Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Marching Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

New Method Developed for Aeroelastic Stability Analysis

The development of advanced-design ultrahigh bypass ratio engines has led to renewed interest in the study of the flutter of bladed disks. Previously, two fundamental approaches were used in flutter calculations: frequency domain analysis and time-domain analysis. With the development of time-marching computational fluid dynamics (CFD) flow solvers, both approaches have been used with equal ease. In the present work at the NASA Lewis Research Center, substantial computational savings have been achieved by applying a numerical eigensolver to a nonlinear, time-marching fluid-structure interaction system solver for flutter prediction.

Source record↗

A viscous flow analysis of the tip vortex generation process

A viscous primary-secondary flow analysis designed for numerical solution by forward marching integration is applied to the tip vortex generation problem. Equations governing streamwise momentum, streamwise vorticity, and a gas law are solved in conjunction with equations governing scalar and vector surface potentials for the secondary velocities. The numerical method used combines a consistently split linearized block implicit (LBI) scheme for parabolic equations and a scalar iterative ADI scheme for elliptic equations. Computed results are presented for a wing of rectangular planform immersed in a high Reynolds number stream at 6 degrees incidence. The physical mechanism for generation of the tip vortex, as revealed by the analysis and computations, is discussed. Detailed flow results for the case of 6 degree incidence are included.

Shamroth, S. J.↗

River and lake ice conditions as determined from AIRSAR imagery

Synthetic aperture radar (SAR) imagery data can provide information on types and distribution of river and lake ice needed for studying river ice processes and dynamics, monitoring ice during winter navigation, and formulating ice control strategies. Visible and IR remote sensing systems cannot provide such data and present field methods are inadequate for characterizing ice conditions over long river reaches. Our ongoing analysis of JPL's AIRSAR imagery data and concurrent ground truth of ice conditions on the Tanana River and surrounding lakes near Fairbanks, Alaska, in March 1988, has resulted in several findings: hummocked ice covers and zones of variable ice surface roughness within them can be differentiated; C- and L-band data are more sensitive than P-band to the range of surface roughnesses encountered; smooth, level ice that is clear or contains small bubbles produces little backscatter; snow-covered river ice, whether rough or smooth, is distinguishable from snow-covered river sediments on exposed river beds and unvegetated bars; and open water leads are readily distinguished.

Melloh, Rae A.↗

Non-LTE spectral analysis and model constraints on SN 1993J

We present non-Local Thermodynamic Equilibrium (LTE) synthetic spectra for a time series of observations of SN 1993J obtained on 1993 March 30-31, April 7, April 13-15, and June 13 UT. The spectra are dominated by hydrogen Balmer lines; neutral helium lines, which have been nonthermally excited; and Fe II features. The density profile evolves from an extremely steep 'brick wall' structure with an equivalent power-law index of about 50 on March 30 to a more typical SN II profile with a power law index of about 10. The early spectra are well fitted by a solar composition of metals, although an enhanced abundance of helium is required in order to fit the neutral helium lines. By June 13, the photosphere has receded deep into the helium layer, although there appears to be a layer of hydrogen at higher velocity. The distance is estimated for each epoch. While consistent results are found for spectra obtained in the month of April, the spread in distances from March to June is quite large. Our value for April is mu = 28.0 +/- 0.3 mag, consistent with the recent Cepheid distance to the host galaxy M81. We also compare our results to other implementations of the expanding photosphere method.

Baron, E.↗

Narrow-Band Imaging Improves Detection of Colorectal Peritoneal Metastases: A Clinical Study Comparing Advanced Imaging Techniques

Background: Colorectal peritoneal metastases (PM) are often diagnosed in an advanced disease stage. Cytoreduction and hyperthermic intraperitoneal chemotherapy (HIPEC) improve survival of patients with colorectal PM, although most benefit is seen in patients with limited peritoneal disease. Advanced imaging techniques might improve the detection of PM, potentially leading to earlier diagnosis and improved cytoreduction. This prospective clinical trial compared three advanced techniques with conventional white-light imaging for the detection of colorectal PM: narrow-band imaging (NBI), near-infrared indocyanine green fluorescent imaging (NIR-ICG), and spray-dye chromoendoscopy (SDCE). Methods: Patients with colorectal PM were prospectively included. Prior to cytoreduction and HIPEC, all abdominal regions were inspected with white-light imaging, NBI, NIR-ICG, and SDCE during exploratory laparoscopy. Primary endpoints were sensitivity and specificity for the detection of PM, using pathological examination of biopsied lesions as the reference standard. The safety of all techniques was assessed. Results: Between May 2016 and March 2018, four different techniques were analyzed in 28 patients, resulting in 169 biopsies. Sensitivity for the detection of PM significantly increased from 80.0% with white light to 96.0% with NBI (p = 0.008), without loss of specificity (74.8% vs. 73.1%, respectively, p = 0.804). The use of NIR-ICG and SDCE was discontinued after 10 patients had undergone treatment because the lesions were not fluorescent using NIR-ICG, and because SDCE did not visualize the whole peritoneum. No adverse events relating to the imaging techniques occurred. Conclusion: NBI substantially increased the detection of PM. This method is safe and could improve the detection of metastatic lesions and help optimize cytoreduction in patients with colorectal PM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indonesian Highly Enriched Uranium-Bearing Waste Elimination - 17393

The Department of Energy's National Nuclear Security Administration (NNSA) and the Y-12 National Security Complex (Y-12) have been working with PT Industri Nuklir Indonesia (PT Inuki), an Indonesian medical isotope producer, since 2014 to disposition all highly enriched uranium (HEU) stored at the government-owned Research Center for Science and Technology (PUSPIPTEK) near Serpong, Indonesia. To eliminate the 1.5 kilograms of liquid HEU at the facility, Y-12 proposed a method to down-blend the leftover process solutions with a depleted uranium solution made on-site to render low-enriched uranium (LEU). This method is essentially irreversible since the uranium enrichment is degraded using a molecular level of intimate mixing in aqueous solution. This cooperation was tied to a presidential commitment made at the 2016 Nuclear Security Summit to down-blend all remaining HEU in Indonesia by September 2016. While all unirradiated HEU was down-blended to LEU in March 2016, the campaign to down-blend the 1.4 kilograms of irradiated HEU began in late July 2016 and was completed in August, making Indonesia and all of Southeast Asia free of HEU. As part of this cooperation, Y-12 and NNSA also proposed a subsequent disposition option for the LEU solution whereby the irradiated and unirradiated solutions will be chemically manipulated to prepare a dry LEU oxide suitable for interim storage and yield a uranium-free liquid stream that can be discarded as radioactive waste. In the fall of 2016, Y-12 and NNSA plan to begin developing the LEU solution disposition methodology with the Indonesian facility using small-scale batch-wise methods within existing hot cells, involving straightforward precipitation, ion exchange, decantation, and calcination methods. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Functional Promoter Variant rs2868371 of HSPB1 Is Associated With Risk of Radiation Pneumonitis After Chemoradiation for Non-Small Cell Lung Cancer

Purpose: To date, no biomarkers have been found to predict, before treatment, which patients will develop radiation pneumonitis (RP), a potentially fatal toxicity, after chemoradiation for lung cancer. We investigated potential associations between single nucleotide polymorphisms (SNPs) in HSPB1 and risk of RP after chemoradiation for non-small cell lung cancer (NSCLC). Methods and Materials: Subjects were patients with NSCLC treated with chemoradiation at 1 institution. The training data set comprised 146 patients treated from 1999 to July 2004; the validation data set was 125 patients treated from August 2004 to March 2010. We genotyped 2 functional SNPs of HSPB1 (rs2868370 and rs2868371) from all patients. We used Kaplan-Meier analysis to assess the risk of grade ≥2 or ≥3 RP in both data sets and a parametric log-logistic survival model to evaluate the association of HSPB1 genotypes with that risk. Results: Grade ≥3 RP was experienced by 13% of those with CG/GG and 29% of those with CC genotype of HSPB1 rs2868371 in the training data set (P=.028); corresponding rates in the validation data set were 2% CG/GG and 14% CC (P=.02). Univariate and multivariate analysis confirmed the association of CC of HSPB1 rs2868371 with higher risk of grade ≥3 RP than CG/GG after adjustment for sex, age, performance status, and lung mean dose. This association was validated both in the validation data set and with Harrell's C statistic. Conclusions: The CC genotype of HSPB1 rs2868371 was associated with severe RP after chemoradiation for NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating new production in the equatorial Pacific Ocean at 150 deg W

A major goal of the WEC88 cruise of the R/V Wecoma to the equatorial Pacific (made in February-March 1988) was to establish rates of new production along a meridional section at 150 deg W and to compare these measured rates with the relatively high values for the equatorial Pacific that had been reported previously using indirect methods and models. Production values were obtained from the traditional approach using N-15 labeled nitrate uptake, and by using C-14 fixation values multiplied by f (proportion of new production) from various sources: from N-15 data, from a C-14 fixation-versus-f relationship, or from a nitrate-versus-f relationship. The ratios of directly measured nitrate and carbon uptake and the ratios of nitrate to nitrate plus ammonium uptake, i.e., values of f, agree well; values of f calculated from carbon uptake or from nitrate concentration are overestimates for the equatorial upwelling region. Carbon-to-nitrogen uptake ratios measured with C-14 and N-15, respectively, approximate the Redfield molar ratio, 6.6 C:N. The overall mean value of f (0.17) helps confirm the view that the low primary production in the enriched eastern equatorial Pacific is due to failure of the nitrate-uptake system.

Dugdale, Richard C.↗

Parachute Compartment Drop Test Vehicle for Testing the Crew Exploration Vehicle's Parachute Assembly System

Though getting astronauts safely into orbit and beyond has long been one of NASA?s chief goals, their safe return has always been equally as important. The Crew Exploration Vehicle?s (CEV) Parachute Assembly System (CPAS) is designed to safely return astronauts to Earth on the next-generation manned spacecraft Orion. As one means for validating this system?s requirements and testing its functionality, a test article known as the Parachute Compartment Drop Test Vehicle (PC-DTV) will carry a fully-loaded yet truncated CPAS Parachute Compartment (PC) in a series of drop tests. Two aerodynamic profiles for the PC-DTV currently exist, though both share the same interior structure, and both have an Orion-representative weight of 20,800 lbf. Two extraction methods have been developed as well. The first (Cradle Monorail System 2 - CMS2) uses a sliding rail technique to release the PC-DTV midair, and the second (Modified DTV Sled; MDS) features a much less constrained separation method though slightly more complex. The decision as to which aerodynamic profile and extraction method to use is still not finalized. Additional CFD and stress analysis must be undertaken in order to determine the more desirable options, though at present the "boat tail" profile and the CMS2 extraction method seem to be the favored options in their respective categories. Fabrication of the PC-DTV and the selected extraction sled is set to begin in early October 2010 with an anticipated first drop test in mid-March 2011.

Lubey, Daniel P.↗

FORTRAN Versions of Reformulated HFGMC Codes

Several FORTRAN codes have been written to implement the reformulated version of the high-fidelity generalized method of cells (HFGMC). Various aspects of the HFGMC and its predecessors were described in several prior NASA Tech Briefs articles, the most recent being HFGMC Enhancement of MAC/GMC (LEW-17818-1), NASA Tech Briefs, Vol. 30, No. 3 (March 2006), page 34. The HFGMC is a mathematical model of micromechanics for simulating stress and strain responses of fiber/matrix and other composite materials. The HFGMC overcomes a major limitation of a prior version of the GMC by accounting for coupling of shear and normal stresses and thereby affords greater accuracy, albeit at a large computational cost. In the reformulation of the HFGMC, the issue of computational efficiency was addressed: as a result, codes that implement the reformulated HFGMC complete their calculations about 10 times as fast as do those that implement the HFGMC. The present FORTRAN implementations of the reformulated HFGMC were written to satisfy a need for compatibility with other FORTRAN programs used to analyze structures and composite materials. The FORTRAN implementations also afford capabilities, beyond those of the basic HFGMC, for modeling inelasticity, fiber/matrix debonding, and coupled thermal, mechanical, piezo, and electromagnetic effects.

Arnold, Steven M.↗

The OSIRIS-Rex Asteroid Sample Return: Mission Operations Design

The OSIRIS-REx mission employs a methodical, phased approach to ensure success in meeting the missions science requirements. OSIRIS-REx launches in September 2016, with a backup launch period occurring one year later. Sampling occurs in 2019. The departure burn from Bennu occurs in March 2021. On September 24, 2023, the SRC lands at the Utah Test and Training Range (UTTR). Stardust heritage procedures are followed to transport the SRC to Johnson Space Center, where the samples are removed and delivered to the OSIRIS-REx curation facility. After a six-month preliminary examination period the mission will produce a catalog of the returned sample, allowing the worldwide community to request samples for detailed analysis.Traveling and returning a sample from an Asteroid that has not been explored before requires unique operations consideration. The Design Reference Mission (DRM) ties together space craft, instrument and operations scenarios. The project implemented lessons learned from other small body missions: APLNEAR, JPLDAWN and ESARosetta. The key lesson learned was expected the unexpected and implement planning tools early in the lifecycle. In preparation to PDR, the project changed the asteroid arrival date, to arrive one year earlier and provided additional time margin. STK is used for Mission Design and STKScheduler for instrument coverage analysis.

Challenges in Evaluating Relationships Between Quantitative Data (Carbon Dioxide) and Qualitative Data (Self-Reported Visual Changes)

Understanding the nuances in clinical data is critical in developing a successful data analysis plan. Carbon dioxide (CO2) data are collected on board the International Space Station (ISS) in a continuous stream. Clinical data on ISS are primarily collected via conversations between individual crewmembers and NASA Flight Surgeons during weekly Private Medical Conferences (PMC). Law, et.al, 20141 demonstrated a statistically significant association between weekly average CO2 levels on ISS and self-reported headaches over the reporting period from March 14, 2001 to May 31, 2012. The purpose of this analysis is to describe the evaluation of a possible association between visual changes and CO2 levels on ISS and to discuss challenges in developing an appropriate analysis plan. METHODS & PRELIMINARY RESULTS: A first analysis was conducted following the same study design as the published work on CO2 and self-reported headaches1; substituting self-reported changes in visual acuity in place of self-reported headaches. The analysis demonstrated no statistically significant association between visual impairment characterized by vision symptoms self-reported during PMCs and ISS average CO2 levels over ISS missions. Closer review of the PMC records showed that vision outcomes are not well-documented in terms of clinical severity, timing of onset, or timing of resolution, perhaps due to the incipient nature of vision changes. Vision has been monitored in ISS crewmembers, pre- and post-flight, using standard optometry evaluations. In-flight visual assessments were limited early in the ISS program, primarily consisting of self-perceived changes reported by crewmembers. Recently, on-orbit capabilities have greatly improved. Vision data ranges from self-reported post-flight changes in visual acuity, pre- to postflight changes identified during fundoscopic examination, and in-flight progression measured by advanced on-orbit clinical imaging capabilities at predetermined testing intervals. In contrast, CO2 data are recorded in a continuous stream over time; however, for the initial analysis this data was categorized into weekly averages.

Mendez, C. M.↗

The Kepler End-to-End Data Pipeline: From Photons to Far Away Worlds

Launched by NASA on 6 March 2009, the Kepler Mission has been observing more than 100,000 targets in a single patch of sky between the constellations Cygnus and Lyra almost continuously for the last two years looking for planetary systems using the transit method. As of October 2011, the Kepler spacecraft has collected and returned to Earth just over 290 GB of data, identifying 1235 planet candidates with 25 of these candidates confirmed as planets via ground observation. Extracting the telltale signature of a planetary system from stellar photometry where valid signal transients can be small as a 40 ppm is a difficult and exacting task. The end-to end processing of determining planetary candidates from noisy, raw photometric measurements is discussed.

Cygnus constallation↗

Bioindicator “fingerprints” of methane-emitting thermokarst features in Alaskan soils

Permafrost thaw increases the bioavailability of ancient organic matter, facilitating microbial metabolism of volatile organic compounds (VOCs), carbon dioxide, and methane (CH 4 ). The formation of thermokarst (thaw) lakes in icy, organic-rich Yedoma permafrost leads to high CH 4 emissions, and subsurface microbes that have the potential to be biogeochemical drivers of organic carbon turnover in these systems. However, to better characterize and quantify rates of permafrost changes, methods that further clarify the relationship between subsurface biogeochemical processes and microbial dynamics are needed. In this study, we investigated four sites (two well-drained thermokarst mounds, a drained thermokarst lake, and the terrestrial margin of a recently formed thermokarst lake) to determine whether biogenic VOCs (1) can be effectively collected during winter, and (2) whether winter sampling provides more biologically significant VOCs correlated with subsurface microbial metabolic potential. During the cold season (March 2023), we drilled boreholes at the four sites and collected cores to simultaneously characterize microbial populations and captured VOCs. VOC analysis of these sites revealed “fingerprints” that were distinct and unique to each site. Total VOCs from the boreholes included > 400 unique VOC features, including > 40 potentially biogenic VOCs related to microbial metabolism. Subsurface microbial community composition was distinct across sites; for example, methanogenic archaea were far more abundant at the thermokarst site characterized by high annual CH 4 emissions. The results obtained from this method strongly suggest that ∼10% of VOCs are potentially biogenic, and that biogenic VOCs can be mapped to subsurface microbial metabolisms. By better revealing the relationship between subsurface biogeochemical processes and microbial dynamics, this work advances our ability to monitor and predict subsurface carbon turnover in Arctic soils.

anaerobic degradation↗

The 65 Elevated Risk Container Status Relative Humidity Measurements RFID RH/T Sensors in Containers [Slides]

In March of 2023, a memo was issued, drafted by the Container Management, Safety, and Engineering Team, identifying 65 elevated risk legacy containers for priority disposition at TA-55. These 65 were identified separately from the “typical” prioritization decision-making method used at TA-55 to disposition legacy items. This new technique gave important feedback and revealed improvement opportunities for the selection process of legacy containers for disposition. The DOE complex and TA-55 have a long history of nuclear operations and therefore the disposition of these legacy materials is vital.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient scattering from two-dimensional dielectric cylinders of arbitrary shape

In this work, the problem of transient scattering by arbitrary shaped two-dimensional dielectric cylinders is solved using the marching-on-in-time (MOT) technique. The dielectric problem is approached via the surface equivalence principle. A pair of coupled integral equations are derived by enforcing the continuity of the electric and magnetic fields which are solved by using the method of moments. Numerical results are presented for two cross sections, viz. a circle and a square, and compared with inverse discrete Fourier transform (IDFT) techniques. In each case, good agreement is obtained with the IDFT solution.

Vechinski, Douglas A.↗

JANNAF 30th Propellant Development and Characterization Subcommittee Meeting

This volume, the first of three volumes, is a compilation of 22 unclassified/unlimited technical papers presented at the Joint Army-Navy-NASA-Air Force (JANNAF) 30th Propellant Development & Characterization Subcommittee Meeting, held on 18-21 March 2002 at the Sheraton Colorado Springs Hotel, Colorado Springs, Colorado. The papers presented herein reflect work performed in the areas of green energetic materials (GEM) development; liquid and gel propellant development; propellant surveillance and aging; and propellant chemistry test methods.

Moore, T. L.↗