Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Thermal Radiation Anomalies Associated with Major Earthquakes

Recent developments of remote sensing methods for Earth satellite data analysis contribute to our understanding of earthquake related thermal anomalies. It was realized that the thermal heat fluxes over areas of earthquake preparation is a result of air ionization by radon (and other gases) and consequent water vapor condensation on newly formed ions. Latent heat (LH) is released as a result of this process and leads to the formation of local thermal radiation anomalies (TRA) known as OLR (outgoing Longwave radiation, Ouzounov et al, 2007). We compare the LH energy, obtained by integrating surface latent heat flux (SLHF) over the area and time with released energies associated with these events. Extended studies of the TRA using the data from the most recent major earthquakes allowed establishing the main morphological features. It was also established that the TRA are the part of more complex chain of the short-term pre-earthquake generation, which is explained within the framework of a lithosphere-atmosphere coupling processes.

Ouzounov, Dimitar↗

Multiphysics Analysis of Li Cooled Divertor Substrate During Loss of Coolant Accident (LOCA)

In the ongoing study of potential designs for liquid metal (LM) plasma-facing components (PFCs), so-called “slow” and “fast” Li flow divertor concepts are under investigation. In the previous studies on design and analysis of the slow Li flow divertor and comparison with the fast Li flow divertor, the magnetohydrodynamics (MHD)/heat transfer effects of the Li flowing inside the substrate as a second coolant were comprehensively investigated under the normal steady-state operation conditions. Here, in the present study, the multiphysics analysis is extended to the unsteady abnormal divertor scenario where the Li layer on top of the substrate does not provide full coverage or even totally disappears for a certain period of time, so that the substrate becomes directly exposed to the incident high plasma heat flux. Such an unwanted event may happen regardless of the concept of the divertor and is worth detailed investigations, typically referred to as a loss of coolant accident (LOCA). To address this situation, a simplified scoping analysis is conducted first in 2-D, and then an integrated 3-D modeling is performed using a time-dependent multiphysics model in COMSOL Multiphysics that integrates LM MHD, heat transfer, and solid mechanics. The main goal is to evaluate conditions under which the major material limits, such as the maximum allowable temperature, stress, and displacement of the substrate, can still be met. It was shown that the maximum time over which the substrate of RAFM steel can retain structural integrity during the LOCA is around 0.2 ∼ 0.3 s. Any divertor concept that utilizes RAFM steel as a substrate material and liquid Li as a second coolant should take such a permitted time into consideration.

divertor↗

Development of Lightweight Radiators for Lunar Based Power Systems

This report discusses application of a new lightweight carbon-carbon (C-C) space radiator technology developed under the NASA Civil-Space Technology Initiative (CSTI) High Capacity Power Program to a 20 kWe lunar based power system. This system comprises a nuclear (SP-100 derivative) heat source, a Closed Brayton Cycle (CBC) power conversion unit with heat rejection by means of a plane radiator. The new radiator concept is based on a C-C composite heat pipe with integrally woven fins and a thin walled metallic liner for containment of the working fluid. Using measured areal specific mass values (1.5 kg/m2) for flat plate radiators, comparative CBC power system mass and performance calculations show significant advantages if conventional heat pipes for space radiators are replaced by the new C-C heat pipe technology.

Juhasz, Albert J.↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

An Integrated Approach to Predicting Ash Deposition and Heat Transfer in Coal-Fired Boilers

The overall goal of this project is to develop via measurements and simulations an advanced online technology to predict, monitor and manage fireside ash deposition in a coal-fired boiler allowing for more efficient operations under a range of load conditions and fuel property variability. With this in place fuel sorting and blending can be done upstream and operations can be optimized to compensate for load and fuel properties. In support of this objective, three experimental campaigns were undertaken during the course of the project to measure ash deposition rates within the boiler at different fuel flow rates and its ash composition variability. Simulations of the experimental conditions representing actual geometry, operational scenarios in terms of air flow rates, coal flow rates as well as coal compositions, heating values, and particle size distributions were also carried out. Deposition rates were predicted using a unique particle kinetic energy and viscosity based ash deposition methodology whose validity was ascertained by comparing against deposition rate measurements for widely varying operating conditions and ash compositions in a lab-scale furnace. With a unique end-to-end combustion modeling methodology established and different simulation scenarios carried out, the results from our computational fluid dynamic (CFD) simulations in conjunction with the plant data summarized in this report were used to refine Microbeam Technology Incorporated’s MTI CSPI-CT Tool to predict and monitor fire-side ash deposition under a range of load conditions and fuel property variability in real time.

01 COAL, LIGNITE, AND PEAT↗

Radiation Backgrounds at Cosmic Dawn: X-Rays from Compact Binaries

We compute the expected X-ray diffuse background and radiative feedback on the intergalactic medium (IGM) from X-ray binaries prior to and during the epoch of reionization. The cosmic evolution of compact binaries is followed using a population synthesis technique that treats separately neutron stars and black hole binaries in different spectral states and is calibrated to reproduce the observed X-ray properties of galaxies at z ≲ 4. Together with an updated empirical determination of the cosmic history of star formation, recent modeling of the stellar mass–metallicity relation, and a scheme for absorption by the IGM that accounts for the presence of ionized H ii bubbles during the epoch of reionization, our detailed calculations provide refined predictions of the X-ray volume emissivity and filtered radiation background from “normal” galaxies at z ≳ 6. Radiative transfer effects modulate the background spectrum, which shows a characteristic peak between 1 and 2 keV. Because of the energy dependence of photoabsorption, soft X-ray photons are produced by local sources, while more energetic radiation arrives unattenuated from larger cosmological volumes. While the filtering of X-ray radiation through the IGM slightly increases the mean excess energy per photoionization, it also weakens the radiation intensity below 1 keV, lowering the mean photoionization and heating rates. Numerical integration of the rate and energy equations shows that the contribution of X-ray binaries to the ionization of the bulk IGM is negligible, with the electron fraction never exceeding 1%. Direct He i photoionizations are the main source of IGM heating, and the temperature of the largely neutral medium in between H ii cavities increases above the temperature of the cosmic microwave background (CMB) only at z ≲ 10, when the volume filling factor of H ii bubbles is already ≳0.1. Therefore, in this scenario, it is only at relatively late epochs that neutral intergalactic hydrogen may be observable in 21 cm emission against the CMB.

79 ASTRONOMY AND ASTROPHYSICS↗

Integration and software for thermal test of heat rate sensors

A minicomputer controlled radiant test facility is described which was developed and calibrated in an effort to verify analytical thermal models of instrumentation islands installed aboard the space shuttle external tank to measure thermal flight parameters during ascent. Software was provided for the facility as well as for development tests on the SRB actuator tail stock. Additional testing was conducted with the test facility to determine the temperature and heat flux rate and loads required to effect a change of color in the ET tank external paint. This requirement resulted from the review of photographs taken of the ET at separation from the orbiter which showed that 75% of the external tank paint coating had not changed color from its original white color. The paint on the remaining 25% of the tank was either brown or black, indicating that it had degraded due to heating or that the spray on form insulation had receded in these areas. The operational capability of the facility as well as the various tests which were conducted and their results are discussed.

Wojciechowski, C. J.↗

Power generation plant integrating concentrated solar power receiver and pressurized heat exchanger

A power plant includes a solar receiver heating solid particles, a standpipe receiving solid particles from the solar receiver, a pressurized heat exchanger heating working fluid by heat transfer through direct contact with heated solid particles flowing out of the bottom of the standpipe, and a flow path for solid particles from the bottom of the standpipe into the pressurized heat exchanger that is sealed by a pressure P produced at the bottom of the standpipe by a column of heated solid particles of height H. The flow path may include a silo or surge tank comprising a pressure vessel connected to the bottom of the standpipe, and a non-mechanical valve. The power plant may further include a turbine driven by heated working fluid discharged from the pressurized heat exchanger, and a compressor driven by the turbine.

14 SOLAR ENERGY↗

Abstract for CRADA among NETL, Mälardalen University, University College Cork (acting through its Tyndall National Institute), and Micro Electricity Generation Association

GeoCoHorT aims to accelerate the transition to 4 th generation district heating and cooling (4GDHC) in Europe and globally, by assessing, optimizing, and demonstrating the integration of shallow geothermal heat extraction with other renewable sources and smart buildings. The target geo-source is ground water from River Shannon (Limerick, Ireland), which will provide both an efficiency and noise-reduction benefit to the micro-district and a method of combatting climate-change-warming of the Shannon Estuary. The heat from this low-temperature source will be recycled and supplied to a smart district located in Limerick, Ireland, through heat pumps powered by renewable electricity and by means of a suitable DH network design. The mandate is to find solutions that work for entire communities in a fair and sustainable manner, with the involvement of the communities themselves to highlight their needs. The project brings together four partners from Ireland, Sweden, and the U.S.A. with strong multi-disciplinary competencies. The Tyndall Institute at University of Cork (UCC) and Mälardalen University (MDU) will design and optimize the 4GDH micro-district system, and the Micro Electricity Generation Association (MEGA) will work with the community to build a sense of ownership of the Climate Challenge and ensure close community involvement. The National Energy Technology Laboratory of the U.S. Department of Energy (NETL) will design the prospective geo-fluid loop to optimize heat-extraction effectiveness with ecological safety and assess the environmental benefits of the proposed solutions. Industrial advisors (Eskilstuna Strängnäs Energi och Miljö (ESEM) and Mimer in Sweden, and Smart MPOWER in Ireland) will steer the technology development to meet the needs of public utilities and consumers. Current infrastructure in the smart district in Limerick (demonstration site of an EU Lighthouse project) will be exploited and modified with support of MEGA, UCC, and MPOWER to integrate micro-DH from low-temperature heat sources, such as the river heat, and to allow increasing penetration of prosumers in the grid. Additional case studies will be developed with the help of industrial advisors to extend the results to other regions (e.g., Sweden and USA) and provide valuable insights for the development of 4GDH worldwide.

15 GEOTHERMAL ENERGY↗

Performance Evaluation of the ThermoLift Natural Gas Fired Air Conditioner and Cold-Climate Heat Pump

ThermoLift is currently developing its Thermal Compression Heat Pump (TCHP™), a natural-gas driven air conditioner and cold-climate heat pump, which can provide space heating, water heating, and air conditioning simultaneously in a single device. The system has broad application as a combined heating, ventilation, and air-conditioning (HVAC) solution with the benefit of substantial energy, cost, and greenhouse gas (GHG) reductions. Unlike traditional vapor compression heat-pumps, the TCHP™ uses helium as a working fluid in place of high global warming potential (GWP) refrigerants. The development effort has produced three iterations or generations of prototypes with advancement of the technology readiness level (TRL) from TRL-1 (TCHP™ Gen 1.0) to TRL-5 (TCHP™ Gen 3.0). In August of 2013, the US DOE solicited the submission of proposals through funding opportunity announcement DE-FOA-0000823, Building Technologies Innovations Program. The Office of Energy Efficiency and Renewable Energy (EERE) subsequently accepted ThermoLift’s proposal to develop a heat pump system based on the Hofbauer cycle, a new cycle that supplants the Vuilleumier cycle and provided funding for prototype evaluation at Oak Ridge National Laboratory (ORNL). ORNL is a widely known research center for developing and evaluating building technologies. Through its Building Technologies Research and Integration Center, ORNL has unique capabilities which allows them to collaborate with industry and academia to advance building component technologies. The TCHP™ Gen 3.0 prototype was shipped to ORNL on July 23, 2018. After installation and integration of the heat pump into ORNL’s test facility and performing instrumentation validation and calibration, extended operation of the heat pump was achieved during continuous operation on August 6, 2018, and includes various heating and cooling temperature ranges and performance analysis. The Gen 3.0 prototype was evaluated at four “ambient” temperatures: −25°C, −8.33°C, 8.33°C, and 20°C, (−13°F, 17°F, 47°F, and 68°F) denoted as test points 1-4, respectively. For heating, cycle coefficients of performance (COP) at the four “ambient” temperatures were found to be 1.30, 1.46, 1.52, and 1.61, respectively. Furthermore, there is no capacity reduction as the inlet temperature to the cold heat exchanger (HX) decreases. The heating capacity delivered by the TCHP was found to be 12 kW at -25°C. Finally, this final report identifies measures for obtaining further efficiency improvements.

42 ENGINEERING↗

Thermodynamic stability and contributions to the Gibbs free energy of nanocrystalline Ni 3 Fe

In this work, the heat capacities of nanocrystalline Ni 3 Fe and control materials with larger crystallites were measured from 0.4–300 K. The heat capacities were integrated to obtain the enthalpy, entropy, and Gibbs free energy and to quantify how these thermodynamic functions are altered by nanocrystallinity. From the phonon density of states (DOS) measured by inelastic neutron scattering, we find that the Gibbs free energy is dominated by phonons and that the larger heat capacity of the nanomaterial below 100 K is attributable to its enhanced phonon DOS at low energies. Besides electronic and magnetic contributions, the nanocrystalline material has an additional contribution at higher temperatures, consistent with phonon anharmonicity. The nanocrystalline material shows a stronger increase with temperature of both the enthalpy and entropy compared to the bulk sample. Its entropy exceeds that of the bulk material by 0.4 $k_B$/atom at 300 K. This is insufficient to overcome the enthalpy of grain boundaries and defects in the nanocrystalline material, making it thermodynamically unstable with respect to the bulk control material.

36 MATERIALS SCIENCE↗