Moessbauer spectroscopy and magnetic characteristics of Zn{sub 1-x}Co{sub x}Fe{sub 2}O{sub 4} (x = 0-1) nanoparticles

Zn{sub 1-x}Co{sub x}Fe{sub 2}O{sub 4} (x = 0-1 in a step of 0.2) nanoparticles with different range of particle size including 5-10 nm and 200-250 nm have been prepared by sol-gel process. Moessbauer spectra at room temperature indicated that, with increasing cobalt content, there is a transition from paramagnetic to magnetically ordered-ferrimagnetic state. Magnetic properties were measured at 300 and 10 K using a Quantum Design MPMS-5S SQUID magnetometer. It was found that with an increase in cobalt content the saturation magnetization and coercivity increase.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Study on ion-irradiation-induced ferromagnetism in FeRh intermetallic compound by means of magnetic Compton scattering

The magnetic Compton profiles of Fe-50 at. % Rh intermetallic compound were measured to study the ferromagnetism induced by 200 MeV Xe ion irradiation. The magnetic effect at 50 K increases with increasing the ion-fluence. The analysis of the experimental result revealed that the values of spin moment induced by the irradiation were close to the values of magnetization obtained by a superconducting quantum interference device magnetometer, suggesting that the ion irradiation mainly induces the spin magnetic moment. The difference in magnetic Compton profiles between the irradiation-induced ferromagnetism and the intrinsic ferromagnetism in pure Fe is also discussed.

36 MATERIALS SCIENCE↗

Invited Review Article: Gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion devices

Gas puff imaging (GPI) is a diagnostic of plasma turbulence which uses a puff of neutral gas at the plasma edge to increase the local visible light emission for improved space-time resolution of plasma fluctuations. This paper reviews gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion research, with a focus on the instrumentation, diagnostic cross-checks, and interpretation issues. The gas puff imaging hardware, optics, and detectors are described for about 10 GPI systems implemented over the past similar to 15 years. Comparison of GPI results with other edge turbulence diagnostic results is described, and many common features are observed. Here, several issues in the interpretation of GPI measurements are discussed, and potential improvements in hardware and modeling are suggested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unsupervised learning about 4D features of microparticle motion

Material clusters of different sizes are known to exist in high-temperature plasmas due to plasma-wall interactions. The facts that these clusters, ranging from sub-microns to above mm in size, can move from one location to another quickly and that there are a lot of them make high-speed imaging and tracking one of the best, effective, and sometimes only diagnostic. An unsupervised machine learning technique based on deconvolutional neural networks is developed to analyze two-camera videos of high-temperature microparticles generated from exploding wires. The neural network utilizes a locally competitive algorithm to infer representations and optimize a dictionary composed of kernels, or basis vectors, for image analysis. Our primary goal is to use this method for feature recognition and prediction of the time-dependent three-dimensional (or “4D”) microparticle motion. Features equivalent to local velocity vectors have been identified as the dictionary kernels or “building blocks” of the scene. The dictionary elements from the left and right camera views are found to be strongly correlated and satisfy the projection geometrical constraints. The results show that unsupervised machine learning techniques are promising approaches to process large sets of images for high-temperature plasmas and other scientific experiments. In conclusion, machine learning techniques can be useful to handle the large amount of data and therefore aid the understanding of plasma-wall interaction.

47 OTHER INSTRUMENTATION↗

Terahertz BWO spectroscopy of conductors and superconductors

Methods for direct (without the use of the Kramers-Kronig relations) measuring the dielectric response (dynamic conductivity and permittivity) spectra of dielectrics, conductors, and superconductors in the terahertz frequency range (0.03-1.5 THz) are described. The methods are realised by using BWO (backward-wave oscillator) spectrometers developed at the A.M. Prokhorov General Physics Institute, RAS. Dielectric measurements can be performed at temperatures from 2 to 1000 K in magnetic fields up to 8 T. The dielectric response spectra are investigated for a number of materials with properties determined by electron correlation effects: superconductors, one-dimensional conductors, heavy fermion systems, spin-ladder cuprates, and spin glasses. (special issue devoted to the 25th anniversary of the a.m. prokhorov general physics institute)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Iron Oxides

Abstract: Fe oxides are common clay-sized oxide, oxyhydroxide and hydroxide soil minerals. They are compounds of Fe, O, and H that have structures based on close-packed arrays of O. The octahedral and tetrahedral cavities within these arrays are filled with either Fe3+ or Fe2+ to form Fe(O/OH)6, FeO6, or FeO4 structural units. All of the naturally occurring Fe oxide minerals usually undergo some degree of isomorphous substitution of other metal ions for Fe in their structures. Relatively simple techniques may be used to identify Fe oxides in the field based on their typical colors and magnetic properties. In the laboratory, a variety of instrumental techniques can be used to confirm phase identity and to quantify amount. Of these, X-ray diffraction, infrared spectroscopy, electron microscopy, thermal analysis, and Mössbauer spectroscopy are the most commonly used techniques. As oxides, the functional groups on their surfaces may have positive, negative, or no charge depending on pH and on the concentration and nature of other ions in the contact solution. A net positive surface charge usually is observed in soils because Fe oxides have a point-of-zero-charge in the neutral or slightly basic pHs. The functional groups on the surface form complexes with cations and anions from the aqueous phase. Their sorption and electron-buffering properties significantly affect the geochemical cycles of almost all elements having agronomic or environmental significance.

electron-transfer chemistry↗

CORONAE AS A CONSEQUENCE OF LARGE-SCALE MAGNETIC FIELDS IN TURBULENT ACCRETION DISKS

Non-thermal X-ray emission in compact accretion engines can be interpreted to result from magnetic dissipation in an optically thin magnetized corona above an optically thick accretion disk. If coronal magnetic field originates in the disk and the disk is turbulent, then only magnetic structures large enough for their turbulent shredding time to exceed their buoyant rise time survive the journey to the corona. We use this concept and a physical model to constrain the minimum fraction of magnetic energy above the critical scale for buoyancy as a function of the observed coronal to bolometric emission. Our results suggest that a significant fraction of the magnetic energy in accretion disks resides in large-scale fields, which in turn provides circumstantial evidence for significant non-local transport phenomena and the need for large-scale magnetic field generation. For the example of Seyfert active galactic nuclei, for which approx30% of the bolometric flux is in the X-ray band, we find that more than 20% of the magnetic energy must be of large enough scale to rise and dissipate in the corona.

79 ASTRONOMY AND ASTROPHYSICS↗

XMM-NEWTON OBSERVATIONS OF HD 189733 DURING PLANETARY TRANSITS

We report on two XMM-Newton observations of the planetary host star HD 189733. The system has a close in planet and it can potentially affect the coronal structure via interactions with the magnetosphere. We have obtained X-ray spectra and light curves from EPIC and the Reflection Grating Spectrometer on board XMM-Newton which we have analyzed and interpreted. We reduced X-ray data from the primary transit and secondary eclipse that occurred on 2007 April 17 and 2009 May 18, respectively. In the 2007 April observation, only variability due to weak flares is recognized. In 2009 HD 189733 exhibited an X-ray flux that was always larger than in the 2007 observation. The average flux in 2009 was higher than in the 2007 observation by a factor of 45%. During the 2009 secondary eclipse we observed a significant softening of the X-ray spectrum at a level of {approx}3{sigma}. Furthermore, we observed the most intense flare recorded at either epoch. This flare occurred 3 ks after the end of the eclipse. The flare decay shows several minor ignitions perhaps linked to the main event and hinting at secondary loops that are triggered by the main loop. Magnetohydrodynamic (MHD) simulations show that the magnetic interaction between planet and star enhances the density and the magnetic field in a region between the planet and the star because of their relative orbital/rotation motion. X-ray observations and model predictions are globally found in agreement, despite the quite simple MHD model and the lack of precise estimate of parameters including the alignment and the intensity of stellar and planetary magnetic fields. Future observations should confirm or disprove this hypothesis, by determining whether flares are systematically recurring in the light curve at the same planetary phase.

79 ASTRONOMY AND ASTROPHYSICS↗

FEM models and Fourier decomposition of three thick septa

Here, the CEBAF recirculating linear accelerator uses 26 septa: 8 thin, 17 thick and one Lamberston. We report here on detailed FEM models of one thick current-sheet septum, the Lambertson, and a new thick-septum concept which contains features of both. The last has higher-order field components within a factor of two of the current-sheet septum and much lower current density in the conductor were it used as a 'drop-in' replacement in CEBAF. There are accelerator layouts in which the new concept is superior to the current sheet septum in both harmonic content and current density.

47 OTHER INSTRUMENTATION↗

Adjustable microchip ring trap for cold atoms and molecules

We describe the design and function of a circular magnetic waveguide produced from wires on a microchip for atom interferometry using de Broglie waves. The guide is a two-dimensional magnetic minimum for trapping weak-field seeking states of atoms or molecules with a magnetic dipole moment. The design consists of seven circular wires sharing a common radius. We describe the design, the time-dependent currents of the wires and show that it is possible to form a circular waveguide with adjustable height and gradient while minimizing perturbation resulting from leads or wire crossings. This maximal area geometry is suited for rotation sensing with atom interferometry via the Sagnac effect using either cold atoms, molecules and Bose-condensed systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoionization microscopy of the hydrogen atom in parallel electric and magnetic fields

In photoionization microscopy experiments, an atom in an electric field is ionized by a laser with sharply defined frequency, the electron is drawn toward a position-sensitive detector, and the current is measured as a function of position. Multiple classical paths lead from the atom to any point in the classically allowed region on the detector, and waves traveling along these paths produce an interference pattern. If a magnetic field is added parallel to the electric field, trajectories become chaotic. There is an infinite set of different families of trajectories, leading to an extremely complicated interference patterns on the detector. We present calculations predicting the kind of structure that will be seen in experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurements of the magnetic field vector using multiple electromagnetically induced transparency resonances in Rb vapor

We study the dependence of electromagnetically induced transparency (EIT) resonance amplitudes on the external magnetic field direction in a linearly polarized bichromatic light (lin||lin) configuration in {sup 87}Rb vapor. We demonstrate that all seven resolvable EIT resonances exhibit maxima or minima at certain orientations of the laser polarization relative to the wave vector and magnetic field. This effect can be used for the development of a high-precision EIT vector magnetometer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accurate evolutions of inspiralling and magnetized neutron stars: Equal-mass binaries

By performing new, long and numerically accurate general-relativistic simulations of magnetized, equal-mass neutron-star binaries, we investigate the role that realistic magnetic fields may have in the evolution of these systems. In particular, we study the evolution of the magnetic fields and show that they can influence the survival of the hypermassive neutron star produced at the merger by accelerating its collapse to a black hole. We also provide evidence that, even if purely poloidal initially, the magnetic fields produced in the tori surrounding the black hole have toroidal and poloidal components of equivalent strength. When estimating the possibility that magnetic fields could have an impact on the gravitational-wave signals emitted by these systems either during the inspiral or after the merger, we conclude that for realistic magnetic-field strengths B < or approx. 10{sup 12} G such effects could be detected, but only marginally, by detectors such as advanced LIGO or advanced Virgo. However, magnetically induced modifications could become detectable in the case of small-mass binaries and with the development of gravitational-wave detectors, such as the Einstein Telescope, with much higher sensitivities at frequencies larger than {approx_equal}2 kHz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematic Measurements of Ion-Proton Differential Streaming in the Solar Wind

The small amount of heavy ions in the highly rarefied solar wind are sensitive tracers for plasma-physics processes, which are usually not accessible in the laboratory. We have analyzed differential streaming between heavy ions and protons in the solar wind at 1 AU. 3D velocity vector and magnetic field measurements from the Solar Wind Electron Proton Alpha Monitor and the Magnetometer aboard the Advanced Composition Explorer were used to reconstruct the ion-proton difference vector v{sub ip}=v{sub i}-v{sub p} from the 12 min 1D Solar Wind Ion Composition Spectrometer observations. We find that all 44 analyzed heavy ions flow along the interplanetary magnetic field at velocities which are smaller than, but comparable to, the local Alfven speed C{sub A}. The flow speeds of 35 of the 44 ion species lie within the range of {+-}0.15C{sub A} around 0.55C{sub A}, the flow speed of He{sup 2+}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Mu2e Solenoid Cold Mass Position Monitor System

The Mu2e experiment at Fermilab is designed to search for charged-lepton flavor violation by looking for muon to electron conversions in the field of the nucleus. The concept of the experiment is to generate a low momentum muon beam, stopping the muons in a target and measuring the momentum of the outgoing electrons. The implementation of this approach utilizes a complex magnetic field composed of graded solenoidal and toroidal fields. The location of the solenoid cold mass relative to external fiducials is needed for alignment as well as monitoring coil movements during cool down and magnet excitation. This study describes a novel design of a Cold Mass Position Monitor System (CMPS) that will be implemented for the Mu2e experiment.

43 PARTICLE ACCELERATORS↗

Structure-mechanical properties correlation in bulk LiPON glass produced by nitridation of metaphosphate melts

The glassy solid electrolyte Lithium phosphorous oxynitride (LiPON) has been widely researched in thin film solid state battery format due to its outstanding stability when cycled against lithium. In addition, recent reports show thin film LiPON having interesting mechanical behaviors, especially its ability to resist micro-scale cracking via densification and shear flow. Here, in the present study, we have produced bulk LiPON glasses with varying nitrogen contents by ammonolysis of LiPO 3 melts. The resulting compositions were determined to be LiPO 3-3z/2 N z , where 0 ≤ z ≤ 0.75, and the z value of 0.75 is among the highest ever reported for this series of LiPON glasses. The short-range order structures of the different resulting compositions were characterized by infrared, Raman, 31 P magic angle spinning nuclear magnetic resonance, and X-ray photoelectron spectroscopies. Instrumented nano-indentation was used to measure mechanical properties. It was observed that similar to previous studies, both trigonally coordinated (N t ) and doubly bonded (N d ) N co-exist in the glasses in about the same amounts for z ≤ 0.36, the limit of N content in most previous studies. For glasses with z > 0.36, it was found that the fraction of the N t increased significantly while the fraction of N d correspondingly decreased. The incorporation of nitrogen increased both the elastic modulus and hardness of the glass by approximately a factor of 1.5 when N/P ratio reaches 0.75. At the same time, an apparent embrittlement of the glass was observed due to nitridation, which was revealed by nanoindentation with an extra sharp nanoindenter tip.

25 ENERGY STORAGE↗

Undulator Field Integral Measurements

The LCLS undulator field integrals must be very small so that the beam trajectory slope and offset stay within tolerance. In order to make accurate measurements of the small field integrals, a long coil will be used. This note describes the design of the coil measurement system.

43 PARTICLE ACCELERATORS↗

Magnetic Tape Recording

NASA's contribution to tape recorder technology may appear to lie in such glamorous devices as the tape recorders of the Tiros and Nimbus satellites which receive signals carrying weather information during an orbit around the earth and then transmit those signals back to the ground when the satellite is in view of ground stations. These quite important recording devices are, however, only useful as members of a complex hierarchy of devices all of which participate in the ultimate process of obtaining information from NASA's efforts. Their existence and utility is based on the existence of many more prosaic recording devices which have been involved in the development of such spectacular units.