Continuum laser absorption spectroscopy of C 2 (a 3 Π u ) in a sublimating cloud of carbon black

A direct optical absorption diagnostic has been developed for rotationally resolved measurements of diatomic carbon (a 3 Π u →d 3 Π g (0,0) and (1,1)) at a repetition rate of 525 kHz and resolution of 7.3 pm over the range of 511.1–514.1 nm. The diagnostic utilizes a high-power pulsed continuum laser light source dispersed in a spectrograph and imaged by a high-speed camera. Measurements have been performed that capture the temporal evolution of C 2 number density and temperature of a cloud of carbon black sublimating in shock heated gas at high temperature and pressure (T = 5500 K, P = 3.7 atm). A simultaneous light absorption measurement of the condensed phase enables comparisons of the gaseous C 2 number density to the condensed phase mass. The continuum laser absorption diagnostic is applied to C 2 in this work but shows promise in being a simple “drop-in” system for absorption spectroscopy in the visible range at rapid repetition rates and high dispersion, filling an important gap for laser diagnostic systems.

Willhardt, Colton Dean [Univ. of Illinois at Urban↗

Design, Build, and Testing of the Roman Space Telescope’s Wide Field Instrument Optical Stimulus System (SORC)

The Stimulus Of Ray Cones (SORC) is an optical stimulus system developed to verify, characterize, and calibrate the Roman Space Telescope’s (RST) Wide Field Instrument (WFI) under simulated operational conditions. SORC provides several critical test modes, the primary being point-source mode, which projects an image anywhere on the Focal Plane Assembly (FPA) detectors. This mode provides precise position knowledge of the FPA within WFI. Additional modes enable capturing WFI pupil alignment, evaluation of WFI’s selectable optical elements, and verification of focal plane fiber operation for higher-level system testing. The light source system incorporates a suite of narrowband and broadband fiber fed sources spanning the visible to near-infrared range, with options for pulsed or continuous wave illumination. SORC was designed and built at NASA’s Goddard Spaceflight Center (GSFC). Initial system-level testing occurred under ambient conditions in GSFC’s Spacecraft Systems Development and Integration Facility (SSDIF), followed by vacuum testing at operational temperatures (SORC at 214-222 K) in the Space Environment Simulator (SES). The system was then shipped to BAE Systems in Boulder, CO for post-shipment ambient and cryogenic testing before integration with WFI for two thermal vacuum test campaigns at cryogenic temperatures. This presentation will focus on design, development, and performance of SORC. Details of WFI verification and calibration using SORC, along with test results, have been published previously and will be referenced only as needed to describe SORC. The SORC ground test capability is critical to ensuring WFI meets stringent optical performance requirements, directly supporting the mission’s science objectives.

Stimulus of Ray Cones↗

Cost Estimates of Roll-to-Roll Production of Organic Light Emitting Devices for Lighting

White organic light emitting devices (WOLEDs) offerdistinct advantages as solid state lighting sources, including high energy efficiency, superior color quality,and a flexible, thin profile that can accommodate a vast array of possible fixture designs. Recent advances in device lifetime and high speed deposition suggest that mass production of WOLED panels is approaching an inflection point. To understand the tradeoffs in the volume manufacturing of WOLED lighting panels, in this work, we estimate the cost of white WOLED panel production based on vacuum and vapor phase deposition in a roll-to-roll production line envisioned to yield an annual capacity of at least 6 × 10 6 m 2 . Assuming a WOLED operating luminance at 10 klm/m 2 , we anticipate a $\$12.5$ /klm cost of a WOLED light engine that includes the cost of the current driverand packaging. With incremental reduction in material and driver costs and improved luminance, the costof WOLED lighting can be reduced to $\$6.3$ /klm in thenear term, potentially positioning WOLEDs for use innumerous premium lighting applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoselective isotope fractionation dynamics of N 2 with cosmo and atmospheric chemistry perspectives

Stable isotope ratio measurements provide valuable insights into a broad range of natural processes, from planetary atmospheres and climate to interstellar chemistry. Nitrogen, which has two stable isotopes, exhibits varying isotope ratios across the solar system. To model these observations, the isotope fraction as a function of energy is essential. At the Advanced Light Source (ALS), we measured the photodissociation of molecular nitrogen (N 2 ) with vacuum UV photons where a single photon is sufficiently energetic to dissociate the strong bond. The nitrogen atoms produced are scavenged with H 2 to form ammonia, whose isotopic makeup is determined. Blending the experiments with dynamical computations that include the shielding of light, we examine the isotopic composition and electronic atomic states produced. The measured photodissociation of N 2 at a natural isotopic composition with a frequency broad light beam exceptionally strongly favors the formation of the heavier nitrogen isotope, 15 N. Computations concur and suggest that the maximum in the quantum yield reflects significant variations in the specific electronic quantum states of the product N atoms that have quite different reactivities. Our quantum computations show that at similar energies, photodissociation of 14 N 14 N and 15 N 14 N can lead to different product channels. The computed dynamics include extensive state-selective spin–orbit and nonadiabatic couplings affecting the light absorption and dissociation pathways that proceed via the triplet manifold of states. Our results are relevant for future exploration missions, both in situ and sample-return and for other molecules such as O 2 and CO.

Komarova, Ksenia [Hebrew Univ. of Jerusalem (Israe↗

Grain size dependence of thermally induced oxidation in zirconium carbide

Here complementary analytical approaches were employed to probe the effect of grain size on thermally induced oxidation of zirconium carbide (ZrC) utilizing thermogravimetric analysis, differential scanning calorimetry, and Raman spectroscopy, as well as synchrotron-based and laboratory-based X-ray diffraction (XRD) experiments. The oxidation mechanism and phase behavior of nanocrystalline ZrC (grain size ~ 20 nm) were compared with that of the more documented microcrystalline ZrC (grain size ~ 1 µm). Synchrotron XRD at the Advanced Photon Source with a hydrothermal diamond anvil cell (HDAC) used as a sample chamber revealed that the onset of oxidation is at ~ 380 °C for microcrystalline ZrC which is in agreement with previous work. In contrast, the critical oxidation temperature was ~ 330 °C for nanocrystalline ZrC. Additional high-temperature synchrotron XRD experiments at the National Synchrotron Light Source II using a lamp furnace in combination with Raman analysis showed that tetragonal ZrO 2 forms as an initial oxidation product and transforms at higher temperatures to the monoclinic phase. Thermogravimetric analysis (TGA) coupled with differential scanning calorimetry (DSC) confirmed the X-ray results of a lower critical oxidation temperature for the nanocrystalline sample. The phase transformations in the oxide phase with associated critical temperatures were also evident in the thermodynamic data as exothermic heat events.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Open Source Perovskite Solar Cell Curve Tracer

When developing systems for perovskite solar cells (PSCs), it is important to have a testing platform that closely resembles your deployed systems. While developing a 1 U CubeSat, the Big Red Sat-1 at the University of Nebraska-Lincoln, we found a lack of passive curve tracing instrumentation, which we needed for our mission. To that end, we developed a benchtop passive curve tracer that leverages the Ossila Solar Simulator as an AM1.5 light source. This device utilizes a ladder of switched resistors and a precision voltage and current measurement to achieve the curve tracing. It also integrates a common-anode multiplexer to switch through multipixel PSCs. Finally, the solar cell holder is separate from the main measurement system, so various substrates sizes and pixel counts can be supported. This system is tested using various PSCs. It has been open sourced to enable reuse in future systems that may benefit from the lower power consumption and flight heritage.

14 SOLAR ENERGY↗

Discharge lamp technologies

This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advances.

Dakin, James↗

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors↗

Lightwave-driven electron emission for polarity-sensitive terahertz beam profiling

The full exploitation of advanced light sources in the terahertz (THz) frequency range requires versatile experimental tools to fully characterize the spatial, temporal, and spectral shapes of the THz electric field. Several techniques for passive THz beam profiling exist that offer information about the temporally integrated intensity. Thus, any information about the electric field itself is lost. Here, we show that a UV–visible light emission produced via a lightwave-driven field emission from single-layer metasurfaces can be used to visualize the peak electric field distribution of THz beams in real time. Our technique is scalable up to frequencies approaching the plasma frequency of the metal used for the metasurface. Uniquely, our device is sensitive to the absolute polarity of the THz lightwave. These findings demonstrate a general pathway to designing metamaterial-based field-sensitive optical detectors suitable for the entire THz and IR spectral region.

42 ENGINEERING↗

M/P Ratios—A Call for Consistency

This is an article for the Illuminating Engineering Society's LD+A magazine. It addresses Melanopic/Photopic ratios, a metric that roughly calculates the portion of the visible spectrum from a light source that contributes to the ipRGC response, relative to the traditional photopic response. The paper explains weighting functions, and that there are four ways to calculate M/P ratios. These four methods produce different values, so it is incumbent on recommendations for M/P ratios (usually for health-related design) to list the method to use. Better still, the lighting and medical communities should standardize on one approach.

M/P ratios, melanopic/photopic ratios, spectral we↗

Enhancement of phototropic response to a range of light doses in Triticum aestivum coleoptiles in clinostat-simulated microgravity

The phototropic dose-response relationship has been determined for Triticum aestivum cv. Broom coleoptiles growing on a purpose-built clinostat apparatus providing gravity compensation by rotation about a horizontal axis at 2 rev min-1. These data are compared with data sets obtained with the clinostat axis vertical and stationary, as a 1 g control, and rotating vertically to examine clinostat effects other than gravity compensation. Triticum at 1 g follows the well-established pattern of other cereal coleoptiles with a first positive curvature at low doses, followed by an indifferent response region, and a second positive response at progressively increasing doses. However, these response regions lie at higher dose levels than reported for Avena. There is no significant difference between the responses observed with the clinostat axis vertical in the rotating and stationary modes, but gravity compensation by horizontal rotation increases the magnitude of first and second positive curvatures some threefold at 100 min after stimulation. The indifferent response is replaced by a significant curvature towards the light source, but remains apparent as a reduced curvature response at these dose levels.

Non-NASA Center↗

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗

The Micro-Arcsecond Metrology Testbed

The Micro-Arcsecond Metrology (MAM) testbed is a ground-based system of optical and electronic equipment for testing components, systems, and engineering concepts for the Space Interferometer Mission (SIM) and similar future missions, in which optical interferometers will be operated in outer space. In addition, the MAM testbed is of interest in its own right as a highly precise metrological system. The designs of the SIM interferometer and the MAM testbed reflect a requirement to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer with sufficient spatial resolution to generate astrometric data with angular resolution at the microarcsecond level. The internal path is to be measured by use of a small metrological laser beam of 1,319-nm wavelength, whereas the position of the starlight fringe is to be estimated by use of a charge-coupled-device (CCD) image detector sampling a large concentric annular beam. For the SIM to succeed, the optical path length determined from the interferometer fringes must be tracked by the metrological subsystem to within tens of picometers, through all operational motions of an interferometer delay line and siderostats. The purpose of the experiments performed on the MAM testbed is to demonstrate this agreement in a large-scale simulation that includes a substantial portion of the system in the planned configuration for operation in outer space. A major challenge in this endeavor is to align the metrological beam with the starlight beam in order to maintain consistency between the metrological and starlight subsystems at the system level. The MAM testbed includes an optical interferometer with a white light source, all major optical components of a stellar interferometer, and heterodyne metrological sensors. The aforementioned subsystems are installed in a large vacuum chamber in order to suppress atmospheric and thermal disturbances. The MAM is divided into two distinct subsystems: the test article (TA), which is the interferometer proper, and the inverse interferometer pseudo-star (IIPS), which synthesizes the light coming from a distant target star by providing spatially coherent wavefronts out of two mirrors, separated by the MAM baseline, that feed directly into two siderostats that are parts of the TA. The two feed mirrors of the IIPS are articulated (in translation and tilt) in order to simulate stars located at different orientations in space, while still illuminating the TA siderostats. The spectrum of the simulated starlight of the IIPS corresponds to that of a blackbody at a temperature of about 3,100 K.

Goullioud, Renaud↗

Integration and Testing of the Lunar Reconnaissance Orbiter Attitude Control System

Throughout the Lunar Reconnaissance Orbiter (LRO) Integration and Testing (I&T) phase of the project, the Attitude Control System (ACS) team completed numerous tests on each hardware component in ever more flight like environments. The ACS utilizes a select group of attitude sensors and actuators. This paper chronicles the evolutionary steps taken to verify each component was constantly ready for flight as well as providing invaluable trending experience with the actual hardware. The paper includes a discussion of each ACS hardware component, lessons learned of the various stages of I&T, a discussion of the challenges that are unique to the LRO project, as well as a discussion of work for future missions to consider as part of their I&T plan. LRO ACS sensors were carefully installed, tested, and maintained over the 18 month I&T and prelaunch timeline. Care was taken with the optics of the Adcole Coarse Sun Sensors (CSS) to ensure their critical role in the Safe Hold mode was fulfilled. The use of new CSS stimulators provided the means of testing each CSS sensor independently, in ambient and vacuum conditions as well as over a wide range of thermal temperatures. Extreme bright light sources were also used to test the CSS in ambient conditions. The integration of the two SELEX Galileo Star Trackers was carefully planned and executed. Optical ground support equipment was designed and used often to check the performance of the star trackers throughout I&T in ambient and thermal/vacuum conditions. A late discovery of potential contamination of the star tracker light shades is discussed in this paper. This paper reviews how each time the spacecraft was at a new location and orientation, the Honeywell Miniature Inertial Measurement Unit (MIMU) was checked for data output validity. This gyro compassing test was performed at several key testing points in the timeline as well as several times while LRO was on the launch pad. Sensor alignment tests were completed several times to ensure that hardware remained on a rigid platform.

Simpson, Jim↗

LCLS-II helium cryoplant and cryo distribution system installation

The helium cryoplant and cryo distribution system (CDS) are key elements of the new superconducting Linac Coherent Light Source (LCLS-II) and will provide superfluid helium to the accelerator. The cryoplant consists of two helium refrigerators with an equivalent 4.5 K refrigeration capacity of 18 kW each. The 37 cryomodules of the LINAC will be operated at a temperature of 2.0 K to accelerate a 4 GeV electron beam that will generate extremely bright X-ray laser light. Two five-stage cold compressor cold boxes will be utilized to provide superfluid helium II for the superconducting cavity structures with a total cooling capacity of 8 kW at 2.0 K. This paper describes the installation of the LCLS-II cryoplant and CDS. The LCLS-II cryoplant was designed and contributed by Jefferson Lab. To expedite the project completion the reuse of proven design and technology from the Jefferson Lab CHL-2 cryoplant was the preferred strategy. The CDS consists of ~260 m thermally shielded and vacuum super insulated transfer lines, two distribution boxes and eight feed and end caps, and was designed and contributed by Fermilab. SLAC installed the cryoplant components into a newly erected building and the CDS components into the existing accelerator tunnel and klystron gallery with strong engineering support from both partner labs.

43 PARTICLE ACCELERATORS↗

Accelerating Control Systems with GitOps: A Path to Automation and Reliability

GitOps is a foundational approach for modernizing infrastructure by leveraging Git as the single source of truth for declarative configurations. The poster explores how GitOps transforms traditional control system infrastructure, services and applications by enabling fully automated, auditable, and version-controlled infrastructure management. Cloud-native and containerized environments are shifting the ecosystem not only in the IT industry but also within the computational science field, as is the case of CERN and Diamond Light Source among other Accelerator/Science facilities which are slowly shifting towards modern software and infrastructure paradigms. The ACORN project, which aims to modernize Fermilab’s control system infrastructure and software is implementing proven best-practices and cutting-edge technology standards including GitOps, containerization, infrastructure as code and modern data pipelines for control system data acquisition and the inclusion of AI/ML in our accelerator complex.

Gonzalez, M. [Fermilab]↗

Dual wavelength negative imaging DLP-SLA system

The present disclosure relates to a digital light projector (DLP) system which has first and second light sources. The first optical source may generate a first beam at a first wavelength which causes polymerization of a photopolymerizable resist. The second optical source may generate a second beam at a second wavelength different from the first wavelength, and where the second beam inhibits polymerization of the photopolymerizable resist. A digital micromirror device (DMD) is included which has a plurality of micromirrors and is configured to be illuminated by the first and second beams and to generate a pattern on the micromirrors which has light from the first and second light wavelengths controlled by the micromirror position. The first light image causes polymerization of a first portion of the photopolymerizable resist, while the second image inhibits polymerization of a second portion of the photopolymerizable resist.

Moran, Bryan D.↗

UV laser long-path absorption spectroscopy

Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.

Dorn, Hans-Peter↗