Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MATRICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Rotational symmetry relation for efficient response function generation in the coarse mesh transport method COMET

The coarse mesh transport code COMET is a continuous energy hybrid stochastic-deterministic neutronics solver with high fidelity and formidable computation speed in solving reactor core problems. Its method is based on the incident flux expansion theory. In this work, we take advantage of the local geometric symmetry in many reactor cores lattices (e.g., fuel lattices and reflector blocks) to develop relations among the flux response expansion coefficients for symmetric surfaces to further improve the computational efficiency of the COMET response function generation tool (method). This is done by a rigorous derivation of the transformation matrices for the angular and spatial expansion moments resulting from a rotation of a coarse mesh by an arbitrary angle. The relations for the response coefficients for the symmetric surfaces can be then written as the Kronecker product of those transformation matrices. The method is implemented into COMET and tested on two advanced high temperature reactor (AHTR) full-length single assembly benchmark problems. The COMET results using the response function library based on the symmetry relations were compared to those using the library directly generated by continuous energy Monte Carlo for all surfaces. It was found that the eigenvalues and stripe-wise fission densities using the two libraries are in statistical agreement as expected. This indicates that the new method maintains the high fidelity of the original COMET method while improving the computational efficiency in the response function generation by 270% to 400%, depending on the local geometric symmetry. This method also reduces the size of the response function library by the same magnitude (270% to 400%). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Efficient ptychographic phase retrieval via a matrix-free Levenberg-Marquardt algorithm

The phase retrieval problem, where one aims to recover a complex-valued image from far-field intensity measurements, is a classic problem encountered in a range of imaging applications. Modern phase retrieval approaches usually rely on gradient descent methods in a nonlinear minimization framework. Calculating closed-form gradients for use in these methods is tedious work, and formulating second order derivatives is even more laborious. Additionally, second order techniques often require the storage and inversion of large matrices of partial derivatives, with memory requirements that can be prohibitive for data-rich imaging modalities. We use a reverse-mode automatic differentiation (AD) framework to implement an efficient matrix-free version of the Levenberg-Marquardt (LM) algorithm, a longstanding method that finds popular use in nonlinear least-square minimization problems but which has seen little use in phase retrieval. Furthermore, we extend the basic LM algorithm so that it can be applied for more general constrained optimization problems (including phase retrieval problems) beyond just the least-square applications. Since we use AD, we only need to specify the physics-based forward model for a specific imaging application; the first and second-order derivative terms are calculated automatically through matrix-vector products, without explicitly forming the large Jacobian or Gauss-Newton matrices typically required for the LM method. We demonstrate that this algorithm can be used to solve both the unconstrained ptychographic object retrieval problem and the constrained “blind” ptychographic object and probe retrieval problems, under the popular Gaussian noise model as well as the Poisson noise model. We compare this algorithm to state-of-the-art first order ptychographic reconstruction methods to demonstrate empirically that this method outperforms best-in-class first-order methods: it provides excellent convergence guarantees with (in many cases) a superlinear rate of convergence, all with a computational cost comparable to, or lower than, the tested first-order algorithms.

36 MATERIALS SCIENCE↗

Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method’s LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method’s main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Daily water stable isotopes, transpiration, and matrix potential data for an aspen and engelmann stand in the East River Watershed (version 2)

We provide daily stable isotope (2H & 18O) ratios in soil water and xylem (plant stem) water, as well as the sap flow (transpiration) and the soil's matric potential at a forested site near Gothic, Colorado, in the East River catchment. We measured the stable isotopic composition of the transpiration and the daily transpiration flux sum of three aspen and three engelmann spruce. In both forest stands, we installed a soil profile and measured the soil matric potential at 15, 30, and 60 cm depth as well as the stable isotopes of soil pore water at 5, 10, 30, 60, and 90 cm depths. All isotope measurements were done in situ via vapor probes connected to a cavity ring down spectrometer (Picarro L1240i).We further report the daily meteorological data observed at billy barr near our study site. We also provide for each tree the relative share of root water uptake derived from the isotope measurements via a Bayesian mixing model (MixSIAR).The daily data is provided as a time series in "Iso_MP_Sap_DataDaily_ESSDiveUpload.csv" and the units are provided in "dd.csv"; the location of the instrumented trees and soil profiles are given as latitude and longitude coordinates saved as CSV and KMZ files; and a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata.The data was gathered to investigate the short-term changes of the water sources (i.e., variation of root water uptake from different soil depths) of the studied subalpine trees.Update 07/16/2025: The relative and absolute plant water uptake depths were grouped to ensure that the MixSIAR model was applied with endmembers that differed in their d2H value by at least 3 permill and at least 1 permill for d18O. Whenever the difference between observed d2H values for two or more probes at neighboring depths was less than 3 permill, we used the average value for the source water endmember. For days at which probes that were not next to each other measurements did not differ at least 3 permill, the average of all probes between these two depths was used as the water source endmember representing the depth range between these two probes.

54 ENVIRONMENTAL SCIENCES↗

Contrast Matching Biopolymers: A SANS-Based Approach to Structural Characterization of Chitosan

Immobilizing enzymes in polysaccharide-based matrices has been shown to improve both their stability and their catalytic efficiency. Among available materials, chitosan was selected for its abundance, biocompatibility, and versatility in a range of applications. While the broader aim of this work is to study chitosan as a matrix for immobilizing carbonic anhydrase (CA) for CO₂ capture, this study focused on determining the contrast match point (CMP) of hydrogenated and deuterated chitosan in D₂O:H₂O mixtures to enable future structural investigations using small-angle neutron scattering (SANS). Previous work successfully synthesized deuterated chitosan from Rhizopus oryzae mycelia and assessed the degree of deuteration using Fourier-transform infrared spectroscopy (FTIR) and nuclear magnetic resonance (NMR). Building on this foundation, the current study determined the CMPs of both H-chitosan and D-chitosan by performing SANS measurements across a range of D₂O:H₂O solvent contrasts. The extracted CMPs for both forms correlated well with their respective calculated scattering length densities (SLDs), validating the experimental approach. These results establish a critical reference for selective contrast matching in future SANS studies of carbonic anhydrase immobilized in chitosan matrices, enabling detailed structural analysis of enzyme–matrix interactions.

Kosgallana, Chathurika J [ORNL] (ORCID:00000002851↗

Electron beam treatment for the removal of 1,4-dioxane in water and wastewater

Electron beam (e-beam) treatment uses accelerated electrons to form oxidizing and reducing radicals when applied to water without the use of external chemicals. In this study, electron beam treatment was used to degrade 1,4-dioxane in several water matrices. Removal improved in the progressively cleaner water matrices and removals as high as 94% to 99% were observed at a dose of 2.3 kGy in secondary effluent. 1,4-dioxane removal was confirmed to be primarily through hydroxyl radical oxidation. The calculated electrical energy per order was found to be 0.53, 0.26, and 0.08 kWh/m 3 /order for secondary effluent (Avg. total organic carbon (TOC) 9.25 mg/L), granular activated carbon effluent (TOC 3.46 mg/L), and ultrapure water, respectively, with a 70% generation and transfer efficiency applied.

1,4-dioxane↗

Tailoring Charge Transport and Magnetism in Complex Half-Heusler/Full-Heusler Nanocomposites (Final Report)

This project exploits (1) the facile co-crystallization of the half-Heusler (HH) and full-Heusler (FH) structures, (2) the high coherency and stability of the HH/FH interfaces, and (3) the solid-state inter-conversion between HH and FH structures through local atomic diffusion, to investigate, for selected compositions of the HH and FH phases, the effect of size, dimensionality, dispersion and volume fraction of FH nanostructures on the electronic, phonon and magnetic behavior of the resulting HH/FH nanocomposites. Our goal is to identify and control key material and growth parameters governing phase formation, microstructural evolution, and to understand the mechanism by which these changes of the internal structure modify the material’s performance. To elucidate the mechanism by which the FH nanostructures regulate electronic charge transport and induce ferromagnetism within non-magnetic and magnetic semiconducting HH matrices, suitable series of HH/0D-FH and HH/2D-FH nanocomposites will be fabricated using synthesis conditions suggested by theoretical calculations of the formation energy and stability of various FH phases (varying M) in HH matrices with known chemical composition. The structure of the HH/FH interfaces (size, chemical composition, volume fraction and dispersion) will be investigated along with the evaluation of the electronic (carrier density, mobility, thermopower, electrical conductivity, effective mass), thermal and magnetic (susceptibility, magnetization etc.) properties of the resulting HH/FH nanocomposites.

36 MATERIALS SCIENCE↗

Functional Nanomaterials with Tunable Plasmonic and Emittive Properties (Final Project Report)

The goal of the project is on understanding the principles of non-covalent assembling of tunable functional materials with various nanocrystals in order to control light-matter interactions by changing localized interfacial refractive properties, coupling parameters, or the ionic environment of surrounding media. We explore novel soft functional matrices with controlled physical properties via the application of light, mechanical stresses, ionic environment, and electrical potential. These functional matrices is used in conjunction with novel anisotropic inorganic nanostructures such as noble metal/metal alloy anisotropic nanostructures with complex optical properties (multiple LSPR modes) and quantum dots with light-emissive or absorbing properties in a broad spectral range from the UV to the NIR for efficient solar energy absorption and light conversion.

36 MATERIALS SCIENCE↗

Crystalline Silicotitanate Batch Contact Testing with Ba, Ca, Pb, and Sr

Washington River Protection Solutions is working to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. This goal incorporates the design of a Tank Side Cesium Removal system, which filters tank waste supernate to remove suspended solids and then removes Cs by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The 137 Cs-depleted product is intended to be sent to the WTP for vitrification. Processing of actual tank waste supernate showed effectively complete uptake of Sr and Ba by CST and significant uptake of Ca. Further, Campbell et al. (2019) analyzed CST post-column testing and found significant (>1E-2 mmoles/g) uptake of Ca and Pb along with some Ba, Cd, Fe, Sr, and U. This led to concern that selected metals, particularly the +2 cations, Ca, Sr, Ba, and Pb may be consuming Cs exchange sites and possibly reducing CST capacity for Cs. Exchange of +2 cations was assumed to be associated with the M(OH) + species for the metal (M) ion in the caustic solution. A series of batch contact testing was conducted to evaluate the exchange behavior of Ba, Ca, Pb, and Sr onto CST. The Cs exchange behavior was also tested as a benchmark for direct comparisons. The CST was provided in the sodium form by Honeywell UOP, as IONSIV TM R9140-B, Lot 2002009604, 18 x 50 mesh. A <30-mesh aliquot was collected to match the sieve fraction expected for use in upcoming small column test configurations. Kinetic exchange rate and isotherms were measured at metal concentrations benchmarked from the AP-107 tank waste feed composition and as limited by the metal solubility in the alkaline solution. Two simplified matrices were tested: 1) 1.0 M NaOH/4.6 M NaNO 3 and 2) 0.1 M NaOH/5.5 M NaNO 3 ; these matrices represented the expected 5.6 M Na concentration of process feed and served to address the hydroxide concentration effect on exchange behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LAW Simulant Recipes for Evaluation of Real-Time, In-Line Monitoring Instruments

Statistically designed recipes were generated for evaluation of in-line instrumentation for the Real-Time In-Line Monitoring (RTIM) program in support of the Hanford Direct-Feed Low Activity Waste (DFLAW) program. The composition matrices were prepared based on Low Activity Waste (LAW) feed vector, melter feed, and Effluent Management Facility (EMF) feed information provided by the flowsheet integration modelling for the DFLAW portion of the Waste Treatment Plant (WTP) mission. These composition matrices were converted to recipes for the LAW feed using the approaches for LAW simulant recipes developed by Savannah River National Laboratory (SRNL). Recipes for the glass forming chemicals (GFCs) were developed based on expected mineral forms to be used to for each element to be added to the recipe.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Randomized Cholesky Preconditioning for Graph Partitioning Applications

Graph partitioning has emerged as an area of interest due to its use in various applications in computational research. One way to partition a graph is to solve for the eigenvectors of the corresponding graph Laplacian matrix. This project focuses on the eigensolver LOBPCG and the evaluation of a new preconditioner: Randomized Cholesky Factorization (rchol). This proconditioner was tested for its speed and accuracy against other well-known preconditioners for the method. After experiments were run on several known test matrices, rchol appears to be a better preconditioner for structured matrices. This research was sponsored by National Nuclear Security Administration Minority Serving Institutions Internship Program (NNSA-MSIIP) and completed at host facility Sandia National Laboratories. As such, after discussion of the research project itself, this report contains a brief reflection on experience gained as a result of participating in the NNSA-MSIIP.

97 MATHEMATICS AND COMPUTING↗

International Benchmarking: A Global Perspective of Workplace Drug and Alcohol Testing

Workplace drug and alcohol testing has been widely implemented in diverse industries and is designed to detect the use of and deter the influence of legal and illegal substances that would impair the ability to perform work that has significant security and safety implications. Across the globe, patterns of drug and alcohol use and abuse and the regulations controlling drug and alcohol use vary by location (e.g., regions, countries, etc.). The prevalence of workplace drug and alcohol testing and protection of individuals’ rights in the workplace similarly tend to exhibit contextual differences. With the advancements in drug-testing technologies and the recent issuance of guidance for additional testing matrices (e.g., oral fluid, hair, etc.) by the U.S. Department of Health and Human Services, gaining a global perspective on the current state of drug and alcohol testing practices and regulations is important for leveraging such advancements to improve the effectiveness of drug and alcohol testing. The U.S. Nuclear Regulatory Commission (NRC) tasked the Pacific Northwest National Laboratory (PNNL) fitness for duty (FFD) team to conduct a benchmarking analysis of international drug and alcohol testing regulations and programs to identify similarities and differences in workplace testing programs and the basis for any differences. The benchmarking study focuses on a policy analysis and benchmarking metrics comparison among different countries and regions. The policy analysis includes the following three types of relevant international and national policies relevant to drug and alcohol testing in the nuclear industry: 1. National drug and alcohol policy 2. Workplace drug and alcohol testing 3. FFD regulations for Nuclear Power Plants The international drug and alcohol benchmarking metrics focusses on the use of blood, breath, urine, hair, and oral fluid in testing; drug and drug metabolite cutoff values; point-of-collection testing devices; roadside testing methodologies; innovations in drug testing; and the extent of availability of such data. Gaining an understanding of workplace drug and alcohol testing in other countries as well as information about new testing methods, matrices, tools, and technologies that other countries have adopted provides NRC with international comparative information regarding the technical basis for such programs and methods as it relates to the protection of worker and public health and safety.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physics-informed Estimation of the Covariance Matrix for Various Neutron Spectra

A method for estimating covariance matrices which capture the uncertainties in calculated reactor spectra has been developed. This method is based on perturbing the parameters of a physics-based analytic model fitted to a calculated spectrum. The covariance of the perturbed analytic spectra imposes energy-dependent correlations due to the physics of the neutron processes in the reactor, i.e., a fission component, a 1/E down-scatting component, and a thermal Maxwellian component. An analytic model is developed which is shown to produce good fits to several reactor environments. The covariance matrices produced via this method are then used as the prior spectrum in STAYSL least squares spectrum adjustment where it is combined with integral metrics, such as activation measurements, to produce a high-fidelity neutron spectrum characterization. It was concluded that the methodology showed agreeable results for the ACRR free-field spectrum adjustment in STAYSL resulting in a 𝜒 2 value of 2.21 (per degree of freedom), but further work is needed to describe scattering and interface regions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY24 Task 5: Leachate Disposition

Directly feeding sludge solids to the high-level waste (HLW) Waste Treatment Plant represents an alternative flowsheet seeking to initiate sludge processing as soon as possible. Key processing functions previously captured during baseline pretreatment operations include leaching and washing prior to solids concentration. These operations should be considered in the potential direct feed flowsheets to maximize waste feed loading, minimize HLW volume, and mitigate corrosion challenges associated with vitrification of high phosphate and fluoride concentrations. Additionally, single-shell tank (SST) retrievals and waste transfers to double-shell tanks (DSTs) in a direct feed flowsheet would likely also benefit from some level of leaching, washing, and solids concentration in order to reduce DST space and mission duration. These operations could occur in a new facility or potentially in available DSTs. If washing and leaching are utilized, an effective disposition pathway for the wash water and leachate solutions are needed. Three target species that benefit significantly from leaching and washing are phosphate, fluoride and aluminum. Phosphate (PO 4 3- ) and fluoride (F - ) can contribute substantially to the amount of carrier fluid needed for dissolution, and the resulting volume of liquid generated. Disposition of this retrieval solution should be evaluated in order to prevent crystallization of these anions throughout system processing. Since there is a high probability that any retrieval solutions will be at or near their PO 4 3- and F - solubility limits, evaporation or blending with a high Na supernate (>3.5 M) is not recommended for the wash water streams without a method to remove precipitants prior to solution disposal. Additionally, aluminum present in the southeast quadrant of the Hanford site represents roughly 60% of the waste solids in the initial processing tanks. These aluminum solids are in the form of gibbsite (Al(OH) 3 ) and can pose significant challenges for processing due to the fast-settling times and high solids loading associated with these materials. Easily remediated by caustic addition to the solids, these wash solutions could be processed through crystalline silicotitanate (CST) ion exchange columns to prepare the supernate solutions for disposition. The current target for feed conditions to the Low Activity Waste (LAW) melter are waste streams that contain nominally 5-6 M Na. Fractions within the tanks contain upwards of 0.2 M phosphate and fluoride in solution at 3.5 M Na. Concentrating these solutions above 5 M Na would result in an exceedance of the solubility limits, and potential for uncontrolled precipitation of the phosphate and fluoride crystal material. The resulting crystalline salt material is typically sodium fluoride phosphate, also referred to as natrophosphate (Na 7 FPO 4 ·19H 2 O). Salt phases are of importance in tank waste due to their chemical reactivity, which can result in precipitation, dissolution, or transformation, impacting any downstream processes (Bolling et al. 2020, Russell, Snow, and Peterson 2010). Salt generation and precipitation could pose challenges by causing system plugging and melter corrosion if left in the supernate stream, or limit sodium molarity of the supernate that would be accepted without incident in waste operations. To understand the impact of this salt generation, the crystallization of natrophosphate in multiple simulant feed matrices was studied to understand the implications of various tank waste supernate chemistries. Three matrices were examined: high PO 4 3- /low F - , low PO 4 3- /high F - , and an average matrix. Subsequent testing was performed with the average matrix with the inclusion of CsNO 3 , and a final run with the average matrix including CsNO 3 and a 137 Cs spike for tracer purposes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Baltimore Turfgrass Field Experiment Campaign Report

The Baltimore Turfgrass Field Experiment (BTFE) consisted of an observation eddy covariance flux station, measuring CO 2 , H 2 O, and turbulent energy fluxes between the turfgrass field and the atmosphere. The tower was sited before the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s arrival, but for the purposes of this report, we can say that the campaign lasted as long as the Coast-Urban-Rural Atmospheric Gradient Experiment (CoURAGE) campaign, 12 months, 12/2024 through 11/2025. As stated, the flux tower was part of the COURAGE campaign on the M1 site. We set out to measure turfgrass because it is a ubiquitous part of the urban environment—in fact, it is the dominant vegetation land cover type in Baltimore and most cities. It contributes small but significantly to greenhouse gas balances as well as the energy balance in the urban environment. We also installed a soil temperature and matric potential profiling system as part of this experiment. Additionally, AmeriFlux asked us to participate in their soil matric potential soil moisture mapping experiment. We collected 12 soil samples to be analyzed by a team in Bloomington, Indiana: results are pending.

54 ENVIRONMENTAL SCIENCES↗

Performance Improvements of the Griffin Solvers in FY24

The Griffin code is a MOOSE-based reactor physics application jointly developed by Idaho National Laboratory and Argonne National Laboratory under the Department of Energy Office of Nuclear Energy Nuclear Energy Advanced Modeling and Simulation Program. This fiscal year, we have made significant efforts to improve the performance of transport solver options and cross-section generation for the efficient use of Griffin in advanced reactor applications. For the HFEM-PN solver, the residual evaluations of HFEM kernels were optimized by utilizing the pre- computed averaged cross sections for individual elements. Numerical integration involving the evaluation of basis functions at quadrature points was bypassed by facilitating precomputed element mass matrices for response matrices. Red-black iterations were improved by introducing a new generalized minimum residual based solver. The memory usage of response matrix storage was significantly reduced by applying basis function rotations on interfaces and calculating volumetric odd-parity moments on the fly. Additionally, the adjoint flux and transient calculation capabilities of the HFEM-PN solver were successfully implemented and verified using the TWIGL benchmark problem. For the DFEM-SN solver, memory footprint and computation time were significantly reduced by not treating angular flux vectors as the MOOSE nonlinear system vectors. Specifically for IQS, scalar adjoint weighting was introduced to further eliminate angular adjoint flux storage in the MOOSE auxiliary system. It was demonstrated through the three-dimensional Advanced Burner Test Reactor core problem that the memory usage for transient calculations with the IQS method was reduced by over 7.5× compared to before the optimizations. For the self-shielding application programming interface, a new double-heterogeneity treatment method, named the Bell Function-Based Analytic Two-Region Slowing Down Method, was developed to efficiently flux-volume homogenize TRISO particles with the matrix. Additionally, optimizations were made to hyper- fine group (HFG) slowing down calculations by pretabulating collision probability coefficients and grouping isotopes, significantly reducing the computational time for calculating scattering sources per HFG. Lastly, the pin power reconstruction module was extended to account for temporal behavior in a microreactor analysis problem, specifically for a control drum transient. Verification tests for each of these improvements demonstrated significant performance enhancements and memory reduction.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗