Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Automated Demand Response Opportunities in Wastewater Treatment Facilities

Wastewater treatment is an energy intensive process which, together with water treatment, comprises about three percent of U.S. annual energy use. Yet, since wastewater treatment facilities are often peripheral to major electricity-using industries, they are frequently an overlooked area for automated demand response opportunities. Demand response is a set of actions taken to reduce electric loads when contingencies, such as emergencies or congestion, occur that threaten supply-demand balance, and/or market conditions occur that raise electric supply costs. Demand response programs are designed to improve the reliability of the electric grid and to lower the use of electricity during peak times to reduce the total system costs. Open automated demand response is a set of continuous, open communication signals and systems provided over the Internet to allow facilities to automate their demand response activities without the need for manual actions. Automated demand response strategies can be implemented as an enhanced use of upgraded equipment and facility control strategies installed as energy efficiency measures. Conversely, installation of controls to support automated demand response may result in improved energy efficiency through real-time access to operational data. This paper argues that the implementation of energy efficiency opportunities in wastewater treatment facilities creates a base for achieving successful demand reductions. This paper characterizes energy use and the state of demand response readiness in wastewater treatment facilities and outlines automated demand response opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Protocol for Electrochemical Evaluations and State of Charge Diagnostics of a Symmetric Organic Redox Flow Battery

Redox flow batteries have been considered as one of the most promising stationary energy storage solutions for improving the reliability of the power grid and deployment of renewable energy technologies. Among the many flow battery chemistries, nonaqueous flow batteries have the potential to achieve high energy density because of the broad voltage windows of nonaqueous electrolytes. However, significant technical hurdles exist currently limiting nonaqueous flow batteries to demonstrate their full potential, such as low redox concentrations, low operating currents, under-explored battery status monitoring, etc. In an attempt to address these limitations, we report a nonaqueous flow battery based on a highly soluble, redox-active organic nitronyl nitroxide radical compound, 2-phenyl-4,4,5,5-tetramethylimidazoline-1-oxyl-3-oxide (PTIO). This redox materials exhibits an ambipolar electrochemical property with two reversible redox pairs that are moderately separated by a voltage gap of ~1.7 V. Therefore, PTIO can serve as both anolyte and catholyte redox materials to form a symmetric flow battery chemistry, which affords the advantages such as high effective redox concentrations and low irreversible redox material crossover. The PTIO flow battery shows decent electrochemical cyclability under cyclic voltammetry and flow cell conditions; an improved redox concentration of 0.5 M PTIO and operational current density of 20 mA cm-2 were achieved in flow cell tests. Moreover, we show that Fourier transform infrared (FTIR) spectroscopy could measure the PTIO concentrations during the PTIO flow battery cycling and offer reasonably accurate detection of the battery state of charge (SOC) as cross-validated by electron spin resonance measurements. This study suggests FTIR can be used as a reliable online SOC sensor to monitor flow battery status and ensure battery operations stringently in a safe SOC range.

FTIR↗

Advanced Metering Infrastructure for Distribution Planning and Operation: Closing the Loop on Grid-Edge Visibility

In the recent history of electric utilities, the potential to have visibility of the grid edge is gaining significance for the reliable planning and operation of a clean energy smart grid. Before the recent large-scale customer adoption of distributed energy resources (DERs), distribution networks were planned with a simpler fit-and-forget philosophy. The importance of customer-sited DERs to achieve climate change goals marks a major shift for utility operations. Changes to traditional fit-and-forget planning paradigms require better availability of grid-edge data. Smart metering is an enterprise-wide tool that is enabling visibility when and where it has been most needed. As of 2020, the rollout of smart metering, or advanced metering infrastructure (AMI), had reached more than 100 million meters in the United States, and nearly half of all electricity customers are now equipped with a smart meter (Figure 1). Smart meters are quickly becoming a ubiquitous data capture feature of smart grids. AMI enables utilities to record and measure electricity usage and power-flow metrics at a minimum of hourly intervals and at least once a day. At a minimum, AMI enables interval metering, automatic meter reading enabling accurate and time-interval billing, and the ability to provide feedback on customer energy consumption.

advanced metering infrastructure↗

Weather-Driven Resilience for Distribution Systems

With increasing billion dollar disasters due to weather events, it is of utmost priority for utility and grid operators to maintain and enhance the resilience of distribution grid. Traditionally, such analysis were conducted with reliability metrics alone. However, with increasing complexity of distribution grid and advancements in grid edge resources, evaluating grid resilience is challenging and involves multi-faceted analysis of the impact of weather events on the distribution grid. This presentation provides background, details, and future works in the field of weather-driven resilience for power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automating Component-Level Stress Measurements for Inverter Reliability Estimation

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous operating modes which induce new stresses on the power electronics components. In this work, an experimental and theoretical framework is introduced which couples laboratory-measured component stress with advanced inverter functionality and derives a reduction in useful lifetime based on an applicable reliability model. Multiple DER devices were instrumented to calculate the additional component stress under multiple reactive power setpoints to estimate associated DER lifetime reductions. A clear increase in switch loss was demonstrated as a function of irradiance level and power factor. This is replicated in the system-level efficiency measurements, although magnitudes were different—suggesting other loss mechanisms exist. Using an approximate Arrhenius thermal model for the switches, the experimental data indicate a lifetime reduction of 1.5% when operating the inverter at 0.85 PF—compared to unity PF—assuming the DER failure mechanism thermally driven within the H-bridge. If other failure mechanisms are discovered for a set of power electronics devices, this testing and calculation framework can easily be tailored to those failure mechanisms.

Flicker, Jack (ORCID:0000000212232154)↗

Grand challenges of wind energy science – meeting the needs and services of the power system

The share of wind power in power systems is increasing dramatically, and this is happening in parallel with increased penetration of solar photovoltaics, storage, other inverter-based technologies, and electrification of other sectors. Recognising the fundamental objective of power systems, maintaining supply–demand balance reliably at the lowest cost, and integrating all these technologies are significant research challenges that are driving radical changes to planning and operations of power systems globally. In this changing environment, wind power can maximise its long-term value to the power system by balancing the needs it imposes on the power system with its contribution to addressing these needs with services. A needs and services paradigm is adopted here to highlight these research challenges, which should also be guided by a balanced approach, concentrating on its advantages over competitors. The research challenges within the wind technology itself are many and varied, with control and coordination internally being a focal point in parallel with a strong recommendation for a holistic approach targeted at where wind has an advantage over its competitors and in coordination with research into other technologies such as storage, power electronics, and power systems.

17 WIND ENERGY↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Modular Power Converters for PV Applications

This report describes technical opportunities to serve as parts of a technological roadmap for Shoals Technologies Group in power electronics for PV applications. There are many different power converter circuits that can be used for solar inverter applications. The present applications do not take advantage of the potential for using common modules. We envision that the development of a power electronics module could enable higher reliability by being durable and flexible. Modules would have fault current limiting features and detection circuits such that they can limit the current through the module from external faults and can identify and isolate internal faults such that the remaining modules can continue to operate with only minimal disturbance to the utility or customer. Development of a reliable, efficient, low-cost, power electronics module will be a key enabling technology for harnessing more power from solar panels and enable plug and play operation. Power electronics for computer power supplies, communication equipment, and transportation have all targeted reliability and modularity as key requirements and have begun concerted efforts to replace monolithic components with collections of common smart modules. This is happening on several levels including (1) device level with intelligent control, (2) functional module level, and (3) system module. This same effort is needed in power electronics for solar applications. Development of modular units will result in standard power electronic converters that will have a lower installed and operating cost for the overall system. These units will lead to increased adaptability and flexibility of solar inverters. Incorporating autonomous fault current limiting and reconfiguration capabilities into the modules and having redundant modules will lead to a durable converter that can withstand the rigors of solar power generation for more than 30 years. Our vision for the technology roadmap is that there is no need for detailed design of new power converters for each new application or installation. One set of modules and controllers can be pre-developed and the only design question would be how many modules need to be in series or parallel for the specific power requirement. Then, a designer can put the modules together and add the intelligent reconfigurable controller. The controller determines how many modules are connected, but it might also ask for user input for the specific application during setup. The modules include protection against faults and can reset it, if necessary. In case of a power device failure, the controller reconfigures itself to continue limited operation until repair which might be as simple as taking the faulty module out and inserting a new module. The result is cost savings in design, maintenance, repair, and a grid that is more reliable and available. This concept would be a perfect fit for the recently announced funding opportunity announcement (DE-FOA-0000653) on Plug and Play Photovoltaics.

14 SOLAR ENERGY↗

Optimization of X-ray tomography through a cooperative computing system in grid

Cooperative Computing implemented as Cooperative Computing System (CCS) in grid has been proved a considerably reliable technique to execute the tasks with real time constraints in a grid environment. This technique can be applied in many high performance distributed computing applications. HPC has a large number of applications in various fields of physics. One such application in radiation physics is X-ray tomography. X-Ray tomography contains numerous applications in various fields of science, technology and research. As the technology is changing from analog to digital in almost all the scenarios, this paper presents an idea towards the attachment of X-ray tomography assembly to HPC environment so as to obtain the highly reliable optimization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing power system restoration with damaged communications

Utility procedures for power system blackstart and restoration typically assume that energization decisions can be reliably communicated across the grid. In reality, the communications and control network would likely also be affected in power outages, such as those caused by extreme weather events or cyber-attacks. This paper studies the effect of damage to the power system communications and control infrastructure on restoration operations following a blackout. We model the communications infrastructure as a graph, overlaying the power grid, and imposing the requirement that every energized element in the power grid be observable from a control center. We expand on a specialized branch-and-bound algorithm from the literature to optimize the restoration process and devise an initialization heuristic and a rounding heuristic to improve solution speed. We perform numerical experiments on synthetic systems for Illinois and Texas with outages based on a solar flare or hurricane. We compare the results of our specialized branch-and-bound algorithm to the results from (i) the initialization heuristic alone, (ii) a variation of this heuristic that we use as a baseline, and (iii) the restoration optimization for the power system without communications constraints. Here, we find that damage to the communications infrastructure significantly increases the time required to re-energize the grid. Moreover, by simultaneously optimizing communications repairs and grid energization decisions, we are able to re-energize the grid significantly faster than if communications repairs and energization decisions were made independently or with partial coordination, motivating improvements to current industry practice.

97 MATHEMATICS AND COMPUTING↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cyber–physical perspective on smart grid design and operation

Emerging computation and communication technologies ubiquitously deployed in smart grids introduce unprecedented opportunities by enabling vigorous development of innovative business models and applications that aim for improving system efficiency, reliability, resiliency, and interoperability. Smart grids are typical cyber–physical systems (CPSs). The heterogeneous and complex nature of smart grids presents significant challenges introduced by the tight coupling of computation, communication, and physical systems. Here, the authors first provide an overview of smart grids from a CPS perspective. Then, the authors discuss the opportunities and challenges in smart grid design and operation. Next, a co‐design framework is introduced and used for designing wide‐area damping controller as one of many CPS applications that can be abstracted from various power system layers. The authors conclude that developing a theoretical modelling framework is critical for understanding and managing the complexity and interoperability of smart grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Least-cost targets and avoided fossil fuel capacity in India’s pursuit of renewable energy

India has set aggressive targets to install more than 400 GW of wind and solar electricity generation by 2030, with more than two-thirds of that capacity coming from solar. This paper examines the electricity and carbon mitigation costs to reliably operate India’s grid in 2030 for a variety of wind and solar targets (200 GW to 600 GW) and the most promising options for reducing these costs. We find that systems where solar photovoltaic comprises only 25 to 50% of the total renewable target have the lowest carbon mitigation costs in most scenarios. This result invites a reexamination of India’s proposed solar-majority targets. We also find that, compared to other regions and contrary to prevailing assumptions, meeting high renewable targets will avoid building very few new fossil fuel (coal and natural gas) power plants because of India’s specific weather patterns and need to meet peak electricity demand. However, building 600 GW of renewable capacity, with the majority being wind plants, reduces how often fossil fuel power plants run, and this amount of capacity can hold India’s 2030 emissions below 2018 levels for less than the social cost of carbon. With likely wind and solar cost declines and increases in coal energy costs, balanced or wind-majority high renewable energy systems (600 GW or ≈ 45% share by energy) could result in electricity costs similar to a fossil fuel-dominated system. As an alternative strategy for meeting peak electricity demand, battery storage can avert the need for new fossil fuel capacity but is cost effective only at low capital costs (≈ USD 150 per kWh).

14 SOLAR ENERGY↗

Grid resolution requirement of chemical explosive mode analysis for large eddy simulations of premixed turbulent combustion

Full Article Figures & data References Citations Metrics Reprints & Permissions Read this article Abstract The grid resolution requirement for trustworthy Chemical Explosive Mode Analysis (CEMA) in Large Eddy Simulation (LES) of premixed turbulent combustion is proposed. Explicit filtering, to emulate the effect of the LES filter, is applied to one-dimensional laminar flame and three-dimensional planar turbulent flames across a wide range of Karlovitz numbers (5 - 239). The identification of the flame front by CEMA is found relatively insensitive to the cell size (Δ), while the combustion mode identification shows more significant sensitivity. Specifically, increasing Δ falsely enhances the auto-ignition and local extinction modes and suppresses the diffusion-assisted mode. Limited dependence of the CEMA performance on the turbulent combustion regime (Karlovitz number) is observed. A simple grid size criterion for reliable CEMA mode identification in LES is proposed as Δ ≲ δ L /2; The criterion can be relaxed to Δ ≲ δ L in the laminar flame limit. Furthermore, theoretical analysis is conducted on an idealised chemistry-diffusion system. The effects of the filtering process and turbulence on the local combustion mode are demonstrated, which is consistent with the numerical observations. Further, by incorporating turbulent combustion models in CEMA, potential improvement in identifying local combustion modes can be expected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instability of evaporation fronts in the interstellar medium

The neutral component of the interstellar medium is segregated into the cold neutral medium (CNM) and warm neutral medium (WNM) as a result of thermal instability. It was found that a plane-parallel CNM-WNM evaporation interface, across which the CNM undergoes thermal expansion, is linearly unstable to corrugational disturbances, in complete analogy with the Darrieus-Landau instability (DLI) of terrestrial flames. We perform a full linear stability analysis as well as nonlinear hydrodynamic simulations of the DLI of such evaporation fronts in the presence of thermal conduction. We find that the DLI is suppressed at short length scales by conduction. The length and time scales of the fastest growing mode are inversely proportional to the evaporation flow speed of the CNM and its square, respectively. In the nonlinear stage, the DLI saturates to a steady state where the front deforms to a finger-like shape protruding toward the WNM, without generating turbulence. The evaporation rate at nonlinear saturation is larger than the initial plane-parallel value by a factor of ∼2.4 when the equilibrium thermal pressure is 1800 k {sub B} cm{sup –3} K. The degrees of front deformation and evaporation-rate enhancement at nonlinear saturation are determined primarily by the density ratio between the CNM and WNM. We demonstrate that the Field length in the thermally unstable medium should be resolved by at least four grid points to obtain reliable numerical outcomes involving thermal instability.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring magnetic fields in laser-driven coils with dual-axis proton deflectometry

Abstract By driving hot electrons between two metal plates connected by a wire loop, high power lasers can generate multi-tesla, quasi-static magnetic fields in miniature coil targets. Many experiments involving laser-coil targets rely on proton deflectometry directed perpendicular to the coil axis to extract a measurement of the magnetic field. In this paper, we show that quantitative measurements using perpendicular probing are complicated by the presence of GV m −1 electric fields in the target that develop on sub-ns timescales. Probing parallel to the coil axis with fiducial grids is shown to reliably separate the electric and magnetic field measurements, giving current estimates of I ≈ 5 kA in 1 mm- and 2 mm-diameter wire loops. An analytic model of proton deflection in electric and magnetic fields is used to benchmark results from the particle-in-cell code and help deconvolve the magnetic and electric field deflections. Results are used to motivate a new experimental scheme that combines a single-plate target with axial proton probing and direct current measurements. This scheme has several important advantages over the traditional target and diagnostic set-up, enabling the robust measurement of coil magnetic fields and plasma properties, as well as making it easier to validate different theoretical models at a range of laser intensities.

Bradford, P. (ORCID:0000000296186342)↗

Decarbonization and technology cost drivers: considerations for potential future thermoelectric water use in the power sector

The power sector is currently undergoing significant changes, driven by a combination of factors, including decarbonization and technology innovation. This study aims to assess implications of these drivers on U.S. power sector technology futures and the associated water and environmental implications for cooling thermoelectric power plants. Specifically, we evaluate four decarbonization scenarios for the contiguous United States that vary in assumptions concerning demand growth and technology costs, with technology costs driving alternative outcomes that prioritize either technologies that require low amounts of water (such as wind, solar, and battery) or high amounts of water (such as nuclear and carbon capture and storage). These scenarios are executed in a power sector capacity expansion model and compared to two reference scenarios that assume status quo with policy and cost drivers. Our analysis indicates that future U.S. thermoelectric water withdrawals could decrease by 25%–60%, but water consumption could more than triple in some scenarios. These changes are driven by a combination of retirement of some power facilities, shifts in cooling technologies, and new technology deployment. The water use patterns vary across the United States, with the eastern regions demonstrating a lot more variability in water consumption across scenarios than western regions. However, local concerns can influence these possible investments, since increased water consumption can exacerbate water scarcity, leading to conflicts among competing users and affecting regional social, environmental, and economic dynamics. Future work should consider possible costs associated with alternate water sources, as well as improve the representation of water constraints within simulations. Inclusion of extreme events and alternate modeling platforms (e.g. production cost modeling and resource adequacy) may also be warranted to further stress test the robustness of these possible technology futures. Such assessments will be critical for ensuring decarbonization and other infrastructure-oriented investments lead to a reliable and resilient power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement-Based Approach for Inertia-Trend Analysis of the US Western Interconnection

Rising deployment of inverter-based resources (IBRs), characterized by a lack of rotating mass, is decreasing the total inertia of the system. This can lead to an increased Rate of Change of Frequency (RoCoF) during the disturbance and false activation of protective devices. There is a need to assess the inertia over the past decade amidst the evolving landscape of renewable energy sources to develop strategies for integrating energy storage, enhancing resilience measures, and ensuring the stable and reliable operation of the grid. Therefore, a realistic assessment of the inertia trend using a measurement-based approach that addresses the limitations of existing models is proposed. An inertia study of the Western Interconnection in the United States is performed utilizing the data from 2013 to 2022, obtained from FNET/ GridEye network. The three-second RoCoF time window is chosen for the study as it showed an optimum balance between a strong correlation with the power imbalance (ΔP) and minimum inclusion of primary response from governor. The obtained inertia trend result shows a small percentage declination of inertia over the decade. By examining the result alongside a generation mix graph, insights are gained into the dynamic interplay between shifting energy landscape and system inertia.

Dulal, Saurav↗