Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Performance Building Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Advances in Binder Jet Additive Manufacturing

Binder Jetting is a powerful additive manufacturing technology due to its low cost and wide range of types of materials it can shape. The industry partner ExOne has a range of binder jet products for applications such as casting tools, composite layup tools, single-alloy metal components, and more. As such, research and development is of high interest in the area of specialized binders for each type of material, processing technology that improves reliability and quality, and materials to enhance the performance of the final parts. Thus, this work focuses on developing novel binders for sand tools and metal prints, new capabilities in multi-material printing, and build monitoring and correction. The result of this work includes a novel binder system that makes binder jet sand stronger than concrete while still being water soluble, a casting binder that is environmentally friendly and produces better surface finishes on castings, and a binder for metals that reduces the residual carbon.

36 MATERIALS SCIENCE↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Testing of Performance of Optical Fibers Under Irradiation in Intense Radiation Fields, When Subjected to Very High Temperatures

The primary objective of this project is to measure and model the performance of optical fibers in intense radiation fields when subjected to very high temperatures. This research will pave the way for fiber optic and optically based sensors under conditions expected in future high-temperature gas-cooled reactors. Sensor life and signal-to-noise ratios are susceptible to attenuation of the light signal due to scattering and absorbance in the fibers. This project will provide an experimental and theoretical study of the darkening of optical fibers in high-radiation and high-temperature environments. Although optical fibers have been studied for moderate radiation fluence and flux levels, the results of irradiation at very high temperatures have not been published for extended in-core exposures. Several previous multi-scale modeling efforts have studied irradiation effects on the mechanical properties of materials. However, model-based prediction of irradiation-induced changes in silica's optical transport properties has only recently started to receive attention due to possible applications as optical transmission components in fusion reactors. Nearly all damage-modeling studies have been performed in the molecular-dynamics domain, limited to very short times and small systems. Extended-time modeling, however, is crucial to predicting the long-term effects of irradiation at high temperatures, since the experimental testing may not encompass the displacement rate that the fibers will encounter if they are deployed in the VHTR. The project team will pursue such extended-time modeling, including the effects of the ambient and recrystallization. The process will be based on kinetic MC modeling using the concept of amorphous material consisting of building blocks of defect-pairs or clusters, which has been successfully applied to kinetic modeling in amorphized and recrystallized silicon. Using this procedure, the team will model compensation for rate effects, and the interplay of rate effects with the effects of annealing, to accurately predict the fibers' reliability and expected lifetime

36 MATERIALS SCIENCE↗

Technology Solutions Case Study: High-Performance Walls in Hot-Dry Climates

In this project,the Alliance for Residential Building Innovation (ARBI) team worked with builders in California to implement wall assemblies meeting a U-value lower than 0.050 Btu/h-ft2-°F. ARBI and its project team members helped builders identify preferred wall designs that met the requirements of their architects, structural engineers, and purchasing agents and that were acceptable to their subcontractors. Construction methods were observed and documented and construction costs obtained from builders were used to inform cost estimates for a range of advanced wall system types and insulation types. Wall framing types of 2 × 6 (16- and 24-in. on center [o.c.]) and double stud were modeled in Building Energy Optimization (BEopt™) software with cavity insulation levels ranging from R-19 to R-33 (double stud) and exterior rigid insulation of R-4, R-6, and R-8.

ARBI↗

Using EnergyPlus to Perform Dehumidification Analysis on Building America Homes: Preprint

A parametric study was conducted using EnergyPlus version 6.0 to investigate humidity issues on a typical mid-1990s reference home, a 2006 International Energy Conservation Code home, and a high-performance home in a hot-humid climate. The impacts of various dehumidification equipment and controls are analyzed on the high performance home. The study examined the combined effects of infiltrationand mechanical ventilation with balanced and unbalanced mechanical ventilation systems. Indoor relative humidity excursions were examined; specifically, the number of excursions, average excursion length, and maximum excursion length. Space relative humidity, thermal comfort, and whole-house source energy consumption were analyzed for indoor relative humidity set points of 50%, 55%, and 60%. Thestudy showed and explained why similar trends of high humidity were observed in all three homes regardless of energy efficiency, and why humidity problems are not necessarily unique in high-performance homes. Thermal comfort analysis indicated that occupants are unlikely to notice indoor humidity problems. The study confirmed that supplemental dehumidification should be provided to maintainspace relative humidity below 60% in a hot-humid climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tuning Superhydrophilic Nanostructured Surfaces to Maximize Water Droplet Evaporation Heat Transfer Performance

Spraying water droplets on air fin surfaces is often used to augment the performance of air-cooled Rankine power plant condensers and wet cooling tower heat exchangers for building air-conditioning systems. To get the best performance in such processes, the water droplets delivered to the surface should spread rapidly into an extensive, thin film and evaporate with no liquid leaving the surface due to recoil or splashing. This paper presents predictions of theoretical/computational modeling and results of experimental studies of droplet spreading on thin-layer, nanostructured, superhydrophilic surfaces that exhibit very high wicking rates (wickability) in the porous layer. Analysis of the experimental data in the model framework illuminates the key aspects of the physics of the droplet-spreading process and evaporation heat transfer. This analysis also predicts the dependence of droplet-spreading characteristics on the nanoporous surface morphology and other system parameters. The combined results of this investigation indicate specific key strategies for design and fabrication of surface coatings that will maximize the heat transfer performance for droplet evaporation on heat exchanger surfaces. The implications regarding wickability effects on pool boiling processes are also discussed.

Engineering↗

Control Limits for Building Energy End Use Based on Engineering Judgment, Frequency Analysis, and Quantile Regression

Approaches are needed to continuously characterize the energy performance of commercial buildings to allow for (1) timely response to excess energy use by building operators; and (2) building occupants to develop energy awareness and to actively engage in reducing energy use. Energy information systems, often involving graphical dashboards, are gaining popularity in presenting energy performance metrics to occupants and operators in a (near) real-time fashion. Such an energy information system, called Building Agent, has been developed at NREL and incorporates a dashboard for public display. Each building is, by virtue of its purpose, location, and construction, unique. Thus, assessing building energy performance is possible only in a relative sense, as comparison of absolute energy use out of context is not meaningful. In some cases, performance can be judged relative to average performance of comparable buildings. However, in cases of high-performance building designs, such as NREL's Research Support Facility (RSF) discussed in this report, relative performance is meaningful only when compared to historical performance of the facility or to a theoretical maximum performance of the facility as estimated through detailed building energy modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monitoring of Photovoltaic (PV) Performance and Degradation: Integrated Renewable Energy Systems (IRES) - PV Monitoring Task

The Integrated Renewable Energy System (IRES) testbed demonstration at the Pacific Northwest National Laboratory (PNNL) Sequim campus includes development of a suite of capabilities for tracking the performance of photovoltaic (PV) renewable energy components located on a floating platform (floating PV) and on a shoreline building rooftop. The marine environment represents potentially harsh and corrosive conditions for PV modules. Compared to terrestrial PV, potential concerns for offshore PV arising from high humidity and occasional contact with saltwater, marine wildlife, and aquaculture. These environmental factors can reduce electricity generation efficiency and increase the risk of electrical faults, polymer insulation or jacketing degradation and hydrolysis of the PV cell encapsulant materials. Offshore PV modules may also be exposed to lower temperatures and buoyant and vibrating motions with a floating platform. It is not clear how the long-term performance of floating PV will be affected by these factors. To understand expected energy generation through solar cells on a floating platform, monitoring of the performance of PV modules in the marine environment is needed. This report outlines a plan for long-term testing of IRES PV components utilizing resources of the PNNL Material Aging and Detection (MAaD) Science team and the Marine and Coastal Research Laboratory (MCRL). Equipment applicable for onsite testing and real-time monitoring of the PV performance associated with environmental conditions including temperature, solar irradiance, shading and soiling is included. In case of performance loss, equipment for fault detection, failure analysis, material testing, and further troubleshooting are also available. Through establishment of this capabilities, the enabling IRES project sets the stage for future research to advance off-shore and near-shore energy options for businesses and communities.

14 SOLAR ENERGY↗

Towards Lightweight Data Integration Using Multi-Workflow Provenance and Data Observability

Modern large-scale scientific discovery requires multidisciplinary collaboration across diverse computing facilities, including High Performance Computing (HPC) machines and the Edge-to-Cloud continuum. Integrated data analysis plays a crucial role in scientific discovery, especially in the current AI era, by enabling Responsible AI development, FAIR, Reproducibility, and User Steering. However, the heterogeneous nature of science poses challenges such as dealing with multiple supporting tools, cross-facility environments, and efficient HPC execution. Building on data observability, adapter system design, and provenance, we propose MIDA: an approach for lightweight runtime Multi-workflow Integrated Data Analysis. MIDA defines data observability strategies and adaptability methods for various parallel systems and machine learning tools. With observability, it intercepts the dataflows in the background without requiring instrumentation while integrating domain, provenance, and telemetry data at runtime into a unified database ready for user steering queries. We conduct experiments showing end-to-end multi-workflow analysis integrating data from Dask and MLFlow in a real distributed deep learning use case for materials science that runs on multiple environments with up to 276 GPUs in parallel. We show near-zero overhead running up to 100,000 tasks on 1,680 CPU cores on the Summit supercomputer.

Santos Souza, Renan↗

Packaging HEP Heterogeneous Mini-apps for Portable Benchmarking and Facility Evaluation on Modern HPCs

High Energy Physics (HEP) experiments are making increasing use of GPUs and GPU dominated High Performance Computer facilities. Both the software and hardware of these systems are rapidly evolving, creating challenges for experiments to make informed decisions as to where they wish to devote resources. In its first phase, the High Energy Physics Center for Computational Excellence (HEP-CCE) produced portable versions of a number of heterogeneous HEP mini-apps, such as p2r, FastCaloSim, Patatrack and the WireCell Toolkit, that exercise a broad range of GPU characteristics, enabling cross platform and facility benchmarking and evaluation. However, these miniapps still require a significant amount of manual intervention to deploy on a new facility. We present our work in developing turn-key deployments of these mini-apps, where by means of containerization and automated configuration and build techniques such as Spack, we are able to quickly test new hardware, software, environments and entire facilities with minimal user intervention, and then track performance metrics over time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Advantage of Highly Controlled Lighting for Offices and Commercial Buildings

The paper presents results from pilot studies of new 'workstation-specific' luminaires that are designed to provide highly, efficient, customized lighting for open-office cubicles. Workstation specific luminaires have the following characteristics: (1) they provide separate, dimming control of the cubicle's 'ambient' and 'task' lighting components, (2) occupancy sensors and control photosensors are integrated into the fixture's design and operation, (3) luminaires can be networked using physical cabling, microcontrollers and a PC running control software. The energy savings, demand response capabilities and quality of light from the two WS luminaires were evaluated and compared to the performance of a static, low-ambient lighting system that is uncontrolled. Initial results from weeks of operation provide strong indication that WS luminaires can largely eliminate the unnecessary lighting of unoccupied cubicles while providing IESNA-required light levels when the cubicles are occupied. Because each cubicle's lighting is under occupant sensor control, the WS luminaires can capitalize on the fact cubicles are often unoccupied during normal working hours and reduce their energy use accordingly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Transportation and Distributed Energy Systems Risk and Feasibility Assessment for Airport Facilities - CRADA 555 (Abstract)

This CRADA presents the strategy that Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) will take to support PDX in performing a risk assessment for several hydrogen deployment scenarios. It is intended that the deployment of hydrogen at PDX could serve several roles, including decarbonizing its bus fleet and building out a distributed energy system which could also be used to facilitate emergency operations. PDX’s initial plans concern replacing their current fleet of 28 busses with FCEBs. To do so, PDX will need to deploy the hydrogen systems needed to support the buses. This includes hydrogen storage, production, delivery, filling, compression, and maintenance. PDX also has long range plans to build a distributed energy system to support normal and resilient operations. This study will investigate the risks of each plan individually, and a combined plan which serves both. Additionally, PDX is in an area with the potential for high seismic activity, as such this work will also include a seismic risk assessment. A detailed risk assessment using PDX as a test case is necessary to ensure the deployment of large-scale hydrogen is successful and to understand the benefits or drawbacks in contrast to electric only technologies. Many technologies have been proposed that claim to utilize hydrogen for both transportation and distributed energy systems; however, these technologies need to be analyzed as they apply to an actual site. The physical infrastructure and hydrogen use cases for PDX will be analyzed, a risk assessment will be performed on the hydrogen infrastructure and distributed energy system. These assessments will be useful for understanding how each of these technologies would perform as applied to a large public facility and public safety. The results of this CRADA, and an impact of the DOE funding, will evaluate hydrogen as a key fuel for PDX and will accelerate by several years availability of hydrogen, fuel cells, and other low-carbon technologies.

08 HYDROGEN↗

Open Architecture for Cost Savings in Advanced Nuclear Reactors

Recently, nuclear power plant build projects in the West have run over budget due to high capital costs and schedule overruns. Compared to other sources of energy, nuclear power plants have higher capital costs. Reactors are often different at every site, resulting in a lack of standardization. Nuclear is expected to compete with other low carbon sources of energy which have lower capital costs making it essential for nuclear to develop ways of reducing costs. Strategies such as standardization, learning rates, modularization, and schedule reduction in advanced reactors can reduce nuclear costs by about 40%. Standardization as a way of cutting capital costs has been explored even in large nuclear power plants. Standardization of certain plant components can result in lower component and installation costs and higher learning from experience. Standardization can be achieved by adopting a criterion of key performance indicators and general design principles for a specific system or component such as the balance of plant. Modularization allows the construction of certain components of SMRs in a factory, which saves time, increases productivity, and encourages higher learning rates. Production learning decreases the time and the cost related to an activity. The potential for modularized components of advanced reactors to be manufactured in factories makes it conducive to achieving higher learning rates. Developing large-capacity nuclear programs through sequential builds cultivates a higher learning rate, which in effect may reduce schedule overruns. Open architecture has been identified as a way to drive standardization among advanced reactor designs and result in cost savings. Open architecture (OA) is defined as a design enabling a diverse supply chain by defining and publishing requirements of systems or equipment in functional and/or interface terms, utilizing technical standards in widespread use. Currently, the nuclear industry’s approach is to use closed architecture, making most designs proprietary. However, collaboration between various advanced reactor vendors and suppliers utilizing the concept of open architecture can result in modular and standardized architecture of subsystems or subcomponents of a nuclear power plant. Completely standardizing nuclear power plants may be impossible, however, certain common subsystems amongst the various reactor designs could be standardized and/or access a wider supply chain and leverage existing learning from other sectors. Open architecture will save time and allocate resources to the parts of the plants that have the most unique features. A key advantage of open architecture is its ability to improve production learning across advanced reactors (AR) types in the industry, by providing and utilizing the same kind of component. Sodium fast reactor (SFR), High Temperature Gas Reactor (HTGR) and Molten Salt Reactor (MSR) are the advanced reactors considered for this project. This paper aims to determine the cost savings in advanced reactor programs due to open architecture learning rate. This work is an extension of work done on light water reactor small modular reactors; the cost methodology was utilized to investigate the impact of open architecture on advanced reactors with a particular focus on sodium fast reactors. The cost data on sodium fast reactors used in the model presented the most adequate information required for the analysis.

Advanced Nuclear Reactors↗

Design Report on the MiniFuel Instrumented Test Apparatus for Understanding Radiation Effects

Most nuclear fuels irradiations at Oak Ridge National Laboratory (ORNL) over the past decade have been conducted using MiniFuel—a static capsule design employing subscale fuel specimens to collect separate-effects irradiated fuel performance data. Irradiation conditions for MiniFuel experiments are predicted pre-test using reactor physics, and thermal models are verified post-irradiation via SiC dilatometry and various spectrometry methods. Relevant fuel performance parameters are also observed post-irradiation in a hot cell, thereby providing a single data point for each parameter representing the cumulative effects of the irradiation conditions. Substantially more data can be harvested from a single test and within a shorter duration by instrumenting irradiation vehicles and measuring desired quantities in situ. This report presents the design and analysis of the MiniFuel INstrumented Irradiation Test Apparatus for Understanding Radiation Effects (MINITAURE)—an instrumented test rig based on the separate-effects MiniFuel concept that aims to capture fission gas release (FGR) and thermal conductivity degradation of fuel specimens during irradiation in the High Flux Isotope Reactor (HFIR). MINITAURE will be integrated with the Materials Irradiation Facility (MIF) located in the HFIR building outside the reactor containment. The MIF will act as the instrumentation and control center for the experiment, enabling real-time feedback from in situ sensors and control of irradiation temperatures via a gas delivery system. Two unique capsule designs were developed to capture each phenomenon: the thermal conductivity capsule, which uses a thermopile method to estimate fuel specimen thermal conductivity, and the fission gas release capsule, which will have continuous flowing gas communication to high-purity germanium detectors that are housed in the MIF for monitoring FGR. This report details the reactor physics and heat transfer modeling activities that were used to inform the experiment design and predict capsule performance. It also describes out-of-pile activities conducted to stand up this new capability and verify the measurement techniques. Modeling efforts to date have demonstrated the feasibility of the in situ measurement techniques and supported the development of the MINITAURE assembly configuration. Out-of-pile testing of the thermal conductivity measurement shows promise in capturing relative changes in thermal conductivity. However, significant errors exist in the measured absolute value, posing a need for further refinement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes: Tucson, Arizona and Chico, California (Fact Sheet)

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Second Wind Triton Data with Meteorological Tower Measurements

With the increased interest in remote sensing of wind information in recent years, it is important to determine the reliability and accuracy of new wind measurement technologies if they are to replace or supplement conventional tower-based measurements. In this study, we present the results of an analysis characterizing the measurement performance of a state-of-the-art SOund Detection And Ranging (sodar) device when compared to a high-quality tower measurement program. Second Wind Inc. (Somerville, MA, USA) provided NREL with more than six months of data from a measurement program conducted near an operating wind farm in western Texas.

17 WIND ENERGY↗