Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

DEVELOPMENT OF A SMALL INTEGRATED HEAT PUMP (IHP) FOR NET ZERO ENERGY HOMES

An IHP prototype was developed and tested over a range of operating modes and conditions. Test data was used to validate a detailed analysis model and the validated analytical tool was used to calculate the yearly performance of air- and ground-source IHP system designs optimized for R-410A in five major US cities. For the air-source IHP version, the simulation results showed ~46-67% energy savings depending upon location. For the ground-source IHP version, the simulation showed over 50% savings in all locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capillary Pumped Heat Transfer (CHT) Experiment

The operation of Capillary Pumped Loops (CPL's) in low gravity has generally been unable to match ground-based performance. The reason for this poorer performance has been elusive. In order to investigate the behavior of a CPL in low-gravity, an idealized, glass CPL experiment was constructed. This experiment, known as the Capillary-driven Heat Transfer (CHT) experiment, was flown on board the Space Shuttle Columbia in July 1997 during the Microgravity Science Laboratory mission. During the conduct of the CHT experiment an unexpected failure mode was observed. This failure mode was a result of liquid collecting and then eventually bridging the vapor return line. With the vapor return line blocked, the condensate was unable to return to the evaporator and dry-out subsequently followed. The mechanism for this collection and bridging has been associated with long wavelength instabilities of the liquid film forming in the vapor return line. Analysis has shown that vapor line blockage in present generation CPL devices is inevitable. Additionally, previous low-gravity CPL tests have reported the presence of relatively low frequency pressure oscillations during erratic system performance. Analysis reveals that these pressure oscillations are in part a result of long wavelength instabilities present in the evaporator pores, which likewise lead to liquid bridging and vapor entrapment in the porous media. Subsequent evaporation to the trapped vapor increases the vapor pressure. Eventually the vapor pressure causes ejection of the bridged liquid. Recoil stresses depress the meniscus, the vapor pressure rapidly increases, and the heated surface cools. The process then repeats with regularity.

Hallinan, Kevin P.↗

Bounding Limitations in the Practical Design of Adsorption Heat Pump Water Heaters

The boundary temperatures for any sorption-based technology can be estimated on the basis of Trouton s hypothesis that isosteres, extrapolated to infinite pressure (or analogously to infinite temperature) meet at a single point. In this paper we discuss the consequences of this hypothesis for many sorption devices that are thermally operated, suitable for exploiting renewable energy resources, or making better use of high or low level thermal energy. Trouton s hypothesis is independent of the working fluids making it particularly useful to both liquid-vapor and solid-vapor systems. We exemplify the use of the derived boundary temperatures derived from Trouton s hypothesis to important processes such as ice making, space cooling in hot climates, deep freezing, and residential hot water production. The boundary temperatures help determine which sorption or solar heating technology may be better suited to serve the given application, or whether it is beyond the scope of sorption systems.

heat pumps↗

National Simulation Analysis of 120V Heat Pump Water Heaters

This presentation details efforts to integrate 120V HPWHs into ResStock, including detailing the required upgrades to the ResStock tools. Example results from this dataset are shown to inform the audience of what will be available in the next release.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molecular heat pump for rotational states

In this work, we investigate the theory for three different unidirectional population-transfer schemes in trapped multilevel systems which can be utilized to cool molecular ions. The approach we use exploits the laser-induced coupling between the internal and motional degrees of freedom so that the internal state of a molecule can be mapped onto the motion of that molecule in an external trapping potential. By sympathetically cooling the translational motion back into its ground state, the mapping process can be employed as part of a cooling scheme for molecular rotational levels. This step is achieved through a common mode involving a laser-cooled atom trapped alongside the molecule. For the coherent mapping, we will focus on adiabatic passage techniques which may be expected to provide robust and efficient population transfers. By applying far-detuned chirped adiabatic rapid passage pulses, we are able to achieve an efficiency of better than 98% for realistic parameters and including spontaneous emission. Even though our main focus is on cooling molecular states, the analysis of the different adiabatic methods has general features which can be applied to atomic systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

ComStock Measure Scenario Documentation: Standard Performance Heat Pump Rooftop Unit With New Windows

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Heat Pump Thermal Storage and Power Cycle for CSP (Final Technical Report)

Pumped thermal energy storage (PTES) is a storage system that stores electricity in thermal reservoirs. In this project, methods of integrating PTES with concentrating solar power (CSP) systems were investigated and their feasibility evaluated. Hybrid "solar-PTES" devices can provide both flexible renewable power generation as well as a variety of electricity storage services. Techno-economic models of PTES and solar-PTES were developed and used to assess their performance, cost, and commercial viability. Systems were optimized using multi-objective optimization techniques. The value that these storage devices provide to the grid was estimated using production cost modelling. Key advances made in this project include the development of detailed techno-economic models that improve state-of-the-art assessments of these technologies. Off-design models were developed and used in grid-analysis models. This work describes for the first time how PTES and solar-PTES behave over a range of operating points and assesses the value that these systems can provide to the electrical grid. Feedback was obtained from experts in the field, which clarified key technological and economic barriers that must be addressed to improve the feasibility of these devices.

14 SOLAR ENERGY↗

Eliminating the Need for Refrigerants Using New Liquid and Salt-Based Cooling and Heat-Pumping Technology (CRADA Final Report)

Calion Technologies, Inc. project team investigated various embodiments of the ionocaloric cycle. Ionocaloric technology provides a new platform for all heating and cooling that is zero-GWP, non-toxic, non-hazardous, and non-flammable. It is well-poised to replace vapor compression technology which uses high-GWP refrigerants which are on track to account for 25% of our global warming budget. Developing the ionocaloric technology as a drop-in replacement for vapor compression was the primary research thrust under this CRADA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two phase capillary pumped heat transfer in the Instrument Thermal Test Bed

An experimental study of the thermal performance of two evaporators installed in the Instrument Thermal Test Bed (ITTB) was conducted. The ITTB was operated as a capillary pumped loop (CPL) with a transport length of approximately 12 meters. Empirical determinations of a general start up procedure, overall heat transfer coefficient, and minimum operating power were accomplished for each evaporator. Additionally, a detailed thermal model was developed for the High Power Spacecraft Thermal Management (HPSTM) evaporator and validated.

Didion, Jeffrey R.↗