transfer (q) spectrum of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: The tissue equivalent phantom was found to accurately model different types of breast tissue by qualitatively comparing our measured form factors to those of adipose and fibroglandular tissue from literature. Our imaging system has been able to define the location and composition of the various materials in the phantom. Conclusion: This work introduces a new tissue equivalent phantom for testing and optimization of our coherent scatter imaging system for material classification. In future studies, the phantom will enable the use of a variety of materials including excised human tissue specimens in evaluating and optimizing our imaging system using pencil- and fan-beam geometries. United States Department of Homeland Security Duke University Medical Center - Department of Radiology Carl E Ravin Advanced Imaging Laboratories Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

SUPER HARD SURFACED POLYMERS

High energy ion beam surface treatments were applied to a selected group of polymers. Of the six materials in the present study, four were thermoplastics (polycarbonate, polyethylene, polyethylene terephthalate, and polystyrene) and two were thermosets (epoxy and polyimide). The particular epoxy evaluated in this work is one of the resins used in formulating fiber reinforced composites for military helicopter blades. Measures of mechanical properties of the near surface regions were obtained by nanoindentation hardness and pin on disk wear. Attempts were also made to measure erosion resistance by particle impact. All materials were hardness tested. Pristine materials were very soft, having values in the range of approximately 0.1 to 0.5 GPa. Ion beam treatment increased hardness by up to 50 times compared to untreated materials. For reference, all materials were hardened to values higher than those typical of stainless steels. Wear tests were carried out on three of the materials, PET, PI and epoxy. On the ion beam treated epoxy no wear could be detected, whereas the untreated material showed significant wear.

36 MATERIALS SCIENCE↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermolytic Hydrogen Generation Testing of Tank 22 Material

Savannah River National Laboratory performed hydrogen generation rate (HGR) testing using Tank 22 actual-waste sample material. The main objective of the testing was to determine the thermolysis HGR for Tank 22 material with and without added glycolate. An important use of the data from actual-waste sample testing is to validate equations for the Savannah River Site Concentration, Storage, and Transfer Facility (CSTF) HGR being developed through simulated-waste testing. Not exclusive to providing data for model validation, the desired outcome of this testing was to demonstrate a negligible thermolytic HGR in Tank 22 from the contribution of glycolate from the future Defense Waste Processing Facility (DWPF) Nitric-Glycolic Acid (NGA) flowsheet to Tank 22. Tank 22 is the pathway for glycolate in the DWPF recycle stream to enter the CSTF. Testing with added glycolate used the estimated future concentration of glycolate based on DWPF recycle with limited Sludge Receipt and Adjustment Tank and Slurry Mix Evaporator (SME) material carry-over but without glycolate mitigation in the Recycle Collection Tank. Minor objectives include the determination of the impact of the glycolate source used in testing and the inclusion of sludge solids in testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating Fracture Behavior of Bioinspired Alumina-YSZ Composites through Static and Dynamic Mechanical Testing

Ceramic materials are known for their high hardness and strength but are limited by low toughness and sudden failure. Inspired by the microstructure of dental enamel, which features undulating rods that promote crack deflection and energy absorption, architected specimens were designed and manufactured. A bespoke ball-on-ring (BoR) testing apparatus measured the static biaxial rupture strength of these bioinspired materials. Additionally, impact testing with spherical steel projectiles assessed their behavior under dynamic conditions. Monolithic alumina specimens were compared to architected alumina reinforced with yttria-stabilized zirconia (YSZ) rods produced via direct ink write 3D printing. BoR tests revealed that monolithic alumina had a Weibull modulus of 10.53 and a characteristic strength of 372.3 MPa, while the composite specimens showed a Weibull modulus of 5.46 and a characteristic strength of 213.3 MPa. Although the composite failed at lower stresses and projectile velocities, it exhibited notable crack deflection and fracture resistance, with cracks being effectively interrupted by the rod inclusions. The composite specimens also resulted in fewer and larger fragments upon impact. Finite element simulations confirmed the effectiveness of the rod structures in enhancing fracture resistance.

Bioinspired materials↗

Mini-Canister Radiolysis Testing of ASNF Materials and Surrogates

An experimental irradiation campaign to investigate radiolysis behavior of ASNF was conducted using in situ gas monitoring of small, sealed stainless-steel vessels (mini-canisters) containing aluminum samples with adherent (oxy)hydroxide films under helium backfill. The samples were irradiated with gamma radiation from a Co-60 irradiator. The samples tested included aluminum plate assemblies with lab-grown (oxy)hydroxides as surrogates for fuel as well as an end cropping from an actual ASNF assembly retrieved from long-term wet storage. These experiments enabled investigation of the impacts of various fuel drying approaches on the radiolytic generation rate and measurement of the H 2 yield associated with a reactor exposed sample with reactor-formed (oxy)hydroxide. The resulting data can be incorporated into model development for ASNF in dry storage. This report presents the cumulative results from four surrogate assemblies tested after application of different preparation (drying) conditions as well as the ASNF cropping; some post-irradiation testing was included. The mini-canister results are compared to data from related experimental campaigns that also tested the impact of drying conditions using samples irradiated in glass ampoules and discusses implications of the combined data

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistical Analysis of Low Flow Filter Efficiency Testing Results for Nuclear Material Storage Container Filters

Air filters designed to contain plutonium particulates while allowing hydrogen gas to escape are used in a variety of low flow rate applications in the nuclear industry. Examples include nuclear material storage containers, glove box bag-out bags and waste drums. Filter efficiency testing is essential to ensure filter performance, and yet the low testing flow rates present some challenges because the testing flow rates can be 5 to 6 orders of magnitude lower than those used to test large HEP A filter systems used in facility ventilation systems. Statistical analysis of low flow filter efficiency test results on nuclear material storage container filters has proven to be essential to ensure that the testing processes, test equipment, and filters meet the design requirements. This poster will describe the testing apparatus used to test nuclear material storage container filters and the use of statistical methods to analyze low flow filter efficiency test results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PUMP-STORAGE HYDROPOWER DESIGN IN A WASTEWATER TREATMENT FACILITY WITH AN AERATING RUNNER, ADDITIVE MANUFACTURED MATERIAL ANALYSIS, AND TESTING OF HYDROKINETIC TURBINE RUNNER.

The feasibility and design of a novel pumped storage system in a wastewater treatment facility is investigated. Analysis covers the added benefit of aeration, costs, and specifications. For the given sub-megawatt system, off-the-shelf runner designs are not available. This research builds on an existing pump-turbine research and design through a combination of introducing aeration into the operating processes, analysis of large format metal additive manufacturing, and testing and validation of a hydrokinetic turbine runner that uses the same response surface optimization methodology as the discussed pump-turbine design. Two concepts are generated and proposed along with a baseline scenario. Two potential site locations are provided with relevant information The Stickney Wastewater Reclamation Plant and The Navy Wastewater Treatment Plant, Joint Base Pearl Harbor-Hickam, Oahu Hawaii. Results show that aeration is the primary benefit of such a system. The system is capable of meeting the required dissolved oxygen (DO) levels in wastewater treatment. The system produces volume averaged DO levels between 1.2 and 1.4 mg/l. The system is shown to be a scalable open-loop system that can be sized for application. Area requirements of the system are acceptable due to the use of a single pedestal elevated tank The implementation timeline and nuances of this system are largely unknown. In attempt to reduce costs, advanced manufacturing methods are investigated. Investigation into advanced methods showed that mechanical properties of additive manufactured metals using a GMAW system produce equal results to wrought materials and have the potential to produce custom wear properties.

additive manufacturing↗