Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geant4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Cosmic Ray Interactions in Shielding Materials

This document provides a detailed study of materials used to shield against the hadronic particles from cosmic ray showers at Earth’s surface. This work was motivated by the need for a shield that minimizes activation of the enriched germanium during transport for the MAJORANA collaboration. The materials suitable for cosmic-ray shield design are materials such as lead and iron that will stop the primary protons, and materials like polyethylene, borated polyethylene, concrete and water that will stop the induced neutrons. The interaction of the different cosmic-ray components at ground level (protons, neutrons, muons) with their wide energy range (from kilo-electron volts to giga-electron volts) is a complex calculation. Monte Carlo calculations have proven to be a suitable tool for the simulation of nucleon transport, including hadron interactions and radioactive isotope production. The industry standard Monte Carlo simulation tool, Geant4, was used for this study. The result of this study is the assertion that activation at Earth’s surface is a result of the neutronic and protonic components of the cosmic-ray shower. The best material to shield against these cosmic-ray components is iron, which has the best combination of primary shielding and minimal secondary neutron production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modelling Energy Loss Mechanisms and a Determination of the Electron Energy Scale for the CDF Run II W Mass Measurement

The calibration of the calorimeter energy scale is vital to measuring the mass of the W boson at CDF Run II. For the second measurement of the W boson mass at CDF Run II, two independent simulations were developed. This thesis presents a detailed description of the modification and validation of Bremsstrahlung and pair production modelling in one of these simulations, UCL Fast Simulation, comparing to both geant4 and real data where appropriate. The total systematic uncertainty on the measurement of the W boson mass in the W → ev e channel from residual inaccuracies in Bremsstrahlung modelling is estimated as 6.2 ±3.2 MeV/c 2 and the total systematic uncertainty from residual inaccuracies in pair production modelling is estimated as 2.8± 2.7 MeV=c 2 . Two independent methods are used to calibrate the calorimeter energy scale in UCL Fast Simulation; the results of these two methods are compared to produce a measurement of the Z boson mass as a cross-check on the accuracy of the simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preliminary study of the inclusion of Water-based Liquid Scintillator in the WATCHMAN Detector

This note summarizes an effort to characterize the effects of adding water-based liquid scintillator to the WATCHMAN detector. A detector model was built in the Geant4 Monte Carlo toolkit, and the position reconstruction of positrons within the detector was compared with and without scintillator. This study highlights the need for further modeling studies and small-scale experimental studies before inclusion into a large-scale detector, as the benefits compared to the associated costs are unclear.

47 OTHER INSTRUMENTATION↗

Dark Matter Search in a Beam-Dump eXperiment (BDX) at Jefferson Lab

MeV-GeV dark matter (DM) is theoretically well motivated but remarkably unexplored. This proposal presents the MeV-GeV DM discovery potential for a $\sim$1 m$^3$ segmented CsI(Tl) scintillator detector placed downstream of the Hall A beam-dump at Jefferson Lab, receiving up to 10$^{22}$ electrons-on-target (EOT) in 285 days. This experiment (Beam-Dump eXperiment or BDX) would be sensitive to elastic DM-electron and to inelastic DM scattering at the level of 10 counts per year, reaching the limit of the neutrino irreducible background. The distinct signature of a DM interaction will be an electromagnetic shower of few hundreds of MeV, together with a reduced activity in the surrounding active veto counters. A detailed description of the DM particle $\chi$ production in the dump and subsequent interaction in the detector has been performed by means of Monte Carlo simulations. Different approaches have been used to evaluate the expected backgrounds: the cosmogenic background has been extrapolated from the results obtained with a prototype detector running at INFN-LNS (Italy), while the beam-related background has been evaluated by GEANT4 Monte Carlo simulations. The proposed experiment will be sensitive to large regions of DM parameter space, exceeding the discovery potential of existing and planned experiments in the MeV-GeV DM mass range by up to two orders of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Importance Sampling Variance Reduction in GRESS ATMOSIM

This document is intended to introduce the importance sampling method of variance reduction to a Geant4 user for application to neutral particle Monte Carlo transport through the atmosphere, as implemented in GRESS ATMOSIM.

47 OTHER INSTRUMENTATION↗

Model Uncertainties for Valencia RPA Effect for MINERvA

This technical note describes the application of the Valencia RPA multi-nucleon effect and its uncertainty to QE reactions from the GENIE neutrino event generator. The analysis of MINERvA neutrino data in Rodrigues et al. PRL 116 071802 (2016) paper makes clear the need for an RPA suppression, especially at very low momentum and energy transfer. That published analysis does not constrain the magnitude of the effect; it only tests models with and without the effect against the data. Other MINERvA analyses need an expression of the model uncertainty in the RPA effect. A well-described uncertainty can be used for systematics for unfolding, for model errors in the analysis of non-QE samples, and as input for fitting exercises for model testing or constraining backgrounds. This prescription takes uncertainties on the parameters in the Valencia RPA model and adds a (not-as-tight) constraint from muon capture data. For MINERvA we apply it as a 2D ($q_0$,$q_3$) weight to GENIE events, in lieu of generating a full beyond-Fermi-gas quasielastic events. Because it is a weight, it can be applied to the generated and fully Geant4 simulated events used in analysis without a special GENIE sample. For some limited uses, it could be cast as a 1D $Q^2$ weight without much trouble. This procedure is a suitable starting point for NOvA and DUNE where the energy dependence is modest, but probably not adequate for T2K or MicroBooNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab: an update on PR12-16-001

This document is an update to the proposal PR12-16-001 Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab submitted to JLab-PAC44 in 2016 reporting progress in addressing questions raised regarding the beam-on backgrounds. The concerns are addressed by adopting a new simulation tool, FLUKA, and planning measurements of muon fluxes from the dump with its existing shielding around the dump. First, we have implemented the detailed BDX experimental geometry into a FLUKA simulation, in consultation with experts from the JLab Radiation Control Group. The FLUKA simulation has been compared directly to our GEANT4 simulations and shown to agree in regions of validity. The FLUKA interaction package, with a tuned set of biasing weights, is naturally able to generate reliable particle distributions with very small probabilities and therefore predict rates at the detector location beyond the planned shielding around the beam dump. Second, we have developed a plan to conduct measurements of the muon ux from the Hall-A dump in its current configuration to validate our simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Working Toward a Precision Neutrino Beam [Slides]

As the Deep Underground Neutrino Experiment nears construction, the existing neutrino facilities at Fermilab provide opportunities to test and refine methods characterizing high precision neutrino beams. MARGARITA is a water Cherenkov stopped muon detector that features twin photomultiplier tubes and two small, slightly differing detector volumes. The two detector volumes are designed to exploit the difference between the lifetimes of positive and negative muons in matter in order to characterize a neutrino beam. MARGARITA is currently being developed in the Neutrinos at the Main Injector (NuMI) beamline. The NuMI beamline also contains an existing muon monitoring system that has been underutilized. Improved analysis via ROOT and simulation via Geant4 of past, current, and future data from the muon monitors during an array of operating conditions could provide useful insights for any experiment at Fermilab utilizing a precision neutrino beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation dosages for NbFeB magnets in CBETA (CBETA Tech Note 040)

This paper creates models of various components of CBETA and conducts simulations of electron beam irradiation to calculate dose rates on NdFeB permanent magnets. Using Geant4 simulation software, two models were created which red 42MeV beams and measured the resulting dosage of radiation on nearby permanent magnets. In the first model, the beam was incident on a viewscreen, and the maximum dose rate obtained on a nearby magnet was .97±.0007 Gy/μC which corresponds to 1910±3 hrs of continuous operation at a beam current of 150 pA, if the maximum allowed dose is 1 kGy. The second model is of a splitter section, and the results indicate that radiation dose rate increases as a function of the incident angle as the beam enters the 42MeV chamber line. In Model II, a half-quadrupole magnet experienced the highest dose rate at 0.0909±.0005 Gy/μC, corresponding to 20,400±140 hrs of operation at 150 pA until the magnet reaches a dose of 1 kGy. For this second model, it was also observed that vertical momenta proportionally decrease radiation dosage on the magnets.

43 PARTICLE ACCELERATORS↗

NOvA muon energy scale systematic

The systematic uncertainty on the correspondence between muon range and energy is developed for the NOvA neutrino experiment. NOvA consists of two detectors, the Near Detector at Fermilab and the Far Detector in northern Minnesota. Total errors are developed for the Near Detector, with its Muon Catcher treated separately, the Far Detector, and all combinations of correlated and uncorrelated errors between these three detectors. The absolute errors for the Near Detector (1.0%), the Far Detector (0.9%), and the fully correlated error shared by them (0.9%) are strongly dominated by Geant4’s treatment of the Bethe density effect. At the Near Detector, the next biggest uncertainty is from stray hits caused by neutron capture pile-up. Other contributions are marginally significant, with the biggest, in descending order, being due to external measurements of the mean excitation energies of elements, detector mass accounting, and modification of energy loss by chemical binding. For the Muon Catcher, the absolute error is expressed as an offset instead of a percentage: 21MeV. The density effect (at higher energies) and neutron capture pile-up (at lower energies) are the strongly dominant errors. The relative error between the Near and Far Detectors is 0.4% and is strongly dominated by neutron capture pile-up at the Near Detector, with a subdominant contribution from detector mass accounting.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NOvA Muon Energy Scale Systematic

The systematic uncertainty on the correspondence between muon range and energy is developed for the NOvA neutrino experiment. NOvA consists of two detectors, the Near Detector at Fermilab and the Far Detector in northern Minnesota. Total errors are developed for the Near Detector, with its Muon Catcher treated separately, the Far Detector, and all combinations of correlated and uncorrelated errors between these three detectors. The absolute errors for the Near Detector (1.0%), the Far Detector (0.9%), and the fully correlated error shared by them (0.9%) are strongly dominated by Geant4's treatment of the Bethe density effect. At the Near Detector, the next biggest uncertainty is from stray hits caused by neutron capture pile-up. Other contributions are marginally significant, with the biggest, in descending order, being due to external measurements of the mean excitation energies of elements, detector mass accounting, and modification of energy loss by chemical binding. For the Muon Catcher, the absolute error is expressed as an offset instead of a percentage: 21 MeV. The density effect (at higher energies) and neutron capture pile-up (at lower energies) are the strongly dominant errors. The relative error between the Near and Far Detectors is 0.4% and is strongly dominated by neutron capture pile-up at the Near Detector, with a subdominant contribution from detector mass accounting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Benchmarking of a Proton Recoil Neutron Detector

A neutron spectroscopy detector was designed for analysis of neutrons produced by Lawrence Livermore National Laboratory's neutron imaging project. The detector was built and benchmarked at Lawrence Berkeley National Laboratory's Deuteron-Breakup Neutron Facility. Similar to a proton-recoil telescope, the setup detects protons elastically scattered from neutrons incident on a thin sheet of polyethylene. A silicon charged-particle detector several centimeters away detects the protons in a small angular range, such that the energies of the incident neutrons can be reconstructed from the energy of the detected proton and the scattering angle. A quick benchmarking experiment demonstrated that large backgrounds would be a significant challenge, and that additional measures must be taken to reduce these backgrounds. A Geant4 model of the detector was used to predict the sources of these backgrounds and how best to reduce them.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Particle/Ray Interaction Simulation Manager (PRISM) Assessment Report

The Particle/Ray Interaction Simulation Manager (PRISM) is a software tool developed by Triple Ring Technologies (TRT), http://www.tripleringtech.com/, under a Small Business Innovation Research Award from the Department of Homeland Security (DHS) to investigate the utility of simulations in X-ray-based explosive detection systems. The PRISM tool is intended to provide a standardized and intuitive user interface to control and configure realistic simulations of X-ray imaging systems. It includes a command-line interface that enables the user to configure simulated X-ray radiography and computed tomography (CT) systems. It allows the import of computer-aided design (CAD) models of objects and it supports Monte Carlo simulation engines such as GEANT4. PRISM is designed to simulate realistic X-ray projection images including scatter, noise, and various detector effects such as quantum efficiency, lag, and veiling glare. At the request of DHS, the authors assessed PRISM’s capabilities to simulate data generated by a Micro-CT test-bed system (MCT-TB) housed at the Lawrence Livermore National Laboratory (LLNL). This document describes the results of that assessment.

42 ENGINEERING↗

Study of tunable narrow-band THz and high-intensity channeling radiation sources with a 50 MeV class photo-injector

This thesis describes the generation of frequency tunable narrow-band THz radiation and energy tunable quasi-monochromatic hard X-rays using a 50 MeV class photoinjector. We produce micro-bunched beams using a slit-mask and a chicane and then generate THz radiation by sending them to a metallic foil or passing through a small wiggler. As for hard-X-ray generation, we employ channeling radiation (CR) which can emit quasi-monochromatic hard X-rays with a single crystal and an electron beam with an energy of below 100 MeV. We performed each demonstration experiment to verify the theory and simulations at the FAST (Fermi Accelerator Science and Technology) facility in Fermilab. The results of the experiments on the micro-bunching were in agreement with those of the theory and simulations. On the other hand, the expected energy spectrum could not be obtained due to the pile-up of the detectors. We performed particle tracking simulations with Geant4 and identified that the X-ray detectors measured bremsstrahlung radiated from beam pipe caused by the dark currents from the photo cathode, and also detected the characteristic X-rays of lead around the detectors emitted by the bremsstrahlung. In this thesis, the details on the theory, the simulation results, the experiment results of THz/CR are described, and the suggestions for the next experiments through the considerations are also shown.

43 PARTICLE ACCELERATORS↗

Deterministic Calculation of Gamma-Ray Transport Spectra with InterScatter.

Gamma-ray transport describes the way in which high-energy photons interact with matter. There are many well established, general purpose gamma transport calculation frameworks (such as GEANT4, MCNP, PARTISN, and GADRAS) that allow for complex generalized calculations, but they are typically not designed to be integrated into other multi-process, multi-platform applications, not designed for rapid computation, or their complexity leads to user errors. In this report, we introduce InterScatter: a deterministic simulation designed to quickly and easily calculate gamma-ray transport spectra for a 1D shielding geometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deterministic Calculation of Gamma-Ray Transport Spectra with InterScatter

Gamma-ray transport describes the way in which high-energy photons (gamma rays and x-rays) interact with matter. There are many well established, general purpose gamma transport calculation frameworks (such as GEANT4, MCNP, PARTISN, and GADRAS [1] [2] [3] [4]) that allow for complex generalized calculations, but they are typically not designed to be integrated into other multi-process, multi-platform applications, not designed for rapid computation, or their complexity leads to user errors. In this report, we introduce InterScatter: a deterministic simulation designed to quickly and easily calculate gamma-ray transport spectra for a 1D shielding geometry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics Models in Detector Simulation [PowerPoint]

This talk provides an overview of the detector simulation physics models needs of HEP experiments and is restricted to LHC experiments (ALICE, ATLAS, CMS, LHCb) and Belle II and will be focused on the Geant4 toolkit. Other experiments are discussed in other talks. This talk also discuss differences and commonalities among experiments and will identify opportunities for collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Fission Products at CARIBU: Near Field Detection (Q4/FY19 Quarterly Progress Report)

We have been having ongoing discussions about the analysis and the text of the 95 Zr manuscript with our collaborators at Texas A&M University (TAMU). K. Kolos has travelled to Texas to discuss, once again, some details of our GEANT4 simulation used to determine the gas-counter efficiency. In that process, we discovered that there was a slight disagreement (~0.5%) between our results and the results obtained with the EGS code used by the TAMU group. We are currently working to determine and magnitude and source of the discrepancy. This has taken a considerable amount of time and, unfortunately, has hindered us from sending out the paper to all of our collaborators. We also recently found out that Benjamin Schroeder, the Texas A&M student supported by the CENTUAR Center of Excellence who joined our project earlier this year, has decided to leave graduate school after obtaining his Master Thesis. Although this is a loss for our team, we do not foresee this to cause a major disruption in the project. Our TAMU collaborators are still committed to the success of these measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗