Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fuel cladding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Impact of LWR assembly structural features on cladding burst behavior under LOCA conditions

This provides an initial scoping study on clad balloon and burst behavior for burnup extension of reactor fuel. The associated issues with burnup extension are fuel fragmentation, relocation, and dispersal in the event of cladding failure. The general finding of this work is that the structural features, spacer grids and mixing vanes, locally suppress cladding deformation but have little impact on the overall clad performance during loss-of-coolant accidents. The work detailed in a previous report by Capps et al. focused on core optimization via neutronics, thermal hydraulics and thermomechanical analysis for burnups beyond 62 GWD/tU and enrichments above 5%. Uncertainty of fuel fragmentation relocation and dispersal in high-burnup rods during accident conditions was also investigated. The dispersal aspect of fuel fragmentation depends on cladding rupture. Thus, assessing uncertainties in the rupture behavior is helpful in estimating the dispersal of high-burnup fuel. This study builds on the previous work by assessing the impact of assembly structural features on cladding balloon and burst behavior in a full-length fuel rod. In this work, the BISON fuel performance code was used to generate 2D radial and height meshes containing structural features commonly used in nuclear fuel assemblies. First, meshes were generated with spacer grids. Results were then compared to the cladding burst temperature and balloon strain results from the previous work. A mesh sensitivity study was performed to ensure that mixing vanes and spacer grid effects were appropriately considered, resulting in a more refined mesh than the previous study. The balloon deformation and burst times of the cladding were compared to the original case. Consideration was also given to the effect of rod initial pressure. In conclusion, 3D quarter rod simulations were also performed and found good agreement with the 2D simulations in clad deformation and reasonable agreement in burst times.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Multiphysics Code Coupling for Cladding Surface Thermocouples During Two-Phase Heat Transfer from Nuclear Fuel

Transient testing of nuclear fuel involves the evaluation of fuel performance under off-normal and accident conditions and is essential for proving design performance. Instrumentation included in such experiments commonly includes thermocouples attached to the outer surface of the cladding to provide temperature measurements throughout the transient. However, the presence of thermocouples on the cladding surface can alter the local heat transfer characteristics with the surrounding coolant. These localized effects can influence the temperature of the nearby cladding surface and introduce uncertainties in interpreting the thermocouple data. Understanding the impact of thermocouples attached to the outer surface of the cladding is crucial for accurate data interpretation as well as its effect on the thermomechanical behavior of the cladding. This paper presents a novel methodology for simulating the impact of outer cladding thermocouples during transient testing of nuclear fuels. The simulation framework leverages the thermal-hydraulic capabilities of RELAP5-3D coupled to the BISON fuel performance code through the RELAPCouplingApp interface. The methodology is compared against Accident Tolerant Fuel Reactivity Initiated Accident-1-E experiment performed at Idaho National Laboratory. The results reveal approximately 100°C difference between thermocouple-altered temperature and virgin cladding surface. The model overpredicts surface rewet time due to conservative correlations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Burnup LOCA Burst Susceptibility BISON Analysis in PWRs and BWRs

Accurately assessing high-burnup fuel behavior during loss-of-coolant accidents (LOCAs) is essential for understanding fuel fragmentation, relocation, and dispersal (FFRD) risks across the US light-water reactor fleet. This work updates previous Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program multiphysics LOCA analyses for a pressurized water reactor (PWR) and a boiling water reactor (BWR) by incorporating recent model and material property advancements in the BISON fuel performance code, including a high-burnup structure (HBS) model, revised cladding burst criteria, and updated thermal–mechanical correlations. This update was needed to support ongoing industry initiatives and upcoming regulatory changes. Full-core, rod-resolved operating histories generated using Virtual Environment for Reactor Analysis (VERA) and system-level LOCA conditions obtained from TRACE were applied to statistically representative rod samples in BISON to evaluate burst behavior and FFRD susceptibility. These calculations used two cladding burst correlations and three fuel pulverization models so that the predictions of these models could be compared. The updated PWR simulations show markedly improved numerical stability as the number of crashed simulations decreased by 95% compared to the previous study, and hence higher confidence in results. The updated PWR simulations predicted cladding bursts exclusively among once-burned, high-power rods, with two different cladding burst models identifying the same burst-susceptible population. Resulting FFRD susceptibility estimates are significantly reduced compared with earlier studies, driven by cooler predicted fuel and plenum temperatures, lower hoop strains, and reduced fission gas release in the updated models. In contrast, none of the BWR rods were predicted to burst under either burst criterion, reaffirming minimal BWR FFRD susceptibility even with updated HBS and material models. Comparisons between the PWR and BWR end-of-cycle predictions are made. Comparison with prior work highlights significant shifts in PWR fuel performance metrics and confirmation of earlier BWR conclusions. Overall, the updated results underscore the importance of having high-resolution detailed modeling capability and continuously integrating evolving material models and physics into high-resolution multiphysics simulations. The unified assessment presented here strengthens confidence in predicting high-burnup LOCA behavior by improving agreement between different cladding burst correlations. These results also provide an improved foundation for future BISON model development, FFRD susceptibility calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding Fission Gas Bubble Distribution and Zirconium Redistribution in Neutron-irradiated U-Zr Metallic Fuel Using Machine Learning

U-10wt.% Zr (U-10Zr) based metallic fuel is the leading candidate for next-generation sodium cooled fast reactor in United States. Currently, Idaho National Laboratory (INL) has been the leading national laboratory for research, development, and demonstration (RD&D) on metallic fuel. Advanced post-irradiation characterization will help to understand fuel microstructure and property change during irradiation, benefiting fuel qualification for commercial application. Characterization capabilities ranging from sub-nanometer to micrometer, such as scanning electron microscopy (SEM), focused ion beam (FIB) sampling, transmission electron microscopy (TEM) characterization, and local thermal conductivity microscopy (TCM), have been utilized recently on irradiated U-10Zr fuel samples to gain a better understanding of nuclear fuel microstructure and property evolution inside a reactor. The FIB/SEM coupled with energy dispersive X-ray spectroscopy (EDS) can capture the essential information to achieve better understanding of fuel behaviors. Inside a nuclear reactor, the phase and microstructure of U-10Zr is constantly changing under neutron bombardment. For example, the gaseous fission product atoms have a limited solubility inside fuel matrix and tend to precipitate out in bubble form, which not only contribute to fuel thermal conductivity degradation but also provide a shortcut for movement of fission products, i.e. lanthanides. The resultant deposition of lanthanides at the cladding inner surface will potentially trigger a chemical reaction/interaction between nuclear fuel and cladding at reactor operational conditions, threatening fuel integrity and safety. FIB/SEM coupled with EDS can provide the fission bubble information as well as probe into phase separation or Zr redistribution, which is fundamental to predict the fuel performance. With high velocity image data generating method, such as FIB/SEM, an automatic way to extract the microstructural information quantitively can better serve the needs from post irradiation characterization. A trained machine learning model, named Decision Tree, is employed to generate a bubble classifier and to categorize bubbles into three categories: isolated bubble, connected without lanthanides, and connected with lanthanides bubbles[3]. This work presents a showcase of this approach on six regions of a fuel cross-section along the radial temperature gradient. We obtained distributions of bubble categories and porosity rates along the six regions. Moreover, a secondary phase U-Zr2 was determined and found on regions 5 and 6. The secondary phase fraction was increasing from 15.61% in region 5 to 34.79% in region 6 based on this approach . This quantitative data offers insights into the lanthanide migration and potentially thermal conductivity degradation. This information from machine learning will be fed into fuel design code for better prediction of fuel performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chromium-coated cladding analysis under simulated LOCA burst conditions

Of the near-term accident-tolerant fuel concepts identified, chromium coatings have been shown to slow cladding oxidation without altering fuel system geometry or greatly affecting neutronic performance. To identify how coated cladding tubes perform under high-temperature accident conditions, pressurized-tube burst tests were conducted in the Severe Accident Test Station at Oak Ridge National Laboratory. To analyze how the coating affects cladding behavior, coated and uncoated cladding burst tests were simulated by using the BISON fuel performance code. Thermocouple data from these tests were fit into axial and azimuthal profiles and combined to generate 3D cladding surface temperatures, and pressure transducer data were compared until cladding failure. Additionally, the cladding temperatures at failure and the internal gas pressure evolution show relatively good agreement between the simulation and experiment results. Simulations were then extrapolated to demonstrate the coatings effectiveness to increasing the cladding burst temperature by using a parametric evaluation of the initial tube gas pressure. This work demonstrates the possibility of an increased cladding failure margin under transient conditions due to the addition of chromium coating, and more pertinently, an increased cladding failure margin from more accurate experimental characterization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results of Uranium Dioxide-Tungsten Irradiation Test and Post-Test Examination

A uranium dioxide (UO2) fueled capsule was fabricated and irradiated in the NASA Plum Brook Reactor Facility. The capsule consisted of two bulk UO2 specimens clad with chemically vapor deposited tungsten (CVD W) 0.762 and 0.1016 cm (0.030-and 0.040-in.) thick, respectively. The second specimen with 0.1016-cm (0.040-in.) thick cladding was irradiated at temperature for 2607 hours, corresponding to an average burnup of 1.516 x 10 to the 20th power fissions/cu cm. Postirradiation examination showed distortion in the bottom end cap, failure of the weld joint, and fracture of the central vent tube. Diametral growth was 1.3 percent. No evidence of gross interaction between CVD tungsten or arc-cast tungsten cladding and the UO2 fuel was observed. Some of the fission gases passed from the fuel cavity to the gas surrounding the fuel specimen via the vent tube and possibly the end-cap weld failure. Whether the UO2 loss rates through the vent tube were within acceptable limits could not be determined in view of the end-cap weld failure.

Collins, J. F.↗

Experimental evaluation of direct current magnetron sputtered and high-power impulse magnetron sputtered Cr coatings on SiC for light water reactor applications

Two types of physical vapor deposition Cr coatings were deposited on chemical vapor deposited SiC coupons using conventional direct current magnetron sputtering (DCMS) and high-power impulse magnetron sputtering (HiPIMS) to mitigate the corrosion of SiC, an advanced fuel and structural material in light water nuclear reactor cores. Coating microstructure was characterized using scanning electron microscopy and scanning transmission election microscopy. X-ray diffraction analysis was conducted for phase identification and qualitative analysis of residual stresses. The mechanical integrity of the coatings was evaluated using scratch testing, micro-indentation, and nano-indentation tests. Additionally, the microstructure of the DCMS coating consisted of fine columnar grains with nanoscale intercolumnar channels, while the HiPIMS microstructure was denser and free of any columnar defects. The DCMS coating showed a small tensile residual stress, while the HiPIMS coating was under compressive stress. Both types of coatings showed good mechanical integrity in terms of ductility and adhesion to the substrate. Corrosion performance of the coatings was assessed with a 30-day high temperature water autoclave test. Both types of coatings formed a protective Cr 2 O 3 surface layer 20-30 nm thick during the autoclave test. In the DCMS coating, the columnar defects provided permeation pathways for water penetration resulting in oxide formation in the intercolumnar regions in the interior of the coating. Overall, both types of Cr coatings offer promise for the mitigation of hydrothermal corrosion of SiC in light water reactor operating environments.

36 MATERIALS SCIENCE↗

Augmented Monitoring and Condition Assessment Program (AMCAP) Material Test Reactor (MTR) (Fuel Inspection Program Report)

The AMCAP MTR Fuel Inspection Program, a special inspection program comprised of four inspection campaigns, examined a total of ten (10) pre-selected aluminum-clad, aluminum-based fuel core spent nuclear fuel assemblies (ASNF) stored in the L Area Disassembly Basin (L Basin) at the Savannah River Site. A full description of the inspections and the results are reported. The fuel had been stored in bundled-tube storage (Vertical Tube Storage) for periods of 18 to 21 years. The prior service experience of the individual 10 assemblies varies, but all included irradiation followed by wet storage at international research reactor sites prior to shipment to the US and storage in L Basin. The 10 assemblies were expected to be among the “worst"’ in terms of prior corrosion damage of the entire inventory of the direct-bundle-stored ASNF in L Basin. The inventory of MTR ASNF in L Basin will continue to be stored in the bundled-tube configuration or in slug-storage buckets with inserts pending retrieval for ultimate disposition. The MTR fuel inspections focused on collecting information for characterization of the material condition of the ASNF considering various types of aluminum fuel corrosion degradation of its assembled materials in water storage. A custom-designed Fuel Inspection Table was used to stage the fuel for remote, enhanced visual examination (close-up video imaging & recording) with controlled lighting and positioning that enables reproducibility of imaging conditions. The inspections were conducted by fuel subject matter expert staff from Spent Fuel Project Engineering (SFPE) and the Savannah River National Laboratory (SRNL). Stills captured from the video records were used to compare the corrosion evolution from previous records, as available. This evaluation of the inspection results including the comparison to the previous inspection results demonstrate that the water quality and the storage configuration of ASNF in L Basin do not cause aggressive corrosion degradation of the fuel; mitigation of the prior corrosion degradation of the fuel also appears to have been achieved with the good water quality conditions of L Basin. Recommendations are made for future inspection of the fuel to trend corrosion degradation and demonstrate continued safe wet storage of the ASNF in L Basin. The next fuel examination is recommended to be performed in 5 years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Critical Review of High Burnup Fuel Fragmentation, Relocation, and Dispersal under Loss-Of-Coolant Accident Conditions

High burnup fuel in excess of ~6268 GWd/MTU has been observed to severely fragment when subjected to temperature transient conditions as in a loss-of-coolant accident. In the event of cladding failure, the severely fragmented fuel can relocate into the balloon region and potentially disperse through the burst opening into the reactor’s primary system. This observation has led to implementation of several independent test programs designed to focus on various aspects of fuel fragmentation, relocation, and dispersal. The purpose of this review is to perform a critical, holistic assessment of fuel fragmentation, relocation, and dispersal under loss-of-coolant conditions to identify data gaps in the experimental data base. Phenomena have been identified and well defined through the various testing programs, and general agreement regarding the governing parameters (temperature, burnup, heating rate, cladding deformation, etc.) has been established. However, there is a significant data gap connecting research to commercial application. Furthermore, previous research attempted to evaluate the problem holistically, but has yet to provide a comprehensive understanding of the problem. Major identified data gaps consist of (1) a comprehensive understanding of pretransient fuel rod conditions (fuel temperature, fuel stress, rod internal pressures, microstructure, etc.), (2) definition of prototypic loss-of-coolant accident conditions (heating rate, fuel temperatures, fuel stress), (3) identification of the differences between nuclear and electrical integral loss-of-coolant accident tests, and connection of fuel rod performance (cladding ballooning, burst opening, potential relocation, fragmentation susceptibility, etc.) to fuel fragmentation, relocation, and dispersal severity. Finally, the content of this manuscript provides a clear path for connecting testing and data acquisition to commercial application by providing concrete means for filling data gaps and prioritized testing regimes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Demonstration of new fracture criteria based on micro-structure and compare to empirical model and measurements

The US nuclear industry is currently exploring extending the peak rod average burnup limits above the current regulatory limit of 62 GWd/tU. A potential concern for fuel exceeding the burnup limit is the fragmentation during a temperature transient such as a loss-of-coolant accident (LOCA). In the event of cladding failure, the fragmented fuel could relocate and disperse within the reactor. The potential impact of fuel fragmentation, relocation and dispersal (FFRD) on licensing assumptions for burnup extension has focused a great amount of efforts and research on this topic.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamical System Scaling Application to Zircaloy Cladding Thermal Response During Reactivity-Initiated Accident Experiment

New fuel design and development currently requires 20 to 25 years to be qualified for use by the nuclear power industry. The thermal-hydraulics community has taken advantage of scaling theory to design reduced scale experiments that correctly preserve dominant key phenomena while quantifying distorted phenomena. These techniques can be leveraged in the design and analysis of fuel performance experiments to help reduce the timeline associated with fuel design and development. This study uses the Dynamical System Scaling (DSS) method to analyze cladding temperature data from the recent SETH-C experiment in the TREAT facility and accompanying BISON simulations to assess dynamic distortions occurring throughout the fast power excursion transient. The DSS analysis revealed that on the cool down from peak cladding temperature that the fuel radial power profile is the most sensitive modeling parameter with a heterogenous radial peaking factor corresponding to the lowest distortion compared to a uniform energy deposition. For the heat up to peak cladding temperature the heterogeneous radial power profile corresponded to the shortest process action. Finally, for the heat up to peak cladding temperature, the gap conductance model sensitivity was quantified using process action and shows that the default Light Water Reactor gap conductance model corresponded to the longest process action.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational Investigation of Fuel Dispersal Phenomena during Large-Break Loss of Coolant Accident in Light-Water Reactors

In the event of cladding rupture, which could occur in light water reactor fuel assemblies during a loss-of-coolant accident (LOCA), fuel particles, along with fission gases, can be expelled into the reactor core from the fractured fuel rod. This expulsion of fragmented fuel particles, referred as fuel dispersal, is the subject of investigation to evaluate the safety implications of increasing fuel burnup in light water reactors, with a specific focus on fuel fragmentation, relocation, and dispersal. Particle trajectories and the resulting mass distribution of the settled particles within the reactor pressure vessel can pose a long-term cooling challenge for the reactor core. The fuel dispersal phenomenon is significantly influenced by the ejection characteristics of the fuel fragments, as well as the size and shape of the cladding rupture and fuel rod depressurization history during LOCA transients. In this study, the transport of fuel particles within a scaled 5 × 5 lattice of a pressurized water reactor rod bundle geometry is modeled through a two-fluid Eulerian framework that treats the gas and solid phases as interpenetrating continua. The required boundary conditions are evaluated from the fuel performance code BISON in a postulated large-break LOCA scenario. The modeling framework considers solid fuel particles as granular matter, interacting with the gaseous dry steam phase and fission gases through the governing interfacial momentum and energy exchange between the gas and solid phases. The simulation results provide the volume fraction of the solids settled on the bottom surface of the fuel bundle, quantifying the deposition within the bundle geometry.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wrought FeCrAl alloy (C26M) cladding behavior and burst under simulated loss-of-coolant accident conditions

Cladding burst experiments for FeCrAl cladding were performed in the Severe Accident Test Station facility at Oak Ridge National Laboratory. These experiments were simulated using the BISON fuel performance code to better understand the cladding plastic behavior and failure under simulated loss-of-coolant accident conditions. 3D cladding surface boundary conditions were generated using composite axial and azimuthal profiles from experiment thermocouple data. To improve the simulation analysis capabilities in BISON for cladding burst behavior, new thermal creep, plasticity, and failure stress models specific to C26M, a wrought FeCrAl alloy, were developed and implemented. Initial cladding burst results indicated a general underprediction in the failure temperature of the six cladding burst simulations versus the observed failure temperatures. Close investigation of the experiment timing versus the underlying tensile test data revealed that, compared with the tensile specimens, the cladding tubes did not experience the same long holding time at high temperatures. New tensile tests were performed at high temperatures using a temperature ramp similar to the simulated loss-of-coolant accident experiments. These new tensile curves showed an approximately 80% increase in the ultimate tensile strength of the C26M alloy, indicating that a holding time of 10 min at 700 °C and 800 °C allows annealing to change the material microstructure. Using the updated tensile properties, the burst temperatures and stresses from the simulations showed remarkable agreement with the experimental results. This study was then extended by varying the initial pressure to highlight the burst temperature difference between standard Zircaloy-4 and C26M cladding under equivalent conditions. The results show that C26M has a burst temperature that is approximately 70–130 K greater than that of Zircaloy-4. In conclusion, these modeling predictions can be further improved by collecting high-temperature tensile data for C26M beyond the temperature ranges used in this work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sister Rod Destructive Examinations (FY23) Appendix F3: Uncertainty and Conservative Bias in the Cyclic Integrated Reversible-Bending Fatigue Test

The development and application of the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) has been documented over the past 10 years. The CIRFT system was developed in collaboration with the U.S. Nuclear Regulatory Commission (NRC) to address the concern that high-burnup fuel rod fatigue performance was degraded compared to cladding-only behavior. Fatigue data measured by CIRFT on high-burnup fuel rods were then used by the NRC to develop a fatigue response curve for pressurized water reactor fuel rods with Zircaloy-4 cladding in NUREG-2224. Subsequently, CIRFT has been used in the sister rod project to test whether reoriented hydrides associated with vacuum drying influenced the fatigue lifetime, to extend the fatigue testing database to include fuel rods with ZIRLO cladding, and to add to the experience on both Zircaloy-4 and M5 cladding. These data will be used as a reference for subsequent characterization of fuel rods removed from the high-burnup demonstration cask to better understand the effects of long-term dry storage, which can be thought of as a multiyear elevated temperature anneal. The objective of fatigue testing is to provide data that can be used to develop a best-estimate fatigue curve and a conservative fatigue design curve that accounts for uncertainty and can be compared with actual transportation conditions. The process for defining a design fatigue curve for commercial used fuel rods was developed by Oak Ridge National Laboratory (ORNL) in FY22. One issue noted in the fatigue evaluation was that the calculated combined uncertainty in the strain amplitude values determined from the measured data was large. It was proposed then to directly measure the uncertainty in the strain amplitude to either validate the calculated combined uncertainty or update the uncertainty based on the measurement data. Thus, the purpose of this appendix is to document the measured uncertainty in the strain amplitude data. In the process, it was determined that there has been a conservative bias in the calculated strain amplitude that is small enough to be within the measurement uncertainty. This observation is discussed herein, and a case is made to continue to include the conservative bias in the data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conjugate Heat Transfer Modeling of Salt-Filled Fuel Pins for Stable Salt Reactor Safety Analysis

The Stable Salt Reactor (SSR) combines the proven structural design of light water reactor fuel assemblies with the inherent safety and fuel-cycle advantages of molten salt technology. In its fast reactor configuration, the SSR utilizes recycled nuclear waste as fuel, sealed within narrow salt-filled fuel pins and cooled by a surrounding liquid salt coolant. Reliable transfer of heat from the molten fuel salt through the cladding to the external coolant is essential for both reactor safety and performance. This work investigates conjugate heat transfer (CHT) in the SSR’s salt-filled fuel pins using NekRS, a high-fidelity spectral element computational fluid dynamics (CFD) solver. The analyses capture internal natural convection within the molten fuel salt and external forced convection in the coolant, under steady-state and transient operating conditions. Parametric studies evaluate how variations in reactor power and coolant flow rate influence heat transfer distributions and system response. The high-fidelity CFD results are time-averaged and post-processed for direct comparison with moderate-fidelity Reynolds-averaged Navier–Stokes (RANS) models, and for the development of reduced-order models within the SAM system code. These validated models support fast-running safety analyses of normal and off-normal transients, improving predictive capability for key safety margins. By integrating advanced CFD with system-level safety tools, this study strengthens the modeling framework for SSR design, reduces uncertainty in molten salt CHT simulations, and accelerates the engineering and licensing of next-generation nuclear reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cold spray chromium coating for nuclear fuel rods

A zirconium alloy cladding tube for use in a water cooled nuclear reactor under normal operating conditions and under high temperature oxidation conditions is described. The cladding tube has a coating uniformly deposited thereon. The coating, which may be up to 300 microns thick, is selected from the group consisting of chromium, a chromium-based alloy, and combinations thereof.

36 MATERIALS SCIENCE↗

Amphiphilic Block Copolymers for Flocculation and Hydrophobization of Legacy Waste Suspensions in Flotation Driven Dewatering Operations

There exists a degrading legacy fuel pond at the Sellafield site (UK), known as the First-Generation Magnox Storage Pond (FGMSP). After being placed into a passive care and maintenance regime resulting in a long storage period, the fuel rods, primarily their cladding, corroded in the pond forming magnesium hydroxide based sludges and suspended material. These ponds are a grave concern to the British government in terms of hazard and risk reduction. Therefore, decommissioning of these ponds is a top priority beginning with the contaminant retrievals process [1]. The pond has accumulated significant quantities of waste materials amongst the skips of fuel, including but not limited to: large inventories of corroded Magnox sludge, fuel rod fragments, metal fragments (from fuel skips), concrete degradation products (from the pond infrastructure), wind-blown sand, and other materials such as bird guano and animal remains. This challenge requires a chemically robust technology to complete sludge retrievals [2]. As nuclear is different, a more stringent process operation criteria is required. From the criteria, flotation was selected as a viable technology. Flotation involves the application of collector molecules which modify the hydrophobicity of suspended particles allowing them to adsorb to rising bubbles. As some particles lack inertia for flotation due to their size, dual flocculant/collector agents can be deployed for greater particle recovery, in this case, amphiphilic diblock copolymers. Two copolymers of Poly(acrylic acid)-b-poly(n-butyl acrylate) (or PAA-b-PnBA), of different hydrophobic chain lengths (PBA) were synthesized for flotation campaigns. Flotation has shown promise to be a valuable rapid dewatering strategy for decommissioning of legacy waste ponds whilst upholding the required operational criteria. This research has shown: PAA-b-PnBA copolymers promote flocculation of Mg(OH){sub 2} particulates. Diblock copolymers retain more fluid than traditional surfactant based collectors wrt. relative particulate recovery performance- where longer PnBA chain length polymers performed best. Performance appears to be hydrodynamically limited due to over-flocculation of Mg(OH){sub 2}. Potential to combine with sedimentation for high particle recovery with low fluid carryover.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of ceria as a surrogate material for UO 2 in experiments on fuel cracking driven by resistive heating

A variety of normal operation and accident scenarios can generate thermal stresses large enough to cause cracking in light-water reactor (LWR) fuel pellets. Cracking of fuel pellets can lead to reduced heat removal, larger centerline temperatures, and localized stress in cladding all of which impact fuel performance. Furthermore, pellet cracking also contributes to a temperature reduction in the pellet since the pellet fragments tend to move towards the heat sink (cladding), and the heat flow remains predominantly radial despite the presence of cracks. It is important to understand the temperature profile on the pellet before and after cracking to improve cracking models in fuel performance codes However, in-reactor observation and measurement of cracking is very challenging owing to the harsh environment and design of fuel rods. Recently, an experimental pellet cracking test stand was developed for separate effects testing of normal operations and accident temperature conditions, using thermal imaging to capture the pellet surface temperature for evaluation of thermal stresses and optical imaging to capture the evolution of cracking in real time. Cracking experiments were initially performed using ceria (CeO 2 ) as a surrogate fuel material, which is useful for developing and demonstrating the experimental approaches but is also valuable in its own right for cracking model development and validation. A combination of induction and resistance heating was used for volumetric heat generation in the pellet creating a thermal gradient. The material properties of CeO 2 and UO 2 are reviewed and compared for use in model development. Simulations of the experiment were performed to evaluate the behavior of the surrogate (CeO 2 ) fuel in BISON. The measured temperature profiles from BISON models match reasonably well with the observed experiments for the ceria pellets before cracking. The findings from this work will help improve confidence in fracture models used for fuel pellets under similar in-reactor conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗