Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A payload to evaluate photodiodes for the detection of soft and hard x rays in a space environment using a Get Away Special

We propose to use the Get Away Special (GAS) facility to evaluate P-intrinsic-N (PIN) detectors and avalanche photodiodes (APD's) for the detection of both solar and nonsolar soft and hard x rays. We would like to fly both types of silicon detectors for the direct detection of the x ray photons in the energy range from 1 to 30 keV with an energy resolution of about 1 keV. We would also like to use both types of photodiodes viewing CsI(Tl) scintillators to extend the energy range up to 1 MeV with -6 percent resolution at 660 keV. Solar flares would be detected with this instrumentation during periods of solar pointing providing high energy resolution spectra with high time resolution. Similar data would be obtained in the scanning mode on nonsolar transient and steady x ray sources with the same instrumentation. A commandable door over the detectors would be required to allow measurements to be made as low as 1 keV.

Desai, Upendra D.↗

Why would you put a flashlight in a dark matter detector?

Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, could potentially degrade the science goals of future xenon dark matter experiments. In this article, we measure the effect of external crosstalk in a dual-phase, liquid xenon time projection chamber fully instrumented with SiPMs. We then consider the implications for a future xenon dark matter experiment utilizing SiPMs and discuss possible solutions.

47 OTHER INSTRUMENTATION↗

Scalable Background-Limited Polarization-Sensitive Detectors for mm-wave Applications

We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.

Millimeter-Wave Detectors↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

Maturing CCD Photon-Counting Technology for Space Flight

This paper discusses charge blooming and starlight saturation - two potential technical problems - when using an Electron Multiplying Charge Coupled Device (EMCCD) type detector in a high-contrast instrument for imaging exoplanets. These problems especially affect an interferometric type coronagraph - coronagraphs that do not use a mask to physically block starlight in the science channel of the instrument. These problems are presented using images taken with a commercial Princeton Instrument EMCCD camera in the Goddard Space Flight Center's (GSFC), Interferometric Coronagraph facility. In addition, this paper discusses techniques to overcome such problems. This paper also discusses the development and architecture of a Field Programmable Gate Array and Digital-to-Analog Converter based shaped clock controller for a photon-counting EMCCD camera. The discussion contained here will inform high-contrast imaging groups in their work with EMCCD detectors.

Mallik, Udayan↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Mapping X-ray heliometer for Orbiting Solar Observatory-8

An instrument combining mechanical collimators and proportional counter detectors was designed to record solar X-rays with energies of 2-30 keV with good temperal, spectral, and spatial resolution. The overall operation of the instrument is described to the degree needed by personnel who interact with the experimenter during SC/experiment interfacing, experiment testing, observatory integration and testing, and pre/post launch data processing. The general layout of the instrument is given along with a summary of the instrument characteristics.

Acton, L. W.↗

Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument

A miniature XRD/XRF (X-ray diffraction / X-ray fluorescence) instrument, CHEMIN, is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed to enable remote XRD analysis is how best to obtain a representative sample powder for analysis. For powder XRD analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a two-dimensional detector as used in the CHEMIN instrument will produce good results even with poorly prepared powder, the quality of the data will improve and the time required for data collection will be reduced if the sample is fine-grained and randomly oriented. A variety of methods have been proposed for XRD sample preparation. Chipera et al. presented grain size distributions and XRD results from powders generated with an Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL. The USDC was shown to be an effective instrument for sampling rock to produce powder suitable for XRD. In this paper, we compare powder prepared using the USDC with powder obtained with a miniaturized rock crusher developed at JPL and with powder obtained with a rotary tungsten carbide bit to powders obtained from a laboratory bench-scale Retsch mill (provides benchmark mineralogical data). These comparisons will allow assessment of the suitability of these methods for analysis by an XRD/XRF instrument such as CHEMIN.

Chipera, S. J.↗

Thunderstorm hazards flight research - Program overview

The NASA thunderstorm hazards research program, designed to study the effects of lightning strikes on the design and operation of aircraft, is described. An all-weather F-106B is instrumented to document the EM characteristics of direct and nearby strikes, measure the field parameters and analyze the ambient atmospheric content, and film the strikes; X-ray detectors are also on board, along with instrumentation for determining the frequency of visible light waveforms. Data is either recorded on-board or sent by telemetry to base, while ground based telemetry is used to direct the pilot and craft into regions of optimal lightning activity. The sensing apparatus is described, and ongoing programs to correlate different storm parameters are reviewed, along with operational procedures and safety precautions. Continued use of the craft through 152 storms and 16 direct hits, with no fatalities or circuit breaker throw, confirms the ability of metal skinned aircraft to withstand lightning strikes; data gathered from flights during 1980 are provided.

Deal, P. L.↗

Mapping crystal defects with a digital scanning ultramicroscope

A computer controlled scanning ultramicroscope has been built to assist in the characterization of transparent crystals. The device measures the scattering of a focused He-Ne laser beam by crystalline defects. As an XYZ translation table moves the crystal under the ultramicroscope, the scattered light is measured by a photodetector whose output is digitized and recorded. From this data, contour maps or three dimensional perspective plots of the scattering regions of the crystal can be generated to assist in finding patterns of defects which might be correlated with perturbations in the growth process. The verified resolution of the present instrument is about 1 micrometer, which is limited by the minimum step of the stepper-motor driven translation stages, optical diffraction effects and the sensitivity of the detector at the laser light frequency. The instrument was used to build a database of defects patterns in commercial laboratory grown triglycine sulphate (TGS) crystals, and to map defects in a TGS crystal grown from aqueous solution during the flight of Spacelab 3. This crystal shows indications of a reduction both in the generation of defects at the seed-new growth interface and in their propagation into the new crystal.

Springer, J. M.↗

In situ detection of tropospheric OH, HO2, NO2, and NO by laser-induced fluorescence in detection chambers at reduced pressures

This report is a brief summary of the status of work on the grant entitled 'In situ detection of tropospheric OH, HO2, NO2, and NO by laser induced fluorescence in detection chambers at low pressures.' The basic instrument characteristics have been established, and have been reported in a manuscript, included as an appendix to this report, that has been accepted by the Journal of Geophysical Research. Currently, two efforts are under way. First, instrument tests and calibrations are continuing. These efforts include field measurements and an informal inter comparison in Colorado last August and September. Second, new technologies in lasers and detectors are being implemented to make the instrument smaller, lighter, and more energy efficient. Such instrument modifications are essential for measurements from aircraft, high scaffolding in forests, and ships.

Brune, William H.↗

Use of an Ultrasonic/Sonic Driller/Corer to Obtain Sample Powder for CHEMIN, a Combined XRD/XRF Instrument

A miniature CHEMIN XRD/XRF (X-Ray Diffraction/X-Ray Fluourescence) instrument is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed in order to enable XRD analysis on an extraterrestrial body is how best to obtain a representative sample powder for analysis. For XRD powder diffraction analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a 2-dimensional detector as used in the CHEMIN instrument will produce good results with poorly prepared powders, the quality of the data will improve if the sample is fine-grained and randomly oriented. An Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL is an effective mechanism of sampling rock to produce cores and powdered cuttings. It requires low axial load (< 5N) and thus offers significant advantages for operation from lightweight platforms and in low gravity environments. The USDC is lightweight (<0.5kg), and can be driven at low power (<5W) using duty cycling. It consists of an actuator with a piezoelectric stack, ultrasonic horn, free-mass, and drill bit. The stack is driven with a 20 kHz AC voltage at resonance. The strain generated by the piezoelectric is amplified by the horn by a factor of up to 10 times the displacement amplitude. The tip impacts the free-mass and drives it into the drill bit in a hammering action. The free-mass rebounds to interact with the horn tip leading to a cyclic rebound at frequencies in the range of 60-1000 Hz. It does not require lubricants, drilling fluid or bit sharpening and it has the potential to operate at high and low temperatures using a suitable choice of piezoelectric material. To assess whether the powder from an ultrasonic drill would be adequate for analyses by an XRD/XRF spectrometer such as CHEMIN, powders obtained from the JPL ultrasonic drill were analyzed and the results were compared to carefully prepared powders obtained using a laboratory bench scale Retsch mill.

Chipera, S. J.↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

NPP VIIRS Geometric Performance Status

Visible Infrared Imager Radiometer Suite (VIIRS) instrument on-board the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP) satellite is scheduled for launch in October, 2011. It is to provide satellite measured radiance/reflectance data for both weather and climate applications. Along with radiometric calibration, geometric characterization and calibration of Sensor Data Records (SDRs) are crucial to the VIIRS Environmental Data Record (EDR) algorithms and products which are used in numerical weather prediction (NWP). The instrument geometric performance includes: 1) sensor (detector) spatial response, parameterized by the dynamic field of view (DFOV) in the scan direction and instantaneous FOV (IFOV) in the track direction, modulation transfer function (MTF) for the 17 moderate resolution bands (M-bands), and horizontal spatial resolution (HSR) for the five imagery bands (I-bands); 2) matrices of band-to-band co-registration (BBR) from the corresponding detectors in all band pairs; and 3) pointing knowledge and stability characteristics that includes scan plane tilt, scan rate and scan start position variations, and thermally induced variations in pointing with respect to orbital position. They have been calibrated and characterized through ground testing under ambient and thermal vacuum conditions, numerical modeling and analysis. This paper summarizes the results, which are in general compliance with specifications, along with anomaly investigations, and describes paths forward for characterizing on-orbit BBR and spatial response, and for improving instrument on-orbit performance in pointing and geolocation.

Lin, Guoqing↗

Overview of the Optical Communications Demonstrator

The Optical Communications Demonstrator is a laboratory-based lasercom demonstration instrument designed to validate effective beacon acquisition, high bandwidth tracking, precision beam pointing, and point ahead compensation functions. The instrument is designed using an array detector for both spatial acquisition and high bandwidth tracking, and a fiber coupled laser transmitter. The array detector tracking concept provides wide field of view acquisition as well as high update rate using a single output channel device. At the same time, it permits effective platform jitter compensation and point ahead control using only one steering mirror. The use of fiber coupled transmitter further modularizes transmitter design and de-couples the thermal management problem. The reduction in design complexity can lead to a reduced system cost and an improved system reliability. Furthermore, it can permit the implementation of a new generation of lasercom instruments capable of realizing the inherent advantages of optical frequency communication systems.

laser↗

The 2.5-12 micrometers spectrum of comet Halley from the IKS-VEGA experiment

The infrared instrument IKS flown on board the VEGA space probes was designed for the detection of emission bands of parent molecules, and for a measurement of the size and temperature of the thermal emitting nuclear region. The instrument had three channels with cooled detectors: an "imaging channel" designed to modulate the signal of the nucleus and two spectroscopic channels operating at 2.5-5 and 6-12 micrometers, respectively, equipped with circular variable filters of resolving power approximately 50. This paper presents and discusses the results from the spectral channels. On VEGA 1, usable spectra were obtained at distances D from the comet nucleus ranging from 250,000 to 40,000 km corresponding to fields of view 4000 and 700 km in diameter, respectively. The important internal background signal caused by the instrument itself, which could not be cooled, had to be eliminated. Since no sky chopping was performed, we obtain difference spectra between the current spectrum and a reference spectrum with little or no cometary signal taken at the beginning of the observing sequence (D approximately 200,000 km). Final discrimination between cometary signal and instrumental background is achieved using their different time evolution, since the instrumental background is proportional to the slow temperature drift of the instrument, and the cometary signal due to parent molecules or dust grains is expected to vary in first order as D-1. The 2.5-5 micrometers IKS spectra definitely show strong narrow signals at 2.7 and 4.25 micrometers, attributed to the nu 3 vibrational bands of H2O and CO2, respectively, and a broader signal in the region 3.2-3.5 micrometers, which may be attributed to CH-bearing molecules. All these signals present the expected D-1 intensity variation. Weaker emission features at 3.6 and 4.7 micrometers could correspond to the nu 1 and nu 5 bands of H2CO and the (1 - 0) band of CO, respectively. Molecular production rates are derived from the observed emissions, assuming that they are due to resonance fluorescence excited by the Sun's infrared radiation. For the strong bands of H2O and CO2, the rovibrational lines are optically thick, and radiative transfer is taken into account. We derive production rates, at the moment of the VEGA 1 flyby, of approximately 10(30) sec-1 for H2O, approximately 2.7 x 10(28) sec-1 for CO2, approximately 5 x 10(28) sec-1 for CO, and 4 x 10(28) sec-1 for H2CO, if attributions to CO and H2CO are correct. The production rate of carbon atoms in CH-bearing molecules is approximately 9 x 10(29) sec-1 assuming fluorescence of molecules in the gas phase, but could be much less if the 3.2-3.5 micrometers emission is attributed to C-H stretch in polycyclic aromatic hydrocarbons or small organic grains. In addition, marginal features are present at 4.85 and 4.45 micrometers, tentatively attributed to OCS and molecules with the CN group, respectively. Broad absorption at 2.8-3.0 micrometers, as well as a narrow emission at 3.15 micrometers, which follow well the D-1 intensity variation, might be due to water ice. Emission at 2.8 micrometers is also possibly present, and might be due to OH created in vibrationally excited states after water photodissociation. The 6-12 micrometers spectrum does not show any molecular emission, nor emission in the 7.5-micrometers region. The spectrum is dominated by silicate emission showing a double structure with maxima at 9.0 and 11.2 micrometers, which suggests the presence of olivine.

NASA Discipline Number 52-10↗

A simple approach for characterizing the spatially varying sensitivity of microchannel plate detectors

Herein we present a simple approach to characterize the spatial variation of the gain in microchannel plate (MCP) coupled to phosphor detectors using single electron or photon hits. The technique is easy to implement and general enough to be extended to other kinds of detectors. We demonstrate the efficacy of the approach on both laboratory and Monte Carlo generated datasets. Furthermore, we use the approach to measure the variation in gain over time as the MCP is exposed to an increasing number of electrons.

47 OTHER INSTRUMENTATION↗

Development of a Space-Flight ADR Providing Continuous Cooling at 50 mK with Heat Rejection at 10 K

Future astronomical instruments will require sub-Kelvin detector temperatures to obtain high sensitivity. In many cases large arrays of detectors will be used, and the associated cooling systems will need performance surpassing the limits of present technologies. NASA is developing a compact cooling system that will lift heat continuously at temperatures below 50 mK and reject it at over 10 K. Based on Adiabatic Demagnetization Refrigerators (ADRs), it will have high thermodynamic efficiency and vibration-free operation with no moving parts. It will provide more than 10 times the current flight ADR cooling power at 50 mK and will also continuously cool a 4 K stage for instruments and optics. In addition, it will include an advanced magnetic shield resulting in external field variations below 5 T. We describe the cooling system here and report on the progress in its development.

space-flight↗