High voltage solar cell power generating system for regulated solar array development

A laboratory solar power system regulated by on-panel switches has been delivered for operating high power (3 kw), high voltage (15,000 volt) loads (communication tubes, ion thrusters). The modular system consists of 26 solar arrays, each with an integral light source and cooling system. A typical array contains 2560 series-connected cells. Each light source consists of twenty 500 watt tungsten iodide lamps providing plus or minus 5 per cent uniformity at one solar constant. An array temperature of less than 40 C is achieved using an infrared filter, a water cooled plate, a vacuum hold-down system, and air flushing.

Levy, E., Jr.↗

NASA-GRC Research Activities in High Voltage (HV) Electrical Insulation

This presentation gives an overview of recent research activities at NASA Glenn Research Center (GRC). The presentation covers research associated with materials for high voltage aerospace electrical insulation applications.

Aerospace Materials Aerospace electrical insulatio↗

High-voltage, low-inductance gas switch

A low-inductance, air-insulated gas switch uses a de-enhanced annular trigger ring disposed between two opposing high voltage electrodes. The switch is DC chargeable to 200 kilovolts or more, triggerable, has low jitter (5 ns or less), has pre-fire and no-fire rates of no more than one in 10,000 shots, and has a lifetime of greater than 100,000 shots. Importantly, the switch also has a low inductance (less than 60 nH) and the ability to conduct currents with less than 100 ns rise times. The switch can be used with linear transformer drives or other pulsed-power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phonon-mediated high-voltage detector with background rejection for low-mass dark matter and reactor coherent neutrino scattering experiments

We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. Furthermore, this new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-power programmable high-voltage supply

Converter is used to energize group of proportional-counter event-detection tubes. Supply is programmed by using output signal of low voltage digital-to-analog converter. Programming voltage ranges from 1.53 to 2.91 V in 127 0.0108 mV steps, and it is used to control converter high voltage output which ranges from 700 to 1,335 V in like number of increments.

Stout, D. F.↗

High voltage stability performance of a gamma ray detection device

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Voltage Phosphate Cathodes for Rechargeable Ca-Ion Batteries

Calcium-ion batteries (CIBs) are under investigation as next-generation energy storage devices due to their theoretically high operating potentials and lower costs tied to the high natural abundance of calcium. However, the development of CIBs has been limited by the lack of available positive electrode materials. In this study, for the first time, we report two functional polyanionic phosphate materials as high-voltage cathodes for CIBs at room temperature. NaV 2 (PO 4 ) 3 electrodes were found to reversibly intercalate 0.6 mol of Ca 2+ (81 mA h g –1 ) near 3.2 V (vs Ca 2+ /Ca) with stable cycling performance at a current density of 3.5 mA g –1 . The olivine framework material FePO 4 reversibly intercalates 0.2 mol of Ca 2+ (72 mA h g –1 ) near 2.9 V (vs Ca 2+ /Ca) at a current density of 7.5 mA g –1 in the first cycle. Structural, electronic, and compositional changes are consistent with reversible Ca 2+ intercalation into these two materials.

25 ENERGY STORAGE↗

High voltage transmission microscopy of Surveyor 3 camera shrouds

The internal structure of painted and unpainted aluminum alloy sheet samples from the TV camera shrouds were examined by high-voltage transmission electron microscopy. No clear-cut evidence of radiation damage effects was observed. Noticeable differences in microstructures between the upper visor and the sides and bottom of the lower shroud suggest different thermal histories, and the maximum temperatures due to solar heating are estimated to be between 164 and 319 C. Some correlation between microstructures and maximum estimated temperature is noted. It is felt that the apparent temperature rise due to solar heating will not affect the structural integrity of spacecraft components except possibly for very long periods of exposure. However, substantial thermal diffusion could affect interpretation of solar wind rare gas studies.

Fisher, R. M.↗

Influence of gradual cobalt substitution on lithium nickel phosphate nano-scale composites for high voltage applications

The carbon-free LiNiPO{sub 4} and cobalt doped LiNi{sub 1−x}Co{sub x}PO{sub 4}/C (x = 0.0–1.0) were synthesized and investigated for high voltage applications (> 4 V) for Li-ion batteries. Nano-scale composites were prepared by handy sol–gel approach using citric acid under slightly reductive gas atmosphere (Ar-H{sub 2}, 85:15%). Structural and morphological characteristics of the powders were revealed by X-ray powder diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), high resolution transmission electron microscopy (HR-TEM) and inductively coupled plasma (ICP). Except for a small impurity phase (Ni{sub 3}P), phase pure samples crystallized in the olivine-lattice structure with a linear relationship between lattice parameters (a, b and c) and chemical composition. The FE-SEM images proved that LiNiPO{sub 4}/C particles (50–80 nm) did not agglomerate, and showed that as the cobalt content was higher agglomeration had increased. The electrochemical properties of all electrodes were investigated by galvanostatic charge–discharge measurements. Substitution of Ni{sup 2} {sup +} by Co{sup 2} {sup +} caused higher electronic conductivities and showed more effective Li{sup +} ion mobility. When the cobalt content is 100%, the capacity reached to a higher level (146.2 mA h g{sup −} {sup 1}) and good capacity retention of 85.1% at the end of the 60 cycles was observed. The cycling voltammogram (CV) revealed that LiCoPO{sub 4}/C electrode improved the electrochemical properties. The Ni{sup 3} {sup +}–Ni{sup 2} {sup +} redox couple was not observed for carbon free LiNiPO{sub 4}. Nevertheless, it was observed that carbon coated LiNiPO{sub 4} sample exhibits a significant oxidation (5.26 V)–reduction (5.08 V) peaks. With this study, characteristics of the LiNi{sub 1−x}Co{sub x}PO{sub 4}/C series were deeply evaluated and discussed. - Highlights: • Structural, morphological and electrochemical effects of Co doped LiNi{sub 1−} {sub x}Co{sub x}PO{sub 4}/C electrodes are investigated. • Cheap, effective and simple sol–gel approach is used. • After the 60th cycle, capacity retention is almost 87% for LiCoPO{sub 4}/C electrode. • LiNiPO{sub 4}/C sample exhibits a distinctive oxidation (5.26 V)–reduction (5.08 V) peaks.

36 MATERIALS SCIENCE↗

High-voltage dc power processing thermal control and packaging techniques

The power processor operates in several modes, delivering up to 100 amperes of regulated electrical power, operating at input voltages to 375 volts with outputs controlled by an integral microprocessor. Several alternative packaging concepts are discussed and evaluated. High-voltage design applications, power stage interconnection and EMI considerations are also discussed. Preliminary thermal analyses were performed and the results presented for each conceptual approach with parametric study results given for the selected concept.

Chapter, J. J.↗

Surface regulation enables high stability of single-crystal lithium-ion cathodes at high voltage

Abstract Single-crystal cathode materials for lithium-ion batteries have attracted increasing interest in providing greater capacity retention than their polycrystalline counterparts. However, after being cycled at high voltages, these single-crystal materials exhibit severe structural instability and capacity fade. Understanding how the surface structural changes determine the performance degradation over cycling is crucial, but remains elusive. Here, we investigate the correlation of the surface structure, internal strain, and capacity deterioration by using operando X-ray spectroscopy imaging and nano-tomography. We directly observe a close correlation between surface chemistry and phase distribution from homogeneity to heterogeneity, which induces heterogeneous internal strain within the particle and the resulting structural/performance degradation during cycling. We also discover that surface chemistry can significantly enhance the cyclic performance. Our modified process effectively regulates the performance fade issue of single-crystal cathode and provides new insights for improved design of high-capacity battery materials.

25 ENERGY STORAGE↗

Three regimes of high-voltage breakdown in helium

A quasi-analytical model has been developed to map out the low-pressure (left-hand) branch of the Paschen curve at very high voltage when electrons are in the runaway regime and charge exchange/ionization avalanche by ions and fast neutral atoms becomes important. The model has been applied to helium gas between parallel-plate electrodes, at potentials ranging in magnitude between 10 and 1000 kilovolt. The respective value of reduced electric field E/n varies in the range of 50-6000 kTd (1 kTd =10 -18 Vm 2 ), with reduced density nd (where n is the gas density and d is the interelectrode distance) on the order of 10 20 m -2 . The analytical Paschen curve is compared to those obtained with a detailed Particle-In-Cell/Monte Carlo (PIC/MCC) simulation, and also to experimental measurements. The model provides accurate predictions for E/n up to ~10 3 kTd , constrained by availability and quality of required input data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Test Results from a Simulated High Voltage Lunar Power Transmission Line

The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was modified to simulate high voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high frequency AC power to a lunar facility located at a distance.

Birchenough, Arthur↗

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Load-Dependent Soft-Switching Method of Half-Bridge Current Doubler for High-Voltage Point-of-Load Converter in Data Center Power Supplies

With the increased cloud computing and digital information storage, the energy requirement of data centers keeps increasing. A high-voltage point of load (HV POL) with an input series output parallel structure is proposed to convert 400 to 1 VDC within a single stage to increase the power conversion efficiency. The symmetrical controlled half-bridge current doubler is selected as the converter topology in the HV POL. A load-dependent soft-switching method has been proposed with an auxiliary circuit that includes inductor, diode, and MOSFETs so that the hard-switching issue of typical symmetrical controlled half-bridge converters is resolved. The operation principles of the proposed soft-switching half-bridge current doubler have been analyzed in detail. Then, the necessity of adjusting the timing with the loading in the proposed method is analyzed based on losses, and a controller is designed to realize the load-dependent operation. A lossless RCD current sensing method is used to sense the output inductor current value in the proposed load-dependent operation. In conclusion, experimental efficiency of a hardware prototype is provided to show that the proposed method can increase the converter's efficiency in both heavy- and light-load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding the Capabilities and Limitations of the Controls and Operations of High Voltage Direct Current (HVdc) Converters in Interconnected Electric Power Systems

This project will seek to build a fundamental understanding, and capability, to model and simulate the controls and operations of high voltage direct current (HVdc) converter stations in an electromagnetic simulation environment. While HVdc stations have been operated in the United States for over 50 years, these are typically simple two terminal point-to-point systems. Recently multi-terminal systems have begun to be deployed. The challenge with these new multi-terminal systems is that they often use different control schemes on the different terminals. The interactions of existing and new controls, and the fact that HVdc systems are rates in the 1,000’s of MWs means that small control instabilities can have dramatic impacts to bulk power systems. Despite these challenges, the operational capabilities of HVdc make them an attractive option for the transfer of the large amounts of renewable electricity that will be necessary for decarbonization of the nation’s electrical infrastructure and other sectors.

42 ENGINEERING↗

Multi-scale stabilization of high-voltage LiCoO 2 enabled by nanoscale solid electrolyte coating

LiCoO 2 (LCO) possess a high theoretical specific capacity of 274 mAh g -1 , and currently LCO charged to 4.48 V with a capacity of ~190–195 mAh g -1 is penetrating the commercial markets. Scalable strategies to further enhance the performance of LCO are highly attractive. Here, we develop a scalable ball-milling and sintering method to tackle this long-standing challenge by modifying LCO surface with only 1.5–3.5% ceramic solid electrolyte nanoparticles, specifically Li 1.5 Al 0.5 Ge 1.5 (PO 4 ) 3 (LAGP) as an example. Consequently, the atomic-to-meso multiscale structural stabilities have been significantly improved, even with a high cut-off voltage of 4.5 V vs. Li/Li + , leading to excellent electrochemical stabilities. The nano-LAGP modified Li|LCO cell exhibits high discharge capacity of 196 mAh g -1 at 0.1 C, capacity retention of 88% over 400 cycles, and remarkably enhanced rate capability (163 mAh g -1 at 6 C). These results show significant improvement compared to the Li|LCO cells. The as-prepared graphite|LAGP-LCO full cells also show steady cycling with 80.4% capacity retention after 200 cycles with a voltage cut-off of 4.45 V. This work provides a simple and scalable approach to achieve stable cycling of LCO at high voltage with high energy density.