Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Human Performance Improvement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Architectural study of the design and operation of advanced force feedback manual controllers

A teleoperator system consists of a manual controller, control hardware/software, and a remote manipulator. It was employed in either hazardous or unstructured, and/or remote environments. In teleoperation, the main-in-the-loop is the central concept that brings human intelligence to the teleoperator system. When teleoperation involves contact with an uncertain environment, providing the feeling of telepresence to the human operator is one of desired characteristics of the teleoperator system. Unfortunately, most available manual controllers in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size, high costs, or lack of smoothness and transparency, and elementary architectures. To investigate other alternatives, a force-reflecting, 3 degree of freedom (dof) spherical manual controller is designed, analyzed, and implemented as a test bed demonstration in this research effort. To achieve an improved level of design to meet criteria such as compactness, portability, and a somewhat enhanced force-reflecting capability, the demonstration manual controller employs high gear-ratio reducers. To reduce the effects of the inertia and friction on the system, various force control strategies are applied and their performance investigated. The spherical manual controller uses a parallel geometry to minimize inertial and gravitational effects on its primary task of transparent information transfer. As an alternative to the spherical 3-dof manual controller, a new conceptual (or parallel) spherical 3-dof module is introduced with a full kinematic analysis. Also, the resulting kinematic properties are compared to those of other typical spherical 3-dof systems. The conceptual design of a parallel 6-dof manual controller and its kinematic analysis is presented. This 6-dof manual controller is similar to the Stewart Platform with the actuators located on the base to minimize the dynamic effects. Finally, a combination of the new 3-dof and 6-dof concepts is presented as a feasible test-bed for enhanced performance in a 9-dof system.

Tesar, Delbert↗

Overview of the Smart Network Element Architecture and Recent Innovations

In industrial environments, system operators rely on the availability and accuracy of sensors to monitor processes and detect failures of components and/or processes. The sensors must be networked in such a way that their data is reported to a central human interface, where operators are tasked with making real-time decisions based on the state of the sensors and the components that are being monitored. Incorporating health management functions at this central location aids the operator by automating the decision-making process to suggest, and sometimes perform, the action required by current operating conditions. Integrated Systems Health Management (ISHM) aims to incorporate data from many sources, including real-time and historical data and user input, and extract information and knowledge from that data to diagnose failures and predict future failures of the system. By distributing health management processing to lower levels of the architecture, there is less bandwidth required for ISHM, enhanced data fusion, make systems and processes more robust, and improved resolution for the detection and isolation of failures in a system, subsystem, component, or process. The Smart Network Element (SNE) has been developed at NASA Kennedy Space Center to perform intelligent functions at sensors and actuators' level in support of ISHM.

Perotti, Jose M.↗

Robot hands and extravehicular activity

Extravehicular activity (EVA) is crucial to the success of both current and future space operations. As space operations have evolved in complexity so has the demand placed on the EVA crewman. In addition, some NASA requirements for human capabilities at remote or hazardous sites were identified. One of the keys to performing useful EVA tasks is the ability to manipulate objects accurately, quickly and without early or excessive fatigue. The current suit employs a glove which enables the crewman to perform grasping tasks, use tools, turn switches, and perform other tasks for short periods of time. However, the glove's bulk and resistance to motion ultimately causes fatigue. Due to this limitation it may not be possible to meet the productivity requirements that will be placed on the EVA crewman of the future with the current or developmental Extravehicular Mobility Unit (EMU) hardware. In addition, this hardware will not meet the requirements for remote or hazardous operations. In an effort to develop ways for improving crew productivity, a contract was awarded to develop a prototype anthromorphic robotic hand (ARH) for use with an extravehicular space suit. The first step in this program was to perform a a design study which investigated the basic technology required for the development of an ARH to enhance crew performance and productivity. The design study phase of the contract and some additional development work is summarized.

Marcus, Beth↗

SIBatt-3D: In-Space/On-Surface 3D Printing of Sodium Ion Batteries from ISRU Materials

Constructed more than 20 years ago, the International Space Station’s primary power system originally used nickel-hydrogen batteries with a lifetime of 6.5 years, until NASA began the process of replacing them in 2016 with lithium-ion batteries with a lifetime of 10 years. The demanding and costly process was accomplished after four flights of the Japanese H-II Transfer Vehicle cargo spacecraft (with a cost of about $10,000 per pound of payload), and 13 different astronauts conducting 14 spacewalks. Besides utilization in the ISS, rechargeable batteries are present in many space applications: they are installed in exploration robots, life support systems and in portable communication devices, to mention some. In this context, this project is focused on the in-space manufacturing of shape-conformable batteries using in-situ resources, and aims to address the NASA’s gaps related to the development of next generation of energy storage devices (TX03), as well as in-space manufacturing and in-situ resource utilization (TX07). The proposed work also tackles the HEOMD’s objectives targeting the in-space additive manufacturing (AM) from Lunar/Martian materials (regolith as AM feedstock) to reinvigorate America’s Human Space Exploration Program (SPD-1). This project is in direct alignment with the STMD’s objectives to demonstrate in-space autonomous manufacturing and assembly of complete systems by 2030, and to enable humans to live and explore in space and on planetary surfaces by 2040 thanks to in-space habitation, infrastructure development and in-situ resource utilization (ST1 and ST5). Manufacturing of shape conformable batteries directly in-space and using in-situ resources would also contribute to reducing the payload weight and volume (TX12) for future missions, thus reducing risk for long term Mars missions where rapid resupply is logistically infeasible. Nowadays, commercial batteries consist of stacked two-dimensional (2D) sheets, which are only manufactured in restricted geometries (cylindrical and coin cell). Evolving from conventional 2D, complex 3D battery architectures have been proven to increase the electrochemical active surface area and ion diffusion path, leading to improved areal energy density and power performance. This tendency was illustrated in our recent in-depth modeling studies by simulating a classical Ragone plot exhibiting the energy-power relationship. Our team demonstrated through modeling that a complex gyroidal 3D printed battery architecture exhibits significantly improved power performances (>150% at the current density of 6C; full discharge in 10 minutes) in comparison to a traditional 3D printed planar geometry. Motivated by these results and as the fabrication of intricate 3D battery design is only possible experimentally thanks to the geometric freedom offered by additive manufacturing (AM), our team has already initiated leveraging thermoplastic material extrusion at the laboratory scale. While 3D printing of batteries is relatively recent (2013), it has witnessed a growing interest during the last recent years, as next-generation shape-conformable 3D batteries can be co-designed with the system. Consequently, dead-volume and mass brought from Earth are minimized, in addition to improved battery performance, in alignment with the aforementioned NASA’s objectives. Further, while this project is specifically dedicated to batteries, it lends itself towards the maturation of in-space manufacturing via 3D printing using in-situ resources, stated in HEOMD and STMD goals.

In-Space Manufacturing↗

Sensorimotor recovery following spaceflight may be due to frequent square-wave saccadic intrusions

Square-wave jerks (SWJs) are small, involuntary saccades that disrupt steady fixation. We report the case of an astronaut (approximately 140 d on orbit) who showed frequent SWJs, especially postflight, but who showed no impairment of vision or decrement of postflight performance. These data support the view that SWJs do not impair vision because they are paired movements, consisting of a small saccade away from the fixation position followed, within 200 ms, by a corrective saccade that brings the eye back on target. Since many returning astronauts show a decrement of dynamic visual function during postflight locomotion, it seems possible that frequent SWJs improved this astronaut's visual function by providing postsaccadic enhancement of visual fixation, which aided postflight performance. Certainly, frequent SWJs did not impair performance in this astronaut, who had no other neurological disorder.

Case Reports↗

Learning from Automation Surprises and "Going Sour" Accidents: Progress on Human-Centered Automation

Advances in technology and new levels of automation on commercial jet transports has had many effects. There have been positive effects from both an economic and a safety point of view. The technology changes on the flight deck also have had reverberating effects on many other aspects of the aviation system and different aspects of human performance. Operational experience, research investigations, incidents, and occasionally accidents have shown that new and sometimes surprising problems have arisen as well. What are these problems with cockpit automation, and what should we learn from them? Do they represent over-automation or human error? Or instead perhaps there is a third possibility - they represent coordination breakdowns between operators and the automation? Are the problems just a series of small independent glitches revealed by specific accidents or near misses? Do these glitches represent a few small areas where there are cracks to be patched in what is otherwise a record of outstanding designs and systems? Or do these problems provide us with evidence about deeper factors that we need to address if we are to maintain and improve aviation safety in a changing world? How do the reverberations of technology change on the flight deck provide insight into generic issues about developing human-centered technologies and systems (Winograd and Woods, 1997)? Based on a series of investigations of pilot interaction with cockpit automation (Sarter and Woods, 1992; 1994; 1995; 1997a, 1997 b), supplemented by surveys, operational experience and incident data from other studies (e.g., Degani et al., 1995; Eldredge et al., 1991; Tenney et al., 1995; Wiener, 1989), we too have found that the problems that surround crew interaction with automation are more than a series of individual glitches. These difficulties are symptoms that indicate deeper patterns and phenomena concerning human-machine cooperation and paths towards disaster. In addition, we find the same kinds of patterns behind results from studies of physician interaction with computer-based systems in critical care medicine (e.g., Moll van Charante et al., 1993; Obradovich and Woods, 1996; Cook and Woods, 1996). Many of the results and implications of this kind of research are synthesized and discussed in two comprehensive volumes, Billings (1996) and Woods et al. (1994). This paper summarizes the pattern that has emerged from our research, related research, incident reports, and accident investigations. It uses this new understanding of why problems arise to point to new investment strategies that can help us deal with the perceived "human error" problem, make automation more of a team player, and maintain and improve safety.

Woods, David D.↗

Human Spaceflight Applications of Novel Miniature X-Ray Technologies

INTRODUCTION: Radiography (XR) has long been a cornerstone of terrestrial medical imaging, though it has not yet been used in the spaceflight environment. Medical systems for human spaceflight missions are constrained by mass, volume, and power, and until recently, XR systems have been considered too large and power-consuming for spaceflight diagnostic and therapeutic applications. However, the rise of commercial spaceflight and NASA’s refocused efforts on returning crews to the Moon for long-duration missions have introduced a higher degree of medical risk to human spaceflight and require a re-evaluation when optimizing medical system design. Over the last decade, XR devices have miniaturized while maintaining good diagnostic and therapeutic sensitivity and specificity, making new in-flight medical and non-medical XR applications a possibility. Initial research identified several medical conditions where miniature XR would be beneficial for the diagnosis and/or management of medical conditions arising in space, though a more in-depth analysis is required to identify whether XR may add value to the management of such conditions. With this presentation, we aim to introduce the potential utility of miniature XR, review prior work highlighting where XR may be beneficial, and evaluate how miniature XR may reduce medical risk in human spaceflight missions. METHODS: IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments, an expanded list of 119 medical conditions, medical capabilities and resources critical for management of these medical conditions, and the ability for rapid and iterative analysis in the setting of modifiable design reference missions (DRMs). Our first analysis identified which of the 119 medical conditions XR had diagnostic or therapeutic utility for. Subject matter experts (SMEs) recorded which XR views would be performed under ideal terrestrial circumstances for diagnosis/management of each condition, as well as which views are pragmatic for spaceflight limitations. A second analysis utilized IMPACT to identify significant conditions that contribute greatest to medical risk during a notional long-duration Lunar orbit and Lunar surface DRM. Medical system risk estimates include loss of crew life (LOCL), need for return to definitive care (RTDC; medical evacuation), and an estimate of crew task time affected (TTA). Using a standardized semi-quantitative scoring methodology, a deeper evaluation of each of the most significant medical conditions was performed. Data from both of these separate analyses were used to hypothesize what ideal and pragmatic XR studies may impact clinical management of the most significant conditions predicted to lead to medical risk. RESULTS: Approximately 1/3 of the IMPACT conditions were identified as being more effectively or comprehensively assessed or treated with the addition of miniature XR technology. The resulting conditions benefitting diagnostically and therapeutically from XR are revealed, as well as the ideal and pragmatic XR views and medical procedures benefitting from XR. The conditions of clinical significance and those most contributing to risk are also displayed. Among the conditions that contribute greatest to LOCL, four conditions for which XR may improve the diagnosis and management of include: decompression sickness, traumatic shock, dental abscess, and respiratory failure. Among conditions that contributed to RTDC, the evaluation and management of wrist fracture is likely improved by XR. For conditions leading to crew TTA, evaluation and management of EVA shoulder injuries, upper and lower extremity strains, back strains, and EVA hand injuries are likely improved by XR. DISCUSSION: Miniature XR in spaceflight has the potential to improve the evaluation and management of a substantial portion of conditions that most contribute to medical risk. This presentation is an introduction to the possibilities miniature XR provides for future human spaceflight missions and subsequent presenters will expand on potential applications in more detail. LEARNING OBJECTIVES: 1) Understand the previous limitations of using radiography in the management of spaceflight medical conditions; 2) Evaluate the findings from the IMPACT tool analysis, which allows quantification of the benefit miniature XR could provide for managing high-risk medical conditions in long-duration lunar orbit and surface missions, focusing on improvements in crew health outcomes; 3) Analyze case studies where miniature XR technology could reduce the medical risks associated with spaceflight missions, specifically in diagnosing and managing conditions such as decompression sickness, traumatic shock, and EVA-related injuries.

A Anderson↗

Analysis and Test of a Proton Exchange Membrane Fuel Cell Power System for Space Power Applications

An effort is underway to develop a prototype Proton Exchange Membrane (PEM) Fuel Cell breadboard system for fuhlre space applications. This prototype will be used to develop a comprehensive design basis for a space-rated PEM fuel cell powerplant. The prototype system includes reactant pressure regulators, ejector-based reactant pumps, a 4-kW fuel cell stack and cooling system, and a passive, membranebased oxygen / water separator. A computer model is being developed concurrently to analytically predict fluid flow in the oxidant reactant system. Fuel cells have historically played an important role in human-rated spacecraft. The Gemini and Apollo spacecraft used fuel cells for vehicle electrical power. The Space Shuttle currently uses three Alkaline Fuel Cell Powerplants (AFCP) to generate all of the vehicle's 15-20kW electrical power. Engineers at the Johnson Space Center have leveraged off the development effort ongoing in the commercial arena to develop PEM fuel cel ls for terrestrial uses. The prototype design originated from efforts to develop a PEM fuel cell replacement for the current Space Shuttle AFCP' s. In order to improve on the life and an already excellent hi storical record of reliability and safety, three subsystems were focused on. These were the fuel cell stack itself, the reactant circulation devices, and reactant / product water separator. PEM fuel cell stack performance is already demonstrating the potential for greater than four times the useful life of the current Shuttle's AFCP. Reactant pumping for product water removal has historically been accomplished with mechanical pumps. Ejectors offer an effective means of reactant pumping as well as the potential for weight reduction, control simplification, and long life. Centrifugal water separation is used on the current AFCP. A passive, membrane-based water separator offers compatibility with the micro-gravity environment of space, and the potential for control simplification, elimination of moving parts in an oxygen environment, and long life. The prototype system has been assembled from components that have previously been tested and evaluated at the component level. Preliminary data obtained from tests performed with the prototype system, as well as other published data, has been used to validate the analytical component models. These components have been incorporated into an integrated oxidant fluid system model. Results obtained from both the performance tests and the analytical model are presented.

Vasquez, Arturo↗

Urban Air Mobility Noise: Current Practice, Gaps, and Recommendations

AN Air Mobility (UAM) is an opportunity for aviation to improve transportation systems across the world. Representative UAM vehicle attributes include electrical vertical takeoff and landing (eVTOL) vehicles that can accommodate up to 6 passengers (or equivalent cargo), are possibly autonomous, perform missions of up to 100 nautical miles at altitudes up to 3000 ft. above ground level, have flight speeds up to 200 knots, and weigh between 800 and 8000 pounds. Along with the many anticipated benefits, there will be noise issues that need to be addressed. In 2018, NASA formed an Urban Air Mobility Noise Working Group (UNWG) to assemble noise experts from industry, universities and government agencies to identify, discuss, and address UAM noise issues. This oral presentation summarizes technology gaps and goals associated with four areas of interest: Tools & Technologies, Ground & Flight Testing, Human Response & Metrics, and Regulation & Policy, and is drawn from a draft white paper [1] by the same title. Tools & Technologies include noise prediction tools and noise reduction technologies that have been developed for conventional rotorcraft and fixed-wing vehicles that may be applicable or need to be modified for UAM. Prediction tools need to be able to account for variable speed rotors and other temporal variation effects that impact community noise. A reprioritization of noise sources needs to be done since UAM vehicles include multiple rotors/propellers, often in proximity to one another and/or the airframe, with dynamic transition, and new noise sources such as electric motors or hybrid-electric propulsion. Scattering and propagation methods need to be developed that include the vehicle components and surfaces near a receiver such as buildings and vertiports. Validation databases are needed to quantify prediction uncertainties. Prediction tools used to evaluate community noise will need source models appropriate for a wide range of UAM vehicles. Existing noise reduction technologies need to be evaluated and new noise reduction technologies should be developed in anticipation of future noise requirements. Although the prediction and treatment of interior cabin noise is a secondary goal, it is recognized that new tools and methods may be needed due to the uniqueness of the vehicle design and the presence of both acoustic and structure-borne loads. Ground & Flight Testing has been a critical part of validating noise reduction technologies and verifying that an air vehicle is ready for certification. UAM vehicles introduce new challenges for test procedures such as different source noise directivity, unsteady sources due to maneuvers, and a variety of takeoff and approach trajectories. The operating environment will be more complex than current aircraft with the introduction of vertiports in populated areas with “urban canyons” making reflections an important part of noise prediction and annoyance. It is expected that new test procedures and measurement methods will be necessary. Consideration will need to be given for both piloted and autonomous operations. Human Response & Metrics may be very different for UAM noise compared to current experience with airport noise. Current metrics used to certify rotorcraft and fixed-wing aircraft may not be as useful for evaluating UAM noise. Operations at lower altitudes may influence annoyance. Psychoacoustic and community testing will be needed to quantify annoyance and assess appropriate metrics. In addition to conventional noise level metrics, considerations such as audibility and temporal variation of the sound may be required. Differences between indoor or outdoor exposure will have an impact with dependence on urban and residential flight paths. Aircraft noise is currently regulated at a national level and typically involves partnerships with the industry to establish regulations. Regulators realize that current policies and procedures may not be appropriate for some of the emerging air vehicles and new procedures may be needed to address UAM noise. Development of new policies and procedures are needed so that local communities do not hastily attempt to establish their own restrictions that will both limit growth of the market and create an inconsistent and confusing regulatory environment. To expedite this development, it is crucial early measurement data are shared through partnership arrangements to support both noise certification and noise modeling/noise assessment. At the same time, an effective engagement strategy should be developed to address local community noise issues associated with UAM vehicles and flight operations as they arise.

urban air mobility↗

Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation

OBJECTIVES: To develop and validate an automated noninvasive method to quantify mitral regurgitation. BACKGROUND: Automated cardiac output measurement (ACM), which integrates digital color Doppler velocities in space and in time, has been validated for the left ventricular (LV) outflow tract but has not been tested for the LV inflow tract or to assess mitral regurgitation (MR). METHODS: First, to validate ACM against a gold standard (ultrasonic flow meter), 8 dogs were studied at 40 different stages of cardiac output (CO). Second, to compare ACM to the LV outflow (ACMa) and inflow (ACMm) tracts, 50 normal volunteers without MR or aortic regurgitation (44+/-5 years, 31 male) were studied. Third, to compare ACM with the standard pulsed Doppler-two-dimensional echocardiographic (PD-2D) method for quantification of MR, 51 patients (61+/-14 years, 30 male) with MR were studied. RESULTS: In the canine studies, CO by ACM (1.32+/-0.3 liter/min, y) and flow meter (1.35+/-0.3 liter/min, x) showed good correlation (r=0.95, y=0.89x+0.11) and agreement (deltaCO(y-x)=0.03+/-0.08 [mean+/-SD] liter/min). In the normal subjects, CO measured by ACMm agreed with CO by ACMa (r=0.90, p < 0.0001, deltaCO=-0.09+/-0.42 liter/min), PD (r=0.87, p < 0.0001, deltaCO=0.12+/-0.49 liter/min) and 2D (r=0.84, p < 0.0001, deltaCO=-0.16+/-0.48 liter/min). In the patients, mitral regurgitant volume (MRV) by ACMm-ACMa agreed with PD-2D (r= 0.88, y=0.88x+6.6, p < 0.0001, deltaMRV=2.68+/-9.7 ml). CONCLUSIONS: We determined that ACM is a feasible new method for quantifying LV outflow and inflow volume to measure MRV and that ACM automatically performs calculations that are equivalent to more time-consuming Doppler and 2D measurements. Additionally, ACM should improve MR quantification in routine clinical practice.

Non-NASA Center↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. Engineers at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each attachment. This allowed the tool handle to snap onto a fresh swab attachment much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab attachment is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and repressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

Rucker, Michelle A.↗

Comparison of two weighted integration models for the cueing task: linear and likelihood

In a task in which the observer must detect a signal at two locations, presenting a precue that predicts the location of a signal leads to improved performance with a valid cue (signal location matches the cue), compared to an invalid cue (signal location does not match the cue). The cue validity effect has often been explained with a limited capacity attentional mechanism improving the perceptual quality at the cued location. Alternatively, the cueing effect can also be explained by unlimited capacity models that assume a weighted combination of noisy responses across the two locations. We compare two weighted integration models, a linear model and a sum of weighted likelihoods model based on a Bayesian observer. While qualitatively these models are similar, quantitatively they predict different cue validity effects as the signal-to-noise ratios (SNR) increase. To test these models, 3 observers performed in a cued discrimination task of Gaussian targets with an 80% valid precue across a broad range of SNR's. Analysis of a limited capacity attentional switching model was also included and rejected. The sum of weighted likelihoods model best described the psychophysical results, suggesting that human observers approximate a weighted combination of likelihoods, and not a weighted linear combination.

NASA Program Biomedical Research and Countermeasur↗

A Centralized Display for Mission Monitoring

Humans traditionally experience a vigilance decrement over extended periods of time on reliable systems. One possible solution to aiding operators in monitoring is to use polar-star displays that will show deviations from normal in a more salient manner. The primary objectives of this experiment were to determine if polar-star displays aid in monitoring and preliminary diagnosis of the aircraft state. This experiment indicated that the polar-star display does indeed aid operators in detecting and diagnosing system events. Subjects were able to notice system events earlier and they subjectively reported the polar-star display helped them in monitoring, noticing an event, and diagnosing an event. Therefore, these results indicate that the polar-star display used for monitoring and preliminary diagnosis improves performance in these areas for system related events.

Trujillo, Anna C.↗

Extravehicular Activity Technology Development Status and Forecast

The goal of NASA s current EVA technology effort is to further develop technologies that will be used to demonstrate a robust EVA system that has application for a variety of future missions including microgravity and surface EVA. Overall the objectives will be to reduce system mass, reduce consumables and maintenance, increase EVA hardware robustness and life, increase crew member efficiency and autonomy, and enable rapid vehicle egress and ingress. Over the past several years, NASA realized a tremendous increase in EVA system development as part of the Exploration Technology Development Program and the Constellation Program. The evident demand for efficient and reliable EVA technologies, particularly regenerable technologies was apparent under these former programs and will continue to be needed as future mission opportunities arise. The technological need for EVA in space has been realized over the last several decades by the Gemini, Apollo, Skylab, Space Shuttle, and the International Space Station (ISS) programs. EVAs were critical to the success of these programs. Now with the ISS extension to 2028 in conjunction with a current forecasted need of at least eight EVAs per year, the EVA hardware life and limited availability of the Extravehicular Mobility Units (EMUs) will eventually become a critical issue. The current EMU has successfully served EVA demands by performing critical operations to assemble the ISS and provide repairs of satellites such as the Hubble Space Telescope. However, as the life of ISS and the vision for future mission opportunities are realized, a new EVA systems capability will be needed and the current architectures and technologies under development offer significant improvements over the current flight systems. In addition to ISS, potential mission applications include EVAs for missions to Near Earth Objects (NEO), Phobos, or future surface missions. Surface missions could include either exploration of the Moon or Mars. Providing an EVA capability for these types of missions enables in-space construction of complex vehicles or satellites, hands on exploration of new parts of our solar system, and engages the public through the inspiration of knowing that humans are exploring places that they have never been before. This paper offers insight into what is currently being developed and what the potential opportunities are in the forecast.

Chullen, Cinda↗

Environmental Testing of the OVEN System for Lunar Water Extraction and Prospecting

Introduction: The presence of water ice in permanently shadowed regions on the lunar surface [1] may enable a sustained human presence on the Moon with minimal need for consumables. However, in order to develop a long term utilization plan that includes the usage of in-situ water we must first understand the abundance, stratigraphy and distribution of this re-source. Multiple space agencies currently have plans for lunar water prospecting missions. The Optimized Volatile Extraction Node (OVEN) was designed for water prospecting missions that require samples to be weighed, sealed, and heated as the means of determining water concentration. This method of water quantification necessitates a fair amount of automation, so a rigorous environmental test program was performed in order to build confidence in the performance of the OVEN design. The work presented here describes the OVEN environmental test program as well as ongoing efforts to improve on the design. Vibration: The OVEN participated in two rounds of random vibration tests. The first test was a stand-alone test performed at the Energy Systems Test Area of the Johnson Space Center. The second test was an integrated test with the mobile platform developed for the Resource Prospector project. The OVEN survived both tests without damage, but the tests did provide valuable lessons learned with regards to specific operations. Thermal Vacuum: The OVEN was successfully demonstrated at a temperature range of -50 to 75 C in a thermal vacuum chamber. The need to heat motor gearboxes at lower temperatures was predetermined so this test program was completed by implementing a method of gearbox heating that used the existing circuitry within the motors. Dust: A custom dynamometer was built in order to determine the torque required to move the various mechanisms within the OVEN at a range of temperatures. The OVEN system was coated with lunar dust simulant in order to determine mechanism torques under a worst-case operating condition. Sublimation: Sublimation losses within the OVEN were quantified through a series of test configurations, including an integrated test in a thermal vacuum chamber at Glenn Research Center [2]. Current Work: The OVEN subsystem is currently not a component of any existing prospecting missions, but work continues that will take the lessons learned from previous environmental tests and improve on the design in order to be considered for future prospecting opportunities. References: [1] Colaprete, A., Schultz, P., Heldmann, J., Wooden, D., Shirley, M., Ennico, K., ... & Sollitt, L. (2010). Detection of water in the LCROSS ejecta plume. science, 330(6003), 463-468. [2] Kleinhenz, J., Smith, J., Roush, T., Colaprete, A., Zacny, K., Paulsen, G., ... & Paz, A. (2018). Volatiles Loss from water bearing regolith simulant at Lunar Environments. In Earth and Space 2018: Engineering for Extreme Environments (pp. 454-466). Reston, VA: American Society of Civil Engineers.

A Paz↗

Human Spaceflight Recent Conjunctions of Interest

I. During each nine-hour shift (or upon request), the Orbital Safety Analyst (OSA) at JSpOC updates the entire tracked catalog with the latest tracking data from the SSN and screens this catalog against NASA s assets. a) For ISS operations, a 72-hour advance screening is performed. b) For Shuttle orbit operations, a 36-hour advance screening is performed. c) If a vehicle is performing a maneuver during the screening period, OSA uses post-reboost-trajectory data supplied by Mission Control Center-Houston (MCC-H) for screening. II. An automated process is used to detect any conjunctions within 10 x 40 x 40 km box (centered on the vehicle) using Special Perturbation (SP) processing: a) Box dimensions are Radial x Downtrack x Crosstrack. b) Any object found within this box has the tracking tasking level increased to improve (hopefully) its uncertainty in its current and predicted orbital trajectory. c) OSA informs NASA if any object is found inside a 2 x 25 x 25 km box then creates and sends an Orbital Conjunction Message (OCM) to NASA which contains detailed information about the conjunction. d) For Shuttle, the box size used for screening and reporting is altered for special operations (day of rendezvous, launch screening, etc.).

Browns, Ansley C.↗

Rapid determination of ions by combined solid-phase extraction--diffuse reflectance spectroscopy

We introduce colorimetric solid-phase extraction (C-SPE) for the rapid determination of selected ions. This new technique links the exhaustive concentration of an analyte by SPE onto a membrane disk surface for quantitative measurement with a hand-held diffuse reflectance spectrometer. The concentration/measurement procedure is complete in approximately 1 min and can be performed almost anywhere. This method has been used to monitor iodine and iodide in spacecraft water in the 0.1-5.0 ppm range and silver(I) in the range of 5.0-1000 microg/l. Applications to the trace analysis of copper(II), nickel(II), iron(III) and chromium(VI) are described. Studies on the mechanism of extraction showed that impregnation of the disk with a surfactant as well as a complexing reagent results in uptake of additional water, which markedly improves the extraction efficiency.

NASA Program Advanced Human Support Technology↗

Controlled breaks as a fatigue countermeasure on the flight deck

BACKGROUND: A major challenge for flight crews is the need to maintain vigilance during long, highly automated nighttime flights. No system currently exists to assist in managing alertness, and countermeasure options are limited. Surveys reveal many pilots use breaks as an in-flight countermeasure, but there have been no controlled studies of their effectiveness. HYPOTHESIS: We hypothesized that brief, regular breaks could improve alertness and performance during an overnight flight. METHOD: A 6-h, uneventful, nighttime flight in a Boeing 747-400 flight simulator was flown by fourteen two-man crews. The 14 subjects in the treatment group received 5 short breaks spaced hourly during cruise; the 14 subjects in the control group received 1 break in the middle of cruise. Continuous EEG/EOG, subjective sleepiness, and psychomotor vigilance performance data were collected. RESULTS: During the latter part of the night, the treatment group showed significant reductions for 15 min post-break in slow eye movements, theta-band activity, and unintended sleep episodes compared with the control group. The treatment group reported significantly greater subjective alertness for up to 25 min post-break, with strongest effects near the time of the circadian trough. There was no evidence of objective vigilance performance improvement at 15-25 min post-break, with expected performance deterioration occurring due to elevated sleep drive and circadian time. CONCLUSIONS: The physiological and subjective data indicate the breaks reduced nighttime sleepiness for at least 15 min post-break and may have masked sleepiness for up to 25 min, suggesting the potential usefulness of short-duration breaks as an in-flight fatigue countermeasure.

Non-NASA Center↗