Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gamma decay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Gamma-ray burst high time-resolution spectral observations made with the Solar Maximum Mission

The gamma-ray bursts of April 19 and 21, 1980, and March 1, 1981, are characterized on the basis of observations obtained at 25-500 keV and time resolution 128 msec using the hard-X-ray-burst spectrometer of the SMM satellite. The data are presented graphically, and the parameters determined by fitting three theoretical models to the data for each phase (rising phase, decay phase, and valleys between pulses) are given in tables. Models used are thin thermal bremsstrahlung with or without absorption lines, thermal synchrotron with or without absorption lines, and power law with exponential cutoff.

Desai, U. D.↗

The Optical Counterpart to Gamma-Ray Burst GRB 970228 Observed Using the Hubble Space Telescope

Although more than 2,000 astronomical gamma-ray bursts (GRBS) have been detected, and numerous models proposed to explain their occurrence, they have remained enigmatic owing to the lack of an obvious counterpart at other wavelengths. The recent ground-based detection of a transient optical source in the vicinity of GRB970228 may therefore have provided a breakthrough. The optical counterpart appears to be embedded in an extended source which, if a galaxy, as has been suggested would lend weight to those models that place GRBs at cosmological distances. Here we report, observations using the Hubble Space Telescope of the transient counterpart and extended source 26 and 39 days after the initial gamma-ray outburst. We find that the counterpart has faded since the initial detection (and continues to fade), but the extended source exhibits no significant change in brightness between the two dates of the observations reported here. The size and apparent constancy of the extended source imply that it is extragalactic, but its faintness makes a definitive statement about its nature difficult. Nevertheless, the decay profile of the transient source is consistent with a popular impulsive-fireball model13, which assumes a merger between two neutron stars in a distant galaxy.

Sahu, K. C.↗

First data from the CUPID-Mo neutrinoless double beta decay experiment

The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors feature background suppression using a dual-readout scheme with Li$_{2}$MoO$_4$ crystals complemented by Ge bolometers for light detection. The detection of both heat and scintillation light signals allows the efficient discrimination of $\alpha$ from $\gamma$&$\beta$ events. In this proceedings, we discuss results from the first 2 months of data taking in spring 2019. In addition to an excellent bolometric performance of 6.7$\,$keV (FWHM) at 2615$\,$keV and an $\alpha$ separation of better than 99.9% for all detectors, we report on bulk radiopurity for Th and U. Finally, we interpret the accumulated physics data in terms of a limit of $T_{1/2}^{0\nu}\,> 3\times10^{23}\,$yr for $^{100}$Mo and discuss the sensitivity of CUPID-Mo until the expected end of physics data taking in early 2020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HEAO 3 discovery of Al-26 in the interstellar medium

A new analysis technique was used with HEAO 3 satellite gamma ray data to quantify the galactic 1809 keV emission. A method of bins was applied in summing for specific scan directions, followed by fitting the source and background components. The 1809 keV line of Al-26 was significant because of the recent discovery that Al-26 was overabundant in meteoritic material and implanted during solar system formation. The HEAO 3 flux indicated a current decay of 3 solar masses of Al-26 per year in the interstellar medium, possibly occurring in red giants and massive main sequence stars. The ratio of the observed Al-26 to the Al-27 flux was similar to that measured in meteorites, which suggests that the ratio is normal for the galactic medium and that no supernova triggered the protosolar nebular collapse.

Mahoney, W. A.↗

Swift: Results from the first year of the mission

The Swift gamma-ray burst explorer was launched on Nov. 20,2004 from Cape Canaveral, Florida. The first instrument onboard became fully operational less than a month later. Since that time the Burst Alert Telescope (BAT) on Swift has detected more than one hundred gamma-ray bursts (GRBs), most of which have also been observed within two minutes by the Swift narrow-field instruments: the X-Ray Telescope (XRT) and the Ultra-Violet and Optical Telescope (UVOT). Swift trigger notices are distributed worldwide within seconds of the trigger through the Gamma-ray burst Coordinates Network (GCN) and a substantial fraction of GRBs have been followed up by ground and space-based telescopes, ranging in wavelength from radio to TeV. Results have included the first rapid localization of a short GRB and further validation of the theory that short and long bursts have different origins; detailed observations of the short-term power-law decay of burst afterglows leading to an improved understanding of the fireball model; and detection of the most distant GRB ever found. Swift is also a sensitive X-ray observatory with capabilities to monitor galactic and extragalactic transients on a daily basis, carry out the first all-sky hard X-ray survey since HEAO-1, and study in detail the spectra of X-ray transients. significant results, both in GRB science and in the search for and study of hard X-ray sources. In this talk I will provide a broad overview of the Swift mission and its most significant results, both in GRB science and in the search for and study of hard X-ray sources.

Krimm, H. A.↗

Delayed Neutron Temporal Signatures for Uranium Enrichment Measurement NA-241 SGTech (Final Report)

Nondestructive determination of uranium enrichment is a core capability for nuclear material accounting and control (NMAC) and safeguards verification measurements; however, traditional gamma spectroscopy-based techniques for enrichment measurement rely on significant assumptions of material composition and geometry, precluding their use in scenarios where a heterogeneous spatial distribution of enrichments is encountered. As an alternative, we are developing a technique to use delayed neutron temporal signatures for the measurement of uranium enrichment. Each uranium isotope has unique delayed neutron group yields, resulting in a unique delayed neutron decay time profile which can be analyzed to determine enrichment without the need for calibration sources. As part of this effort, we performed a series of measurement campaigns in which we used an active well coincidence counter (AWCC) retrofitted with commercial D-D and D-T generators to evaluate the operational characteristics of this method in response to a set of uranium enrichment and mass standards, as well as representative diversion scenarios in which either “concealed” enriched uranium is shielded by depleted uranium or declared enriched uranium is “hollowed out” and replaced with a central region of depleted uranium. A standard operating procedure and best practices were compiled to facilitate the use of delayed neutron-based enrichment measurements for international safeguards inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The response of thermally and optically stimulated luminescence from Al2O3:C to high-energy heavy charged particles

The thermoluminescence (TL) and optically stimulated luminescence (OSL) response of Al2O3 dosimeters to high-energy heavy charged particles (HCP) has been studied using the heavy ion medical accelerator at Chiba, Japan. The samples were Al2O3 single-crystal chips, of the type usually known as TLD-500, and Luxel(TM) dosimeters (Al2O3:C powder in plastic) from Landauer Inc. The samples were exposed to 4He (150 MeV/u), 12C (400 MeV/u), 28Si (490 MeV/us) and 56Fe (500 MeV/u) ions, with linear energy transfer values covering the range from 2.26 to 189 keV/micrometers in water and doses from 1 to 100 mGy (to water). A 90Sr/90Y beta source, calibrated against a 60Co secondary standard, was used for calibration purposes. For OSL, we used both continuous-wave OSL measurements (CW-OSL, using green light stimulation at 525 nm) and pulsed OSL measurements (POSL, using 532 nm stimulation from a Nd:YAG Q-switched laser). The efficiencies (eta HCP, gamma) of the different HCPs at producing OSL or TL were observed to depend not only upon the linear energy transfer (LET) of the HCP, but also upon the sample type (single crystal chip or Luxel(TM)) and the luminescence method used to define the signal--i.e. TL, CW-OSL initial intensity, CW-OSL total area, or POSL. Observed changes in shape of the decay curve lead to potential methods for extracting LET information of unknown radiation fields. A discussion of the results is given, including the potential use of OSL from Al2O3 in the areas of space radiation dosimetry and radiation oncology. c2004 Elsevier Ltd. All rights reserved.

Heavy Ions↗

The Rapidly Fading Afterglow of GRB 980519

GRB 980519 had the most rapidly fading of the well-documented GRB afterglows, consistent with t(sup -2.05 +/- 0.04) in BVRI as well as in X-rays during the two days in which observations were made. We report VRI observations from the MDM 1.3m and WIYN 3.5m telescopes, and we synthesize an optical spectrum from all of the available photometry. The optical spectrum alone is well fitted by a power law of the form nu(sup - 1.20 +/- 0.25), with some of the uncertainty due to the significant Galactic reddening in this direction. The optical and X-ray spectra together are adequately fitted by a single power law nu(sup 1.05 +/- 0.10). This combination of steep temporal decay and flat broad-band spectrum places a severe strain on the simplest afterglow models involving spherical blast waves in a homogeneous medium. Instead, the rapid observed temporal decay is more consistent with 2 models of expansion into a medium of density n(r) proportional to r(sup -2), or with predictions of the evolution of a jet after it slows down and spreads laterally. The jet model would relax the energy requirements on some of the more extreme GRBs, of which GRB 980519 is likely to be an example because of its large gamma-ray fluence and faint host galaxy.

Halpern, Jules P.↗

GRB-081029: A Step Towards Understanding Multiple Afterglow Components

We present an analysis of the unusual optical light curve of the gamma-ray burst-081029 at a redshift of z = 3.8474. We combine X-ray and optical observations from (Swift) with optical and infrared data from REM to obtain a detailed data set extending from approx 10(exp 2)s to approx 10(exp 5)s after the BAT trigger, and from approx.10 keV to 16,000 AA. The X-ray afterglow showed a shallow initial decay followed by u rapid decay after about 18,000 s. The optical afterglow, however, shows an uncharecteristic rise at about 5000 s that has no corresponding feature in the X-ray light curve. The data are not consistent with a single-component jet. It is possible that there are multiple physical components contributing to the afterglow of GRB-081029.

Holland Stephen T.↗

Classification of Dissolution Events Using Fusion of Effluents Measurements and Classifiers

Classifiers for dissolution events at a radiochemical processing facility are studied using gamma spectra measurements of effluents collected by a high purity germanium detector located at its off-gas stack. Data sets collected at the Oak Ridge National Laboratory’s Radiochemical Engineering Development Center under a Pu dissolution campaign spanning a three months period are utilized. Features corresponding to the activity levels of 15 radionuclides, including isotopes of iodine, krypton, and xenon, that are indicated by the target decay chains, are computed from the spectra at 1 hour intervals. A conceptualization diagram is developed to reflect the steps from the source to measurement to feature computation that depend on fission products indicated by decay chains, chemical processing, and effluents transport to the off-gas stack. A diverse set of eight classifiers based on different design principles are trained using the ground truth data for this campaign, and the outputs of top three classifiers, namely, classification trees, Ensemble of Trees (EOT), and k-nearest neighbor, are combined using EOT classifier-fuser. Our results show that for 5-fold cross validation, features associated with isotopes of xenon provide the lowest classification error among the different elements across the classifiers; the classification error is furthered improved when all 15 isotope features are used by each classifier, and it is again improved by the fusion of three classifiers. Further reduction in classification error is achieved by using a measurement window of 1-2 days which is identified based on half-life time estimates of the isotopes; it is long enough for the stabilization of feature estimates while being short enough not to be affected by the follow on dissolution events. As a net result of feature and classifier fusion, combined with the incorporation of decay chain and isotope half-life information, this approach achieves 98% detection rate while maintaining a false alarm rate under 2% for this data set.

Rao, Nageswara↗

An optimized search for dark matter in the galactic halo with HAWC

The Galactic Halo is a key target for indirect dark matter detection. The High Altitude Water Cherenkov (HAWC) observatory is a high-energy (~300 GeV to >100 TeV) gamma-ray detector located in central Mexico. HAWC operates via the water Cherenkov technique and has both a wide field of view of ~ 2 sr and a >95% duty cycle, making it ideal for analyses of highly extended sources. We made use of these properties of HAWC and a new background-estimation technique optimized for extended sources to probe a large region of the Galactic Halo for dark matter signals. With this approach, we set improved constraints on dark matter annihilation and decay between masses of 10 and 100 TeV. Due to the large spatial extent of the HAWC field of view, these constraints are robust against uncertainties in the Galactic dark matter spatial profile.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of nuclear reactor radiation on the performance of AlN/sapphire surface acoustic wave devices

The performance of an AlN/sapphire surface acoustic wave (SAW) delay line device was characterized in real time under irradiation inside a nuclear reactor. Both its resonant frequency and transmission efficiency were observed to respond to a change in reactor power. The response follows an exponentially saturating behavior after a step power increase, followed by an exponentially decaying recovery after reactor shutdown. A sensitivity analysis based on the governing electro-mechanical equations shows that the frequency shift can be attributed to the softening of sapphire’s elastic constants under neutron radiation. Additionally, a kinetic rate equation is adopted to interpret device response and describe its microstructural evolution. These results suggest that the AlN/sapphire SAW device remains functional under irradiation, is sensitive to neutron and gamma ray fluxes, and offers an opportunity for remote sensing and in-situ measurement of material properties when exposed to nuclear reactor environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence for a Sudden Magnetic Field Reconfiguration in SGR 1900+14

We report on the detection of large flux changes in the persistent X-ray flux of SGR 1900+14 during its burst active episode in 1998. Most notably, we find a factor of approximately 700 increase in the non-burst X-ray flux following the August 27th flare that decayed in time as a power-law. Throughout the decay of this flux enhancement, our measurements indicate that the pulse fraction remains constant. This indicates a global flux enhancement as a consequence of the August 27th flare rather than localized heating. While the persistent flux has since recovered to the pre-outburst level, the pulse profile has not. The pulse shape changed to a near sinusoidal profile within the tail of the August 27th flare (in gamma-rays) and this effect has persisted for more than 1.5 years (in X-rays). The results presented here suggest the magnetic field of the neutron star in SGR 1900+14 was significantly altered (perhaps globally) during the giant flare of August 27.

Woods, Peter M.↗

Performance of High Stopping Power Bismuth-Loaded Plastic Scintillators for Radiation Portal Monitors

Plastic scintillators are widely used in radiation portal monitors because of their low cost and availability in large sizes. However, due to their low density and low effective atomic number (Z), they offer low intrinsic efficiency and little spectroscopic information. The addition of high-Z constituents to these plastics can greatly increase both their total stopping power and the amount of photoelectric absorption, leading to full-energy deposition and thus useful gamma spectra. Herein, we present the performance of the latest formulation of Bi-loaded plastic scintillators showing their useful spectroscopic information up to relatively high energy (~1 MeV) due to their high stopping power compared to the current commercially available plastics. These Bi-loaded plastics use 20 weight percent (wt%) Bi-pivalate (8 wt% elemental Bi) dissolved in polyvinyltoluene (PVT) matrix and conventional fast fluors (~10 ns decay time). These Bi-loaded plastics achieve up to approximately 6000 photons/MeV and have been produced in sizes up to 17 in 3 . The performance of these Bi-loaded plastics is also demonstrated in the existing portal monitor hardware (Rapiscan Model TSA Trainer 770) showing the possibility to provide improved sensitivity as a drop-in replacement with continued scale-up.

42 ENGINEERING↗

Molten Salt Reactor Experiment Simulation using Shift/Griffin

The Department of Energy (DOE)’s NEAMS focuses its efforts on the development of advanced modeling and simulation (M&S) tools for light-water reactors (LWRs) and non–LWRs (i.e., molten salt reactors, high-temperature gas reactors, microreactors, and fast reactors). In the previous fiscal year, the Multiphysics Applications Driver Technical Area funded molten salt reactor (MSR) M&S at Oak Ridge National Laboratory (ORNL) to generate multigroup macroscopic cross sections with Shift for a MSRE 2D lattice model in Griffin. In addition, Shift’s capability to calculate gamma dose rates from activated components in the primary exchangers in a molten salt breeder reactor was also demonstrated. In fiscal year 2023, ORNL generated multigroup macroscopic cross sections using Shift for a 3D MSRE core model. MSRE depletion calculations using Griffin were also demonstrated in this fiscal year. For the depletion calculation, one-group microscopic cross sections for the 3D MSRE core were generated using Shift, and the decay transmutation library from ORIGEN was converted to an ISOXML file, which is required as input in Griffin. Several Monte Carlo codes, such as OpenMC and Serpent, were also used to benchmark and supplement multigroup cross sections generated by Shift. Multigroup libraries were generated with 8 and 20 group structures, and the study found the 8-group structure to be more accurate when comparing Griffin results to continuous energy (CE) Monte Carlo results. The average flux from CE Shift calculations is up to ~6% higher than the CE Serpent calculations because of different values applied for the energy released per fission (κ values). The average flux in the fuel salt calculated by Griffin using cross sections generated with Shift agrees well with the reference CE Shift solution; the same is valid for the corresponding Serpent results. The maximum relative error is ~6% and ~2% compared to the CE Shift and Serpent reference solutions, respectively. Meanwhile, the average flux calculated by Griffin in the graphite moderator shows a higher difference in the thermal range when compared to both reference Monte Carlo solutions; this result suggests a need for improvement in cross section generation for the graphite moderator in the thermal range in both Monte Carlo codes. Griffin depletion calculations using cross sections from Shift and Serpent were performed and compared against ORIGEN calculations, and the nuclide densities calculated by Griffin were found to be generally in agreement with those of ORIGEN. Because a different approach was taken to calculate the energy released per fission ( κ values) in Shift and Serpent, a difference in nuclide densities from differences in the average flux was observed between Griffin using Serpent and Shift cross sections. Griffin calculations with Shift cross sections produced higher average flux in the salt than with Serpent cross sections, leading to higher consumption of 235 U and higher production of 135 Xe. For time-dependent depletion calculations, cross sections were generated with Serpent, and Griffin’s results using these cross sections were compared to CE Serpent depletion results, demonstrating good agreement. The average difference in keff between Serpent and Griffin as a function of burnup is about 155 pcm. Similarly, good agreement with small differences up to ~0.5% was also noticed in the nuclide density of 235 U and 135 Xe. More details regarding the methodologies invoked to generate the cross section to make code-to-code comparisons are discussed further in this report. User feedback on Griffin and Shift capabilities that will enhance these calculations is provided in this report for future consideration. The work performed this fiscal year can be extended further for multiphysics coupling of Griffin-Pronghorn/SAM with Mole to study precursor flow and salt chemistry.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The gamma-ray spectrum of the Galactic-center region

The HEAO-3 High Resolution Gamma-Ray Spectrometer observed the Galactic center region in fall 1979 and in the spring of 1980. Variation of the positron annihilation line at 511 keV has been reported previously. The fall 1979 observations show a significant high-energy continuum at energies above 511 keV. The intensity of a possible positronium triplet-state continuum is found to be less than that expected for direct positron annihilation and positronium decay in an ionized, warm (T approximately equal to or less than 10 to the 5th K) plasma. Depending on assumption for the shape of the high-energy continuum spectrum, positronium fractions between 0.0 and 0.75 (at 90 percent statistical confidence level) are consistent with the observations.

Riegler, G. R.↗

GRIS background reduction results using isotopically enriched Ge

The Gamma Ray Imaging Spectrometer (GRIS) was flown twice from Alice Springs, Australia, in the spring of 1992 for a total of 32 hr at float altitude. One of the seven Ge detectors was isotopically enriched (greater than 97% Ge-70). This was the first time an enriched-Ge detector was used for astrophysical observations. Because of its thick anticoincidence shield, the GRIS instrument background is dominated by internal beta-decay in the energy range of 200-1000 keV. Half of the contribution in this beta-decay 'hump' is due to neutron-activated Ge-74. In this energy range, GRIS observed a factor of 2 reduction in the background in the enriched detector, as predicted. In future instruments (e.g., INTEGRAL), with thicker anticoincidence shields and smaller apertures, the background reduction will be even larger. Three strong instrumental background lines (54, 67, and 139 keV) are also eliminated. The elimination of the first two is particularly important for cylotron line observations.

Barthelmy, S. D.↗