Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

2021 Q1 Project Report: Optimized Bifacial PV Systems (Q1 FY2021 Project Report)

This project has four main technical objectives: 1) Develop and improve bifacial performance models by adding the capability to evaluate electrical behavior and performance of bifacial modules and arrays under realistic field conditions including irradiance variability caused by racking, module frame, and position in the array. 2) Instrument and monitor performance of fielded bifacial systems to validate performance models and to measure, analyze and publish on bifacial energy gain. These should include both research and commercial bifacial systems and cover a variety of deployment applications. 3) Evaluate optimal bifacial system designs using simulations leveraging high-performance computing, and also using full sized and miniaturized experimental field deployments. 4) Establish and contribute to international test standards for bifacial system performance, testing, and safety, and work with the community to establish installation and siting best practices.

42 ENGINEERING↗

Optimal Estimation-Based Algorithm to Retrieve Aerosol Optical Properties for GEMS Measurements Over Asia

The Geostationary Environment Monitoring Spectrometer (GEMS) is scheduled to be in orbit in 2019 onboard the GEO-KOMPSAT 2B satellite and will continuously monitor air quality over Asia. The GEMS will make measurements in the UV spectrum (300-500 nm) with 0.6 nm resolution. In this study, an algorithm is developed to retrieve aerosol optical properties from UV-visible measurements for the future satellite instrument and is tested using 3 years of existing OMI L1B data. This algorithm provides aerosol optical depth (AOD), single scattering albedo (SSA) and aerosol layer height (ALH) using an optimized estimation method. The retrieved AOD shows good correlation with Aerosol Robotic Network (AERONET) AOD with correlation coefficients of 0.83, 0.73 and 0.80 for heavy-absorbing fine (HAF) particles, dust and non-absorbing (NA) particles, respectively. However, regression tests indicate underestimation and overestimation of HAF and NA AOD, respectively. In comparison with AOD from the OMI/Aura Near-UV Aerosol Optical Depth and Single Scattering Albedo 1-orbit L2 Swath 13 km x 24 km V003 (OMAERUV) algorithm, the retrieved AOD has a correlation coefficient of 0.86 and linear regression equation, AOD(sub GEMS) = 1.18AOD(sub OMAERUV) + 0.09. An uncertainty test based on a reference method, which estimates retrieval error by applying the algorithm to simulated radiance data, revealed that assumptions in the spectral dependency of aerosol absorptivity in the UV cause significant errors in aerosol property retrieval, particularly the SSA retrieval. Consequently, retrieved SSAs did not show good correlation with AERONET values. The ALH results were qualitatively compared with the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) products and were found to be well correlated for highly absorbing aerosols. The difference between the attenuated-backscatter-weighted height from CALIOP and retrieved ALH were mostly closed to zero when the retrieved AOD is higher than 0.8 and SSA is lower than 0.93. Although retrieval accuracy was not significantly improved, the simultaneous consistent retrieval of AOD, SSA and ALH alone demonstrates the value of this stand-alone algorithm, given their nature for error using other methods. The use of these properties as input parameters for the air mass factor calculation is expected to improve the retrieval of other trace gases over Asia.

Geostationary Environment Monitoring Spectrometer ↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power (R ~ 100) and a large bandwidth (~ 400 nm – ~ 1.8 µm). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors – fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

An integrated development facility for the calibration of low-energy charged particle flight instrumentation

A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

Biddle, A. P.↗

TMTpro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level

Multiplexed proteomics is a powerful tool to assay cell states in health and disease, but accurate quantification of relative protein changes is impaired by interference from co-isolated peptides. Most widely, this issue is alleviated by MS3-based quantification, reducing sensitivity and requiring specialized instrumentation. An alternative approach is quantification by complementary ions, which allows accurate and precise multiplexed quantification at the MS2 level and is compatible with the most widely distributed instruments. However, complementary ions of the popular TMT tag form inefficiently and plexing is limited to five channels. In this work, we evaluate and optimize complementary ion quantification for the recently released TMTPro tag, which increases plexing capacity to 8 channels (TMTProC). We find that the beneficial fragmentation properties increase quantification signal five-fold compared to TMT. This increased sensitivity results in ~50% more proteins quantified compared to TMTPro-MS3 and even slightly outperforms TMTPro-MS2. Furthermore, TMTProC quantification is more accurate than TMTPro-MS2 and even superior to TMTPro-MS3. To demonstrate the power of TMTProC, we analyzed a human and yeast interference sample and were able to quantify 13,290 proteins in 24 fractions. Thus, TMTProC advances multiplexed proteomics data quality and widens access to accurate multiplexed proteomics beyond laboratories with MS3-capable instrumentation.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a Low-Cost, Sensitivity-Optimized Fluorescence Sensor for Visible Spectrum Analysis

This paper presents an economically viable, sensitivity-optimized fluorescence sensor for detecting low concentrations of fluorophores in the visible spectrum range. The sensor employs a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Instead of utilizing a general-purposed spectrometer optimized for high spectral resolution, the sensor strikes a balance between resolution and sensitivity by using an appropriate aperture size and optimized optical design tailored for the spectral characteristics of fluorophores. Here, the manuscript demonstrates measurements of ppb-level rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions. Through balanced design that optimizes collection of fluorescence emission without losing spectral information, this work shows the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensors with improved detection sensitivity when compared to bench-top commercial spectrofluorometers at far higher costs.

47 OTHER INSTRUMENTATION↗

Physics potential of the IceCube Upgrade for atmospheric neutrino oscillations

The IceCube Upgrade is an extension of the existing IceCube Neutrino Observatory and will be deployed in the 2025–2026 austral summer. It will significantly improve the sensitivity of the detector to atmospheric neutrino oscillations. The existing 86-string IceCube array contains a dense in-fill known as DeepCore which is optimized to measure neutrinos with energies down to a few GeV. The IceCube Upgrade will consist of seven new densely instrumented strings placed within the DeepCore volume to further enhance the performance in the GeV energy range. The additional strings will feature new optical modules, each containing multiple photomultiplier tubes (PMTs), in contrast to the existing modules that each contain a single PMT. This will more than triple the number of PMT channels with respect to the current IceCube configuration, allowing for improved detection efficiency and reconstruction performance at GeV energies. We describe necessary updates to simulation, event selection, and reconstruction to accommodate the higher data rates observed by the upgraded detector and the addition of multi-PMT modules. We determine the expected sensitivity of the IceCube Upgrade to the atmospheric neutrino oscillation parameters sin 2 ⁡𝜃 23 and Δ⁢𝑚$^{2}_{32}$, the appearance of tau neutrinos and the neutrino mass ordering. The IceCube Upgrade will provide neutrino oscillation measurements that are of similar precision to those from accelerator experiments, while providing complementarity by probing higher energies and longer baselines, and with different sources of systematic uncertainties.

artificial neural networks↗

High resolution spectroscopic measurements of carbon dioxide and carbon monoxide

A modified 1.83 meter Jarrell-Ash spectrometer is reported. The instrument was double passed and achieved a resolution of 0.05 cm at 15 micrometers. An integrating voltmeter was used to optimize the available integration time. Data were obtained in the 15 micrometer and 4.3 micrometer band of CO2 and the 4.6 micrometer and 2.3 micrometer bands of CO. The data are summarized and examples of typical spectra are given. All the data are stored on IBM cards.

Chaney, L. W.↗

Development of a method of alignment between various SOLAR MAXIMUM MISSION experiments

Results of an engineering study of the methods of alignment between various experiments for the solar maximum mission are described. The configuration studied consists of the instruments, mounts and instrument support platform located within the experiment module. Hardware design, fabrication methods and alignment techniques were studied with regard to optimizing the coalignment between the experiments and the fine sun sensor. The proposed hardware design was reviewed with regard to loads, stress, thermal distortion, alignment error budgets, fabrication techniques, alignment techniques and producibility. Methods of achieving comparable alignment accuracies on previous projects were also reviewed.

Source record↗

On absorption by hot interstellar gas. II - The 5303-A forbidden line of Fe XIV

Spectroscopic observations of 29 stars at 5303 A obtained with the coude spectrograph on the 2.7-m reflector at McDonald Observatory during 1979-1983 are reported. Instrumental FWHM resolution is 27, 54, or 10 pm, and detection limits near 100 fm equivalent width are obtained in optimal cases. The results are presented in tables and a diagram. No absorption attributable to Fe XIV in hot interstellar gas is detected except for HD 93521, on Apr. 10, 1981, only. This absorption can be located either in interstellar gas at 1.2 million K or less with an Fe XIV/Fe X ratio greater than 3 or in hot gas confined in an inhomogeneous stellar corona.

Hobbs, L. M.↗

An evaluation and force gradient determination of mechanically linked reversible sidestick controllers for General Aviation aircraft

In connection with the increase in air traffic, IFR (Instrument Flight Rules) flight in the air traffic control system has become very demanding. It has, therefore, become imperative to optimize the pilot's skills in his management of the various aircraft systems. The present investigation is concerned with the human factors aspects of the use of sidesticks in direct mechanical linkage (reversible) control systems in a production General Aviation (G.A.) aircraft. A total of 140 fifteen to twenty minute flight tasks were flown on the NASA Langley G.A. motion base simulator. The study involved a comparison of three locations of the sidestick, left side, center, and right side, and the standard yoke. It was found that the sidestick is preferable to the standard yoke. However, some of the design and installation features of the sidestick are critical for pilot acceptance.

Bergeron, H. P.↗

A subscale facility for liquid rocket propulsion diagnostics at Stennis Space Center

The Diagnostics Testbed Facility (DTF) at NASA's John C. Stennis Space Center in Mississippi was designed to provide a testbed for the development of rocket engine exhaust plume diagnostics instrumentation. A 1200-lb thrust liquid oxygen/gaseous hydrogen thruster is used as the plume source for experimentation and instrument development. Theoretical comparative studies have been performed with aerothermodynamic codes to ensure that the DTF thruster (DTFT) has been optimized to produce a plume with pressure and temperature conditions as much like the plume of the Space Shuttle Main Engine as possible. Operation of the DTFT is controlled by an icon-driven software program using a series of soft switches. Data acquisition is performed using the same software program. A number of plume diagnostics experiments have utilized the unique capabilities of the DTF.

Raines, N. G.↗

High-performance packaging for monolithic microwave and millimeter-wave integrated circuits

Packaging schemes were developed that provide low-loss, hermetic enclosure for advanced monolithic microwave and millimeter-wave integrated circuits (MMICs). The package designs are based on a fused quartz substrate material that offers improved radio frequency (RF) performance through 44 gigahertz (GHz). The small size and weight of the packages make them appropriate for a variety of applications, including phased array antenna systems. Packages were designed in two forms; one for housing a single MMIC chip, the second in the form of a multi-chip phased array module. The single chip array module was developed in three separate sizes, for chips of different geometry and frequency requirements. The phased array module was developed to address packaging directly for antenna applications, and includes transmission line and interconnect structures to support multi-element operation. All packages are fabricated using fused quartz substrate materials. As part of the packaging effort, a test fixture was developed to interface the single chip packages to conventional laboratory instrumentation for characterization of the packaged devices. The package and test fixture designs were both developed in a generic sense, optimizing performance for a wide range of possible applications and devices.

Shalkhauser, K. A.↗

Accommodating Heterogeneity in a Debugger for Distributed Computations

In an ongoing project at NASA Ames Research Center, we are building debugger for distributed computations running on a heterogeneous set of machines. Historically, such debuggers have been built as front-ends to existing source-level debuggers on the target platforms. In effect, these back-end debuggers are providing a collection of debugger services to a client. The major drawback is that because of inconsistencies among the back-end debuggers, the front-end must use a different protocol when talking to each back-end debugger. This can make the front-end quite complex. We have avoided this complexity problem by defining the client-server debugger protocol. While it does require vendors to adapt their existing debugger code to meet the protocol, vendors are generally interested in doing so because the approach has several advantages. In addition to solving the heterogenous platform debugging problem, it will be pos~sible to write interesting debugger user interfaces that can be easily ported across a variety of machines. This will likely encourage investment in application-domain specific debuggers. In fact, the user interface of our debugger will be geared to scientists developing computational fluid dynamics codes. This paper describes some of the problems encountered in developing a portable debugger for heterogenous, distributed computing and how the architecture of our debugger avoids them. It then provides a detailed description of the debugger client-server protocol. Some of the more interesting attributes of the protocol are: (1) It is object-oriented; (2) It uses callback functions to capture the asynchronous nature of debugging in a procedural fashion; (3) It contains abstractions, such as in-line instrumentation, for the debugging of computationally intensive programs; (4) For remote debugging, it has operations that enable the implementor to optimize message passing traffic between client and server. The soundness of the protocol is being tested through the implementation of a prototype client and server pair.

Hood, Robert↗

Hayabusa Re-Entry: Trajectory Analysis and Observation Mission Design

On June 13th, 2010, the Hayabusa sample return capsule successfully re-entered Earth s atmosphere over the Woomera Prohibited Area in southern Australia in its quest to return fragments from the asteroid 1998 SF36 Itokawa . The sample return capsule entered at a super-orbital velocity of 12.04 km/sec (inertial), making it the second fastest human-made object to traverse the atmosphere. The NASA DC-8 airborne observatory was utilized as an instrument platform to record the luminous portion of the sample return capsule re-entry (~60 sec) with a variety of on-board spectroscopic imaging instruments. The predicted sample return capsule s entry state information at ~200 km altitude was propagated through the atmosphere to generate aerothermodynamic and trajectory data used for initial observation flight path design and planning. The DC- 8 flight path was designed by considering safety, optimal sample return capsule viewing geometry and aircraft capabilities in concert with key aerothermodynamic events along the predicted trajectory. Subsequent entry state vector updates provided by the Deep Space Network team at NASA s Jet Propulsion Laboratory were analyzed after the planned trajectory correction maneuvers to further refine the DC-8 observation flight path. Primary and alternate observation flight paths were generated during the mission planning phase which required coordination with Australian authorities for pre-mission approval. The final observation flight path was chosen based upon trade-offs between optimal viewing requirements, ground based observer locations (to facilitate post-flight trajectory reconstruction), predicted weather in the Woomera Prohibited Area and constraints imposed by flight path filing deadlines. To facilitate sample return capsule tracking by the instrument operators, a series of two racetrack flight path patterns were performed prior to the observation leg so the instruments could be pointed towards the region in the star background where the sample return capsule was expected to become visible. An overview of the design methodologies and trade-offs used in the Hayabusa re-entry observation campaign are presented.

Cassell, Alan M.↗

Post Launch Calibration and Testing of the Geostationary Lightning Mapper on the GOES-R Satellite

The Geostationary Operational Environmental Satellite R (GOES-R) series is the planned next generation of operational weather satellites for the United States National Oceanic and Atmospheric Administration (NOAA). The National Aeronautics and Space Administration (NASA) is procuring the GOES-R spacecraft and instruments with the first launch of the GOES-R series planned for October 2016. Included in the GOES-R Instrument suite is the Geostationary Lightning Mapper (GLM). GLM is a single-channel, near-infrared optical detector that can sense extremely brief (800 microseconds) transient changes in the atmosphere, indicating the presence of lightning. GLM will measure total lightning activity continuously over the Americas and adjacent ocean regions with near-uniform spatial resolution of approximately 10 km. Due to its large CCD (1372x1300 pixels), high frame rate, sensitivity and onboard event filtering, GLM will require extensive post launch characterization and calibration. Daytime and nighttime images will be used to characterize both image quality criteria inherent to GLM as a space-based optic system (focus, stray light, crosstalk, solar glint) and programmable image processing criteria (dark offsets, gain, noise, linearity, dynamic range). In addition ground data filtering will be adjusted based on lightning-specific phenomenology (coherence) to isolate real from false transients with their own characteristics. These parameters will be updated, as needed, on orbit in an iterative process guided by pre-launch testing. This paper discusses the planned tests to be performed on GLM over the six-month Post Launch Test period to optimize and demonstrate GLM performance.

validation↗

Micro-Spec: An Ultra-Compact, High-Sensitivity Spectrometer for Far-Infrared and Sub-Millimeter Astronomy

High-performance, integrated spectrometers operating in the far-infrared and sub-millimeter promise to be powerful tools for the exploration of the epochs of reionization and initial galaxy formation. These devices, using high-efficiency superconducting transmission lines, can achieve the performance of a meter-scale grating spectrometer in an instrument implemented on a four-inch silicon wafer. Such a device, when combined with a cryogenic telescope in space, provides an enabling capability for studies of the early universe. Here, the optical design process for Micro-Spec (mu-Spec) is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the stigmatization and minimization of the light path function in this bounded region, which results in an optimized geometrical configuration. A point design with an efficiency of approx. 90% has been developed for initial demonstration, and can serve as the basis for future instruments. Design variations on this implementation are also discussed, which can lead to lower efficiencies due to diffractive losses in the multimode region.

spectroscopic instrumentation↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization NPIC presentation

The nuclear industry is beginning to see reactors shut down—even after their operating licenses have been extended—because they are not economically competitive with other energy sources. These early closures happen primarily due to economic reasons, despite excellent safety records. Therefore, it is imperative to reduce costs in order to prevent these early closures. One of the contributors to these economic reasons is the large operations and maintenance costs. This paper showcases recent research on advanced fault diagnostics techniques and preventative maintenance optimization (PMO) for reducing NPP maintenance costs. Specifically, it focuses on the feedwater and condensate system (FWCS) for both pressurized- and boiling-water reactor (BWR) systems. The computerized maintenance management system (CMMS), which contains the plant’s digital record of all corrective maintenance (CM) and preventative maintenance (PM) work orders, provided the ground truth for locating potential faults and labeling the process data as either healthy or faulted. Various feature extraction techniques were used to further differentiate the faulted data from the healthy data. Through a cross-validation procedure, support vectors machines were used to label other test sets of process data as either healthy or faulted. With relatively few faults identified in the BWR system, the potential for PMO opens up, since an unnecessary amount of PM leads to inflated maintenance costs. The steps for PMO are summarized, from component health determinations to recommendations for action. An example of PMO assessment is presented for condensate pumps, condensate booster pumps, and the respective motors that drive them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗