Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Keto-acids in Carbonaceous Meteorites

The Murchison and Murray meteorites are the best-characterized carbonaceous meteorites with respect to organic chemistry and are generally used as references for organic compounds in extraterrestrial material. Among the classes of organic compounds found in these meteorites are amino acids, carboxylic acids, hydroxy acids, purines, and pyrimidines. Such compounds, important in contemporary biochemistry, are thought to have been delivered to the early Earth in asteroids and comets and may have played a role in early life and/or the origin of life. Absent among (today's) critically important biological compounds reported in carbonaceous meteorites are keto acids, i.e., pyruvic acid, acetoacetic acid, and higher homologs. These compounds are key intermediates in such critical processes as glycolysis and the citric acid cycle. In this study several individual meteoritic keto acids were identified by gas chromatography-mass spectrometry (GC-MS) (see figure below). All compounds were identified as their trimethylsilyl (TMS), isopropyl ester (ISP), and tert-butyldimethylsilyl (tBDMS) derivatives. In general, the compounds follow the abiotic synthesis pattern of other known meteorite classes of organic compounds [1,2]: a general decrease in abundance with increasing carbon number within a class of compounds and many, if not all, possible isomers present at a given carbon number. The majority of the shown compounds was positively identified by comparison of their mass spectra to commercially available standards or synthesized standards.

Cooper, G.↗

Cassini-Huygens Probe Gas Chromatograph Mass Spectrometer (GCMS) Experiment: First Results

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14, 2005. The GCMS was part of the instrument complement on the probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyzer (ACP) experiment by serving as detector for the pyrolization products. The GCMS collected data from an altitude of 146 km to ground impact for a time interval of 2hours and 37minutes. The Probe and the GCMS survived the ground impact and collected data for 1hour and 9 minutes on the surface in the near surface environment until signal loss by the orbiter. The major constituents of the lower atmosphere were found to be N2 and CH4. The methane-mixing ratio was found to increase below the turbopause, about 35 km altitude, monotonically toward the surface to levels near saturation. After surface impact a steep increase of the mixing ratio was observed suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. Other constituents were found to be in very low concentrations, below ppm levels. The presence of Argon 40 was confirmed. The results for the other noble gases are still being evaluated. Other hydrocarbons and nitriles were also observed and quantitative evaluation is in progress. Preliminary ratios for the major carbon and nitrogen isotopes were computed from methane and molecular nitrogen measurements. The instrument collected 5634 mass spectra during descent and 2692 spectra on the ground over a range of m/z from 2 to 141. Eight gas chromatograph samples were taken during the descent and two on the ground.

Niemann, H.↗

The Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe: First Results

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14, 2005. The GCMS was part of the instrument complement on the Probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyzer (ACP) experiment by serving as detector for the pyrolization products. The GCMS collected data from an altitude of 146 km to ground impact for a time interval of 2 hours and 37 minutes. The Probe and the GCMS survived the ground impact and collected data for 1 hour and 9 minutes on the surface in the near surface environment until signal loss by the orbiter. The instrument collected 5634 mass spectra during descent and 2692 spectra on the ground over a range of m/z from 2 to 141. Eight gas chromatograph samples were taken during the descent and two on the ground. This is a report on work in progress. The major constituents of the lower atmosphere were found to be N2 and CH4. The methane-mixing ratio was found to increase below the turbopause, about 35 km altitude, monotonically toward the surface to levels near saturation. After surface impact a steep increase of the mixing ratio was observed suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. Other constituents were found to be in very low concentrations, below ppm levels. The presence of Argon 40 was confirmed. The results for the other noble gases are still being evaluated. Other hydrocarbons and nitriles were also observed and quantitative evaluation is in progress. Preliminary ratios for the major carbon and nitrogen isotopes were computed from methane and molecular nitrogen measurements.

Niemann, H.↗

LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

Zuwei, Wang↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The GCMS was part of the instrument complement on the Cassini-Huygens Probe to measure in situ the chemical composition of the atmosphere during the probe descent and coupled with the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products to determine the composition of the aerosol particles. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be NP and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3 x 10(exp-5) and of Ar-36 is 2.8 x 10(exp -7). The other primordial noble gases were below mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3 x l0(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane.

Niemann, Hasso B.↗

Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Fast Airborne Aerosol Size and Chemistry Measurements with the High Resolution Aerosol Mass Spectrometer during the MILAGRO Campaign

The concentration, size, and composition of non-refractory submicron aerosol (NR-PM(sub l)) was measured over Mexico City and central Mexico with a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS) onboard the NSF/NCAR C-130 aircraft as part of the MILAGRO field campaign. This was the first aircraft deployment of the HR-ToF-AMS. During the campaign the instrument performed very well, and provided 12 s data. The aerosol mass from the AMS correlates strongly with other aerosol measurements on board the aircraft. Organic aerosol (OA) species dominate the NR-PM(sub l) mass. OA correlates strongly with CO and HCN indicating that pollution (mostly secondary OA, SOA) and biomass burning (BB) are the main OA sources. The OA to CO ratio indicates a typical value for aged air of around 80 microg/cubic m (STP) ppm(exp -1). This is within the range observed in outflow from the Northeastern US, which could be due to a compensating effect between higher BB but lower biogenic VOC emissions during this study. The O/C atomic ratio for OA is calculated from the HR mass spectra and shows a clear increase with photochemical age, as SOA forms rapidly and quickly overwhelms primary urban OA, consistent with Volkamer et al. (2006) and Kleinman et al. (2008). The stability of the OA/CO while O/C increases with photochemical age implies a net loss of carbon from the OA. BB OA is marked by signals at m/z 60 and 73, and also by a signal enhancement at large m/z indicative of larger molecules or more resistance to fragmentation. The main inorganic components show different spatial patterns and size distributions. Sulfate is regional in nature with clear volcanic and petrochemical/power plant sources, while the urban area is not a major regional source for this species. Nitrate is enhanced significantly in the urban area and immediate outflow, and is strongly correlated with CO indicating a strong urban source. The importance of nitrate decreases with distance from the city likely due to evaporation. BB does not appear to be a strong source of nitrate despite its high emissions of nitrogen oxides, presumably due to low ammonia emissions. NR-chloride often correlates with HCN indicating a fire source, although other sources likely contribute as well. This is the first aircraft study of the regional evolution of aerosol chemistry from a tropical megacity.

DeCarlo, P. F.↗

Aromatic Structure in Simulates Titan Aerosol

Observations of Titan by the Cassini Composite Infrared Spectrometer (CIRS) between 560 and 20 per centimeter (approximately 18 to 500 micrometers) have been used to infer the vertical variations of Titan's ice abundances, as well as those of the aerosol from the surface to an altitude of 300 km [1]. The aerosol has a broad emission feature centered approximately at 140 per centimeter (71 micrometers). As seen in Figure 1, this feature cannot be reproduced using currently available optical constants from laboratory-generated Titan aerosol analogs [2]. The far-IR is uniquely qualified for investigating low-energy vibrational motions within the lattice structures of COITIDlex aerosol. The feature observed by CIRS is broad, and does not likely arise from individual molecules, but rather is representative of the skeletal movements of macromolecules. Since Cassini's arrival at Titan, benzene (C6H6) has been detected in the atmosphere at ppm levels as well as ions that may be polycyclic aromatic hydrocarbons (PAHs) [3]. We speculate that the feature may be a blended composite that can be identified with low-energy vibrations of two-dimensional lattice structures of large molecules, such as PAHs or nitrogenated aromatics. Such structures do not dominate the composition of analog materials generated from CH4 and N2 irradiation. We are performing studies forming aerosol analog via UV irradiation of aromatic precursors - specifically C6H6 - to understand how the unique chemical architecture of the products will influence the observable aerosol characteristics. The optical and chemical properties of the aromatic analog will be compared to those formed from CH4/N2 mixtures, with a focus on the as-yet unidentified far-IR absorbance feature. Preliminary results indicate that the photochemically-formed aromatic aerosol has distinct chemical composition, and may incorporate nitrogen either into the ring structure or adjoined chemical groups. These compositional differences are demonstrated in the aerosol mass spectra shown in Figure 2. The aromatic aerosol also demonstrates strong chemical reactivity when exposed to laboratory air, indicating substantial stored chemical potential. Oxidatoin and solubility studies wil be presented and implicatoins for prebiotic chemistry o nTitan will be discussed.

Trainer, Melissa G.↗

Evaluation of Volatile Species in Green Monopropellant Project

NASA is interested in green monopropellants to replace hydrazine in reaction control systems (RCSs). Some current NASA programs require reduced vapor pressure and low toxicity monopropellant (green) and superior performance (specific impulse and density) formulations. Earlier vapor phase studies of a candidate green monopropellant at the NASA White Sands Test Facility (WSTF) showed the presence of a volatile species that warranted further investigation. The purpose of this study was to further characterize the volatile species and to evaluate it. The evaluation was with respect to whether the volatile species was an impurity or how it is formed, and to use that information to examine whether its presence as an impurity can be eliminated during formulation. The evaluation also considered whether formation of the volatile impurity could be prevented while not compromising the propellant. To reduce variables associated with evaluation of the propellant formulation as a whole, a precursor to one of the individual components in the propellant formulation was subjected to a NASA Standard 6001B Flammability, Off-gassing, and Compatibility Requirements and Test Procedures "Determination of Off-gassed Products (Test 7)". Testing took place in the NASA WSTF Molecular Desorption and Analysis Laboratory. One gram of the precursor was placed in a flask within a specimen container. After thermal conditioning for 72 +/- 1 h at 50 +/- 3 deg C (122 +/- 5 deg F), the atmosphere inside the specimen container was analyzed for off-gassed compounds by cryotrap gas chromatography-mass spectrometry (GC-MS) and fixed sample loop GC-flame ionization detection (GC-FID). The specimen container used was glass to minimize potential catalytic surfaces. The identification of compounds was difficult due to the complexity of the vapor phase concentrations and overlapping chromatographic peaks and mass spectra. However, eleven compounds were specifically identified and five compounds or classes of compounds were reported as unidentified. Quantitation of most of the compounds, including unidentified compounds, was as methane. Quantitating compounds or classes of compounds that were detected but for which specific calibration is not established as methane is in accordance with the Test 7 standard protocol. The thermal decomposition temperature of the precursor was significantly higher than the test temperature. Based on thermal decomposition temperature and on an examination of the structure and chemistry of the identified volatile species, the presence of the volatile species appears to be chemically reasonable with respect to the propellant formulation and is at this time attributed to impurities. Further examination of the overall propellant formulation process (including the individual components' synthesis processes) and process quality control (including purity of reagents and possible decomposition reactions) is indicated.

Greene, Benjamin↗

International Space Station (ISS) Environmental Control and Life Support System (ECLSS) Vent Flow Reflection and Detection by Robotic External Leak Locator (RELL)

On-orbit Robotic External Leak Locator (RELL) (i.e., mass spectrometer and ion gauge) measurements on the International Space Station (ISS) are presented to show the detection of recurring Environmental Control and Life Support System (ECLSS) vents at multiple ISS locations and RELL pointing directions. The path of ECLSS effluents to the RELL detectors is not entirely obvious at some locations, but the data indicates that diffuse gas-surface reflection or scattering resulting from plume interaction with vehicle surfaces is responsible. RELL was also able to confirm the ISS ECLSS constituents and distinguish them from the ammonia leak based on the ion mass spectra and known venting times during its operation to locate a leak in the ISS port-side External Active Thermal Control System (EATCS) coolant loop.

Gas/Surface Reflections or Scattering↗

Environmental Design Implications for Deep Space SmallSats

The paper will describe the key technical drivers on the Sylph mission concept to explore a plume at Europa as a secondary free-flyer as a part of the planned Europa Mission. Sylph is a radiation-hardened smallsat concept that would utilize terrain relative navigation to fly at low altitudes through a plume, if found, and relay the mass spectra data back through the flyby spacecraft during its 24-hour mission. The second topic to be discussed will be the mission design constraints of the Near Earth Asterioid (NEA) Scout concept. NEAScout is a 6U cubesat that would utilize an 86 sq. m solar sail as propulsion to execute a flyby with a near-Earth asteroid and help retire Strategic Knowledge Gaps for future human exploration. NEAScout would cruise for 24 months to reach and characterize one Near-Earth asteroid that is representative of Human Exploration targets and telemeter that data directly back to Earth at the end of its roughly 2.5 year mission.

Kahn, Peter↗

Application of Whole Genome Sequencing and MALDI-TOF to the Identifcation of Bacillus Species Isolated from Cleanrooms at NASA Johnson Space Center

Astromaterial cleanrooms at NASA Johnson Space Center are built environments that hold samples, such as lunar rocks, from different space exploration missions. Bacillus sp. are frequently detected in routine microbial monitoring of these facilities. Since this, and related genera, can form endospores that can withstand harsh conditions, they could contaminate astromaterials. This could confound searches for extraterrestrial life. Whole genome sequencing (WGS) is widely used for identifying bacterial strains and tracking their source; however, WGS is expensive and time consuming. Matrix-assisted laser desorption ionization– time of flight mass spectrometry (MALDI-TOF) shows promise as a low-cost, rapid method of identifying strains of bacteria, but few studies have compared this proteomics method to WGS. To evaluate a high throughput method of tracking the source of contamination of this built environment, WGS and MALDI-TOF was conducted on 18 bacterial strains isolated from surfaces in astromaterials cleanrooms. WGS identified 14 Bacillus, 2 Paenibacillus, 1 Solibacillus and 1 Alcaligenes strains. These isolates showed similarity to strains commonly observed in spacecraft assembly cleanrooms at other facilities. Cluster analysis of mass spectra generated by MALDI-TOF grouped strains together that were greater than 94% similar to each other in terms of amino acid sequences of single copy core genes, as assessed by WGS. This suggests that MALDI-TOF and WGS results are consistent with each other and MALDI-TOF can rapidly identify strains of Bacillus sp. isolated from cleanroom environments with a resolution comparable to WGS. Based on phylogenomic analysis, these results also suggest the presence of a cosmopolitan class of Bacillus sp. that are more likely to be found in cleanrooms and similar built environments than in natural systems.

Farnaz Mazhari↗

Understanding the Chemistry of PAHs in H2O Ice

Polycyclic aromatic hydrocarbons (PAHs) can be incorporated into H O ice grains and mantles found in dense molecular clouds, comets, interplanetary dust particles (IDPs), and many Solar System objects. However, laboratory infrared (IR) spectroscopic studies of PAHs in ices is still a relatively young field. Early research efforts have shown the rich chemistry of PAHs in H O to be dependent on PAH concentration, with the concentration impacting everything from IR band shifts to the photoproducts produced [1-6]. Similarly, research suggests that a potential top-down synthesis route for complex organic molecules or COMs found within solar systems is possible from PAHs in water ice [7]. In order to fully exploit the observations from the James Webb Space Telescope (JWST) more IR studies of PAHs in H O ice under relevant astrophysical conditions and planetary systems are needed. The NASA ICEE (Institute for Carbon Evolution Experiments), formerly the NASA Ames PAH IR Laboratory, has been at the forefront of this field. Starting in 2019, just before the COVID-19 shutdown, the ICEE laboratory underwent a major renovation, gearing it towards in-depth PAHs in H O ice research under relevant solar systems and interstellar conditions. The ICEE facility enables us to study the processing of PAHs in H O ice using UV photons and charged particle (electron) irradiation either singly or in combination under ultra-high vacuum and low temperature (15K). We use in-situ measurements with IR, Raman, and mass spectra by which we monitor the chemistry of PAHs in H O ice before, during and after the irradiation. This presentation will summarize the past work regarding PAHs in ices and provide an update on the latest ICEE research results in this area, outlining a roadmap for future research efforts.

Andrew Mattioda↗

First N 2 Profile for Venus’ Deep Lower Atmosphere

We present the first N 2 profile for Venus’ deep lower atmosphere (<15 km) and a constrained isotopic composition for cloud N 2 [1]. This work directly addresses unresolved questions for Venus using legacy observations. Prior to this work, there were no reported measurements for N 2 abundances at <15 km and the isotopic composition remained unconstrained [2]. The N 2 parameters are critical to understanding the evolution and thermal properties of the atmosphere [3-7]. Our N 2 results were obtained by re-analysis of data acquired in 1978 by the Pioneer Venus Large Probe Neutral Mass Spectrometer (LNMS) [8]. The archived mass spectra from 64.2 to 0.2 km were treated using the analytical procedures specifically developed for the LNMS [9-11]. Judicious peak fitting permitted disambiguation of (A) N 2 + and CO + at 28 u and (B) 14 N 15 N+, 13 CO + , and C 2 H 5 + at 29 u. Quality controls included comparing the (A) LNMS CO + /CO 2 + ratios to the NIST database and literature and (B) fitted counts for CO + to the expected counts of CO + calculated from C 18 O + and 13 CO + using the LNMS 16 O/ 18 O and 12 C/ 13 C ratios (obtained from CO 2 ). Our results show that N 2 is uniformly mixed across the deep lower atmosphere between ~0.2 and 15 km (2.49 ± 0.10 v%). In contrast, N 2 is non-uniformly mixed across the sub-cloud atmosphere and clouds (~15–59 km), where N 2 abundances increase by ~ 2-fold between ~15 km (2.45 ± 0.32 v%) and ~59-51 km (5.21 ± 0.18 v%). Using the cloud data, we also obtained a constrained 15 N/ 14 N ratio (2.93×10 -3 ± 0.13×10 -3 ) and δ 15 N value (-204 ± 35‰). Thus, the LNMS results [1] suggest that (A) the atmosphere is unstable at <15 km, (B) N 2 is not well-mixed >15 km, and (C) the cloud δ 15 N falls between Earth and the solar wind [12, 13]. Comparisons of the N 2 abundances and isotopic compositions for nitrogen, carbon, and oxygen to other Venus measurements will be discussed.

deep lower atmosphere↗

Thermal Conductivity and Seebeck Coefficients of Icosahedral Boron Arsenide Films on Silicon Carbide

The thermal conductivity of icosahedral boron arsenide (B{sub 12}As{sub 2}) films grown on (0001) 6H-SiC substrates by chemical vapor deposition was studied by the 3{omega} technique. The room temperature thermal conductivity decreased from 27.0 to 15.3 W/m K as the growth temperature was decreased from 1450 to 1275 C. This is mainly attributed to the differences in the impurity concentration and microstructure, determined from secondary ion mass spectrometry and high resolution transmission electron microscopy, respectively. Callaway's theory was applied to calculate the temperature-dependent thermal conductivity, and the results are in good agreement with the experimental data. Seebeck coefficients were determined as 107 {micro}V/K and 136 {micro}V/K for samples grown at 1350 C with AsH{sub 3}/B{sub 2}H{sub 6} flow ratio equals to 1:1 and 3:5, respectively.

36 MATERIALS SCIENCE↗

Soft ionization of thermally evaporated hypergolic ionic liquid aerosols

Isolated ion pairs of a conventional ionic liquid, 1-Ethyl-3-Methyl-Imidazolium Bis(trifluoromethylsulfonyl)imide ([Emim+][Tf2N?]), and a reactive hypergolic ionic liquid, 1-Butyl-3-Methyl-Imidazolium Dicyanamide ([Bmim+][Dca?]), are generated by vaporizing ionic liquid submicron aerosol particles for the first time; the vaporized species are investigated by dissociative ionization with tunable vacuum ultraviolet (VUV) light, exhibiting clear intact cations, Emim+ and Bmim+, presumably originating from intact ion pairs. Mass spectra of ion pair vapor from an effusive source of the hypergolic ionic liquid show substantial reactive decomposition due to the internal energy of the molecules emanating from the source. Photoionization efficiency curves in the near threshold ionization region of isolated ion pairs of [Emim+][Tf2N?]ionic liquid vapor are compared for an aerosol source and an effusive source, revealing changes in the appearance energy due to the amount of internal energy in the ion pairs. The aerosol source has a shift to higher threshold energy (~;;0.3 eV), attributed to reduced internal energy of the isolated ion pairs. The method of ionic liquid submicron aerosol particle vaporization, for reactive ionic liquids such as hypergolic species, is a convenient, thermally ?cooler? source of isolated intact ion pairs in the gas phase compared to effusive sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗