Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

TH-A-18C-10: Dynamic Intensity Weighted Region of Interest Imaging

Purpose: For image guidance tasks full image quality is not required throughout the entire image. With dynamic filtration of the kV imaging beam the noise properties of the CT image can be locally controlled, providing a high quality image around the target volume with a lower quality surrounding region while providing substantial dose sparing to the patient as well as reduced scatter fluence on the detector. Methods: A dynamic collimation device with 3mm copper blades has been designed to mount in place of the bowtie filter on the On-Board Imager (Varian Medical Systems). The beam intensity is reduced by 95% behind the copper filters and the aperture is controlled dynamically to conformally illuminate a given ROI during a standard cone-beam CT scan. A data correction framework to account for the physical effects of the collimator prior to reconstruction was developed. Furthermore, to determine the dose savings and scatter reduction a monte carlo model was built in BEAMnrc with specifics from the Varian Monte Carlo Data Package. The MC model was validated with Gafchromic film. Results: The reconstructed image shows image quality comparable to a standard scan in the specified ROI, with higher noise and streaks in the outer region but still sufficient information for alignment to high contrast structures. The monte carlo modeling showed that the scatter-to-primary ratio was reduced from 1.26 for an unfiltered scan to 0.45 for an intensity weighted scan, suggesting that image quality may be improved in the inner ROI. Dose in the inner region was reduced 10–15% due to reduced scatter and by as much as 75% in the outer region. Conclusion: Dynamic intensity-weighted ROI imaging allows reduction of imaging dose to sensitive organs away from the target region while providing images that retain their utility for patient setup and procedure guidance. Funding was provided in part by Varian Medical Systems and NIH Grants 1RO1CA120540, T32EB002103, S10 RR021039 and P30 CA14599. The contents of this work are solely the responsibility of the authors and do not necessarily represent the official views of any of the supporting organizations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-207-03: Optimization of a Collimator-Based Sparse Sampling Technique for Low-Dose Cone-Beam CT

Purpose: In computed tomography (CT) imaging, radiation dose delivered to the patient is one of the major concerns. Sparse-view CT takes projections at sparser view angles and provides a viable option to reducing dose. However, a fast power switching of an X-ray tube, which is needed for the sparse-view sampling, can be challenging in many CT systems. We have earlier proposed a many-view under-sampling (MVUS) technique as an alternative to sparse-view CT. In this study, we investigated the effects of collimator parameters on the image quality and aimed to optimize the collimator design. Methods: We used a bench-top circular cone-beam CT system together with a CatPhan600 phantom, and took 1440 projections from a single rotation. The multi-slit collimator made of tungsten was mounted on the X-ray source for beam blocking. For image reconstruction, we used a total-variation minimization (TV) algorithm and modified the backprojection step so that only the measured data through the collimator slits are to be used in the computation. The number of slits and the reciprocation frequency have been varied and the effects of them on the image quality were investigated. We also analyzed the sampling efficiency: the sampling density and data incoherence in each case. We tested three sets of slits with their number of 6, 12 and 18, each at reciprocation frequencies of 10, 30, 50 and 70 Hz/ro. Results: Consistent results in the image quality have been produced with the sampling efficiency, and the optimum condition was found to be using 12 slits at 30 Hz/ro. As image quality indices, we used the CNR and the detectability. Conclusion: We conducted an experiment with a moving multi-slit collimator to realize a sparse-sampled cone-beam CT. Effects of collimator parameters on the image quality have been systematically investigated, and the optimum condition has been reached.

60 APPLIED LIFE SCIENCES↗

Modulation-transfer-function analysis for sampled image systems

Sampling generally causes the response of a digital imaging system to be locally shift-variant and not directly amenable to Modulation Transfer Function (MTF) analysis. However, this paper demonstrates that a meaningful system response can be calculated by averaging over an ensemble of point-source system inputs to yield an MTF which accounts for the combined effects of image formation, sampling, and image reconstruction. As an illustration, the MTF of the Landsat MSS system is analyzed to reveal an average effective instantaneous field of view which is significantly larger than the commonly accepted value, particularly in the along-track direction where undersampling contributes markedly to an MTF reduction and resultant increase in image blur.

Park, S. K.↗

Bragg coherent diffraction imaging by simultaneous reconstruction of multiple diffraction peaks

Bragg coherent diffractive imaging (BCDI) is a non-invasive microscopy technique that can visualize the morphology and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. While BCDI has been successfully applied in various studies of materials, it is less successful for highly-strained crystals. Specifically, it is difficult to correctly reconstruct the electron density of a highly-strained object using conventional phase retrieval algorithms. Although various algorithms have been developed to overcome this challenge, most of them require a priori knowledge that is not always available in practice. Here we report on a new phase retrieval workflow that can invert diffraction patterns from multiple Bragg peaks simultaneously. The new workflow is explored via simulated diffraction from crystals with various strain conditions. Furthermore, reconstructions from the new workflow consistently demonstrate more accurate electron density maps, in comparison with the conventional method. For highly-strained crystals, the new workflow improves the reliability and consistency of BCDI phase retrieval significantly.

36 MATERIALS SCIENCE↗

Nanoscale chemical imaging with structured X-ray illumination

High-resolution imaging with compositional and chemical sensitivity is crucial for a wide range of scientific and engineering disciplines. Although synchrotron X-ray imaging through spectromicroscopy has been tremendously successful and broadly applied, it encounters challenges in achieving enhanced detection sensitivity, satisfactory spatial resolution, and high experimental throughput simultaneously. In this work, based on structured illumination, we develop a single-pixel X-ray imaging approach coupled with a generative image reconstruction model for mapping the compositional heterogeneity with nanoscale resolvability. This method integrates a full-field transmission X-ray microscope with an X-ray fluorescence detector and eliminates the need for nanoscale X-ray focusing and raster scanning. We experimentally demonstrate the effectiveness of our approach by imaging a battery sample composed of mixed cathode materials and successfully retrieving the compositional variations of the imaged cathode particles. Bridging the gap between structural and chemical characterizations using X-rays, this technique opens up vast opportunities in the fields of biology, environmental, and materials science, especially for radiation-sensitive samples.

Li, Jizhou↗

Measuring interfraction and intrafraction lung function changes during radiation therapy using four-dimensional cone beam CT ventilation imaging

Purpose: Adaptive ventilation guided radiation therapy could minimize the irradiation of healthy lung based on repeat lung ventilation imaging (VI) during treatment. However the efficacy of adaptive ventilation guidance requires that interfraction (e.g., week-to-week), ventilation changes are not washed out by intrafraction (e.g., pre- and postfraction) changes, for example, due to patient breathing variability. The authors hypothesize that patients undergoing lung cancer radiation therapy exhibit larger interfraction ventilation changes compared to intrafraction function changes. To test this, the authors perform the first comparison of interfraction and intrafraction lung VI pairs using four-dimensional cone beam CT ventilation imaging (4D-CBCT VI), a novel technique for functional lung imaging. Methods: The authors analyzed a total of 215 4D-CBCT scans acquired for 19 locally advanced non-small cell lung cancer (LA-NSCLC) patients over 4–6 weeks of radiation therapy. This set of 215 scans was sorted into 56 interfraction pairs (including first day scans and each of treatment weeks 2, 4, and 6) and 78 intrafraction pairs (including pre/postfraction scans on the same-day), with some scans appearing in both sets. VIs were obtained from the Jacobian determinant of the transform between the 4D-CBCT end-exhale and end-inhale images after deformable image registration. All VIs were deformably registered to their corresponding planning CT and normalized to account for differences in breathing effort, thus facilitating image comparison in terms of (i) voxelwise Spearman correlations, (ii) mean image differences, and (iii) gamma pass rates for all interfraction and intrafraction VI pairs. For the side of the lung ipsilateral to the tumor, we applied two-sided t-tests to determine whether interfraction VI pairs were more different than intrafraction VI pairs. Results: The (mean ± standard deviation) Spearman correlation for interfraction VI pairs was r{sup -}{sub Inter}=0.52±0.25, which was significantly lower than for intrafraction pairs (r{sup -}{sub Intra}=0.67±0.20, p = 0.0002). Conversely, mean absolute ventilation differences were larger for interfraction pairs than for intrafraction pairs, with |ΔV{sup -}{sub Inter}|=0.42±0.65 and |ΔV{sup -}{sub Intra}|=0.32±0.53, respectively (p < 10{sup −15}). Applying a gamma analysis with ventilation/distance tolerance of 25%/10 mm, we observed mean pass rate of (69% ± 20%) for interfraction VIs, which was significantly lower compared to intrafraction pairs (80% ± 15%, with p ∼ 0.0003). Compared to the first day scans, all patients experienced at least one subsequent change in median ipsilateral ventilation ≥10%. Patients experienced both positive and negative ventilation changes throughout treatment, with the maximum change occurring at different weeks for different patients. Conclusions: The authors’ data support the hypothesis that interfraction ventilation changes are larger than intrafraction ventilation changes for LA-NSCLC patients over a course of conventional lung cancer radiation therapy. Longitudinal ventilation changes are observed to be highly patient-dependent, supporting a possible role for adaptive ventilation guidance based on repeat 4D-CBCT VIs. We anticipate that future improvement of 4D-CBCT image reconstruction algorithms will improve the capability of 4D-CBCT VI to resolve interfraction ventilation changes.

60 APPLIED LIFE SCIENCES↗

Control of image reproducibilty in a response of a stimulated echo hologram

We consider image recording and reproduction using a reversed stimulated echo hologram, with a recording medium exposed to pulses of nonresonant electromagnetic standing waves. It is shown that the spatial intensity distribution in a stimulated echo hologram response depends on the electric field strength of nonresonant standing waves, which makes it possible to control reconstructed images. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Angular oversampling with temporally offset layers on multilayer detectors in computed tomography

Purpose: Today’s computed tomography (CT) scanners operate at an increasingly high rotation speed in order to reduce motion artifacts and to fulfill the requirements of dynamic acquisition, e.g., perfusion and cardiac imaging, with lower angular sampling rate as a consequence. In this paper, a simple method for obtaining angular oversampling when using multilayer detectors in continuous rotation CT is presented. Methods: By introducing temporal offsets between the measurement periods of the different layers on a multilayer detector, the angular sampling rate can be increased by a factor equal to the number of layers on the detector. The increased angular sampling rate reduces the risk of producing aliasing artifacts in the image. A simulation of a detector with two layers is performed to prove the concept. Results: The simulation study shows that aliasing artifacts from insufficient angular sampling are reduced by the proposed method. Specifically, when imaging a single point blurred by a 2D Gaussian kernel, the method is shown to reduce the strength of the aliasing artifacts by approximately an order of magnitude. Conclusions: The presented oversampling method is easy to implement in today’s multilayer detectors and has the potential to reduce aliasing artifacts in the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Parallel Information Processing (Image Transmission Via Fiber Bundle and Multimode Fiber

Growing demand for visual, user-friendly representation of information inspires search for the new methods of image transmission. Currently used in-series (sequential) methods of information processing are inherently slow and are designed mainly for transmission of one or two dimensional arrays of data. Conventional transmission of data by fibers requires many fibers with array of laser diodes and photodetectors. In practice, fiber bundles are also used for transmission of images. Image is formed on the fiber-optic bundle entrance surface and each fiber transmits the incident image to the exit surface. Since the fibers do not preserve phase, only 2D intensity distribution can be transmitted in this way. Each single mode fiber transmit only one pixel of an image. Multimode fibers may be also used, so that each mode represent different pixel element. Direct transmission of image through multimode fiber is hindered by the mode scrambling and phase randomization. To overcome these obstacles wavelength and time-division multiplexing have been used, with each pixel transmitted on a separate wavelength or time interval. Phase-conjugate techniques also was tested in, but only in the unpractical scheme when reconstructed image return back to the fiber input end. Another method of three-dimensional imaging over single mode fibers was demonstrated in, using laser light of reduced spatial coherence. Coherence encoding, needed for a transmission of images by this methods, was realized with grating interferometer or with the help of an acousto-optic deflector. We suggest simple practical holographic method of image transmission over single multimode fiber or over fiber bundle with coherent light using filtering by holographic optical elements. Originally this method was successfully tested for the single multimode fiber. In this research we have modified holographic method for transmission of laser illuminated images over commercially available fiber bundle (fiber endoscope, or fiberscope).

Kukhtarev, Nicholai↗

Study on the ultrasonic inspection method using the full matrix capture for the in service railway wheel

The quality of wheel is especially important for the safety of high speed railway. In this paper, a new ultrasonic array inspection method, the Full Matrix Capture (FMC) has been studied and applied to the high speed railway wheel inspection, especially in the wheel web from the tread. Firstly, the principle of FMC and TFM algorithm is discussed, and then the new optimization is applied to the standard FMC; Secondly the fundamentals of optimization is described in detail and the performance is analyzed. Finally, the experiment has been built with a standard phased array block and railway wheel, and then the testing results are discussed and analyzed. It is demonstrated that this change for the ultrasonic data acquisition and image reconstruction has higher efficiency and lower cost comparing to the FMC's procedure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction

Coherent x-ray diffraction microscopy is a lensless phase-contrast imaging technique with high image contrast. Although electron tomography allows intensive study of the three-dimensional structure of cellular organelles, it has inherent difficulty with thick objects. X rays have the unique benefit of allowing noninvasive analysis of thicker objects and high spatial resolution. We observed an unstained human chromosome using coherent x-ray diffraction. The reconstructed images in two or three dimensions show an axial structure, which has not been observed under unstained conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-FG-BRB-03: Basis Vector Model Based Method for Proton Stopping Power Estimation From Experimental Dual Energy CT Data

Purpose: This work aims at reducing the uncertainty in proton stopping power (SP) estimation by a novel combination of a linear, separable basis vector model (BVM) for stopping power calculation (Med Phys 43:600) and a statistical, model-based dual-energy CT (DECT) image reconstruction algorithm (TMI 35:685). The method was applied to experimental data. Methods: BVM assumes the photon attenuation coefficients, electron densities, and mean excitation energies (I-values) of unknown materials can be approximated by a combination of the corresponding quantities of two reference materials. The DECT projection data for a phantom with 5 different known materials was collected on a Philips Brilliance scanner using two scans at 90 kVp and 140 kVp. The line integral alternating minimization (LIAM) algorithm was used to recover the two BVM coefficient images using the measured source spectra. The proton stopping powers are then estimated from the Bethe-Bloch equation using electron densities and I-values derived from the BVM coefficients. The proton stopping powers and proton ranges for the phantom materials estimated via our BVM based DECT method are compared to ICRU reference values and a post-processing DECT analysis (Yang PMB 55:1343) applied to vendorreconstructed images using the Torikoshi parametric fit model (tPFM). Results: For the phantom materials, the average stopping power estimations for 175 MeV protons derived from our method are within 1% of the ICRU reference values (except for Teflon with a 1.48% error), with an average standard deviation of 0.46% over pixels. The resultant proton ranges agree with the reference values within 2 mm. Conclusion: Our principled DECT iterative reconstruction algorithm, incorporating optimal beam hardening and scatter corrections, in conjunction with a simple linear BVM model, achieves more accurate and robust proton stopping power maps than the post-processing, nonlinear tPFM based DECT analysis applied to conventional reconstructions of low and high energy scans. Funding Support: NIH R01CA 75371; NCI grant R01 CA 149305.

60 APPLIED LIFE SCIENCES↗

System and technique for retrieving depth information about a surface by projecting a composite image of modulated light patterns

A technique, associated system and program code, for retrieving depth information about at least one surface of an object. Core features include: projecting a composite image comprising a plurality of modulated structured light patterns, at the object; capturing an image reflected from the surface; and recovering pattern information from the reflected image, for each of the modulated structured light patterns. Pattern information is preferably recovered for each modulated structured light pattern used to create the composite, by performing a demodulation of the reflected image. Reconstruction of the surface can be accomplished by using depth information from the recovered patterns to produce a depth map/mapping thereof. Each signal waveform used for the modulation of a respective structured light pattern, is distinct from each of the other signal waveforms used for the modulation of other structured light patterns of a composite image; these signal waveforms may be selected from suitable types in any combination of distinct signal waveforms, provided the waveforms used are uncorrelated with respect to each other. The depth map/mapping to be utilized in a host of applications, for example: displaying a 3-D view of the object; virtual reality user-interaction interface with a computerized device; face--or other animal feature or inanimate object--recognition and comparison techniques for security or identification purposes; and 3-D video teleconferencing/telecollaboration.

Hassebrook, Laurence G.↗

System and technique for retrieving depth information about a surface by projecting a composite image of modulated light patterns

A technique, associated system and program code, for retrieving depth information about at least one surface of an object, such as an anatomical feature. Core features include: projecting a composite image comprising a plurality of modulated structured light patterns, at the anatomical feature; capturing an image reflected from the surface; and recovering pattern information from the reflected image, for each of the modulated structured light patterns. Pattern information is preferably recovered for each modulated structured light pattern used to create the composite, by performing a demodulation of the reflected image. Reconstruction of the surface can be accomplished by using depth information from the recovered patterns to produce a depth map/mapping thereof. Each signal waveform used for the modulation of a respective structured light pattern, is distinct from each of the other signal waveforms used for the modulation of other structured light patterns of a composite image; these signal waveforms may be selected from suitable types in any combination of distinct signal waveforms, provided the waveforms used are uncorrelated with respect to each other. The depth map/mapping to be utilized in a host of applications, for example: displaying a 3-D view of the object; virtual reality user-interaction interface with a computerized device; face--or other animal feature or inanimate object--recognition and comparison techniques for security or identification purposes; and 3-D video teleconferencing/telecollaboration.

Hassebrook, Laurence G.↗

Development and evaluation of a Hadamard transform imaging spectrometer and a Hadamard transform thermal imager

A spectrometric imager and a thermal imager, which achieve multiplexing by the use of binary optical encoding masks, were developed. The masks are based on orthogonal, pseudorandom digital codes derived from Hadamard matrices. Spatial and/or spectral data is obtained in the form of a Hadamard transform of the spatial and/or spectral scene; computer algorithms are then used to decode the data and reconstruct images of the original scene. The hardware, algorithms and processing/display facility are described. A number of spatial and spatial/spectral images are presented. The achievement of a signal-to-noise improvement due to the signal multiplexing was also demonstrated. An analysis of the results indicates both the situations for which the multiplex advantage may be gained, and the limitations of the technique. A number of potential applications of the spectrometric imager are discussed.

Harwit, M.↗

Image quality measures and their performance

A number of quality measures are evaluated for gray scale image compression. They are all bivariate exploiting the differences between corresponding pixels in the original and degraded images. It is shown that although some numerical measures correlate well with the observers' response for a given compression technique, they are not reliable for an evaluation across different techniques. The two graphical measures (histograms and Hosaka plots), however, can be used to appropriately specify not only the amount, but also the type of degradation in reconstructed images.

Eskicioglu, Ahmet M.↗

A low dose simulation tool for CT systems with energy integrating detectors

Purpose: This paper introduces a new strategy for simulating low-dose computed tomography (CT) scans using real scans of a higher dose as an input. The tool is verified against simulations and real scans and compared to other approaches found in the literature. Methods: The conditional variance identity is used to properly account for the variance of the input high-dose data, and a formula is derived for generating a new Poisson noise realization which has the same mean and variance as the true low-dose data. The authors also derive a formula for the inclusion of real samples of detector noise, properly scaled according to the level of the simulated x-ray signals. Results: The proposed method is shown to match real scans in number of experiments. Noise standard deviation measurements in simulated low-dose reconstructions of a 35 cm water phantom match real scans in a range from 500 to 10 mA with less than 5% error. Mean and variance of individual detector channels are shown to match closely across the detector array. Finally, the visual appearance of noise and streak artifacts is shown to match in real scans even under conditions of photon-starvation (with tube currents as low as 10 and 80 mA). Additionally, the proposed method is shown to be more accurate than previous approaches (1) in achieving the correct mean and variance in reconstructed images from pure-Poisson noise simulations (with no detector noise) under photon-starvation conditions, and (2) in simulating the correct noise level and detector noise artifacts in real low-dose scans. Conclusions: The proposed method can accurately simulate low-dose CT data starting from high-dose data, including effects from photon starvation and detector noise. This is potentially a very useful tool in helping to determine minimum dose requirements for a wide range of clinical protocols and advanced reconstruction algorithms.

60 APPLIED LIFE SCIENCES↗

Optimising the processing and storage of visibilities using lossy compression

The next-generation radio astronomy instruments are providing a massive increase in sensitivity and coverage, largely through increasing the number of stations in the array and the frequency span sampled. The two primary problems encountered when processing the resultant avalanche of data are the need for abundant storage and the constraints imposed by I/O, as I/O bandwidths drop significantly on cold storage. An example of this is the data deluge expected from the SKA Telescopes of more than 60 PB per day, all to be stored on the buffer filesystem. While compressing the data is an obvious solution, the impacts on the final data products are hard to predict. In this paper, we chose an error-controlled compressor – MGARD – and applied it to simulated SKA-Mid and real pathfinder visibility data, in noise-free and noise-dominated regimes. As the data have an implicit error level in the system temperature, using an error bound in compression provides a natural metric for compression. MGARD ensures the compression incurred errors adhere to the user-prescribed tolerance. To measure the degradation of images reconstructed using the lossy compressed data, we proposed a list of diagnostic measures, exploring the trade-off between these error bounds and the corresponding compression ratios, as well as the impact on science quality derived from the lossy compressed data products through a series of experiments. We studied the global and local impacts on the output images for continuum and spectral line examples. We found relative error bounds of as much as 10%, which provide compression ratios of about 20, have a limited impact on the continuum imaging as the increased noise is less than the image RMS, whereas a 1% error bound (compression ratio of 8) introduces an increase in noise of about an order of magnitude less than the image RMS. For extremely sensitive observations and for very precious data, we would recommend a 0.1% error bound with compression ratios of about 4. These have noise impacts two orders of magnitude less than the image RMS levels. At these levels, the limits are due to instabilities in the deconvolution methods. We compared the results to the alternative compression tool DYSCO, in both the impacts on the images and in the relative flexibility. MGARD provides better compression for similar error bounds and has a host of potentially powerful additional features.

Techniques: interferometric↗